992 resultados para Frequency stability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the efficiency of integrated managements on white mold control on common bean. Initially, in vitro testing was made to assess the antagonism of 11 Trichoderma isolates against Sclerotinia sclerotiorum and to investigate fungicides (fluazinam and procymidone) inhibitory effects on those fungi. In two field experiments the following combinations were tested: irrigation frequencies (seven or 14 days), plant densities (six or 12 plants per meter), and three disease controls (untreated control, fungicide or Trichoderma spp.). In a third experiment plant densities were replaced by grass mulching treatments (with or without mulching). Fluazinam was applied at 45 and 55 days after emergence (DAE). The antagonists T. harzianum (experiments 1 and 3) and T. stromatica (experiment 2) were applied through sprinkler irrigation at 10 and 25 DAE, respectively. Most of the Trichoderma spp. were effective against the pathogen in vitro. Fluazinam was more toxic than procymidone to both the pathogen and the antagonist. Fungicide applications increased yield between 32 % and 41 %. In field one application of Trichoderma spp. did not reduce disease intensity and did not increase yield. The reduction from 12 to six plants per meter did not decrease yield, and disease severity diminished in one of the two experiments. It is concluded that of the strategies for white mold control just reduction of plant density and applications of fungicide were efficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clonal cleaning, followed by pre-immunization with protective complexes of Citrus tristeza virus(CTV), allowed the commercial cultivation of Pêra sweet orange, a variety that has great importance for Brazilian citriculture but is sensitive to the virus. The use of mild protective isolates in other citrus varieties, even those more tolerant to CTV, can also be of interest to prevent the spread of severe isolates. The aim of this study was to characterize, by means of SSCP (Single Strand Conformational Polymorphism) analysis of the coat protein gene, CTV isolates present in plants of the sweet orange cultivars Pêra, Hamlin and Valencia propagated from four budwood sources: 1) old lines, 2) nucellar lines, 3) shoot-tip-grafted lines, and 4) shoot-tip-grafted lines pre-immunized with the mild CTV protective isolate 'PIAC'. We also evaluated the correlation of the obtained SSCP patterns to stem pitting intensity, tree vigor and fruit yield. SSCP results showed low genetic diversity among the isolates present in different trees of the same variety and same budwood source and, in some cases, in different budwood sources and varieties. Considering tristeza symptoms, lower intensity was noted for plants of new, shoot-tip-grafted and pre-immunized shoot-tip-grafted lines, compared to old lines of the three varieties. The observed SSCP patterns and symptomatology suggested that more severe CTV complexes infect the plants of old lines of all three varieties. The protective complex stability was observed in the SSCP patterns of CTV isolates of some shoot-tip-grafted and pre-immunized clones. It was concluded that the changes detected in other electrophoretic profiles of this treatment did not cause loss of the protective capacity of CTV isolate 'PIAC' inoculated in the pre-immunization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One hundred different 5.5-year-old Eucalyptus grandis x Eucalyptus urophylla wood clones were cooked to kappa number 15-17.5 and the resulting kraft pulps oxygen-delignified to kappa 9.5-11.5 under fixed conditions, except for chemical charges. Thirteen samples showing large variations in effective alkali requirement, pulp yield and O-stage efficiency and selectivity were selected for brightness reversion studies. These samples were bleached to 90-91% ISO by DEDD and DEDP sequences and their brightness stability and chemical characteristics determined. Heat reversion of the eucalyptus kraft pulps was strongly influenced by the wood supply, with brightness loss varying in the range of 2.1-3.6 and 0.8-1.7 %ISO for ODEDD and ODEDP bleached pulps, respectively. Pulps bleached by the ODEDP sequence showed reversion values 1.3-1.9 % ISO lower than those bleached by the ODEDD sequence. Pulp carbonyl content decreased by 35-40% during the final peroxide bleaching stage. Carbonyl and carboxyl groups correlated positively with brightness reversion, as did permanganate number and acid