980 resultados para Intensity modulated radiotherapy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flattening filter free (FFF) linear accelerators allow for an increase in instantaneous dose-rate of the x-ray pulses by a factor of 2-6 over the conventional flattened output. As a result, radiobiological investigations are being carried out to determine the effect of these higher dose-rates on cell response. The studies reported thus far have presented conflicting results, highlighting the need for further investigation. To determine the radiobiological impact of the increased dose-rates from FFF exposures a Varian Truebeam medical linear accelerator was used to irradiate two human cancer cell lines in vitro, DU-145 prostate and H460 non-small cell lung, with both flattened and FFF 6 MV beams. The fluence profile of the FFF beam was modified using a custom-designed Nylon compensator to produce a similar dose profile to the flattened beam (6X) at the cell surface but at a higher instantaneous dose-rate. For both cell lines there appeared to be no significant change in cell survival. Curve fitting coefficients for DU145 cells irradiated with constant average dose-rates were 6X: alpha = 0.09 +/- 0.03, beta = 0.03 +/- 0.01 and 6FFF: alpha = 0.14 +/- 0.13, beta = 0.03 +/- 0.02 with a significance of p = 0.75. For H460 cells irradiated with the same instantaneous dose-rate but different average dose-rate the fit coefficients were 6FFF (low dose-rate): alpha = 0.21 +/- 0.11, 0.07 +/- 0.02 and 6FFF (high dose-rate): alpha = 0.21 +/- 0.16, 0.07 +/- 0.03, with p = 0.79. The results indicate that collective damage behaviour does not occur at the instantaneous dose-rates investigated here and that the use of either modality should result in the same clinical outcome, however this will require further validation in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free space transmission of an on-off modulated sinusoidal signal through a phase conjugating lens (PCL) is theoretically examined using a combined time/frequency domain approach. The on-off keyed (OOK) signal is generated by a dipole antenna located in the far-field zone of the lens. The PCL consists of a dual layer of antenna elements interconnected via phase conjugating circuitry. We demonstrate that electromagnetic interference between antenna elements creates spatially localised areas of good-quality reception and zones where the signal is significantly denigrated by interference. Next, it is shown that destructive interference and packet desynchronisation effects critically depend on bit rate. It is also shown that a circular concave lens can be used to produce high-quality signal reception in a given direction while suppressing signal reception in all other directions. The effect that the bandwidth of the phase conjugating unit has on the transmitted signal properties for the cases of high and low bit rate OOK modulation are studied and a signal quality characterisation scheme is proposed which uses cross-correlation. The results of the study yields understanding of the performance of phase conjugating arrays under OOK modulation. The work suggests a novel approach for realising a secure communication wireless system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is estimated that 60% of patients diagnosed with head and neck cancer will receive radiotherapy at some stage in their disease trajectory. The aim of this literature review was to find and analyse papers pertaining to the lived experiences of patients with head and neck cancer receiving radiotherapy. The review identified a limited number of high-quality research papers focusing on this topic, with only 10 papers fitting the inclusion/exclusion criteria. The majority of the investigative studies were not generalisable owing to small sample sizes and many of them being conducted in only one centre. However, the findings do highlight and contribute to the understanding of the lived experiences of this patient group and provide some insight into the unique physical, social, and psychological difficulties they encounter as a result of their treatment. There appears to be a need for further high-level research into these patients, particularly focusing on the provision of support and information prior to, during, and following radiotherapy. Further attention needs to be paid to preparing patients for the slow recovery following radiotherapy. Interventional studies are also required to develop clinical guidelines and protocols that can assist health professionals in meeting the holistic needs of this patient group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurements reported here provide scaling laws for the ion acceleration process in the regime of ultrashort (50 fs), ultrahigh contrast (10) and ultrahigh intensity (> 10W/cm ), never investigated previously. The scaling of the accelerated ion energies was studied by varying a number of parameters such as target thickness (down to 10nm), target material (C and Al) and laser light polar- ization (circular and linear) at 35° and normal laser incidence. A twofold increase in proton energy and an order of magnitude enhancement in ion flux have been observed over the investigated thickness range at 35° angle of incidence. Further- more, at normal laser incidence, measured peak proton energies of about 20 MeV are observed almost independently of the target thickness over a wide range (50nm- 10 µm). 1. © 2012 by Società Italiana di Fisica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biological dose escalation through stereotactic ablative radiotherapy (SABR) holds promise of improved patient convenience, system capacity and tumor control with decreased cost and side effects. The objectives are to report the toxicities, biochemical and pathologic outcomes of this prospective study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To investigate the potential dosimetric and clinical benefits predicted by using four-dimensional computed tomography (4DCT) compared with 3DCT in the planning of radical radiotherapy for non-small cell lung cancer.

