981 resultados para Malmesbury, James Howard Harris, 3d earl of, 1807-1889.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the synthesis of a new class of rod-coil block copolymers, oligosubstituted shape persistent macrocycles, (coil-ring-coil block copolymers), and their behavior in solution and in the solid state.The coil-ring-coil block copolymers are formed by nanometer sized shape persistent macrocycles based on the phenyl-ethynyl backbone as rigid block and oligomers of polystyrene or polydimethylsiloxane as flexible blocks. The strategy that has been followed is to synthesize the macrocycles with an alcoholic functionality and the polymer carboxylic acids independently, and then bind them together by esterification. The ester bond is stable and relatively easy to form.The synthesis of the shape persistent macrocycles is based on two separate steps. In the first step the building blocks of the macrocycles are connected by Hagiara-Sogonaschira coupling to form an 'half-ring' as precursor, that contains two free acetylenes. In the second step the half-ring is cyclized by forming two sp-sp bonds via a copper-catalyzed Glaser coupling under pseudo-high-dilution conditions. The polystyrene carboxylic acid was prepared directly by siphoning the living anionic polymer chain into a THF solution, saturated with CO2, while the polydimethylsiloxane carboxylic acid was obtained by hydrosilylating an unsaturated benzylester with an Si-H terminated polydimethylsiloxane, and cleavage of the ester. The carbodiimide coupling was found to be the best way to connect macrocycles and polymers in high yield and high purity.The polystyrene-ring-polystyrene block copolymers are, depending on the molecular weight of the polystyrene, lyotropic liquid crystals in cyclohexane. The aggregation behavior of the copolymers in solution was investigated in more detail using several technique. As a result it can be concluded that the polystyrene-ring-polystyrene block copolymers can aggregate into hollow cylinder-like objects with an average length of 700 nm by a combination of shape complementary and demixing of rigid and flexible polymer parts. The resulting structure can be described as supramolecular hollow cylindrical brush.If the lyotropic solution of the polystyrene-ring-polystyrene block copolymers are dried, they remain birefringent indicating that the solid state has an ordered structure. The polydimethylsiloxane-ring-polydimethylsiloxane block copolymers are more or less fluid at room temperature, and are all birefringent (termotropic liquid crystals) as well. This is a prove that the copolymers are ordered in the fluid state. By a careful investigation using electron diffraction and wide-angle X-ray scattering, it has been possible to derive a model for the 3D-order of the copolymers. The data indicate a lamella structure for both type of copolymers. The macrocycles are arranged in a layer of columns. These crystalline layers are separated by amorphous layers which contain the polymers substituents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zusammenfassung:Hintergrund/Ziel: Die Beschreibung der funktionellen Einteilung der Leber basiert auf dem Schema von Claude de Couinaud. Die Grenze zwischen der rechten und linken Leberhälfte scheint leicht durch die Lage der mittleren Lebervene lokalisierbar. Nach der gängigen Meinung wird diese Grenze nicht durch die Trias aus Pfortader, Arterie und Gallengang überschritten. Es soll untersucht werden, ob die Lage dieser gefäßarmen Zone zwischen den Pfortaderästen benachbarter Segmente von der Lage der Grenzebene durch die mittlere Lebervene abweicht.Methode: Bei 73 Patienten wurden im Rahmen der normalen präoperativen Diagnostik dreiphasige Spiral-CT Untersuchungen durchgeführt. Aus diesen Daten wurden dreidimensionale Rekonstruktionen erzeugt und ausgewertet. Ergebnisse: In der vorliegenden Untersuchung konnte gezeigt werden, dass die mittlere Sektorengrenze unterschiedliche Positionen einnimmt, je nach welchem Gefäßsystem sie bestimmt wird. Die mittlere Sektorengrenze zeigt hierbei einen Unterschied in ihrer Lage von 14,2° im Median. An der ventralen Leberoberfläche liegt die Grenzebene nach der mittleren Lebervene damit rechts lateral der gefäßarmen Zone zwischen den Pfortaderästen.Schlussfolgerung: Der Unterschied der Grenzebenen ist in dreidimensionalen Rekonstruktionen demonstrierbar und findet Anwendung bei der Segmentzuordnung von Läsionen. Diese Rekonstruktionen erleichtern die interdisziplinäre Kommunikation und erlauben eine vereinfachte und möglicherweise präzisere Operationsplanung.