958 resultados para High Reliability
Resumo:
This paper describes a modular solid-state switching cell derived from the Marx generator concept to be used in topologies for generating multilevel unipolar and bipolar high-voltage (HV) pulses into resistive loads. The switching modular cell comprises two ON/OFF semiconductors, a diode, and a capacitor. This cell can be stacked, being the capacitors charged in series and their voltages balanced in parallel. To balance each capacitor voltage without needing any parameter measurement, a vector decision diode algorithm is used in each cell to drive the two switches. Simulation and experimental results, for generating multilevel unipolar and bipolar HV pulses into resistive loads are presented.
Resumo:
Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.
Resumo:
OBJECTIVE To evaluate the validity and reliability of an instrument that evaluates the structure of primary health care units for the treatment of tuberculosis.METHODS This cross-sectional study used simple random sampling and evaluated 1,037 health care professionals from five Brazilian municipalities (Natal, state of Rio Grande do Norte; Cabedelo, state of Paraíba; Foz do Iguaçu, state of Parana; Sao José do Rio Preto, state of Sao Paulo, and Uberaba, state of Minas Gerais) in 2011. Structural indicators were identified and validated, considering different methods of organization of the health care system in the municipalities of different population sizes. Each structure represented the organization of health care services and contained the resources available for the execution of health care services: physical resources (equipment, consumables, and facilities); human resources (number and qualification); and resources for maintenance of the existing infrastructure and technology (deemed as the organization of health care services). The statistical analyses used in the validation process included reliability analysis, exploratory factor analysis, and confirmatory factor analysis.RESULTS The validation process indicated the retention of five factors, with 85.9% of the total variance explained, internal consistency between 0.6460 and 0.7802, and quality of fit of the confirmatory factor analysis of 0.995 using the goodness-of-fit index. The retained factors comprised five structural indicators: professionals involved in the care of tuberculosis patients, training, access to recording instruments, availability of supplies, and coordination of health care services with other levels of care. Availability of supplies had the best performance and the lowest coefficient of variation among the services evaluated. The indicators of assessment of human resources and coordination with other levels of care had satisfactory performance, but the latter showed the highest coefficient of variation. The performance of the indicators “training” and “access to recording instruments” was inferior to that of other indicators.CONCLUSIONS The instrument showed feasibility of application and potential to assess the structure of primary health care units for the treatment of tuberculosis.
Resumo:
OBJECTIVE To analyze the coverage of a cervical cancer screening program in a city with a high incidence of the disease in addition to the factors associated with non-adherence to the current preventive program.METHODS A cross-sectional study based on household surveys was conducted. The sample was composed of women between 25 and 59 years of age of the city of Boa Vista, RR, Northern Brazil who were covered by the cervical cancer screening program. The cluster sampling method was used. The dependent variable was participation in a women’s health program, defined as undergoing at least one Pap smear in the 36 months prior to the interview; the explanatory variables were extracted from individual data. A generalized linear model was used.RESULTS 603 women were analyzed, with an mean age of 38.2 years (SD = 10.2). Five hundred and seventeen women underwent the screening test, and the prevalence of adherence in the last three years was up to 85.7% (95%CI 82.5;88.5). A high per capita household income and recent medical consultation were associated with the lower rate of not being tested in multivariate analysis. Disease ignorance, causes, and prevention methods were correlated with chances of non-adherence to the screening system; 20.0% of the women were reported to have undergone opportunistic and non-routine screening.CONCLUSIONS The informed level of coverage is high, exceeding the level recommended for the control of cervical cancer. The preventive program appears to be opportunistic in nature, particularly for the most vulnerable women (with low income and little information on the disease). Studies on the diagnostic quality of cervicovaginal cytology and therapeutic schedules for positive cases are necessary for understanding the barriers to the control of cervical cancer.
Resumo:
Dissertation presented at the Faculty of Science and Technology of the New University of Lisbon in fulfillment of the requirements for the Masters degree in Electrical Engineering and Computers
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Informática Pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
ABSTRACTOBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context.METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants.RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods.CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts.
