983 resultados para IMPLANT
Resumo:
Abstract Purpose: To describe viral retinitis following intravitreal and periocular corticosteroid administration. Methods: Retrospective case series and comprehensive literature review. Results: We analyzed 5 unreported and 25 previously published cases of viral retinitis following local corticosteroid administration. Causes of retinitis included 23 CMV (76.7%), 5 HSV (16.7%), and 1 each VZV and unspecified (3.3%). Two of 22 tested patients (9.1%) were HIV positive. Twenty-one of 30 (70.0%) cases followed one or more intravitreal injections of triamcinolone acetonide (TA), 4 (13.3%) after one or more posterior sub-Tenon injections of TA, 3 (10.0%) after placement of a 0.59-mg fluocinolone acetonide implant (Retisert), and 1 (3.3%) each after an anterior subconjunctival injection of TA (together with IVTA), an anterior chamber injection, and an anterior sub-Tenon injection. Mean time from most recent corticosteroid administration to development of retinitis was 4.2 months (median 3.8; range 0.25-13.0). Twelve patients (40.0%) had type II diabetes mellitus. Treatments used included systemic antiviral agents (26/30, 86.7%), intravitreal antiviral injections (20/30, 66.7%), and ganciclovir intravitreal implants (4/30, 13.3%). Conclusions: Viral retinitis may develop or reactivate following intraocular or periocular corticosteroid administration. Average time to development of retinitis was 4 months, and CMV was the most frequently observed agent. Diabetes was a frequent co-morbidity and several patients with uveitis who developed retinitis were also receiving systemic immunosuppressive therapy.
Resumo:
Résumé Les fractures extra capsulaires du fémur proximal sont connues pour le risque élevé de morbidité et de mortalité en cas de traitement non chirurgical. Ainsi, le clou Gamma standard a été produit pour garantir une fixation stable de ces fractures permettant par conséquent une mobilisation rapide et en charge des personnes en âge avancé et présentant ce genre de fracture. Mais il a été reproché à ce type de clou un nombre relativement élevé de fracture per ou post opératoire (environ 17%). Cette complication est liée au design de cet implant. Et, de ce fait, le clou Trochantéric a été créé pour remédier à cette complication en changeant la forme du clou et notamment sa courbure. Entre juillet 2000 et janvier 2001, 88 patients ont été traités par clou Trochantéric pour une fracture pertrochantérienne et suivis consécutivement dans notre Service. 75 patients, soit 76 fractures, ont pu être évalués cliniquement et radiologiquement durant une évolution de deux ans.
Resumo:
Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.
Resumo:
Résumé Les glissements de terrain représentent un des principaux risques naturels dans les régions montagneuses. En Suisse, chaque année les glissements de terrains causent des dégâts qui affectent les infrastructures et ont des coûts financiers importants. Une bonne compréhension des mécanismes des glissements peut permettre d'atténuer leur impact. Celle-ci passe notamment par la connaissance de la structure interne du glissement, la détermination de son volume et de son ou ses plans de glissement. Dans un glissement de terrain, la désorganisation et la présence de fractures dans le matériel déplacé engendre un changement des paramètres physiques et en particulier une diminution des vitesses de propagation des ondes sismiques ainsi que de la densité du matériel. Les méthodes sismiques sont de ce fait bien adaptées à l'étude des glissements de terrain. Parmi les méthodes sismiques, l'analyse de la dispersion des ondes de surface est une méthode simple à mettre en oeuvre. Elle présente l'avantage d'estimer les variations des vitesses de cisaillement avec la profondeur sans avoir spécifiquement recours à l'utilisation d'une source d'onde S et de géophones horizontaux. Sa mise en oeuvre en trois étapes implique la mesure de la dispersion des ondes de surface sur des réseaux étendus, la détermination des courbes de dispersion pour finir par l'inversion de ces courbes. Les modèles de vitesse obtenus à partir de cette procédure ne sont valides que lorsque les milieux explorés ne présentent pas de variations latérales. En pratique cette hypothèse est rarement vérifiée, notamment pour un glissement de terrain dans lequel les couches remaniées sont susceptibles de présenter de fortes hétérogénéités latérales. Pour évaluer la possibilité de déterminer des courbes de dispersion à partir de réseaux de faible extension des mesures testes ont été effectuées sur un site (Arnex, VD) équipé d'un forage. Un profil sismique de 190 m de long a été implanté dans une vallée creusée dans du calcaire et remplie par des dépôts glacio-lacustres d'une trentaine de mètres d'épaisseur. Les données