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the experimental methods commonly used to define the behaviour of a full scale system, dynamic tests are the most complete and efficient procedures. A dynamic test is an experimental process, which would define a set of characteristic parameters of the dynamic behaviour of the system, such as natural frequencies of the structure, mode shapes and the corresponding modal damping values associated. An assessment of these modal characteristics can be used both to verify the theoretical assumptions of the project, to monitor the performance of the structural system during its operational use. The thesis is structured in the following chapters: The first introductive chapter recalls some basic notions of dynamics of structure, focusing the discussion on the problem of systems with multiply degrees of freedom (MDOF), which can represent a generic real system under study, when it is excited with harmonic force or in free vibration. The second chapter is entirely centred on to the problem of dynamic identification process of a structure, if it is subjected to an experimental test in forced vibrations. It first describes the construction of FRF through classical FFT of the recorded signal. A different method, also in the frequency domain, is subsequently introduced; it allows accurately to compute the FRF using the geometric characteristics of the ellipse that represents the direct input-output comparison. The two methods are compared and then the attention is focused on some advantages of the proposed methodology. The third chapter focuses on the study of real structures when they are subjected to experimental test, where the force is not known, like in an ambient or impact test. In this analysis we decided to use the CWT, which allows a simultaneous investigation in the time and frequency domain of a generic signal x(t). The CWT is first introduced to process free oscillations, with excellent results both in terms of frequencies, dampings and vibration modes. The application in the case of ambient vibrations defines accurate modal parameters of the system, although on the damping some important observations should be made. The fourth chapter is still on the problem of post processing data acquired after a vibration test, but this time through the application of discrete wavelet transform (DWT). In the first part the results obtained by the DWT are compared with those obtained by the application of CWT. Particular attention is given to the use of DWT as a tool for filtering the recorded signal, in fact in case of ambient vibrations the signals are often affected by the presence of a significant level of noise. The fifth chapter focuses on another important aspect of the identification process: the model updating. In this chapter, starting from the modal parameters obtained from some environmental vibration tests, performed by the University of Porto in 2008 and the University of Sheffild on the Humber Bridge in England, a FE model of the bridge is defined, in order to define what type of model is able to capture more accurately the real dynamic behaviour of the bridge. The sixth chapter outlines the necessary conclusions of the presented research. They concern the application of a method in the frequency domain in order to evaluate the modal parameters of a structure and its advantages, the advantages in applying a procedure based on the use of wavelet transforms in the process of identification in tests with unknown input and finally the problem of 3D modeling of systems with many degrees of freedom and with different types of uncertainty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il lavoro presentato ha come oggetto la ricostruzione tridimensionale della città di Bologna nella sua fase rinascimentale. Tale lavoro vuole fornire un modello 3D delle architetture e degli spazi urbani utilizzabile sia per scopi di ricerca nell’ambito della storia delle città sia per un uso didattico-divulgativo nel settore del turismo culturale. La base del lavoro è una fonte iconografica di grande importanza: l’affresco raffigurante Bologna risalente al 1575 e situato in Vaticano; questa è una veduta a volo d’uccello di grandi dimensioni dell’intero tessuto urbano bolognese all’interno della terza cerchia di mura. In esso sono rappresentate in maniera particolareggiata le architetture civili e ecclesiastiche, gli spazi ortivi e cortilivi interni agli isolati e alcune importanti strutture urbane presenti in città alla fine del Cinquecento, come l’area portuale e i canali interni alla città, oggi non più visibili. La ricostruzione tridimensionale è stata realizzata tramite Blender, software per la modellazione 3D opensource, attraverso le fasi di modellazione, texturing e creazione materiali (mediante campionamento delle principali cromie presenti nell’affresco), illuminazione e animazione. Una parte della modellazione è stata poi testata all’interno di un GIS per verificare l’utilizzo delle geometrie 3D come elementi collegabili ad altre fonti storiche relative allo sviluppo urbano e quindi sfruttabili per la ricerca storica. Grande attenzione infine è stata data all’uso dei modelli virtuali a scopo didattico-divulgativo e per il turismo culturale. La modellazione è stata utilizzata all’interno di un motore grafico 3D per costruire un ambiente virtuale interattivo nel quale un utente anche non esperto possa muoversi per esplorare gli spazi urbani della Bologna del Cinquecento. In ultimo è stato impostato lo sviluppo di un’applicazione per sistemi mobile (Iphone e