941 resultados para METAL-ION IMPLANTATION
Resumo:
Este proyecto tiene como objetivo el estudio de la relación que el bombardino tiene con las formaciones más importantes de viento metal. Para ello he creído necesario, antes de profundizar en este tema, dar a conocer su historia y evolución. Mi intención con este proyecto es contribuir al enriquecimiento del patrimonio de este maravilloso instrumento, que poco a poco, va ganando el respeto que se merece.
Resumo:
El presente estudio expone los resultados del tema desarrollado en la línea investigativa de culturas urbanas contemporáneas y procesos comunicacionales. Trabajo que describe (construye) el arquetipo del aficionado al heavy metal en España.
Resumo:
Following the introduction of single-metal deposition (SMD), a simplified fingermark detection technique based on multimetal deposition, optimization studies were conducted. The different parameters of the original formula were tested and the results were evaluated based on the contrast and overall aspect of the enhanced fingermarks. The new formula for SMD was found based on the most optimized parameters. Interestingly, it was found that important variations from the base parameters did not significantly affect the outcome of the enhancement, thus demonstrating that SMD is a very robust technique. Finally, a comparison of the optimized SMD with multi-metal deposition (MMD) was carried out on different surfaces. It was demonstrated that SMD produces comparable results to MMD, thus validating the technique.
Resumo:
Since 1998 the highly polluted Havana Bay ecosystem has been the subject of a mitigation program. In order to determine whether pollution-reduction strategies were effective, we have evaluated the historical trends of pollution recorded in sediments of the Bay. A sediment core was dated radiometrically using natural and artificial fallout radionuclides. An irregularity in the (210)Pb record was caused by an episode of accelerated sedimentation. This episode was dated to occur in 1982, a year coincident with the heaviest rains reported in Havana over the XX century. Peaks of mass accumulation rates (MAR) were associated with hurricanes and intensive rains. In the past 60 years, these maxima are related to strong El Niño periods, which are known to increase rainfall in the north Caribbean region. We observed a steady increase of pollution (mainly Pb, Zn, Sn, and Hg) since the beginning of the century to the mid 90s, with enrichment factors as high as 6. MAR and pollution decreased rapidly after the mid 90s, although some trace metal levels remain high. This reduction was due to the integrated coastal zone management program introduced in the late 90s, which dismissed catchment erosion and pollution.
Transcatheter aortic valve implantation (TAVI): state of the art techniques and future perspectives.
Resumo:
Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.
Resumo:
Purpose: Aqueous shunt implantation into the anterior chamber is associated with corneal decompensation in up to a third of eyes. Intracameral tube position may affect corneal endothelial cell loss. The authors set out to examine the efficacy and safety of Baerveldt shunt implantation into the ciliary sulcus combined with surgical peripheral iridectomy (SPI). Methods: One hundred eyes prospectively underwent Baerveldt shunt implantation into the cilliary sulcus combined with SPI, leaving a short intracameral tube length (1-2mm). Pre and post operative measures recorded included patient demographics, visual acuity, IOP, number of glaucoma medications (GMs) and all complications. Pre-existing corneal decompensation was recorded. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline with or without GMs. Results: Mean age was 65.4 years (±20.4years). Mean follow-up was 10.8 months. Preoperatively IOP was 25.7mmHg (± 9.9mmHg), GMs were 2.9 (±1.2) and VA was 0.4 (±0.3). At one year postoperatively there was a significant drop in IOP (mean= 13.3mmHg (± 5.0mmHg); p<0.001) and number of GMs (mean= 1.3 (±1.4); p<0.001); and no significant change in VA (mean= 0.4 (±0.3); p=0.93). The success rate at one year was 83%. Complications were minor and non sight threatening (10%), there were no cases of postoperative corneal decompensation, tube blockage or iris/corneal-tube contact. Conclusions: The results demonstrate that placement of Baerveldt shunts into the ciliary sulcus with SPI is a safe and efficacious method of IOP reduction in comparison with standard shunt positioning in the anterior chamber. The intracameral tube position combined with SPI avoided tube-iris contact and corneal decompensation. Sulcus placement of aqueous shunts should be considered in pseudophakic eyes.
Urgent reoperative transapical valve-in-valve shortly after a transapical aortic valve implantation.
Resumo:
Urgent reoperative transapical aortic valve-in-valve has never been proposed as a treatment option in case of a failed transcatheter aortic valve implantation (TAVI) or in case of worsening of an existing paravalvular leak, if this complication occurs right after, or a few days after, the primary transapical aortic valve implantation. Experienced surgeons should argue that after a transapical TAVI, the apex is damaged and fragile, with a high risk of irreparable ventricular tears and life-threatening bleeding if a second transapical procedure is scheduled during the acute phase. Nevertheless, if the patient is inoperable and the vascular status, including the ascending aorta, limits alternative accesses, the urgent reoperative transapical valve-in-valve becomes an alternative. We illustrate, for the first time ever, our experience with an 81-year old female patient who underwent a transapical (TA) TAVI with a Sapien? XT 23 mm. The day after the procedure, the patient haemodynamically worsened in combination with a worsening of a known (grade 1-2) paravalvular leak. Thus, on postoperative day two, an urgent transapical valve-in-valve was performed, and a second Sapien? XT 23 mm was placed, with an excellent haemodynamic result and absence of leak. The redo apical access did not appear very complicated and the postoperative recovery was uneventful.
Resumo:
The annual meeting of the French Ion Channels Society, held on the Mediterranean coast of France, is aimed at gathering the international scientific community working on various aspects of ion channels. In this report of the 19th edition of the meeting, held in September 2008, we summarize selected symposia on aspects of the ion channel field from fundamental to clinical research. The meeting is an opportunity for leading investigators as well as young researchers to present and discuss their recent advances and future challenges in the ion channel field.