MATERIALS AND METHODS:
Twenty patients were planned using free breathing 4DCT then retrospectively delineated on three-dimensional helical scan sets (3DCT). Beam arrangement and total dose (55 Gy in 20 fractions) were matched for 3D and 4D plans. Plans were compared for differences in planning target volume (PTV) geometrics and normal tissue complication probability (NTCP) for organs at risk using dose volume histograms. Tumour control probability and NTCP were modelled using the Lyman-Kutcher-Burman (LKB) model. This was compared with a predictive clinical algorithm (Maastro), which is based on patient characteristics, including: age, performance status, smoking history, lung function, tumour staging and concomitant chemotherapy, to predict survival and toxicity outcomes. Potential therapeutic gains were investigated by applying isotoxic dose escalation to both plans using constraints for mean lung dose (18 Gy), oesophageal maximum (70 Gy) and spinal cord maximum (48 Gy).

RESULTS:
4DCT based plans had lower PTV volumes, a lower dose to organs at risk and lower predicted NTCP rates on LKB modelling (P < 0.006). The clinical algorithm showed no difference for predicted 2-year survival and dyspnoea rates between the groups, but did predict for lower oesophageal toxicity with 4DCT plans (P = 0.001). There was no correlation between LKB modelling and the clinical algorithm for lung toxicity or survival. Dose escalation was possible in 15/20 cases, with a mean increase in dose by a factor of 1.19 (10.45 Gy) using 4DCT compared with 3DCT plans.

CONCLUSIONS:
4DCT can theoretically improve therapeutic ratio and dose escalation based on dosimetric parameters and mathematical modelling. However, when individual characteristics are incorporated, this gain may be less evident in terms of survival and dyspnoea rates. 4DCT allows potential for isotoxic dose escalation, which may lead to improved local control and better overall survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the effect of pre-treatment verification imaging with megavoltage (MV) X-rays on cancer and normal cell survival in vitro and to compare the findings with theoretically modelled data. Since the dose received from pre-treatment imaging can be significant, incorporation of this dose at the planning stage of treatment has been suggested.

Methods: The impact of imaging dose incorporation on cell survival was investigated by clonogenic assay, irradiating DU-145 prostate cancer, H460 non-small cell lung cancer and AGO-1522b normal tissue fibroblast cells. Clinically relevant imaging-to-treatment times of 7.5 minutes and 15 minutes were chosen for this study. The theoretical magnitude of the loss of radiobiological efficacy due to sublethal damage repair was investigated using the Lea-Catcheside dose protraction factor model.

Results: For the cell lines investigated, the experimental data showed that imaging dose incorporation had no significant impact upon cell survival. These findings were in close agreement with the theoretical results.

Conclusions: For the conditions investigated, the results suggest that allowance for the imaging dose at the planning stage of treatment should not adversely affect treatment efficacy.

Advances in Knowledge: There is a paucity of data in the literature on imaging effects in radiotherapy. This paper presents a systematic study of imaging dose effects on cancer and normal cell survival, providing both theoretical and experimental evidence for clinically relevant imaging doses and imaging-to-treatment times. The data provide a firm foundation for further study into this highly relevant area of research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This paper reports a study on how men cope with the side-effects of radiotherapy and neo-adjuvant androgen deprivation for prostate cancer up to 1 year after treatment.

Background: With early detection and improved treatments, prostate cancer survivors are living longer with the disease and the side-effects of treatment. How they cope affects their long-term physical and mental health.

Design: A prospective, longitudinal, exploratory design using both qualitative and quantitative methods was used in this study.

Method: Between September 2006–September 2007 149 men who were about to undergo radical radiotherapy ± androgen deprivation for localized prostate cancer in Northern Ireland were recruited to the study. They completed the Brief Cope scale at four time-points.

Results: Acceptance, positive reframing, emotional support, planning and, just getting on with it, were the most common ways of coping. Fewer men used coping strategies less at 6 months and 1 year after radiotherapy in comparison to pre-treatment and 4–6 weeks after radiotherapy. Interviews with these men demonstrated that men adapted to a new norm, with the support of their wives/partners and did not readily seek professional help. A minority of men used alcohol, behavioural disengagement and self blame as ways of coping.