Ipad) al fine di fornire uno strumento per la conoscenza della città storica in mobilità, attraverso la comparazione dello stato attuale con quello ricostruito virtualmente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arthropodenhämocyanine und Molluskenhämocyanine, die extrazellulären Atmungsproteine der Arthropoden und Mollusken, unterscheiden sich grundsätzlich im Aufbau, besitzen aber ähnliche aktive Zentren, welche in ihrer oxydierten Form für die Blaufärbung der Hämocyanine verantwortlich sind. Sauerstoff wird im Bindungszentrum zwischen zwei, von sechs Histidinen ligandierten, Kupfer(I)Ionen gebunden. Arthropodenhämocyanine bauen sich artspezifisch aus 1, 2, 4, 6, oder 8 Hexameren mit D3-Symmetrie auf. Die Untereinheiten von je ca. 75 kDa falten sich in drei Domänen unterschiedlicher Funktionen. Der komplexe, hierarchische Zusammenbau der Arthropodenhämocyanine hängt von der Heterogenität der Untereinheiten ab. Die 7 verschieden Sequenzen des 4x6-Hämocyanins von Eurypelma californicum (EcHc) sind biochemisch in der Quartärstruktur lokalisiert. Bislang fehlte noch ein unabhängig erstelltes 3D-Modell der geometrischen Gesamtstruktur welche die hexamere und monomere Topographie eindeutig zeigt. Dessen Erstellung war Gegenstand dieser Arbeit, in Verbindung mit der Zielsetzung, die 3D-Rekonstruktion in den beiden extremen physiologischen Zuständen, mit und ohne gebundenen Sauerstoff, zu erzeugen. Dazu wurden in einer eigens entwickelten Atmosphären-Präparationskammer die Proteine in Lösung schockgefrorenen und mittels Cryo-3D-Elektronenmikroskopie gemessen. Aus den daraus gewonnen Projektionsbildern ließen sich mit der ”Single Particle Analyse“ die 3D-Informationen zurückberechnen. Die 3D-Rekonstruktionen wurden mit der publizierten Röntgenkristallstruktur des hexameren Referenz-Hämocyanins der Languste Panulirus interruptus verifiziert. Die Rekonstruktionen erlaubten die eindeutige Messung diverser in der Literatur diskutierter Parameter der Architektur des 4x6-EcHc und darüber hinaus weiterer geometrischer Parameter, welche hier erstmals veröffentlicht werden. SAXS-Daten sagen extreme Translationen und Rotationen von Teilquartärstrukturen zwischen oxy- und deoxy-EcHc voraus, was von den 3D-Rekonstruktionen der beiden Zustände nicht bestätigt werden konnte: Die 16 Å Rekonstruktion der Deoxyform weicht geometrisch nicht von der 21 Å Rekonstruktion der Oxyform ab. Die Einpassung der publizierten Röntgenstruktur der Untereinheit II des Hämocyanin des Pfeilschwanzkrebses Limulus polyphemus in die Rekonstruktionen unterstützt eine auf der hexameren Hierarchieebene lokalisierte Dynamik der Oxygenierung. Mittels Einpassung modellierter molekularer Strukturen der EcHc-Sequenzen konnte eine erste Vermutung zur Lokalisation der beiden zentralen Linker-Untereinheiten b und c des 4x6-Moleküls gemacht werden: Demnach würde Untereinheit b in den exponierten Hexameren des Moleküls liegen. Aussagen über die Quartärstrukturbindungen auf molekularer Ebene aufgrund der Einpassung modellierter molekularer Daten in die Rekonstruktionen sind als spekulativ einzustufen: a) Die Auflösung der Rekonstruktion ist verbesserungswürdig. b) Es gibt keine adäquate Vorlage für eine verlässliche Strukturvorhersage; die verschiedenen EcHc-Sequenzen liegen nur als Modellierung vor. c) Es wäre eine flexible Einpassung notwendig, um Ungenauigkeiten in den modellierten Strukturen durch Sekundärstrukturanpassung zu minimieren.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study concerns the acoustical characterisation of Italian historical theatres. It moved from the ISO 3382 which provides the guidelines for the measurement of a well established set of room acoustic parameters inside performance spaces. Nevertheless, the peculiarity of Italian historical theatres needs a more specific approach. The Charter of Ferrara goes in this direction, aiming at qualifying the sound field in this kind of halls and the present work pursues the way forward. Trying to understand how the acoustical qualification should be done, the Bonci Theatre in Cesena has been taken as a case study. In September 2012 acoustical measurements were carried out in the theatre, recording monaural e binaural impulse responses at each seat in the hall. The values of the time criteria, energy criteria and psycho-acoustical and spatial criteria have been extracted according to ISO 3382. Statistics were performed and a 3D model of the theatre was realised and tuned. Statistical investigations were carried out on the whole set of measurement positions and on carefully chosen reduced subsets; it turned out that these subsets are representative only of the “average” acoustics of the hall. Normality tests were carried out to verify whether EDT, T30 and C80 could be described with some degree of reliability with a theoretical distribution. Different results, according to the varying assumptions underlying each test, were found. Finally, an attempt was made to correlate the numerical results emerged from the statistical analysis to the perceptual sphere. Looking for “acoustical