993 resultados para OPTICAL-DETECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eradication of code smells is often pointed out as a way to improve readability, extensibility and design in existing software. However, code smell detection remains time consuming and error-prone, partly due to the inherent subjectivity of the detection processes presently available. In view of mitigating the subjectivity problem, this dissertation presents a tool that automates a technique for the detection and assessment of code smells in Java source code, developed as an Eclipse plugin. The technique is based upon a Binary Logistic Regression model that uses complexity metrics as independent variables and is calibrated by expert‟s knowledge. An overview of the technique is provided, the tool is described and validated by an example case study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to estimate the frequency of infection by Cryptosporidium spp and other intestinal parasites in dehydrated children with gastroenteritis who were admitted to a pediatric hospital. Stool examinations from 218 children were performed. Cryptosporidium spp was identified in eighteen out of 193 stool samples (9.3%) subjected to safranin-methylene blue staining. Giardia lamblia was detected in ten out of 213 (4.7%) samples examined via the direct or Ritchie methods. Other parasites identified were Ascaris lumbricoides (4.2%), Blastocystis hominis (1.4%), Entamoeba coli (0.9%), Entamoeba histolytica/Entamoeba dispar (0.5%), Endolimax nana (0.5%), Trichuris trichiura (0.5%) and Enterobius vermicularis (0.5%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibrio cholerae has been sporadically isolated from rivers in Tucumán, Argentina, since the outbreak in 1991. The aim of this study was to determine the environmental reservoir of the bacterium in these rivers, assessing the presence of Vibrio cholerae non-O1 and O1 (the latter both in its viable culturable and non culturable state) and its relationship to environmental physicochemical variables. 18 water samplings were collected in the Salí River (in Canal Norte and Banda) and the Lules River between 2003 and 2005. Physical-chemical measurements (pH, water temperature, electrical conductivity and dissolved oxygen) were examined. Vibrio cholerae was investigated with conventional culture methods and with Direct Immunofluorescence (DFA-VNC) in order to detect viable non culturable organisms. All isolated microorganisms corresponded to Vibrio cholerae non-O1 and non-O139 (Lules 26%, Canal Norte 33% and Banda 41%). The majority was found during spring and summer and correlated with temperature and pH. Non culturable Vibrio cholerae O1 was detected year round in 38 of the 54 water samples analyzed. Application of the Pearson correlation coefficient revealed that there was no relationship between positive immunofluorescence results and environmental physicochemical parameters. Genes coding for somatic antigen O1 were confirmed in all DFA-VNC-positive samples, whereas the virulence-associated ctxA and tcpA genes were confirmed in 24 samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part of this thesis will be published in the following: Gomes, B.C., Santos, B. 2015. Methods for studying microRNAs expression and their targets in formalin-fixed, paraffin-embedded (FFPE) breast cancer tissues. In Methods in Molecular Biology: Cancer Drug Resistance (Rueff, J. & Rodrigues, A.S. eds), Springer Protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro/nano wrinkled patterns on cross-linked urethane/urea polymeric flexible free standing films with two soft segments, polypropylene oxide and polybutadiene, can be induced by UV-irradiation. The ability to write/erase these 3D structures, in a controlled manner, is the main focus of this work. The imprinting of the wrinkled structures was accomplished by swelling in an appropriate solvent followed by drying the membranes after the cross-linking process and UV irradiation. The surface tailoring of the elastomeric membranes was imaged by optical microscopy, scanning electronic microscopy and by atomic force microscopy. To erase the wrinkled structures the elastomers were swollen. The swelling as well as the sol/gel fraction and the UV radiation were tuned in order to control the wrinkles characteristics. It was found that the wrinkles wavelength, in the order of microns (1±0,25μm), was stamped by the UV radiation intensity and exposure time while the wrinkles' amplitude, in the order of nanometers (150-450 nm), was highly dependent on the swelling and sol/gel fraction. A prototype for volatile organic compounds detection was developed taking advantage of the unique 3D micro/nano wrinkles features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosis of human herpesvirus-7 active infection in transplant patients has proved difficult, because