980 resultados para Isometric knee extension torque


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the first record of Odontophrynus carvalhoi for the state of Alagoas, Brazil, and a distribution map for this species. This new record represents the nearest location to the Brazilian coast known for this species. © 2010 Check List and Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The geographic distribution of Leptodactylus furnarius Sazima and Bokermann, 1978 comprises Argentina, Brazil (southern, southeastern, and west-central regions), Paraguay, and Uruguay. Herein, we report for the first time the occurrence of L. furnarius in northeastern and north regions of Brazil, at the states of Bahia and Tocantins, respectively. © 2010 Check List and Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein I present a new geographical record of Ischnocnema verrucosa Reinhardt and Lütken, 1862 for northeastern Brazil and briefly discuss the new record with a previous record of similar characteristics. © 2010 Check List and Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypsiboas raniceps is a large treefrog typically found in the Cerrado and Caatinga biomes. Here we provide information about new records of this species in the Atlantic Forest and raise some hypotheses that could explain the late record of this species in this biome. © 2010 Check List and Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study reports new records of the Dipsadid snake Rhachidelus brazili Boulenger, 1908, from Mato Grosso and Mato Grosso do Sul states, Brazil. Our data extend the known geographical distribution ca. 713 km to the northwest and constitute the first record in the Upper Paraguay sub-basin. © 2011 Check List and Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erythroxylaceae have tropical and subtropical distribution with four genera and about 250 species. Erythroxylum is the biggest genus of the family with approximately 100 species cited for Brazil. Erythroxylum subsessile (Mart.) O.E. Schulz is a species cited just for Rio de Janeiro state and now first recorded for the state of Espírito Santo, increasing its area of distribution. © 2012 Check List and Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the nervous activation, muscle strength, and biomechanical parameters that influence the cost of walking in older fallers and non-fallers. Methods: Maximal voluntary isokinetic torque was measured for the hip, knee and ankle of older women. Oxygen consumption was measured at rest and during 8 min of walking at self-selected speed. An additional minute of walking was performed to collect kinematic variables and the electromyographic signal of trunk, hip, knee, and ankle muscles, which was analyzed by the linear envelope. Cost of walking was calculated by subtracting resting body mass-normalized oxygen consumption from walking body mass-normalized oxygen consumption. Stride time and length, and ankle and hip range of motion were calculated from kinematic data. Findings: Older adult fallers had 28% lower knee extensor strength (p = 0.02), 47% lower internal oblique activation at heel contact (p = 0.03), and higher coactivation between tibialis anterior and gastrocnemius lateralis in each of the gait phases (p < 0.05). For fallers, a higher activation of gluteus maximus was associated with a higher cost of walking (r = 0.55, p < 0.05 and r = 0.71, p < 0.01, before and after heel contact, respectively). For non-fallers, an association between cost of walking and age (r = 0.60, p = 0.01) and cost of walking and thigh muscle coactivation (r = 0.53, p = 0.01) existed. Interpretation: This study demonstrated that there may be links between lower-extremity muscle weakness, muscle activation patterns, altered gait, and increased cost of walking in older fallers. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to evaluate mechanical behavior of implants inserted in three substrates, by measuring the pullout strength and the relative stiffness. 32 implants (Master Porous-Conexao, cylindrical, external hexagon, and surface treatment) were divided into 4 groups (n = 8): pig rib bone, polyurethane Synbone, polyurethane Nacional 40 PCF, and pinus wood. Implants were installed with the exact distance of 5 mm of another implant. The insertion torque (N·cm) was quantified using the digital Kratos torque meter and the pullout test (N) was performed by an axial traction force toward the long axis of the implant (2 min/mm) through mount implant devices attached to a piece adapted to a load cell of 200 Kg of a universal testing machine (Emic DL10000). Data of insertion torque and maximum pullout force were submitted to one-way ANOVA and Bonferroni tests (α = 0.05). Polyurethane Nacional 40 PCF and pinus wood showed the highest values of insertion torque and pullout force, with significant statistical difference (P < 0.05) with other groups. The analysis showed stiffness materials with the highest values for primary stability. © 2013 Nathalia Ferraz Oliscovicz et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The relationship between normal and tangential force components (grip force - GF and load force - LF, respectively) acting on the digits-object interface during object manipulation reveals neural mechanisms involved in movement control. Here, we