950 resultados para Multimodal prototype


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims at defending the necessity of creating applicationsfrom studies on discourse, so that applied linguistics becomes auseful tool for the society. This work explains briefly what reformulation connectors are and it shows the electronic prototype (than can be consulted by internet) of a tool designed to make the work of lexicographerseasy concerning the entrance of connectors in the dictionaries (ALCOR), by making emphasis on the theoretical base on which it is sustained and on the decisions of application that have been taken into account.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prognosis of patients who are admitted in a comatose state following successful resuscitation after cardiac arrest remains uncertain. Although the introduction of therapeutic hypothermia (TH) and improvements in post-resuscitation care have significantly increased the number of patients who are discharged home with minimal brain damage, short-term assessment of neurological outcome remains a challenge. The need for early and accurate prognostic predictors is crucial, especially since sedation and TH may alter the neurological examination and delay the recovery of motor response for several days. The development of additional tools, including electrophysiological examinations (electroencephalography and somatosensory evoked potentials), neuroimaging and chemical biomarkers, may help to evaluate the extent of brain injury in these patients. Given the extensive literature existing on this topic and the confounding effects of TH on the strength of these tools in outcome prognostication after cardiac arrest, the aim of this narrative review is to provide a practical approach to post-anoxic brain injury when TH is used. We also discuss when and how these tools could be combined with the neurological examination in a multimodal approach to improve outcome prediction in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When applying a Collaborative Learning Flow Pattern (CLFP) to structure sequences of activities in real contexts, one of the tasks is to organize groups of students according to the constraints imposed by the pattern. Sometimes,unexpected events occurring at runtime force this pre-defined distribution to be changed. In such situations, an adjustment of the group structures to be adapted to the new context is needed. If the collaborative pattern is complex, this group redefinitionmight be difficult and time consuming to be carried out in real time. In this context, technology can help on notifying the teacher which incompatibilitiesbetween the actual context and the constraints imposed by the pattern. This chapter presents a flexible solution for supporting teachers in the group organization profiting from the intrinsic constraints defined by a CLFPs codified in IMS Learning Design. A prototype of a web-based tool for the TAPPS and Jigsaw CLFPs and the preliminary results of a controlled user study are alsopresented as a first step towards flexible technological systems to support grouping tasks in this context.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This final year project presents the design principles and prototype implementation of BIMS (Biomedical Information Management System), a flexible software system which provides an infrastructure to manage all information required by biomedical research projects.The BIMS project was initiated with the motivation to solve several limitations in medical data acquisition of some research projects, in which Universitat Pompeu Fabra takes part. These limitations,based on the lack of control mechanisms to constraint information submitted by clinicians, impact on the data quality, decreasing it.BIMS can easily be adapted to manage information of a wide variety of clinical studies, not being limited to a given clinical specialty. The software can manage both, textual information, like clinical data (measurements, demographics, diagnostics, etc ...), as well as several kinds of medical images (magnetic resonance imaging, computed tomography, etc ...). Moreover, BIMS provides a web - based graphical user interface and is designed to be deployed in a distributed andmultiuser environment. It is built on top of open source software products and frameworks.Specifically, BIMS has been used to represent all clinical data being currently used within the CardioLab platform (an ongoing project managed by Universitat Pompeu Fabra), demonstratingthat it is a solid software system, which could fulfill requirements of a real production environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämä insinöörityö tehtiin ABB:n Pitäjänmäen konetehtaalle Tahtikoneet-tulosyksikölle. Työssä tutkittiin mahdollisuuksia valmistaa murtovakovyyhtejä kestomagneettituuligeneraattoreihin, joissa vakoluku on alle yhden. Työ tehtiin tutustumalla aluksi Pitäjänmäen konetehtaan käytössä oleviin vyyhden valmistus- ja käämintämenetelmiin. Lisäksi tutkittiin erilaisia mahdollisia murtovakovyyhden valmistusmenetelmiä, joista lupaavimpia myös kokeiltiin. Saatujen kokemusten pohjalta valittiin vyyhden valmistusmenetelmä, jonka mukaan valmistettiin koe-erä. Koe-erälle suoritettiin mittauksia, joilla varmistettiin niiden sähköinen kestävyys Työn tuloksena valitulla valmistusmenetelmällä valmistettiin vyyhdet prototyyppi tuuligeneraattorin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämän insinöörityön tarkoituksena on kehittää avaruusinstrumentti, joka on osa Euroopan avaruusjärjestön ESA:n ja Japanin avaruusjärjestön JAXA:n BepiColombo-yhteistyöhanketta. Satelliitti