acquises le long de ce profil ont confirmé que la présence de variations latérales sous le réseau de géophones affecte l'allure des courbes de dispersion jusqu'à parfois empêcher leur détermination. Pour utiliser l'analyse de la dispersion des ondes de surface sur des sites présentant des variations latérales, notre approche consiste à déterminer les courbes de dispersions pour une série de réseaux de faible extension, à inverser chacune des courbes et à interpoler les différents modèles de vitesse obtenus. Le choix de la position ainsi que de l'extension des différents réseaux de géophones est important. Il tient compte de la localisation des hétérogénéités détectées à partir de l'analyse de sismique réfraction, mais également d'anomalies d'amplitudes observées sur des cartes qui représentent dans le domaine position de tir - position du récepteur, l'amplitude mesurée pour différentes fréquences. La procédure proposée par Lin et Lin (2007) s'est avérée être une méthode efficace permettant de déterminer des courbes de dispersion à partir de réseaux de faible extension. Elle consiste à construire à partir d'un réseau de géophones et de plusieurs positions de tir un enregistrement temps-déports qui tient compte d'une large gamme de distances source-récepteur. Au moment d'assembler les différentes données une correction de phase est appliquée pour tenir compte des hétérogénéités situées entre les différents points de tir. Pour évaluer cette correction nous suggérons de calculer pour deux tir successif la densité spectrale croisée des traces de même offset: Sur le site d'Arnex, 22 courbes de dispersions ont été déterminées pour de réseaux de géophones de 10 m d'extension. Nous avons également profité du forage pour acquérir un profil de sismique verticale en ondes S. Le modèle de vitesse S déduit de l'interprétation du profil de sismique verticale est utilisé comme information à priori lors l'inversion des différentes courbes de dispersion. Finalement, le modèle en deux dimension qui a été établi grâce à l'analyse de la dispersion des ondes de surface met en évidence une structure tabulaire à trois couches dont les limites coïncident bien avec les limites lithologiques observées dans le forage. Dans celui-ci des argiles limoneuses associées à une vitesse de propagation des ondes S de l'ordre de 175 m/s surmontent vers 9 m de profondeur des dépôts de moraine argilo-sableuse caractérisés par des vitesses de propagation des ondes S de l'ordre de 300 m/s jusqu'à 14 m de profondeur et supérieur ou égal à 400 m/s entre 14 et 20 m de profondeur. Le glissement de la Grande Combe (Ballaigues, VD) se produit à l'intérieur du remplissage quaternaire d'une combe creusée dans des calcaires Portlandien. Comme dans le cas du site d'Arnex les dépôts quaternaires correspondent à des dépôts glacio-lacustres. Dans la partie supérieure la surface de glissement a été localisée à une vingtaine de mètres de profondeur au niveau de l'interface qui sépare des dépôts de moraine jurassienne et des dépôts glacio-lacustres. Au pied du glissement 14 courbes de dispersions ont été déterminées sur des réseaux de 10 m d'extension le long d'un profil de 144 m. Les courbes obtenues sont discontinues et définies pour un domaine de fréquence de 7 à 35 Hz. Grâce à l'utilisation de distances source-récepteur entre 8 et 72 m, 2 à 4 modes de propagation ont été identifiés pour chacune des courbes. Lors de l'inversion des courbes de dispersion la prise en compte des différents modes de propagation a permis d'étendre la profondeur d'investigation jusqu'à une vingtaine de mètres de profondeur. Le modèle en deux dimensions permet de distinguer 4 couches (Vs1 < 175 m/s, 175 m/s < Vs2 < 225 m/s, 225 m/s < Vs3 < 400 m/s et Vs4 >.400 m/s) qui présentent des variations d'épaisseur. Des profils de sismiques réflexion en ondes S acquis avec une source construite dans le cadre de ce travail, complètent et corroborent le modèle établi à partir de l'analyse de la dispersion des ondes de surface. Un réflecteur localisé entre 5 et 10 m de profondeur et associé à une vitesse de sommation de 180 m/s souligne notamment la géométrie de l'interface qui sépare la deuxième de la troisième couche du modèle établi à partir de l'analyse de la dispersion des ondes de surface. Abstract Landslides are one of the main natural hazards in mountainous regions. In Switzerland, landslides cause damages every year that impact infrastructures and have important financial costs. In depth understanding of sliding mechanisms may help limiting their impact. In particular, this can be achieved through a better knowledge of the internal structure of the landslide, the determination of its volume and its sliding surface or surfaces In a landslide, the disorganization and the presence of fractures in the displaced