soluble lignin. Pulp final viscosity and metal and DCM extractives contents showed no significant correlation with brightness reversion. Pulping, oxygen delignification and ECF bleaching performances also showed no correlation with brightness reversion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resonance energy transfer (RET) is a non-radiative transfer of the excitation energy from the initially excited luminescent donor to an acceptor. The requirements for the resonance energy transfer are: i) the spectral overlap between the donor emission spectrum and the acceptor absorption spectrum, ii) the close proximity of the donor and the acceptor, and iii) the suitable relative orientations of the donor emission and the acceptor absorption transition dipoles. As a result of the RET process the donor luminescence intensity and the donor lifetime are decreased. If the acceptor is luminescent, a sensitized acceptor emission appears. The rate of RET depends strongly on the donor–acceptor distance (r) and is inversely proportional to r6. The distance dependence of RET is utilized in binding assays. The proximity requirement and the selective detection of the RET-modified emission signal allow homogeneous separation free assays. The term lanthanide-based RET is used when luminescent lanthanide compounds are used as donors. The long luminescence lifetimes, the large Stokes’ shifts and the intense, sharply-spiked emission spectra of the lanthanide donors offer advantages over the conventional organic donor molecules. Both the organic lanthanide chelates and the inorganic up-converting phosphor (UCP) particles have been used as donor labels in the RET based binding assays. In the present work lanthanide luminescence and lanthanide-based resonance energy transfer phenomena were studied. Luminescence lifetime measurements had an essential role in the research. Modular frequency-domain and time-domain luminometers were assembled and used successfully in the lifetime measurements. The frequency-domain luminometer operated in the low frequency domain ( 100 kHz) and utilized a novel dual-phase lock-in detection of the luminescence. One of the studied phenomena was the recently discovered non-overlapping fluorescence resonance energy transfer (nFRET). The studied properties were the distance and temperature dependences of nFRET. The distance dependence was found to deviate from the Förster theory and a clear temperature dependence was observed whereas conventional RET was completely independent of the temperature. Based on the experimental results two thermally activated mechanisms were proposed for the nFRET process. The work with the UCP particles involved the measurement of the luminescence properties of the UCP particles synthesized in our laboratory. The goal of the UCP particle research is to develop UCP donor labels for binding assays. In the present work the effect of the dopant concentrations and the core–shell structure on the total up-conversion luminescence intensity, the red–green emission ratio, and the luminescence lifetime was studied. Also the non-radiative nature of the energy transfer from the UCP particle donors to organic acceptors was demonstrated for the first time in aqueous environment and with a controlled donor–acceptor distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensity-duration-frequency occurrence ratio (IDF) is a tool commonly used for precipitation-runoff data transformation, which is established from observations of intense precipitations over a period sufficiently long as to allow the occurrence of extremes at the observation site. This study focused on verifying the existence or absence of new data, in terms of IDF ratio, by using partial duration records produced from data on maximum daily disaggregated rainfall for pre determined durations. The partial duration records considered a base value of 55 mm, totaling 279 values. After the rainfall series were established, their independence and seasonality were assessed. Using the Student's t-test statistics, it was established that no new data, as IDF ratio, emerged from the analysis of the partial duration series with the recommended base value of precipitation, as compared to the historical records.