lähetetään Merkurius-planeetan kiertoradalle vuonna 2013. Avaruusaluksen matka Merkuriukseen kestää yhteensä kuusi vuotta ja on perillä vuonna 2019. Yksi BepiColombo-satelliitin tieteellisistä instrumenteista on Oxford Instruments Analytical Oy:n kehittämä SIXS-instrumentti (Solar Intensity X-ray and particle Spectrometer). Instrumentin tarkoituksena on mitata auringosta tulevaa röntgen- ja partikkelisäteilyä. Se toimii yhteistyössä Merkuriuksen pintaa mittaavan MIXS-instrumentin (Mercury Imaging X-ray Spectrometer) kanssa. Tuloksista pystytään analysoimaan ne alkuaineet, joista Merkuriuksen pinta koostuu. Työn alussa esitellään teoriataustaa alkuaineiden mittauksesta niiltä osin, kuin se tämän työn kannalta on tarpeellista. Työssä syvennytään tarkemmin auringosta tulevan säteilyn mittauksesta vastaavan instrumentin tekniikkaan ja mekaniikkasuunnitteluun. Instrumentin lämpöteknisestä suunnittelusta, värähtelymittauksista ja lujuusanalyysista on työhön sisällytetty pääasiat. Työn tuloksena on kehitetty instrumenttiin tulevan partikkelidetektorin prototyyppi sekä instrumenttikotelon malli. Lopullisen koon instrumenttikotelolle määrittää vaadittavan elektroniikan viemä tila. Mittalaitteen kehitystyö jatkuu Oxford Instruments Analytical Oy:ssä vuoteen 2011 saakka.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: To present the practical aspects of transcranial Doppler (TCD) and provide evidence supporting its use for the management of traumatic brain injury (TBI) patients. RECENT FINDINGS: TCD measures systolic, mean, and diastolic cerebral blood flow (CBF) velocities and calculates the pulsatility index from basal intracranial arteries. These variables reflect the brain circulation, provided there is control of potential confounding factors. TCD can be useful in patients with severe TBI to detect low CBF, for example, during intracranial hypertension, and to assess cerebral autoregulation. In the emergency room, TCD might complement brain computed tomography (CT) scan and clinical examination to screen patients at risk for further neurological deterioration after mild-to-moderate TBI. SUMMARY: The diagnostic value of TCD should be incorporated into other findings from multimodal brain monitoring and CT scan to optimize the bedside management of patients with TBI and help guide the choice of appropriate therapies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation focuses on the strategies consumers use when making purchase decisions. It is organized in two main parts, one centering on descriptive and the other on applied decision making research. In the first part, a new process tracing tool called InterActive Process Tracing (IAPT) is pre- sented, which I developed to investigate the nature of consumers' decision strategies. This tool is a combination of several process tracing techniques, namely Active Information Search, Mouselab, and retrospective verbal protocol. To validate IAPT, two experiments on mobile phone purchase de- cisions were conducted where participants first repeatedly chose a mobile phone and then were asked to formalize their decision strategy so that it could be used to make choices for them. The choices made by the identified strategies correctly predicted the observed choices in 73% (Experiment 1) and 67% (Experiment 2) of the cases. Moreover, in Experiment 2, Mouselab and eye tracking were directly compared with respect to their impact on information search and strategy description. Only minor differences were found between these two methods. I conclude that IAPT is a useful research tool to identify choice strategies, and that using eye tracking technology did not increase its validity beyond that gained with Mouselab. In the second part, a prototype of a decision aid is introduced that was developed building in particular on the knowledge about consumers' decision strategies gained in Part I. This decision aid, which is called the InterActive Choice Aid (IACA), systematically assists consumers in their purchase decisions. To evaluate the prototype regarding its perceived utility, an experiment was conducted where IACA was compared to two other prototypes that were based on real-world consumer decision aids. All three prototypes differed in the number and type of tools they provided to facilitate the process of choosing, ranging from low (Amazon) to medium (Sunrise/dpreview) to high functionality (IACA). Overall, participants slightly preferred the prototype of medium functionality and this prototype was also rated best on the dimensions of understandability and ease of use. IACA was rated best regarding the two dimensions of ease of elimination and ease of comparison of alternatives. Moreover, participants choices were more in line with the normatively oriented weighted additive strategy when they used IACA than when they used the medium functionality prototype. The low functionality prototype was the least preferred overall. It is concluded that consumers can and will benefit from highly functional decision aids like IACA, but only when these systems are easy to understand and to use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This review aims to present a consensus for optimal perioperative care in colonic surgery and to provide graded recommendations for items for an evidenced-based enhanced perioperative protocol. METHODS: Studies were selected with particular attention paid to meta-analyses, randomised controlled trials and large prospective cohorts. For each item of the perioperative treatment pathway, available English-language literature was examined, reviewed and graded. A consensus recommendation was reached after critical appraisal