equivalent areas”, relative difference limens were considered as threshold values. No rule of thumb emerged. Finally, the significance of the usual representation through mean values and standard deviation, which may be meaningful for normal distributed data, was investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Staphylococcus aureus is a Gram positive pathogen that causes various human infections and represents one of the most common causes of bacteremia. S. aureus is able to invade a variety of non-professional phagocytes and that can survive engulfment by neutrophils, producing both secreted and surface components that compromise innate immune responses. In the contest of our study we evaluated the functional activity of vaccine specific antibodies by opsonophagocytosis killing assay (OPKA). Interestingly a low level of killing of the staphylococcal cells has been observed. In the meanwhile intracellular survival studies showed that S. aureus persisted inside phagocytes for several hours until a burst of growth after 5 hours in the supernatant. These data suggest that the strong ability of S. aureus to survive in the phagocytes could be the cause of the low killing measured by OPKA. Moreover parallel studies on HL-60 cells infected with S. aureus done by using transmission electron microscopy (TEM) interestingly showed that staphylococcal cells have an intracellular localization (endosomal vacuoles) and that they are able not only to maintain the integrity of their membrane but also to replicate inside vacuolar compartments. Finally in order to generate 3D volume of whole bacteria when present inside neutrophilic vacuoles, we collected a series of tomographic two-dimensional (2D) images by using a transmission electron microscope, generating 5 different tomograms. The three-dimensional reconstruction reveals the presence of intact bacteria within neutrophil vacuoles. The S. aureus membrane appears completely undamaged and integral in contrast with the physiological process of phagosytosis through vacuoles progression. S. aureus bacteria show a homogenous distribution of the density in all the three dimensions (X, Y, Z). All these evidences definitely explain the ability of the pathogen to survive inside the endosomal vacuoles and should be the cause of the low killing level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During my PhD,I have been develop an innovative technique to reproduce in vitro the 3D thymic microenvironment, to be used for growth and differentiation of thymocytes, and possible transplantation replacement in conditions of depressed thymic immune regulation. The work has been developed in the laboratory of Tissue Engineering at the University Hospital in Basel, Switzerland, under the tutorship of Prof.Ivan Martin. Since a number of studies have suggested that the 3D structure of the thymic microenvironment might play a key role in regulating the survival and functional competence of thymocytes, I’ve focused my effort on the isolation and purification of the extracellular matrix of the mouse thymus. Specifically, based on the assumption that TEC can favour the differentiation of pre-T lymphocytes, I’ve developed a specific decellularization protocol to obtain the intact, DNA-free extracellular matrix of the adult mouse thymus. Two different protocols satisfied the main characteristics of a decellularized matrix, according to qualitative and quantitative assays. In particular, the quantity of DNA was less than 10% in absolute value, no positive staining for cells was found and the 3D structure and composition of the ECM were maintained. In addition, I was able to prove that the decellularized matrixes were not cytotoxic for the cells themselves, and were able to increase expression of MHC II antigens compared to control cells grown in standard conditions. I was able to prove that TECs grow and proliferate up to ten days on top the decellularized matrix. After a complete characterization of the culture system, these innovative natural scaffolds could be used to improve the standard culture conditions of TEC, to study in vitro the action of different factors on their differentiation genes, and to test the ability of TECs to induce in vitro maturation of seeded T lymphocytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this thesis was the study of the cement-bone interface in the tibial component of a cemented total knee prosthesis. One of the things you can see in specimens after in vivo service is that resorption of bone occurs in the interdigitated region between bone and cement. A stress shielding effect was investigated as a cause to explain bone resorption. Stress shielding occurs when bone is loaded less than physiological and therefore it starts remodeling according to the new loading conditions. µCT images were used to obtain 3D models of the bone and cement structure and a Finite Element Analysis was used to simulate different kind of loads. Resorption was also simulated by performing erosion operations in the interdigitated bone region. Finally, 4 models were simulated: