937 resultados para Packet Filter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anti-doping authorities have high expectations of the athlete steroidal passport (ASP) for anabolic-androgenic steroids misuse detection. However, it is still limited to the monitoring of known well-established compounds and might greatly benefit from the discovery of new relevant biomarkers candidates. In this context, steroidomics opens the way to the untargeted simultaneous evaluation of a high number of compounds. Analytical platforms associating the performance of ultra-high pressure liquid chromatography (UHPLC) and the high mass-resolving power of quadrupole time-of-flight (QTOF) mass spectrometers are particularly adapted for such purpose. An untargeted steroidomic approach was proposed to analyse urine samples from a clinical trial for the discovery of relevant biomarkers of testosterone undecanoate oral intake. Automatic peak detection was performed and a filter of reference steroid metabolites mass-to-charge ratio (m/z) values was applied to the raw data to ensure the selection of a subset of steroid-related features. Chemometric tools were applied for the filtering and the analysis of UHPLC-QTOF-MS(E) data. Time kinetics could be assessed with N-way projections to latent structures discriminant analysis (N-PLS-DA) and a detection window was confirmed. Orthogonal projections to latent structures discriminant analysis (O-PLS-DA) classification models were evaluated in a second step to assess the predictive power of both known metabolites and unknown compounds. A shared and unique structure plot (SUS-plot) analysis was performed to select the most promising unknown candidates and receiver operating characteristic (ROC) curves were computed to assess specificity criteria applied in routine doping control. This approach underlined the pertinence to monitor both glucuronide and sulphate steroid conjugates and include them in the athletes passport, while promising biomarkers were also highlighted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of liquid-crystal panels for use in commercial equipment has been aimed at improving the pixel resolution and the display efficiency. These improvements have led to a reduction in the thickness of such devices, among other outcomes, that involves a loss in phase modulation. We propose a modification of the classical phase-only filter to permit displays in VGA liquid-crystal panels with a constant amplitude modulation and less than a 2¿(PI) phase modulation. The method was tested experimentally in an optical setup.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most important problems in optical pattern recognition by correlation is the appearance of sidelobes in the correlation plane, which causes false alarms. We present a method that eliminate sidelobes of up to a given height if certain conditions are satisfied. The method can be applied to any generalized synthetic discriminant function filter and is capable of rejecting lateral peaks that are even higher than the central correlation. Satisfactory results were obtained in both computer simulations and optical implementation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The expansion dynamics of the ablation plume generated by KrF laser irradiation of hydroxyapatite targets in a 0.1 mbar water atmosphere has been studied by fast intensified charge coupled device imaging with the aid of optical bandpass filters. The aim of the filters is to isolate the emission of a single species, which allows separate analysis of its expansion. Images obtained without a filter revealed two emissive components in the plume, which expand at different velocities for delay times of up to 1.1 ¿s. The dynamics of the first component is similar to that of a spherical shock wave, whereas the second component, smaller than the first, expands at constant velocity. Images obtained through a 520 nm filter show that the luminous intensity distribution and evolution of emissive atomic calcium is almost identical to those of the first component of the total emission and that there is no contribution from this species to the emission from the second component of the plume. The analysis through a 780 nm filter reveals that atomic oxygen partially diffuses into the water atmosphere and that there is a contribution from this species to the emission from the second component. The last species studied here, calcium oxide, was analyzed by means of a 600 nm filter. The images revealed an intensity pattern more complex than those from the atomic species. Calcium oxide also contributes to the emission from the second component. Finally, all the experiments were repeated in a Ne atmosphere. Comparison of the images revealed chemical reactions between the first component of the plume and the water atmosphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neuronal oscillations are an important aspect of EEG recordings. These oscillations are supposed to be involved in several cognitive mechanisms. For instance, oscillatory activity is considered a key component for the top-down control of perception. However, measuring this activity and its influence requires precise extraction of frequency components. This processing is not straightforward. Particularly, difficulties with extracting oscillations arise due to their time-varying characteristics. Moreover, when phase information is needed, it is of the utmost importance to extract narrow-band signals. This paper presents a novel method using adaptive filters for tracking and extracting these time-varying oscillations. This scheme is designed to maximize the oscillatory behavior at the output of the adaptive filter. It is then capable of tracking an oscillation and describing its temporal evolution even during low amplitude time segments. Moreover, this method can be extended in order to track several oscillations simultaneously and to use multiple signals. These two extensions are particularly relevant in the framework of EEG data processing, where oscillations are active at the same time in different frequency bands and signals are recorded with multiple sensors. The presented tracking scheme is first tested with synthetic signals in order to highlight its capabilities. Then it is applied to data recorded during a visual shape discrimination experiment for assessing its usefulness during EEG processing and in detecting functionally relevant changes. This method is an interesting additional processing step for providing alternative information compared to classical time-frequency analyses and for improving the detection and analysis of cross-frequency couplings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The observation that real complex networks have internal structure has important implication for dynamic processes occurring on such topologies. Here we investigate the impact of community structure on a model of information transfer able to deal with both search and congestion simultaneously. We show that networks with fuzzy community structure are more efficient in terms of packet delivery than those with pronounced community structure. We also propose an alternative packet routing algorithm which takes advantage of the knowledge of communities to improve information transfer and show that in the context of the model an intermediate level of community structure is optimal. Finally, we show that in a hierarchical network setting, providing knowledge of communities at the level of highest modularity will improve network capacity by the largest amount.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Second Hand Tobacco Smoke (SHTS) or Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of collected nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GC-TSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as the reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for non-smokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers, we can confirm the use of the CE concept for estimating exposure to ETS. The regional CIPRET (Center of information and prevention of the addiction to smoking) of different cantons (Valais (VS), Vaud (VD), Neuchâtel (NE) and Fribourg (FR)) are going to organize a big campaign on the subject of the passive addiction to smoking. This campaign took place in 2007-2008 and has for objective to inform clearly the Swiss population of the dangerousness of the passive smoke. More than 3'900 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva was also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study. This study, unique in Switzerland, has established a base map on the population's exposure to SHTS. It underscored the fact that all the Swiss people involved in this campaign (N=1241) is exposed to passive smoke, from <0.2 cig/d (10.8%), 1-2 to more than 10 cig/d (89.2%). In the area of high exposure (15-38 cig/d), are the most workers in public restaurant, cafe, bar, disco. By monitoring ETS tracer nicotine and its biomarkers, salivary nicotine and cotinine, it is demonstrated that the MoNIC badge can serve as indicator of CE passive smoking. The MoNIC badge, accompanied with content of salivary nicotine/cotinine can serve as a tool of evaluation of the ETS passive smoking and contributes to supply useful data for future epidemiological studies. It is also demonstrated that the salivary nicotine (without stimulation) is a better biomarker of ETS exposure than cotinine.