material generate a change of the physical parameters and in particular a decrease of the seismic velocities and of the material density. Therefoe, seismic methods are well adapted to the study of landslides. Among seismic methods, surface-wave dispersion analysis is a easy to implement. Through it, shearwave velocity variations with depth can be estimated without having to resort to an S-wave source and to horizontal geophones. Its 3-step implementation implies measurement of surface-wave dispersion with long arrays, determination of the dispersion curves and finally inversion of these curves. Velocity models obtained through this approach are only valid when the investigated medium does not include lateral variations. In practice, this assumption is seldom correct, in particular for landslides in which reshaped layers likely include strong lateral heterogeneities. To assess the possibility of determining dispersion curves from short array lengths we carried out tests measurements on a site (Arnex, VD) that includes a borehole. A 190 m long seismic profile was acquired in a valley carved into limestone and filled with 30 m of glacio-lacustrine sediments. The data acquired along this profile confirmed that the presence of lateral variations under the geophone array influences the dispersion-curve shape so much that it sometimes preventes the dispersion curves determination. Our approach to use the analysis of surface-wave dispersion on sites that include lateral variations consists in obtaining dispersion curves for a series of short length arrays; inverting each so obtained curve and interpolating the different obtained velocity model. The choice of the location as well as the geophone array length is important. It takes into account the location of the heterogeneities that are revealed by the seismic refraction interpretation of the data but also, the location of signal amplitude anomalies observed on maps that represent, for a given frequency, the measured amplitude in the shot position - receiver position domain. The procedure proposed by Lin and Lin (2007) turned out to be an efficient one to determine dispersion curves using short extension arrays. It consists in building a time-offset from an array of geophones with a wide offset range by gathering seismograms acquired with different source-to-receiver offsets. When assembling the different data, a phase correction is applied in order to reduce static phase error induced by lateral variation. To evaluate this correction, we suggest to calculate, for two successive shots, the cross power spectral density of common offset traces. On the Arnex site, 22 curves were determined with 10m in length geophone-arrays. We also took advantage of the borehole to acquire a S-wave vertical seismic profile. The S-wave velocity depth model derived from the vertical seismic profile interpretation is used as prior information in the inversion of the dispersion-curves. Finally a 2D velocity model was established from the analysis of the different dispersion curves. It reveals a 3-layer structure in good agreement with the observed lithologies in the borehole. In it a clay layer with a shear-wave of 175 m/s shear-wave velocity overlies a clayey-sandy till layer at 9 m depth that is characterized down to 14 m by a 300 m/s S-wave velocity; these deposits have a S-wave velocity of 400 m/s between depths of 14 to 20 m. The La Grand Combe landslide (Ballaigues, VD) occurs inside the Quaternary filling of a valley carved into Portlandien limestone. As at the Arnex site, the Quaternary deposits correspond to glaciolacustrine sediments. In the upper part of the landslide, the sliding surface is located at a depth of about 20 m that coincides with the discontinuity between Jurassian till and glacio-lacustrine deposits. At the toe of the landslide, we defined 14 dispersion curves along a 144 m long profile using 10 m long geophone arrays. The obtained curves are discontinuous and defined within a frequency range of 7 to 35 Hz. The use of a wide range of offsets (from 8 to 72 m) enabled us to determine 2 to 4 mode of propagation for each dispersion curve. Taking these higher modes into consideration for dispersion curve inversion allowed us to reach an investigation depth of about 20 m. A four layer 2D model was derived (Vs1< 175 m/s, 175 m/s <Vs2< 225 m/s, 225 m/s < Vs3 < 400 m/s, Vs4> 400 m/s) with variable layer thicknesses. S-wave seismic reflection profiles acquired with a source built as part of this work complete and the velocity model revealed by surface-wave analysis. In particular, reflector at a depth of 5 to 10 m associated with a 180 m/s stacking velocity image the geometry of the discontinuity between the second and third layer of the model derived from the surface-wave dispersion analysis.
