996 resultados para Optical-lattice potential
Resumo:
Background/aim Regulation of apoptosis in non-alcoholic fatty liver disease (NAFLD) has been a theme of growing debate. Although no other study assessed the role of survivin in NAFLD, its expression has been reported in hepatic carcinogenesis because of other aetiological factors with relevant discrepancies. The aim of this study was to assess the pattern of survivin immunoexpression by tissue microarray along the whole spectrum of NAFLD, including non-alcoholic steatohepatitis (NASH)-related hepatocelular carcinoma (HCC). Methods Liver biopsies from 56 patients with NAFLD were evaluated: 18 with steatosis, 21 non-cirrhotic NASH, 10 NASH-related cirrhosis, seven NASH-related HCC, as compared with 71 HCC related to other causes and with 12 normal livers. Results Survivin immunoexpression in NAFLD was restricted to cytoplasm and was found to be progressively lower in advanced stages, including cirrhosis and HCC: steatosis vs NASH-related cirrhosis (P=0.0243); steatosis vs NASH-related HCC (P=0.0010); NASH vs NASH-related cirrhosis (P=0.0318); and NASH vs NASH-related HCC (P=0.0007), thus suggesting a deregulation of apoptosis from NAFLD towards HCC. Interestingly, survivin immunoreactivity in NASH-related HCC was also found to be significantly lower than in HCC related to other causes (P < 0.05). Remarkably, nuclear staining for survivin was not detected in any case of NAFLD, contrasting to its presence in all other cases of HCC. Conclusions Survivin immunoexpression in NASH-related HCC is herein originally found substantially different than in HCC related to other causes, thus requiring further studies to elucidate the role of survivin in human NAFLD progression.
Resumo:
In Brazil, sugarcane fields are often burned to facilitate manual harvesting, and this burning causes environmental pollution from the large amounts of soot released into the atmosphere. This material contains numerous organic compounds such as PAHs. In this study, the concentrations of PAHs in two particulate-matter fractions (PM(2.5) and PM(10)) in the city of Araraquara (SE Brazil, with around 200,000 inhabitants and surrounded by sugarcane plantations) were determined during the sugarcane harvest (HV) and non-harvest (NHV) seasons in 2008 and 2009. The sampling strategy included four campaigns, with 60 samples in the NHV season and 220 samples in the HV season. The PM(2.5) and PM(10) fractions were collected using a dichotomous sampler (10 L min(-1), 24 h) with Teflon (TM) filters. The filter sets were extracted (ultrasonic bath with hexane/acetone (1:1 v/v)) and analyzed by HPLC/Fluorescence. The median concentration for total PAHs (PM(2.5) in 2009) was 0.99 ng m(-3) (NHV) and 3.3 ng m(-3) (HV). In the HV season, the total concentration of carcinogenic PAHs (benz(a)anthracene, benzo(b)fluoranthene, benzo(k)fluoranthene, and benzo(a)pyrene) was 5 times higher than in the NHV season. B(a)P median concentrations were 0.017 ng m(-3) and 0.12 ng m(-3) for the NHV and HV seasons, respectively. The potential cancer risk associated with exposure through inhalation of these compounds was estimated based on the benzo[a]pyrene toxic equivalence (BaP(eq)), where the overall toxicity of a PAR mixture is defined by the concentration of each compound multiplied by its relative toxic equivalence factor (TEF). BaP(eq) median (2008 and 2009 years) ranged between 0.65 and 1.0 ng m(-3) and 1.2-1.4 ng m(-3) for the NHV and HV seasons, respectively. Considering that the maximum permissible BaPeq in ambient air is 1 ng m(-3), related to the increased carcinogenic risk, our data suggest that the level of human exposure to PAHs in cities surrounded by sugarcane crops where the burning process is used is cause for concern. (C) 2010 Published by Elsevier Ltd.
Resumo:
Overexpression of kallikrein 7, a proteolytic enzyme important for epithelial cell shedding, may be causally involved in carcinogenesis, particularly in tumor metastasis and invasion. In this study, we have evaluated hK7 (human kallikrein 7) protein levels by immunohistochemistry in 367 cervical histological samples including 35 cases of cervicitis, 31 low-grade cervical intraepithelial neoplasia, 51 high-grade cervical intraepithelial neoplasia (H-SIL), 197 squamous cervical carcinomas (SCC) and 53 cervical adenocarcinomas. We have observed that hK7 staining increased with the severity of cervical disease. Intense hK7 staining was found in 15.2% of cervicitis samples, in contrast to 55% of H-SIL and 68% of SCC. Moreover, 92.5% of adenocarcinomas also exhibited intense hK7 staining. Differences in the expression of hK7 could potentially be used as a biomarker for the characterization of different stages of cervical disease.