Resumo:
No literature data above atmospheric pressure could be found for the viscosity of TOTIVI. As a consequence, the present viscosity results could only be compared upon extrapolation of the vibrating wire data to 0.1 MPa. Independent viscosity measurements were performed, at atmospheric pressure, using an Ubbelohde capillary in order to compare with the vibrating wire results, extrapolated by means of the above mentioned correlation. The two data sets agree within +/- 1%, which is commensurate with the mutual uncertainty of the experimental methods. Comparisons of the literature data obtained at atmospheric pressure with the present extrapolated vibrating-wire viscosity measurements have shown an agreement within +/- 2% for temperatures up to 339 K and within +/- 3.3% for temperatures up to 368 K. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
In Part I of the present work we describe the viscosity measurements performed on tris(2-ethylhexyl) trimellitate or 1,2,4-benzenetricarboxylic acid, tris(2-ethylhexyl) ester (TOTM) up to 65 MPa and at six temperatures from (303 to 373)K, using a new vibrating-wire instrument. The main aim is to contribute to the proposal of that liquid as a potential reference fluid for high viscosity, high pressure and high temperature. The present Part II is dedicated to report the density measurements of TOTM necessary, not only to compute the viscosity data presented in Part I, but also as complementary data for the mentioned proposal. The present density measurements were obtained using a vibrating U-tube densimeter, model DMA HP, using model DMA5000 as a reading unit, both instruments from Anton Paar GmbH. The measurements were performed along five isotherms from (293 to 373)K and at eleven different pressures up to 68 MPa. As far as the authors are aware, the viscosity and density results are the first, above atmospheric pressure, to be published for TOTM. Due to TOTM's high viscosity, its density data were corrected for the viscosity effect on the U-tube density measurements. This effect was estimated using two Newtonian viscosity standard liquids, 20 AW and 200 GW. The density data were correlated with temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as +/- 0.2% at a 95% confidence level. Those results were correlated with temperature and pressure by a modified Tait equation, with deviations within +/- 0.25%. Furthermore, the isothermal compressibility, K-T, and the isobaric thermal expansivity, alpha(p), were obtained by derivation of the modified Tait equation used for correlating the density data. The corresponding uncertainties, at a 95% confidence level, are estimated to be less than +/- 1.5% and +/- 1.2%, respectively. No isobaric thermal expansivity and isothermal compressibility for TOTM were found in the literature. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2) for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.
Resumo:
Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.
Resumo:
This paper describes the hardware implementation of a High-Rate MIMO Receiver in an FPGA for three modulations, namely BPSK, QPSK and 16-QAM based on the Alamouti scheme. The implementation with 16-QAM achieves more than 1.6 Gbps with 66% of the resources of a medium-sized Virtex-4 FPGA. This results indicate that the Alamouti scheme is a good design option for hardware implementation of a high-rate MIMO receiver. Also, using an FPGA, the modulation can be dynamically changed on demand.
Resumo:
Feature selection is a central problem in machine learning and pattern recognition. On large datasets (in terms of dimension and/or number of instances), using search-based or wrapper techniques can be cornputationally prohibitive. Moreover, many filter methods based on relevance/redundancy assessment also take a prohibitively long time on high-dimensional. datasets. In this paper, we propose efficient unsupervised and supervised feature selection/ranking filters for high-dimensional datasets. These methods use low-complexity relevance and redundancy criteria, applicable to supervised, semi-supervised, and unsupervised learning, being able to act as pre-processors for computationally intensive methods to focus their attention on smaller subsets of promising features. The experimental results, with up to 10(5) features, show the time efficiency of our methods, with lower generalization error than state-of-the-art techniques, while being dramatically simpler and faster.
Resumo:
Dynamically reconfigurable SRAM-based field-programmable gate arrays (FPGAs) enable the implementation of reconfigurable computing systems where several applications may be run simultaneously, sharing the available resources according to their own immediate functional requirements. To exclude malfunctioning due to faulty elements, the reliability of all FPGA resources must be guaranteed. Since resource allocation takes place asynchronously, an online structural test scheme is the only way of ensuring reliable system operation. On the other hand, this test scheme should not disturb the operation of the circuit, otherwise availability would be compromised. System performance is also influenced by the efficiency of the management strategies that must be able to dynamically allocate enough resources when requested by each application. As those resources are allocated and later released, many small free resource blocks are created, which are left unused due to performance and routing restrictions. To avoid wasting logic resources, the FPGA logic space must be defragmented regularly. This paper presents a non-intrusive active replication procedure that supports the proposed test methodology and the implementation of defragmentation strategies, assuring both the availability of resources and their perfect working condition, without disturbing system operation.