examined whether the feedback type provided to the participants during exertion of LF would influence GF-LF coordination and task performance. Methods. Sixteen young (24.7 ±3.8 years-old) volunteers isometrically exerted continuously sinusoidal FZ (vertical component of LF) by pulling a fixed instrumented handle up and relaxing under two feedback conditions: targeting and tracking. In targeting condition, FZ exertion range was determined by horizontal lines representing the upper (10 N) and lower (1 N) targets, with frequency (0.77 or 1.53 Hz) dictated by a metronome. In tracking condition, a sinusoidal template set at similar frequencies and range was presented and should be superposed by the participants' exerted FZ. Task performance was assessed by absolute errors at peaks (AEPeak) and valleys (AEValley) and GF-LF coordination by GF-LF ratios, maximum cross-correlation coefficients (r max), and time lags. Results: The results revealed no effect of feedback and no feedback by frequency interaction on any variable. AE Peak and GF-LF ratio were higher and rmax lower at 1.53 Hz than at 0.77 Hz. Conclusion: These findings indicate that the type of feedback does not influence task performance and GF-LF coordination. Therefore, we recommend the use of tracking tasks when assessing GF-LF coordination during isometric LF exertion in externally fixed instrumented handles because they are easier to understand and provide additional indices (e.g., RMSE) of voluntary force control. © 2013 Pedão et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Age-related loss in lower limb strength is related with impaired mobility. However, the association between decreased lower limb strength and gait biomechanical abnormalities is unclear. %In line with this, With respect to these statements, our study aimed to compare the maximum isokinetic voluntary strength (MIVS) of hip, knee and ankle of older women with and without history of falls. Also, we correlate the strength of each group with gait biomechanics. METHODS: The MIVS were assessed during concentric/concentric movements performed for hip, knee and ankle joints. Gait biomechanics (kinematic and electromyography) were assessed during 1-minute recorded during the volunteers walking on the treadmill at self-selected speed. Electromyographic signal was analyzed by the linear envelop after heel strike and before toe-off. The kinematic data were analyzed using the variables: step time, length and step width and ankle angle at heel strike, and hip angle at toe-off. RESULTS: In faller group, we found that a decreased hip abduction and adduction MIVS is associated with a higher tibialis anterior activation at initial stance (p =0.04 and r =-0.53 and p=0.04 and r=-0.52). CONCLUSION: Therefore, an impaired strength of hip could causes compensation in ankle stabilizer muscles activation at initial stance in older female fallers. © 2013 - IOS Press and the authors. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate bone healing around dental implants with established osseointegration in experimental diabetes mellitus (DM) and insulin therapy by histomorphometric and removal torque analysis in a rat model. Materials and methods: A total of 80 male Wistar rats received a titanium implant in the tibiae proximal methaphysis. After a healing period of 60 days, the rats were divided into four groups of 20 animals each: a 2-month control group, sacrificed at time (group A), a diabetic group (group D), an insulin group (group I), and a 4-month control group (group C), subdivided half for removal torque and half for histomorphometric analysis. In the D and I groups the DM was induced by a single injection of 40 mg/kg body weight streptozotocin (STZ). Two days after DM induction, group I received subcutaneous doses of insulin twice a day, during 2 months. Groups C and D received only saline. Two months after induction of DM, the animals of groups D, C and I were sacrificed. The plasmatic levels of glucose (GPL) were monitored throughout the experiment. Evaluation of the percentages of bone-to-implant contact and bone area within the limits of the implant threads was done by histomorphometric and mechanical torque analysis. Data were analyzed by anova at significant level of 5%. Results: The GPL were within normal range for groups A, C and I and higher for group D. The means and standard deviations (SD) for histomorphometric bone area showed significant difference between group D (69.34 ± 5.00%) and groups C (78.20 ± 4.88%) and I (79.63 ± 4.97%). Related to bone-to-implant contact there were no significant difference between the groups D (60.81 + 6.83%), C (63.37 + 5.88%) and I (66.97 + 4.13%). The means and SD for removal torque showed that group D (12.91 ± 2.51 Ncm) was statistically lower than group I (17.10 ± 3.06 Ncm) and C (16.95 ± 5.39 Ncm). Conclusions: Diabetes mellitus impaired the bone healing around dental implants with established osseointegration because the results presented a lower percentage of bone area in group D in relation to groups C and I resulting in a lowest torque values for implant removal. Moreover, insulin therapy prevents the occurrence of bone abnormalities found in diabetic animals and osseointegration was not compromised. © 2012 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)