Resumo:
Background: Negative pressure wound treatment is increasingly used through a Vacuum-Assisted Closure (VAC) device in complex wound situations. For this purpose, sterile polyurethane (PU) and polyvinyl alcohol (PVA) foam dressings are fitted to the wound size and covered with an adhesive drape to create an airtight seal. Little information exists about the type and quantity of microorganisms within the foams. Therefore, we investigated VAC foams after removal from the wound using a validated method (sonication) to detect the bacterial bioburden in the foam consisting as microbial biofilms.Methods: We prospectively included VAC foams (PU and PVA, KCI, Rümlamg, Switzerland) without antibacterial additions (e.g. silver), which were removed from wounds in patients with chronic ulcers from January 2007 through December 2008. Excluded were patients with acute wound infection, necrotizing fasciitis, underlying osteomyelitis or implant. Removed foams from regular changes of dressing were aseptically placed in a container with 100 ml sterile Ringer's solution. Within 4 hours after removal, foams were sonicated for 5 min at 40 kHz (as described in NEJM 2007;357:654). The resulting sonication fluid was cultured at 37°C on aerobic blood agar plates for 5 days. Microbes were quantified as No. of colony-forming units (CFU)/ml sonication fluid and identified to the species level.Results: A total of 68 foams (38 PU and 30 PVA) from 55 patients were included in the study (median age 71 years; range 33-88 years, 57% were man). Foams were removed from the following anatomic sites: sacrum (n=29), ischium (n=18), heel (n=13), calves (n=6) and ankle (n=2). The median duration of being in place was 3 days (range, 1-8 days). In all 68 foams, bacteria were found in large quantities (median 105 CFU/ml, range 102-7 CFU/ml sonication fluid. No differences were found between PU and PVA foams. One type of organisms was found in 11 (16%), two in 17 (24%) and 3 or more in 40 (60%) foams. Gram-negative rods (Escherichia coli, Proteus mirabilis, Klebsiella pneumoniae, Acinetobacter baumanii, Pseudomonas aeruginosa) were isolated in 70%, followed by Staphylococcus aureus (20%), koagulase-negative staphylococci, streptococci (8%), and enterococci (2%).Conclusion: With sonication, a high density of bacteria present in VAC foams was demonstrated after a median of 3 days. Future studies are needed to investigate whether antimicrobial-impregnated foams can reduce the bacterial load in foams and potentially improve wound healing.
Resumo:
With the advent of new technologies, experience with long-term mechanical circulatory support (MCS) is rapidly growing. Candidates to MCS are selected based on concepts, strategies and classifications that are specific to this indication. As results drastically improve, supported by stronger scientific evidence, the trend is towards earlier implantation. An adequate pre-implant follow-up is mandatory in order to avoid missing the best window of opportunity for implantation. While on chronic support, the hemodynamic profile of patients with continuous-flow ventricular assist devices is unique and remarkably influenced by the hydration status. Optimal management of these patients from the pre-implant phase to the long-term support phase requires a multidisciplinary approach that is similar to that already long validated for organ transplantation.
Resumo:
PURPOSE: Poly(epsilon-caprolactone) (PCL) is a biodegradable and biocompatible polymer that presents a very low degradation rate, making it suitable for the development of long-term drug delivery systems. The objective of this pilot study is to evaluate the feasibility and characteristics of PCL devices in the prolonged and controlled intravitreous release of dexamethasone. METHODS: The in vitro release of dexamethasone was investigated and the implant degradation was monitored by the percent of mass loss and by changes in the surface morphology. Differential scanning calorimetry was used to evaluate stability and interaction of the implant and the drug. The short-term tolerance of the implants was studied after intravitreous implantation in rabbit eye. Results: PCL implant allows for a controlled and prolonged delivery of dexamethasone since it releases 25% of the drug in 21 weeks. Its low degradation rate was confirmed by the mass loss and scanning electron microscopy studies. Preliminary observations show that PCL intravitreous implants are very well tolerated in the rabbit eye. CONCLUSION: This study demonstrates the PCL drug delivery systems allowed to a prolonged release of dexamethasone in vitro. The implants demonstrated a strikingly good intraocular short-term tolerance in rabbits eyes. The in vitro and preliminary in vivo studies tend to show that PCL implants could be of interest when long-term sustained intraocular delivery of corticosteroids is required.