of the literature by the group. RESULTS: For most of the protocol items, recommendations are based on good-quality trials or meta-analyses of good-quality trials (quality of evidence and recommendations according to the GRADE system). CONCLUSIONS: Based on the evidence available for each item of the multimodal perioperative care pathway, the Enhanced Recovery After Surgery (ERAS) Society, International Association for Surgical Metabolism and Nutrition (IASMEN) and European Society for Clinical Nutrition and Metabolism (ESPEN) present a comprehensive evidence-based consensus review of perioperative care for colonic surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Different routes of postoperative analgesia may be used after cesarean section: systemic, spinal or epidural [1]. Although the efficacy of these alternative analgesic regimen has already been studied [2, 3], very few studies have compared patients' satisfaction between them. Methodology: After ethical committee acceptation, 100 ASA 1 patients scheduled for an elective cesarean section were randomized in 4 groups. After a standardized spinal anesthesia (hyperbaric bupivacaine 10 mg and fentanyl 20 μg), each group had a different postoperative analgesic regimen: - Group 1: oral paracetamol 4x1 g/24 h, oral ibuprofene 3x600 mg/24 h and subcutaneous morphine on need (0.1 mg/kg 6x/24 h) - Group 2: intrathecal morphine (100 μg) and then same as Group 1 - Group 3: oral paracetamol 4x1 g/24 h, oral ibuprofene 3x600 mg/24 h and PCEA with fentanyl 5 μg/ml epidural solution - Group 4: oral paracetamol 4x1g/24 h, oral ibuprofene 3x600 mg/ 24 h and PCEA with bupivacaine 0.1% and fentanyl 2 μg/ml epidural solution After 48 hours, a specific satisfaction questionnaire was given to all patients which permitted to obtain 2 different scores concerning postoperative analgesia: a global satisfaction score (0-10) and a detailed satisfaction score (5 questions scored 0-10 with a summative score of 0-50). Both scores, expressed as mean ± SD, were compared between the 4 groups with a Kruskall-Wallis test and between each group with a Mann-Whitney test. A P-value <0.05 was considered significant. Results: Satisfaction scores Gr. 1 (n = 25) Gr. 2 (n = 25) Gr. 3 (n = 25) Gr. 4 (n = 25) P-value global (0-10) 8.2 ± 1.2 9.0 ± 1.0 7.8 ± 2.1 6.5 ± 2.5 0.0006 detailed (0-50) 40 ± 6 43 ± 5 38 ± 6 34 ± 8 0.0002 Conclusion: Satisfaction scores were significantly better in patients who received a systemic postoperative analgesia only (Groups 1 and 2) compared to patients who received systemic and epidural postoperative analgesia (Groups 3 and 4). The best scores were achieved with the combination of intrathecal morphine and multimodal systemic analgesia (Group 2) which allowed early ambulation without significant pain. Patients treated with postoperative epidural analgesia with combined local anesthetics and opioids (Group 4) obtained the worse scores (more restrictive nursing with less mobility, frequent asymmetrical block with insufficient analgesia on one side and motor block on the other)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present strategies for chemical shift assignments of large proteins by magic-angle spinning solid-state NMR, using the 21-kDa disulfide-bond-forming enzyme DsbA as prototype. Previous studies have demonstrated that complete de novo assignments are possible for proteins up to approximately 17 kDa, and partial assignments have been performed for several larger proteins. Here we show that combinations of isotopic labeling strategies, high field correlation spectroscopy, and three-dimensional (3D) and four-dimensional (4D) backbone correlation experiments yield highly confident assignments for more than 90% of backbone resonances in DsbA. Samples were prepared as nanocrystalline precipitates by a dialysis procedure, resulting in heterogeneous linewidths below 0.2 ppm. Thus, high magnetic fields, selective decoupling pulse sequences, and sparse isotopic labeling all improved spectral resolution. Assignments by amino acid type were facilitated by particular combinations of pulse sequences and isotopic labeling; for example, transferred echo double resonance experiments enhanced sensitivity for Pro and Gly residues; [2-(13)C]glycerol labeling clarified Val, Ile, and Leu assignments; in-phase anti-phase correlation spectra enabled interpretation of otherwise crowded Glx/Asx side-chain regions; and 3D NCACX experiments on [2-(13)C]glycerol samples provided unique sets of aromatic (Phe, Tyr, and Trp) correlations. Together with high-sensitivity CANCOCA 4D experiments and CANCOCX 3D experiments, unambiguous backbone walks could be performed throughout the majority of the sequence. At 189 residues, DsbA represents the largest monomeric unit for which essentially complete solid-state NMR assignments have so far been achieved. These results will facilitate studies of nanocrystalline DsbA structure and dynamics and will enable analysis of its 41-kDa covalent complex with the membrane protein DsbB, for which we demonstrate a high-resolution two-dimensional (13)C-(13)C spectrum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Replication Template for Improving Transition Outcomes Council Bluffs Youth Connections E-Mentoring Prototype. This concise document will help your community team implement and plan for sustaining e-mentoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Replication Template for Improving Transition Outcomes Henry County Transition Partners Prototype. This concise document will help you build a community team and the infrastructure necessary to implement and plan for sustaining specific initiatives.