this virus is ubiquitous and can cause persistent infections in the host. The significance of viral DNA detected in leukocytes by PCR is unclear and cross-reaction in serological tests may occur. This study aimed to evaluate nested-PCR to detect human herpesvirus-7 active infection in liver transplant recipients compared to healthy individuals. human herpesvirus-7 nested-PCR was performed on leukocytes and sera of 53 healthy volunteers and sera of 29 liver transplant recipients. In healthy volunteers, human herpesvirus-7 was detected in 28.3% of leukocytes and 0% of serum. human herpesvirus-7 was detected in sera of 48.2% of the liver transplant recipients. Nested-PCR on DNA extracted from leukocytes detected latent infection and the study suggests that nested-PCR performed on serum could be useful to detect human herpesvirus-7 active infection in liver transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this thesis was the development of a gold nanoparticle-based methodology for detection of DNA adducts as biomarkers, to try and overcome existing drawbacks in currently employed techniques. For this objective to be achieved, the experimental work was divided in three components: sample preparation, method of detection and development of a model for exposure to acrylamide. Different techniques were employed and combined for de-complexation and purification of DNA samples (including ultrasonic energy, nuclease digestion and chromatography), resulting in a complete protocol for sample treatment, prior to detection. The detection of alkylated nucleotides using gold nanoparticles was performed by two distinct methodologies: mass spectrometry and colorimetric detection. In mass spectrometry, gold nanoparticles were employed for laser desorption/ionisation instead of the organic matrix. Identification of nucleotides was possible by fingerprint, however no specific mass signals were denoted when using gold nanoparticles to analyse biological samples. An alternate method using the colorimetric properties of gold nanoparticles was employed for detection. This method inspired in the non-cross-linking assay allowed the identification of glycidamide-guanine adducts and DNA adducts generated in vitro. For the development of a model of exposure, two different aquatic organisms were studies: a goldfish and a mussel. Organisms were exposed to waterborne acrylamide, after which mortality was recorded and effect concentrations were estimated. In goldfish, both genotoxicity and metabolic alterations were assessed and revealed dose-effect relationships of acrylamide. Histopathological alterations were verified primarily in pancreatic cells, but also in hepatocytes. Mussels showed higher effect concentrations than goldfish. Biomarkers of oxidative stress, biotransformation and neurotoxicity were analysed after prolonged exposure, showing mild oxidative stress in mussel cells, and induction of enzymes involved in detoxification of oxygen radicals. A qualitative histopathological screening revealed gonadotoxicity in female mussels, which may present some risk to population equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyses financial data using the result characterization of a self-organized neural network model. The goal was prototyping a tool that may help an economist or a market analyst to analyse stock market series. To reach this goal, the tool shows economic dependencies and statistics measures over stock market series. The neural network SOM (self-organizing maps) model was used to ex-tract behavioural patterns of the data analysed. Based on this model, it was de-veloped an application to analyse financial data. This application uses a portfo-lio of correlated markets or inverse-correlated markets as input. After the anal-ysis with SOM, the result is represented by micro clusters that are organized by its behaviour tendency. During the study appeared the need of a better analysis for SOM algo-rithm results. This problem was solved with a cluster solution technique, which groups the micro clusters from SOM U-Matrix analyses. The study showed that the correlation and inverse-correlation markets projects multiple clusters of data. These clusters represent multiple trend states that may be useful for technical professionals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: This was a prospective study that included women seen in the obstetrics and gynecology sector of Hospital das Clínicas, Federal University of Goiás, in Goiânia, State of Goiás, with the aim of detecting rotaviruses, adenoviruses, caliciviruses and astroviruses. Eighty-four women participated in the study and from these, 314 fecal samples were collected. Out of all of the women, 29 were seropositive for HIV and 55 were seronegative, and 45 and 39 were pregnant and non-pregnant, respectively. METHODS: Fecal samples were collected