Resumo:
For enterococcal implant-associated infections, the optimal treatment regimen has not been defined. We investigated the activity of daptomycin, vancomycin, and gentamicin (and their combinations) against Enterococcus faecalis in vitro and in a foreign-body infection model. Antimicrobial activity was investigated by time-kill and growth-related heat production studies (microcalorimetry) as well as with a guinea pig model using subcutaneously implanted cages. Infection was established by percutaneous injection of E. faecalis in the cage. Antibiotic treatment for 4 days was started 3 h after infection. Cages were removed 5 days after end of treatment to determine the cure rate. The MIC, the minimal bactericidal concentration (MBC) in the logarithmic phase, and the MBC in the stationary phase were 1.25, 5, and >20 μg/ml for daptomycin, 1, >64, and >64 μg/ml for vancomycin, and 16, 32, and 4 μg/ml for gentamicin, respectively. In vitro, gentamicin at subinhibitory concentrations improved the activity against E. faecalis when combined with daptomycin or vancomycin in the logarithmic and stationary phases. In the animal model, daptomycin cured 25%, vancomycin 17%, and gentamicin 50% of infected cages. In combination with gentamicin, the cure rate for daptomycin increased to 55% and that of vancomycin increased to 33%. In conclusion, daptomycin was more active than vancomycin against adherent E. faecalis, and its activity was further improved by the addition of gentamicin. Despite a short duration of infection (3 h), the cure rates did not exceed 55%, highlighting the difficulty of eradicating E. faecalis from implants already in the early stage of implant-associated infection.
Resumo:
The indication for pulmonary artery banding is currently limited by several factors. Previous attempts have failed to produce adjustable pulmonary artery banding with reliable external regulation. An implantable, telemetrically controlled, battery-free device (FloWatch) developed by EndoArt SA, a medical company established in Lausanne, Switzerland, for externally adjustable pulmonary artery banding was evaluated on minipigs and proved to be effective for up to 6 months. The first human implant was performed on a girl with complete atrioventricular septal defect with unbalanced ventricles, large patent ductus arteriosus and pulmonary hypertension. At one month of age she underwent closure of the patent ductus arteriosus and FloWatch implantation around the pulmonary artery through conventional left thoracotomy. The surgical procedure was rapid and uneventful. During the entire postoperative period bedside adjustments (narrowing or release of pulmonary artery banding with echocardiographic assessment) were repeatedly required to maintain an adequate pressure gradient. The early clinical results demonstrated the clinical benefits of unlimited external telemetric adjustments. The next step will be a multi-centre clinical trial to confirm the early results and adapt therapeutic strategies to this promising technology.
Resumo:
BACKGROUND AND PURPOSE: Electrical bioimpedance spectroscopy (BIS) allows the evaluation of limb extracellular fluid (R0) and total fluid (Rinf). BIS could facilitate post-surgical oedema evaluation after total knee arthroplasty (TKA), as it is easily performed and is non-invasive. However, neither its applicability in this context nor the influence of metallic implants on measurement has been evaluated. The aim of this study was to evaluate the influence of TKA implants on the BIS R0 and Rinf variables used for oedema evaluation. METHOD: This was a prospective non-randomized comparative clinical trial. One oedema-free group of patients with TKA was compared with a group presenting similar characteristics except for the arthroplasty, to assess the influence of the implant on BIS measurement in the absence of oedema. The TKA group included 15 patients who had undergone surgery more than a year previously, and the control group included 19 patients awaiting TKA surgery. Volume and perimeter measurements served as reference criterions. The lower limb percentage differences for BIS, knee perimeter and volume were calculated. The significance of differences between groups was calculated for all measurement methods, using the Mann-Whitney test. The setting was a Department of Orthopedic Surgery and Traumatology in a university hospital. RESULTS: The differences between groups were not significant for R0, Rinf, volume and perimeter. R0 showed the smallest mean difference in limb percentage difference between groups [means (SD): TKA 3.98 (8.09), controls 3.97 (5.16)]. CONCLUSIONS: The lower-leg percentage difference in the TKA group is comparable with that of healthy subjects. R0 can be used for oedema evaluation following TKA surgery, as there was no sign of alteration from the metallic implant. These findings indicate the potential for early oedema evaluation after TKA. More research is warranted to extensively validate the application of BIS for oedema evaluation after TKA. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
INTRODUCTION: Reconstructions of the fronto-orbital area remain a challenge to the reconstructive surgeon, due to the functional and esthetic impact. OBSERVATION: The authors present a case of a complex fronto-orbital reconstruction with a PEEK (PolyEtherEtherKetone) implant, associated with a skin expansion. DISCUSSION: With a follow-up of over three years, the cosmetic result is excellent. The authors believe that this technique is reliable, fast with long-term good results.
