975 resultados para Perforated plate
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Tese de Doutoramento em Engenharia Civil
Resumo:
Tese de Doutoramento em Engenharia Civil.
Resumo:
Stents are rigid and perforated tubular structures, which are inserted into blood vessels in order to prevent or inhibit the constriction of blood flow, restoring the normal blood flow, when blood vessels are clogged, being used in 70% of angioplasties. These medical devices assume great importance in the treatment of cardiovascular diseases (CVD) which are the leading cause of death worldwide. In the European Union CVD account for 40% of deaths and assume an estimated annual cost of 196 billion euros[1]. Stents must possess certain requirements, in order to, adequately, perform its function, such as biocompatibility (so that its use does not c ause damage on the health of its user), mechanical strength, radiopacity (so that it is easy to view), longitudinal flexibility, ease of handling, corrosion resistance and having high strength and high radial expansion ability to recover. Stents can be made of different materials, but metals, particularly stainless steel, are the most common. However, metallic stents present several dRawbacks such as corrosion and restenosis, leading to health complications for the patient, or even death. In order to minimize these disadvantages, new materials, like fibrous materials, have been used [2]. Monofilaments present high potential for stents development because, in addition to its biocompatibility, these materials allow the application of various surface treatments, such as antibacterial coatings. Furthermore, monofilament exhibit excellent mechanical properties, like greater stiffness and good results when subjected to compression, tensile and bending forces, since these forces will be directly supported by the monofilament [3]. To minimize the reaction of the human body and Limit the adhesion of microorganisms to the stent surface, some coatings have been developed, including the use of novel metals with antimicrobial properties, like silver. The main objective of this study was the development of fibrous stents, incorporation of silver oxide nanocoating. For the development of the stent, polyester monofilaments with 0.27mm of diameter were used in braiding technology, with a mandrel diameter of 6mm and a braiding angle of 35⁰. The mechanical behaviour of the stent were evaluated by mechanical testing under longitudinal and radial compression, bending. The results of compressive strength tests are according with value from literature: 1.13 to 2.9 N for radial compression and 0. 16-5.28N to longitudinal compression. From literature is also possible to verify that stents must present 75% of unchanged diameter during the bending test and must possess a porosity between 70% and 80% [4]. The produced polyester stent presents values of 1.29N for radial compression, 0.23N for longitudinal compression, 80% of porosity and 85.5% of unchanged diameter, during bending tests. For the antibacterial functionalization, silver oxide nanocoatings were prepared, through reactive magnetron g, with an Ag target in an Ar +O2 atmosphere. In order to evaluate the nanostructure and morphology of the coatings, d ifferent technique s like X-ray diffraction (XRD), scanning electron microscopy (SEM) and and X- ray photoelectron spectroscopy (XPS were used. From the analyses of XRD it is possible to verify that the peaks corresponds to planes of Ag2 O and MATERIAIS 2015 Porto, 21-23 June, 2015 characterize a cubic phase. The presence of Ag2 O is corroborated by XPS spectrum, where it is possible to observe silver, not only, in oxide state, but a lso in mettalic state, and it is possible to verify the presence of silver clusters, confirmed by SEM analysis. Films’ roughness and topography, parameters influencing the wettability of the surface and microorganism adhesion, were measured by Atomic Force Microscopy (AFM), and it was observed that the roughness is very low (under 10 nm). Coatings’ hydrophobicity and surface tension parameters were determined by contact angle measurement, and it was verified the hydrophobic behavior of the coatings. For antibacterial tests were used Staphylococcus epidermidis strain (IE186) and Staphylococcus aureus(ATCC 6538), and halo inhibition zone tests were realized. Ag+release rates were studied by means of inductively coupled plasma mass spectrometry (ICP -MS). The obtained results suggest that silver oxide coatings do not modify significantly surface properties of the substrate, like hydrophobicity and roughness, and present antimicrobial properties for both bacteria used.
Resumo:
Dissertação de mestrado em Engenharia e Gestão da Qualidade
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica
Resumo:
Brucellosis and leptospirosis are widely spread bacterial infections and dogs are the most important source of infection and reservoir for diseases. Dogs can disseminate the agents in the environment and transmit them to humans and/or other animals. The objective of this study was assess the occurrence of reactive to antibodies anti-Leptospira spp., Brucella canis and B. abortus in Belém and Castanhal, State of Pará, Amazon, Brazil. A total of 156 samples were randomly collected in the city of Belém and 158 samples in Castanhal. The anti-B. canis antibodies research was performed by Agar Gel Immunodiffusion (AGID) with and without 2-mercaptoethanol serum treatment (AGID-2ME). To assess the anti-B. abortus antibodies, the technique of Fast Seroagglutination with buffered acidified plate antigen (BAPAT) was used. For anti-Leptospira spp. antibodies research, the Microscopic Agglutination Technique (MAT) was used. No animal reacted to Brucella abortus and one animal was reactive to B. canis at the AGID, but it was negative to the AGID-2ME test. Seventeen percent of dogs (47/274) presented anti-Leptospira spp. antibodies, with prevalence of serovar Canicola. The dogs from Belém and Castanhal are not source of infection for B. abortus and B. canis, however, they are reservoirs for different serovars of Leptospira spp.
Resumo:
Tese de Doutoramento em Biologia de Plantas
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
A galactose-specific lectin from Bauhinia monandra leaves (BmoLL) have been purified through ammonium sulphate fractionation followed by guar gel affinity chromatography column. This study aimed to evaluate the potential anti-inflammatory and antinociceptive activity of pure BmoLL in mice. Anti-inflammatory activity was evaluated by 1% carrageenan-induced inflammation in mice treated with BmoLL. Acetic acid-induced abdominal writhing and hot plate methods evaluated antinociceptive activity. BmoLL significantly inhibited the carrageenan-induced paw edema by 47% (30 mg/kg) and 60.5% (60 mg/kg); acetylsalicylic acid (ASA, 100 mg/kg) showed inhibition of 70.5%, in comparison to controls. Leukocyte migration, an immune response to the inflammation process, was significantly reduced in presence of BmoLL; in mice treated with \ASA\ the decrease in leukocyte migration was similar to 15 mg/kg of the lectin. BmoLL at doses of 15, 30 and 60 mg/kg significantly reduced the number of animal contortions by 43.1, 50.1 and 71.3%, respectively.BmoLL leukocyte migration was significantly reduced; in mice treated with \ASA\ the decrease in leukocyte migration was similar to 15 mg/kg of the lectin. BmoLL at doses of 15, 30 and 60 mg/kg significantly reduced the number of animal contortions by 43.1, 50.1 and 71.3%, respectively. The lectin (30 and 60 mg/kg) showed a significant effect in the hot plate assay. BmoLL anti-inflammatory and antinociceptive effects were dose-dependent. The search for new and natural compounds, with minimal side effects, to control pain and inflammation, is constantly increasing. BmoLL has great potential as a natural anti-inflamatory product that can be explored for pharmacological purposes.
Resumo:
Tese de Doutoramento em Engenharia Biomédica.
Resumo:
Flanging, die plate, tube forming, T-joint, punch, prehole geometry
Resumo:
Fluidized bed, spouted bed, distributor plate, drying, modeling