991 resultados para Outlier detection
Resumo:
Chlamydia serology is indicated to investigate etiology of miscarriage, infertility, pelvic inflammatory disease, and ectopic pregnancy. Here, we assessed the reliability of a new automated-multiplex immunofluorescence assay (InoDiag test) to detect specific anti-C. trachomatis immunoglobulin G. Considering immunofluorescence assay (IF) as gold standard, InoDiag tests exhibited similar sensitivities (65.5%) but better specificities (95.1%-98%) than enzyme-linked immunosorbent assays (ELISAs). InoDiag tests demonstrated similar or lower cross-reactivity rates when compared to ELISA or IF.
Resumo:
Whereas the reduction of transfusion related viral transmission has been a priority during the last decade, bacterial infection transmitted by transfusion still remains associated to a high morbidity and mortality, and constitutes the most frequent infectious risk of transfusion. This problem especially concerns platelet concentrates because of their favorable bacterial growth conditions. This review gives an overview of platelet transfusion-related bacterial contamination as well as on the different strategies to reduce this problem by using either bacterial detection or inactivation methods.
Resumo:
BACKGROUND: Cytomegalovirus (CMV) infection is associated with significant morbidity and mortality in transplant recipients. Resistance against ganciclovir is increasingly observed. According to current guidelines, direct drug resistance testing is not always performed due to high costs and work effort, even when resistance is suspected. OBJECTIVES: To develop a more sensitive, easy applicable and cost-effective assay as proof of concept for direct drug resistance testing in CMV surveillance of post-transplant patients. STUDY DESIGN: Five consecutive plasma samples from a heart transplant patient with a primary CMV infection were analyzed by quantitative real-time polymerase chain reaction (rtPCR) as a surrogate marker for therapy failure, and by direct drug resistance detection assays such as Sanger sequencing and the novel primer extension (PEX) reaction matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) based method. RESULTS: This report demonstrates that PEX reaction followed by MALDI-TOF analysis detects the A594V mutation, encoding ganciclovir resistance, ten days earlier compared to Sanger sequencing and more than 30 days prior to an increase in viral load. CONCLUSION: The greatly increased sensitivity and rapid turnaround-time combined with easy handling and moderate costs indicate that this procedure could make a major contribution to improve transplantation outcomes.
Resumo:
The objective of this study was to evaluate the contribution of ultrasound scanning to the prenatal detection of trisomy 21 in a large unselected European population. Data from 19 congenital malformation registers in 11 European countries were included. The prenatal ultrasound screening programs in the countries ranged from no routine screening to three ultrasound investigations per patient. Routine serum screening was offered in four of the 11 countries and routine screening on the basis of maternal age amniocentesis in all. The results show that overall 53% of cases of trisomy 21 were detected prenatally with a range from 3% in Lithuania to 88% in Paris. Ninety-eight percent of women whose babies were diagnosed before 24 weeks gestation chose to terminate the pregnancy. Centres/countries that offer serum screening do not have a significantly higher detection rate of trisomy 21 when compared to those that offer maternal age amniocentesis and anomaly scanning only. Fifty percent of trisomy 21 cases were born to women aged 35 years or more. In conclusions, second trimester ultrasound plays an important role in the prenatal diagnosis of trisomy 21. Of those cases prenatally diagnosed, 64% of cases in women <35 years and 36% of those in women >or=35 years were detected because of an ultrasound finding. Ultrasound soft markers accounted for 84% of the scan diagnoses. There is evidence of increasing maternal age across Europe with 50% of cases of trisomy 21 born to women aged 35 years or more.
Resumo:
Source: Description: pKM-19 is a 1.0 kb EcoRI human genomic fragment inserted in pUC13, that detects a Scrfl (CC/NGG) RFLP (1, 2). We report here the primer sequences suitable for the detection of this RFLP by PCR...
Resumo:
Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.