Resumo:
PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516
Resumo:
Introduction. The hippocampal formation is a specific structure in the brain where neurogenesis occurs throughout adulthood and in which the neuronal cell loss causes various demential states. The main goal of this study was to verify whether fetal neural progenitor cells (NPCs) from transgenic rats expressing green fluorescent protein (GFP) retain the ability to differentiate into neuronal cells and to integrate into the hippocampal circuitry after transplantation. Methods. NPCs were isolated from E14 (gestational age: 14 days postconception) transgenic-Lewis and wild-type Sprague-Dawley rat embryos. Wild-type and transgenic cells were expanded and induced to differentiate into a neuronal lineage in vitro. Immunocytochemical and electrophysiological analysis were performed in both groups. GFP-expressing cells were implanted into the hippocampus and recorded electrophysiologically 3 months thereafter. Immunohistochemical analysis confirmed neuronal differentiation, and the yield of neuronal cells was determined stereologically. Results. NPCs derived from wild-type and transgenic animals are similar regarding their ability to generate neuronal cells in vitro. Neuronal maturity was confirmed by immunocytochemistry and electrophysiology, with demonstration of voltage-gated ionic currents, firing activity, and spontaneous synaptic currents. GFP-NPCs were also able to differentiate into mature neurons after implantation into the hippocampus, where they formed functional synaptic contacts. Conclusions. GFP-transgenic cells represent an important tool in transplantation studies. Herein, we demonstrate their ability to generate functional neurons both in vitro and in vivo conditions. Neurons derived from fetal NPCs were able to integrate into the normal hippocampal circuitry. The high yield of mature neurons generated render these cells important candidates for restorative approaches based on cell therapy.
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.
Resumo:
PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716
Resumo:
P>We have developed a two-step PCR assay that amplifies a region of the ceja-1 sequence that is specific for virulent strains of Paracoccidioides brasiliensis. An internal region of the ceja-1 sequence was chosen for designing primers that were utilised in a single tube heminested PCR protocol to amplify DNA from six virulent strains. PCR specificity was determined by the absence of amplified products with genomic DNA from four non-virulent strains of P. brasiliensis and from eight fungal pathogens, one bacterium, two protozoa, one worm and mouse and human genomic DNA (leucocytes). The fact that the PCR product was only obtained with the genetic material from virulent isolates of P. brasiliensis suggested that this partial amplified sequence might be a marker of virulence for this fungus. The diagnostic potential of this PCR was confirmed by the successful amplification of this fragment with genomic DNA obtained in lymph node aspirate from a patient with paracoccidioidomycosis.
Resumo:
Replication-defective adenoviruses have been utilized as candidate HIV vaccine vectors Few studies have described the international epidemiology of pre-existing immunity to adenoviruses We enrolled 1904 participants in a cross-sectional serological survey at seven sites in Africa, Brazil, and Thailand to assess neutralizing antibodies (NA) for adenovirus types Ad5, Ad6, Ad26 and Ad36 Clinical trial samples were used to assess NA titers from the US and Europe The proportions of participants that were negative were 14 8%(Ad5), 31 5%(Ad6),41 2%(Ad26) and 53.6% (Ad36) Adenovirus NA titers varied by geographic location and were higher in non-US and non-European settings, especially Thailand In multivariate logistic regression analysis, geographic setting (non-US and non-European settings) was statistically significantly associated with having higher Ad5 titers, participants from Thailand had the highest odds of having high Ad5 titers (adjusted OR = 3 53,95% CI 224,557) Regardless of location. titers of Ad5NA were the highest and Ad36 NA were the lowest Coincident Ad5/6 titers were lower than either Ad5 or Ad6 titers alone Understanding pre-existing immunity to candidate vaccine vectors may contribute to the evaluation of vaccines in international populations (C) 2009 Published by Elsevier Ltd
Resumo:
Introduction: The delay in the diagnosis of infections can be deleterious in renal transplant recipients. Thus, laboratory tests leading to an earlier diagnosis are very useful for these patients. Purpose: To assess the behavior of C-reactive protein (CRP) in renal transplant recipients with a diagnosis of cytomegalovirus (CMV) infection, tuberculosis (TB) and bacterial infection (BI). Methods: A retrospective analysis of 129 patients admitted at our hospital, from 2006 to 2008 because of CMV, TB or BI, was carried out. Appropriate statistical analysis was done and values were expressed as medians, range. Results: When CRP levels were compared among the groups with CMV disease, TB or BI, the group with CMV disease presented lower levels of CRP (18.4 mg/L, 0.28-44 mg/L) than the TB and BI (p < 0.05) groups. The area under the receiver-operating characteristics curve, distinguishing CMV disease from TB/BI, was 0.96 (p < 0.0001), resulting in 100% sensitivity and 90.63% specificity to detect CMV disease when CRP < 44.5 mg/L. The subgroup analysis of CMV infection showed increasing levels of CRP (0.28, 16 and 29.5 mg/L) in the asymptomatic, symptomatic and invasive disease subgroups, respectively (p < 0.05). Conclusion: The measurement of CRP levels may be a useful tool for differentiating CMV infection from the other types (bacterial or TB) of infection in kidney transplant recipients.
Resumo:
PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093
Resumo:
Models of warped extra dimensions with custodial symmetry usually predict the existence of a light Kaluza-Klein fermion arising as a partner of the right-handed top quark, sometimes called light custodians which we will denote (b) over tilde (R). The production of these particles at the LHC can give rise to multi-W events which could be observed in same-sign dilepton channels, but its mass reconstruction is challenging. In this paper we study the possibility of finding a signal for the pair production of this new particle at the LHC focusing on a rarer, but cleaner decay mode of a light custodian into a Z boson and a b-quark. In this mode it would be possible to reconstruct the light custodian mass. In addition to the dominant standard model QCD production processes, we include the contribution of a Kaluza-Klein gluon first mode. We find that (b) over tilde (R) stands out from the background as a peak in the bZ invariant mass. However, when taking into account only the electronic and muonic decay modes of the Z boson and b-tagging efficiencies, the LHC will have access only to the very light range of masses, m((b) over tilde) = O(500) GeV.