Conclusion: Men used a variety of ways of coping to help them deal with radiotherapy and neo-adjuvant androgen deprivation for up to 12 months after radiotherapy. Interventions need to be developed to take account of the specific needs of partners of men with prostate cancer and single men who have prostate cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posterior parietal cortex (PPC) constitutes a critical cortical node in the sensorimotor system in which goal-directed actions are computed. This information then must be transferred into commands suitable for hand movements to the primary motor cortex (M1). Complexity arises because reach-to-grasp actions not only require directing the hand towards the object (transport component), but also preshaping the hand according to the features of the object (grip component). Yet, the functional influence that specific PPC regions exert over ipsilateral M1 during the planning of different hand movements remains unclear in humans. Here we manipulated transport and grip components of goal-directed hand movements and exploited paired-pulse transcranial magnetic stimulation (ppTMS) to probe the functional interactions between M1 and two different PPC regions, namely superior parieto-occipital cortex (SPOC) and the anterior region of the intraparietal sulcus (aIPS), in the left hemisphere. We show that when the extension of the arm is required to contact a target object, SPOC selectively facilitates motor evoked potentials, suggesting that SPOC-M1 interactions are functionally specific to arm transport. In contrast, a different pathway, linking the aIPS and ipsilateral M1, shows enhanced functional connections during the sensorimotor planning of grip. These results support recent human neuroimaging findings arguing for specialized human parietal regions for the planning of arm transport and hand grip during goal-directed actions. Importantly, they provide new insight into the causal influences these different parietal regions exert over ipsilateral motor cortex for specific types of planned hand movements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intrafraction tumour motion is an issue that is of increased interest in the era of image-guided radiotherapy. It is particularly relevant for non-small cell lung cancer, for which a number of recent developments are in use to aid with motion management in the delivery of radical radiotherapy. The ability to deliver hypofractionated ablative doses, such as in stereotactic radiotherapy, has been aided by improvements in the ability to analyse tumour motion and amend treatment delivery. In addition, accounting for tumour motion can enable dose escalation to occur by reducing the normal tissue being irradiated by virtue of a reduction in target volumes. Motion management for lung tumours incorporates five key components: imaging, breath-hold techniques, abdominal compression, respiratory tracking and respiratory gating. These will be described, together with the relevant benefits and associated complexities. Many studies have described improved dosimetric coverage and reduced normal tissue complication probability rates when using motion management techniques. Despite the widespread uptake of many of these techniques, there is a paucity of literature reporting improved outcome in overall survival and local control for patients whenever motion management techniques are used. This overview will review the extent of lung tumour motion, ways in which motion is detected and summarise the key methods used in motion management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:
Advanced radiotherapy techniques permit accurate delivery of radiotherapy to lung tumours. Improved accuracy increases the possibility of radiotherapy field geographic miss of the tumour. One source of error is the accuracy of target volume (TV) delineation by the clinical oncologist. Colleague peer review of all curative intent lung cancer plans has been mandatory in our institution since May 2013. At least 2 clinical oncologists review plans checking treatment paradigm, TV delineated, dose to tumour and dose to critical organs. We report the impact of peer review on the radiotherapy planning process for lung cancer.

Methods:
The radiotherapy treatment plans of all patients receiving radical radiotherapy were presented at weekly peer review meetings after their TVs volumes were provisionally signed off by the treating consultant or post-fellowship registrar. All cases and any resultant change to the treatment plan were recorded in our prospective peer review database. We present the summary of changes agreed following the peer review process for a 6 month period.

Results:
Fifteen peer review sessions, including 46 patients (36 NSCLC, 10 SCLC) were analysed. An average of 3 cases were discussed per meeting (range 1 5). 24% of treatment courses were changed. In 4% there was a complete change in paradigm
of treatment (1 patient proceeded to induction chemotherapy, 1 patient had high dose palliative radiotherapy). In 16% there was a change in TV delineated and in 9% a change in dose (2 dose reductions and 2 alterations to post-operative dose fractionations).

Conclusions:
Consultant led peer review resulted in a change in a component of the treatment plan for 28% of patients that would not otherwise have taken place. Given this impact, consultant led peer review should be considered as an essential component in the radiotherapy planning process for all patients treated with curative radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Features analysis is an important task which can significantly affect the performance of automatic bacteria colony picking. Unstructured environments also affect the automatic colony screening. This paper presents a novel approach for adaptive colony segmentation in unstructured environments by treating the detected peaks of intensity histograms as a morphological feature of images. In order to avoid disturbing peaks, an entropy based mean shift filter is introduced to smooth images as a preprocessing step. The relevance and importance of these features can be determined in an improved support vector machine classifier using unascertained least square estimation. Experimental results show that the proposed unascertained least square support vector machine (ULSSVM) has better recognition accuracy than the other state-of-the-art techniques, and its training process takes less time than most of the traditional approaches presented in this paper.