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensity, duration, and frequency relationship (IDF) of rainfall occurrence may be done through continuous records of pluviographs or daily pluviometer values . The objective of this study was to estimate the intensity-duration-frequency relationships of precipitation, using the method of daily rainfall disaggregation, at weather stations located to the southern half of the state of Rio Grande do Sul; comparing them with those obtained by rain gauge records, in places considered homogeneous from the meteorological point of view. The IDF equation parameters were estimated from daily rainfall disaggregation data, using the method of nonlinear optimization. To validate the equations confidence indices and efficiency and the "t" Student test, among maximum intensity values obtained from the disaggregated daily rainfall durations of 10; 30; 60 min and 6; 12 and 24 h and those extracted from existing IDF equations. For all studied stations and return periods, the trust index values were regarded as "optimal", i.e., greater than 0.85. The maximal intensity of rainfall obtained by daily rainfall disaggregation have similarity with those obtained by relations IDF standards. Thus, the method constitutes a feasible alternative in obtaining the IDF relationships.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the lack of information concerning maximum rainfall equations for most locations in Mato Grosso do Sul State, the alternative for carrying out hydraulic work projects has been information from meteorological stations closest to the location in which the project is carried out. Alternative methods, such as 24 hours rain disaggregation method from rainfall data due to greater availability of stations and longer observations can work. Based on this approach, the objective of this study was to estimate maximum rainfall equations for Mato Grosso do Sul State by adjusting the 24 hours rain disaggregation method, depending on data obtained from rain gauge stations from Dourado and Campo Grande. For this purpose, data consisting of 105 rainfall stations were used, which are available in the ANA (Water Resources Management National Agency) database. Based on the results we concluded: the intense rainfall equations obtained by pluviogram analysis showed determination coefficient above 99%; and the performance of 24 hours rain disaggregation method was classified as excellent, based on relative average error WILMOTT concordance index (1982).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä työ on tehty Fingrid Oyj:lle. Työn tavoitteena oli tutkia, miten reaaliaikaista PMU-mittaustietoa voidaan hyödyntää voimajärjestelmän valvonnassa. Voimajärjestelmän dynaamisia ilmiöitä ovat jännite- ja kulmastabiilius. Työssä tutkittiin voimajärjestelmän kulmastabiiliutta PSS/E-ohjelmalla simuloitujen mittaustulosten perusteella. Fouriermuunnoksen tulokset osoittavat, että huonoiten vaimeneva taajuuskomponentti on 0,3 Hz taajuus. Lisäksi tiedetään, että huonosti vaimeneva taajuuskomponentti rajoittaa siirtokapasiteettia. Voimajärjestelmän stabiiliutta voidaan esittää Wide Area Monitoring -järjestelmien (WAMS) avulla. WAMS perustuu Phasor Measurement -laitteen (PMU) reaaliaikaiseen mittaustekniikkaan. Jännitteen vaihekulman mittaaminen mahdollistaa voimajärjestelmän tilan määrittämisen reaaliajassa. Työssä on esitelty Fingridin käytössä oleva WAMS ja lisäksi esitelty kolmen eri laitetoimittajan WAMS:n rakennetta ja operaattorin käyttöön tarkoitettuja käyttöliittymiä. WAMS:n rakenteet ovat pääpiirteittäin samanlaisia, mutta stabiiliuden visuaalisessa esittämisessä on eroja. PMU -mittaustietoja on mahdollista tuoda käytönvalvontajärjestelmään erillisellä tiedonsiirtoprotokollalla. PMU-mittaustiedon hyödyntäminen käytönvalvontajärjestelmän toimintaaluenäytöllä mahdollistaa verkon tilan esittämisen reaaliajassa. Roottorin kulmastabiilius esitetään Fingridin käytönvalvontajärjestelmässä vaihekulmaerojen avulla ja työssä on esitetty, kuinka vaihekulmaeron arvolla on vaikutus tehonsiirtoon. Vaihekulmaeron arvo kuvaa vian jälkeisen tehoheilahtelun voimakkuutta. PMU-mittaustiedon esittäminen antaa operaattorille selkeämmän kuvan ylläpitää tehonsiirto turvallisella tasolla ja epästabiilin heilahtelun havainnoiminen vähentää suurhäiriön riskiä. Tulevaisuudessa siirtoverkon kehittyessä tarvitaan operaattorin käyttöön myös nopeita stabiilisuutta esittäviä työkaluja.