Resumo:
Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.
Resumo:
Los cambios en los usos del suelo han contribuido de manera importante al incremento de gases de efecto invernadero en la atmósfera, especialmente de dióxido de carbono, aumentando sus emisiones desde 1970 en un 80%. Estos cambios causan la alteración de los suelos provocando un impacto sobre el ciclo del carbono, aumentando las tasas de descomposición de la fracción orgánica creando así un flujo de CO2 a la atmosfera. Entre las recomendaciones del Panel Intergubernamental de expertos sobre el Cambio Climático (IPCC, en inglés), y contemplado en el Protocolo de Kyoto, se encuentra el proceso de secuestro de carbono en suelos, que implica la eliminación del CO2 atmosférico por parte de las plantas y su almacenamiento como materia orgánica del suelo. Para poder favorecer dicho proceso, en un determinado tipo de ecosistema, es fundamental conocer cuáles son los factores que gobiernan la respiración del suelo y el impacto que tienen los diferentes usos en la emisión de CO2. En el presente trabajo se han estudiado 4 usos del suelo representativos del secano aragonés: un monocultivo de cebada en siembra directa (NT), un suelo abandonado labrado (AC), un suelo abandonado no alterado (AU) y un suelo forestal (FR) con el objetivo de conocer sus tasas de respiración, la influencia de diferentes parámetros edáficos en ellas, y proponer cambios en el uso del suelo que ayuden a mitigar estas emisiones. Además, se ha dedicado un apartado para conocer cómo influyen diferentes técnicas de fertilización nitrogenada (mineral y orgánica) en la respiración de un monocultivo de cebada en siembra directa. En cuanto a los usos, los resultados obtenidos tanto in situ como en laboratorio muestran una mayor respiración en AC, siendo los valores más bajos los de NT y FR. Una de las principales conclusiones es que la supresión del laboreo y del periodo de barbecho largo, así como la conversión de tierras abandonadas y marginales a cultivos y zonas forestales se presentan en este tipo de ecosistemas como prácticas de secuestro de carbono. En el estudio de aplicación de fertilizantes, no se observó ningún cambio en la respiración del suelo después de la aplicación de nitrógeno mineral. En cambio, el suelo fertilizado con purín sí que mostró picos de emisión durante las siguientes horas a la incorporación de éste, debido fundamentalmente a su alto contenido de carbono lábil.
Resumo:
This project is focused on the implant of a software, based in the integral management of a company, as OpenERP is.
Resumo:
Increasing antimicrobial resistance reduces treatment options for implant-associated infections caused by methicillin-resistant Staphylococcus aureus (MRSA). We evaluated the activity of fosfomycin alone and in combination with vancomycin, daptomycin, rifampin, and tigecycline against MRSA (ATCC 43300) in a foreign-body (implantable cage) infection model. The MICs of the individual agents were as follows: fosfomycin, 1 μg/ml; daptomycin, 0.125 μg/ml; vancomycin, 1 μg/ml; rifampin, 0.04 μg/ml; and tigecycline, 0.125 μg/ml. Microcalorimetry showed synergistic activity of fosfomycin and rifampin at subinhibitory concentrations against planktonic and biofilm MRSA. In time-kill curves, fosfomycin exhibited time-dependent activity against MRSA with a reduction of 2.5 log10 CFU/ml at 128 × the MIC. In the animal model, planktonic bacteria in cage fluid were reduced by <1 log10 CFU/ml with fosfomycin and tigecycline, 1.7 log10 with daptomycin, 2.2 log10 with fosfomycin-tigecycline and fosfomycin-vancomycin, 3.8 log10 with fosfomycin-daptomycin, and >6.0 log10 with daptomycin-rifampin and fosfomycin-rifampin. Daptomycin-rifampin cured 67% of cage-associated infections and fosfomycin-rifampin cured 83%, whereas all single drugs (fosfomycin, daptomycin, and tigecycline) and rifampin-free fosfomycin combinations showed no cure of MRSA cage-associated infections. No emergence of fosfomycin resistance was observed in animals; however, a 4-fold increase in fosfomycin MIC (from 2 to 16 μg/ml) occurred in the fosfomycin-vancomycin group. In summary, the highest eradication of MRSA cage-associated infections was achieved with fosfomycin in combination with rifampin (83%). Fosfomycin may be used in combination with rifampin against MRSA implant-associated infections, but it cannot replace rifampin as an antibiofilm agent.