from each woman once every two months over the period from July 2006 to June 2007, and they were screened for rotaviruses by means of polyacrylamide gel electrophoresis and immunoenzymatic assays, for caliciviruses and astroviruses by means of RT-PCR and for adenovirus by means of immunoenzymatic assays. The astroviruses were genotyped using nested PCR. RESULTS: Among the 84 patients, 19 (22.6%) were positive for either calicivirus (14/19) or astrovirus (6/19), while one women was positive for both viruses in fecal samples collected on different occasions. Most of the positive samples were collected during the months of July and August (astrovirus) and September and October (calicivirus). None of the samples analyzed was positive for rotavirus or adenovirus. Gastroenteric viruses were detected in 13/19 (68.4%) of the pregnant women, whether HIV-seropositive or not. CONCLUSIONS: The results from the present study showed that neither pregnancy nor HIV-seropositive status among the women increased the risk of infection by any of the gastroenteric viruses studied. This study presents data on gastroenteric virus detection among pregnant and/or HIV-positive women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Human herpesviruses are frequently associated with orofacial diseases in humans (HSV-1, EBV, CMV and HHV-8), some can also cause systemic disease (CMV and HHV-8). The transmission of these viruses occurs by contact with infected secretions, especially saliva. Human immunodeficiency virus infection is associated with an increased risk of HHVs and related diseases. METHODS: This work aimed to detect HSV-1, EBV, CMV and HHV-8 DNA in saliva of HIV-infected patients from Teresina, northeast Brazil, by PCR and compare these findings with age and sex matched HIV-seronegative individuals. RESULTS: No difference in prevalence was verified between HHV detection in the saliva of HIV-seropositive individuals and controls. The individual frequencies of these viruses in these two populations were different. HIV seropositivity correlated positively with the presence of CMV (OR: 18.2, p= 0.00032) and EBV (OR: 3.44, p= 0.0081). No association between CD4 counts and the prevalence of HHVs in the saliva was observed; however, a strong association was determined between seropositivity and the presence of multiple HHV DNAs in saliva (OR: 4.83, p = 0.0028). CONCLUSIONS: These findings suggest the asymptomatic salivary shedding of HHVs is a common event between HIV-seropositive and seronegative individuals from Teresina, Piauí, Brazil, and, especially for HIV-seropositive patients, saliva is a risk factor for the acquisition/transmission of multiple HHVs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Paracoccidioidomycosis is a systemic infection caused by Paracoccidioides brasiliensis. METHODS: In this study, a semi-nested PCR for paracoccidioidomycosis diagnosis was developed. The primers ITS1 and ITS4 were used in the first reaction, while the primers MJ03 and ITS1 primer were used in the second reaction. The semi-nested PCR was used to investigate biopsies of five patients with oral lesions that resembled paracoccidioidomycosis. RESULTS: The semi-nested PCR was positive for four samples and negative for a sample from a patient later diagnosed with leishmaniasis. CONCLUSIONS: The new semi-nested PCR describe is useful for paracoccidioidomycosis diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Human cytomegalovirus (HCMV) is often reactive in latently infected immunosuppressed patients. Accordingly, HCMV remains one of the most common infections following solid organ and hemopoietic stem cell transplantations, resulting in significant morbidity, graft loss and occasional mortality. The early diagnosis of HCMV disease is important in immunosuppressed patients, since in these individuals, preemptive treatment is useful. The objective of this study was to compare the performance of the in-house qualitative polymerase chain reaction (PCR) and pp65 antigenemia to HCMV infection in immunosuppressed patients in the Hospital de Clínicas of Porto Alegre (HCPA). METHODS: A total of 216 blood samples collected between August 2006 and January 2007 were investigated. RESULTS: Among the samples analyzed, 81 (37.5%) were HCMV-positive by PCR, while 48 (22.2%) were positive for antigenemia. Considering antigenemia as the gold standard, sensitivity, specificity, positive predictive values and negative predictive values for PCR were 87.5%, 76.8%, 51.8% and 95.5% respectively. CONCLUSIONS: These results demonstrated that qualitative PCR has high sensitivity and negative predictive value (NPV). Consequently PCR is especially indicated for the initial diagnosis of HCMV infection. In the case of preemptive treatment strategy, identification of patients at high-risk for HCMV disease is fundamental and PCR can be useful tool.