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pluripotent cells have the potential to differentiate into all somatic cell types. As the adult human body is unable to regenerate various tissues, pluripotent cells provide an attractive source for regenerative medicine. Human embryonic stem cells (hESCs) can be isolated from blastocyst stage embryos and cultured in the laboratory environment. However, their use in regenerative medicine is restricted due to problems with immunosuppression by the host and ethical legislation. Recently, a new source of pluripotent cells was established via the direct reprogramming of somatic cells. These human induced pluripotent stem cells (hiPSCs) enable the production of patient specific cell types. However, numerous challenges, such as efficient reprogramming, optimal culture, directed differentiation, genetic stability and tumor risk need to be solved before the launch of therapeutic applications. The main objective of this thesis was to understand the unique properties of human pluripotent stem cells. The specific aims were to identify novel factors involved in maintaining pluripotency, characterize the effects of low oxygen culture on hESCs, and determine the high resolution changes in hESCs and hiPSCs during culture and reprogramming. As a result, the previously uncharacterized protein L1TD1 was determined to be specific for pluripotent cells and essential for the maintenance of pluripotency. The low oxygen culture supported undifferentiated growth and affected expression of stem cell associated transcripts. High resolution screening of hESCs identified a number of culture induced copy number variations and loss of heterozygosity changes. Further, screening of hiPSCs revealed that reprogramming induces high resolution alterations. The results obtained in this thesis have important implications for stem cell and cancer biology and the therapeutic potential of pluripotent cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTObjective:to compare the frequency and the severity of diagnosed injuries between pedestrians struck by motor vehicles and victims of other blunt trauma mechanisms.Methods:retrospective analysis of data from the Trauma Registry, including adult blunt trauma patients admitted from 2008 to 2010. We reviewed the mechanism of trauma, vital signs on admission and the injuries identified. Severity stratification was carried using RTS, AIS-90, ISS e TRISS. Patients were assigned into group A (pedestrians struck by motor vehicle) or B (victims of other mechanisms of blunt trauma). Variables were compared between groups. We considered p<0.05 as significant.Results:a total of 5785 cases were included, and 1217 (21,0%) of which were in group A. Pedestrians struck by vehicles presented (p<0.05) higher mean age, mean heart rate upon admission, mean ISS and mean AIS in head, thorax, abdomen and extremities, as well as lower mean Glasgow coma scale, arterial blood pressure upon admission, RTS and TRISS. They also had a higher frequency of epidural hematomas, subdural hematomas, subarachnoid hemorrhage, brain swelling, cerebral contusions, costal fractures, pneumothorax, flail chest, pulmonary contusions, as well as pelvic, superior limbs and inferior limbs fractures.Conclusion:pedestrian struck by vehicles sustained intracranial, thoracic, abdominal and extremity injuries more frequently than victims of other blunt trauma mechanism as a group. They also presented worse physiologic and anatomic severity of the trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the frequency of fear of needles and the impact of a multidisciplinary educational program in women with pre-gestational and gestational diabetes taking insulin during pregnancy. METHODS: The short Diabetes Fear of Injecting and Self-testing Questionnaire (D-FISQ), composed by two subscales that access fear of self injection (FSI) and fear of self testing (FST), was administered twice during pregnancy to 65 pregnant women with pre-gestational and gestational diabetes: at the first endocrine consult and within the last two weeks of pregnancy or postpartum. An organized multidisciplinary program provided diabetes education during pregnancy. Statistical analysis was carried out by Wilcoxon and McNemar tests and Spearman correlation. A p<0.05 was considered to be significant. RESULTS: Data from the short D-FISQ questionnaire shows that 43.1% of pregnant women were afraid of needles in the first evaluation. There was a significant reduction in scores for FSI and FST subscales between the first and second assessments (first FSI 38.5% compared with second 12.7%, p=0.001; first FST 27.7% compared with second FST 14.3%, p=0.012). CONCLUSIONS: The fear of needles is common in pregnant women on insulin therapy and an organized multidisciplinary educational diabetes program applied during pregnancy reduces scores of such fear.