bone (trabecular), bone with cement, and two models of bone with cement after progressive erosions of the bone. Compression, tension and shear test were simulated for each model in displacement-control until 2% of strain. The results show how the principal strain and Von Mises stress decrease after adding the cement on the structure and after the erosion operations. These results show that a stress shielding effect does occur and rises after resorption starts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wearable inertial and magnetic measurements units (IMMU) are an important tool for underwater motion analysis because they are swimmer-centric, they require only simple measurement set-up and they provide the performance results very quickly. In order to estimate 3D joint kinematics during motion, protocols were developed to transpose the IMMU orientation estimation to a biomechanical model. The aim of the thesis was to validate a protocol originally propositioned to estimate the joint angles of the upper limbs during one-degree-of-freedom movements in dry settings and herein modified to perform 3D kinematics analysis of shoulders, elbows and wrists during swimming. Eight high-level swimmers were assessed in the laboratory by means of an IMMU while simulating the front crawl and breaststroke movements. A stereo-photogrammetric system (SPS) was used as reference. The joint angles (in degrees) of the shoulders (flexion-extension, abduction-adduction and internal-external rotation), the elbows (flexion-extension and pronation-supination), and the wrists (flexion-extension and radial-ulnar deviation) were estimated with the two systems and compared by means of root mean square errors (RMSE), relative RMSE, Pearson’s product-moment coefficient correlation (R) and coefficient of multiple correlation (CMC). Subsequently, the athletes were assessed during pool swimming trials through the IMMU. Considering both swim styles and all joint degrees of freedom modeled, the comparison between the IMMU and the SPS showed median values of RMSE lower than 8°, representing 10% of overall joint range of motion, high median values of CMC (0.97) and R (0.96). These findings suggest that the protocol accurately estimated the 3D orientation of the shoulders, elbows and wrists joint during swimming with accuracy adequate for the purposes of research. In conclusion, the proposed method to evaluate the 3D joint kinematics through IMMU was revealed to be a useful tool for both sport and clinical contexts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrombotic thrombocytopenic purpura (TTP) and hemolytic-uremic syndrome (HUS) represent multiple disorders with diverse etiologies. We compared the gender and race of 335 patients enrolled in the Oklahoma TTP-HUS Registry across 21 years for their first episode of TTP or HUS to appropriate control groups. The relative frequency of women and white race among patients with TTP-HUS-associated with a bloody diarrhea prodrome and the relative frequency of women with quinine-associated TTP-HUS were significantly greater than their control populations. The relative frequency of women and black race among patients with idiopathic TTP and TTP-associated with severe ADAMTS13 deficiency was significantly greater than their control populations. The relative frequency of black race among patients who had systemic lupus erythematosus (SLE) preceding TTP was significantly greater than among a population of patients with SLE, and the relative frequency of black race among patients with other autoimmune disorders preceding TTP was significantly greater than their control population. No significant gender or race disparities were present among patients with hematopoietic stem cell transplantation-associated thrombotic microangiopathy, TTP associated with pregnancy, or TTP associated with drugs other than quinine. The validity of these observations is supported by the enrollment of all consecutive patients across 21 years from a defined geographic region, without selection or referral bias. These observations of different gender and race disparities among the TTP-HUS syndromes suggest the presence of different risk factors and may serve as starting points for novel investigations of pathogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interest in automatic volume meshing for finite element analysis (FEA) has grown more since the appearance of microfocus CT (μCT), due to its high resolution, which allows for the assessment of mechanical behaviour at a high precision. Nevertheless, the basic meshing approach of generating one hexahedron per voxel produces jagged edges. To prevent this effect, smoothing algorithms have been introduced to enhance the topology of the mesh. However, whether smoothing also improves the accuracy of voxel-based meshes in clinical applications is still under question. There is a trade-off between smoothing and quality of elements in the mesh. Distorted elements may be produced by excessive smoothing and reduce accuracy of the mesh. In the present work, influence of smoothing