Resumo:
Ammonia gas detection by pure and catalytically modified WO3 based gas sensor was analysed. The sensor response of pure WO3 to NH3 was not only rather low but also presented an abnormal behaviour, probably due to the unselective oxidation of ammonia to NOx. Copper and vanadium were introduced in different concentrations and the resulting material was annealed at different temperatures in order to improve the sensing properties for NH3 detection. The introduction of copper and vanadium as catalytic additives improved the response to NH3 and also eliminated the abnormal behaviour. Possible mechanisms of NH3 reaction over these materials are discussed. Sensor responses to other gases like NO2 or CO and the interference of humidity on ammonia detection were also analysed so as to choose the best sensing element.
Resumo:
Leakage detection is an important issue in many chemical sensing applications. Leakage detection hy thresholds suffers from important drawbacks when sensors have serious drifts or they are affected by cross-sensitivities. Here we present an adaptive method based in a Dynamic Principal Component Analysis that models the relationships between the sensors in the may. In normal conditions a certain variance distribution characterizes sensor signals. However, in the presence of a new source of variance the PCA decomposition changes drastically. In order to prevent the influence of sensor drifts the model is adaptive and it is calculated in a recursive manner with minimum computational effort. The behavior of this technique is studied with synthetic signals and with real signals arising by oil vapor leakages in an air compressor. Results clearly demonstrate the efficiency of the proposed method.
Resumo:
Contamination with arsenic is a recurring problem in both industrialized and developing countries. Drinking water supplies for large populations can have concentrations much higher than the permissible levels (for most European countries and the United States, 10 μg As per L; elsewhere, 50 μg As per L). Arsenic analysis requires high-end instruments, which are largely unavailable in developing countries. Bioassays based on genetically engineered bacteria have been proposed as suitable alternatives but such tests would profit from better standardization and direct incorporation into sensing devices. The goal of this work was to develop and test microfluidic devices in which bacterial bioreporters could be embedded, exposed and reporter signals detected, as a further step towards a complete miniaturized bacterial biosensor. The signal element in the biosensor is a nonpathogenic laboratory strain of Escherichia coli, which produces a variant of the green fluorescent protein after contact to arsenite and arsenate. E. coli bioreporter cells were encapsulated in agarose beads and incorporated into a microfluidic device where they were captured in 500 × 500 μm(2) cages and exposed to aqueous samples containing arsenic. Cell-beads frozen at -20 °C in the microfluidic chip retained inducibility for up to a month and arsenic samples with 10 or 50 μg L(-1) could be reproducibly discriminated from the blank. In the 0-50 μg L(-1) range and with an exposure time of 200 minutes, the rate of signal increase was linearly proportional to the arsenic concentration. The time needed to reliably and reproducibly detect a concentration of 50 μg L(-1) was 75-120 minutes, and 120-180 minutes for a concentration of 10 μg L(-1).
Resumo:
Paul Ehrlich's inspired concept of 'magic bullets' for the cure of diseases has been revitalized by recent advances in immunology1. In particular, the development of cell fusion technology allowing the production of monoclonal antibodies (Mabs) with exquisite specificities2 triggered new hopes that we may now have the perfect carrier molecules with which to deliver cytotoxic drugs3 or toxins4 to the hidden cancer cells. This article reviews data on one aspect of the magic bullet concept, the use of radiolabelled antibodies as tracers for tumour localization. It will also discuss the very recent clinical use of 131I-labelled Mabs against carcinoembryonic antigen (CEA)5 to detect carcinoma either by conventional external photoscanning or by single photon emission computerized tomography (SPELT). This alliance of the most modern tools from immunology (Mabs) and nuclear medicine (SPELT) appears promising as a way to improve the sensitivity of 'immunoscintigraphy'. However, this approach is not yet ready, for widespread clinical use.