on the accuracy of voxel-based meshes in micro-FE was assessed. An accurate 3D model of a trabecular structure with known apparent mechanical properties was used as a reference model. Virtual CT scans of this reference model (with resolutions of 16, 32 and 64 μm) were then created and used to build voxel-based meshes of the microarchitecture. Effects of smoothing on the apparent mechanical properties of the voxel-based meshes as compared to the reference model were evaluated. Apparent Young’s moduli of the smooth voxel-based mesh were significantly closer to those of the reference model for the 16 and 32 μm resolutions. Improvements were not significant for the 64 μm, due to loss of trabecular connectivity in the model. This study shows that smoothing offers a real benefit to voxel-based meshes used in micro-FE. It might also broaden voxel-based meshing to other biomechanical domains where it was not used previously due to lack of accuracy. As an example, this work will be used in the framework of the European project ContraCancrum, which aims at providing a patient-specific simulation of tumour development in brain and lungs for oncologists. For this type of clinical application, such a fast, automatic, and accurate generation of the mesh is of great benefit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a kernel density correlation based nonrigid point set matching method and shows its application in statistical model based 2D/3D reconstruction of a scaled, patient-specific model from an un-calibrated x-ray radiograph. In this method, both the reference point set and the floating point set are first represented using kernel density estimates. A correlation measure between these two kernel density estimates is then optimized to find a displacement field such that the floating point set is moved to the reference point set. Regularizations based on the overall deformation energy and the motion smoothness energy are used to constraint the displacement field for a robust point set matching. Incorporating this non-rigid point set matching method into a statistical model based 2D/3D reconstruction framework, we can reconstruct a scaled, patient-specific model from noisy edge points that are extracted directly from the x-ray radiograph by an edge detector. Our experiment conducted on datasets of two patients and six cadavers demonstrates a mean reconstruction error of 1.9 mm

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report dramatic sensitivity enhancements in multidimensional MAS NMR spectra by the use of nonuniform sampling (NUS) and introduce maximum entropy interpolation (MINT) processing that assures the linearity between the time and frequency domains of the NUS acquired data sets. A systematic analysis of sensitivity and resolution in 2D and 3D NUS spectra reveals that with NUS, at least 1.5- to 2-fold sensitivity enhancement can be attained in each indirect dimension without compromising the spectral resolution. These enhancements are similar to or higher than those attained by the newest-generation commercial cryogenic probes. We explore the benefits of this NUS/MaxEnt approach in proteins and protein assemblies using 1-73-(U-C-13,N-15)/74-108-(U-N-15) Escherichia coil thioredoxin reassembly. We demonstrate that in thioredoxin reassembly, NUS permits acquisition of high-quality 3D-NCACX spectra, which are inaccessible with conventional sampling due to prohibitively long experiment times. Of critical importance, issues that hinder NUS-based SNR enhancement in 3D-NMR of liquids are mitigated in the study of solid samples in which theoretical enhancements on the order of 3-4 fold are accessible by compounding the NUS-based SNR enhancement of each indirect dimension. NUS/MINT is anticipated to be widely applicable and advantageous for multidimensional heteronuclear MAS NMR spectroscopy of proteins, protein assemblies, and other biological systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of positioning and geometry of ventricular cannulas for contemporary continuous flow Left Ventricular Assist Devices (LVADs) was evaluated in a non-beating isolated heart preparation with borescopic visualization. Preload and LVAD flow were varied to evaluate degrees of ventricular decompression up to the point of ventricular collapse. The performance of a flanged cannula was compared to a conventional bevel-tipped cannula: quantitatively by the maximal flow attainable, and qualitatively by visualization of fluid tracer particles within the ventricular chamber. Three forms of ventricular suck-down occurred: concentric collapse, gradual entrainment and instantaneous entrainment. In some circumstances, unstable oscillations of the ventricle were observed prior to complete collapse. Under conditions of low preload, the flanged cannula demonstrated less positional sensitivity, provided greater flow, and exhibited fewer areas of stagnation than the beveled cannula. These observations warrant further consideration of a flanged ventricular cannula to mitigate complications encountered with conventional cannulae.