Resumo:
The usefulness and limitations of the carcinoembryonic antigen (C.E.A.) radioimmunoassay for the evaluation of tumour resection and for the detection of tumour relapse were studied in patients with large-bowel carcinoma. The level of plasma-C.E.A. was determined before any treatment in a group of 101 patients with histologically proven adenocarcinoma of the colon and rectum. 71% of all patients and 63% of cases with localised tumour (Dukes A and B) had a preoperative C.E.A. value of 5 ng. per ml. or higher. This limit was reached by only 1 of 90 apparently healthy, non-smoking blood-donors. Among 45 patients for whom a complete tumour resection was reported, all patients except 5 showed a drop of C.E.A. to normal values after surgery. The 5 patients whose C.E.A. did not fall to below 5 ng. per ml. showed a subsequent rise in C.E.A. level and were all found later to have a tumour relapse. The results indicate that an incomplete drop of circulating C.E.A. level one month after surgery has a bad prognostic significance. 22 of these patients were followed up by repeated C.E.A. radioimmunoassay for several months after surgery. 8 showed a progressive increase in C.E.A. levels preceding clinical diagnosis of tumour relapse by two to ten months. 6 other patients showed a moderate increase in C.E.A. levels, suggesting a tumour relapse not yet clinically detectable. The remaining 8 patients showed no increase in C.E.A. level above 5 ng. per ml. and no clinical symptoms of relapse. The results demonstrate that relapses of colon and rectum carcinoma can be detected by increased C.E.A. levels months before the appearance of any clinical evidence.
Resumo:
Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.
Resumo:
The paracaspase MALT1 is a Cys-dependent, Arg-specific protease that plays an essential role in the activation and proliferation of lymphocytes during the immune response. Oncogenic activation of MALT1 is associated with the development of specific forms of B-cell lymphomas. Through specific cleavage of its substrates, MALT1 controls various aspects of lymphocyte activation, including the activation of transcriptional pathways, the stabilization of mRNAs, and an increase in cellular adhesion. In lymphocytes, the activity of MALT1 is tightly controlled by its inducible monoubiquitination, which promotes the dimerization of MALT1. Here, we describe both in vitro and in vivo assays that have been developed to assess MALT1 activity.
Resumo:
Short-TE MRS has been proposed recently as a method for the in vivo detection and quantification of γ-aminobutyric acid (GABA) in the human brain at 3 T. In this study, we investigated the accuracy and reproducibility of short-TE MRS measurements of GABA at 3 T using both simulations and experiments. LCModel analysis was performed on a large number of simulated spectra with known metabolite input concentrations. Simulated spectra were generated using a range of spectral linewidths and signal-to-noise ratios to investigate the effect of varying experimental conditions, and analyses were performed using two different baseline models to investigate the effect of an inaccurate baseline model on GABA quantification. The results of these analyses indicated that, under experimental conditions corresponding to those typically observed in the occipital cortex, GABA concentration estimates are reproducible (mean reproducibility error, <20%), even when an incorrect baseline model is used. However, simulations indicate that the accuracy of GABA concentration estimates depends strongly on the experimental conditions (linewidth and signal-to-noise ratio). In addition to simulations, in vivo GABA measurements were performed using both spectral editing and short-TE MRS in the occipital cortex of 14 healthy volunteers. Short-TE MRS measurements of GABA exhibited a significant positive correlation with edited GABA measurements (R = 0.58, p < 0.05), suggesting that short-TE measurements of GABA correspond well with measurements made using spectral editing techniques. Finally, within-session reproducibility was assessed in the same 14 subjects using four consecutive short-TE GABA measurements in the occipital cortex. Across all subjects, the average coefficient of variation of these four GABA measurements was 8.7 ± 4.9%. This study demonstrates that, under some experimental conditions, short-TE MRS can be employed for the reproducible detection of GABA at 3 T, but that the technique should be used with caution, as the results are dependent on the experimental conditions. Copyright © 2013 John Wiley & Sons, Ltd.