956 resultados para Fractures, Bone.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone marrow-derived endothelial progenitor cells (EPCs) infiltrate into sites of neovascularization in adult tissues and mature into functional blood endothelial cells (BECs) during a process called vasculogenesis. Human marrow-derived EPCs have recently been reported to display a mixed myeloid and lymphatic endothelial cell (LEC) phenotype during inflammation-induced angiogenesis; however, their role in cancer remains poorly understood. We report the in vitro differentiation of human cord blood CD133(+)CD34(+) progenitors into podoplanin(+) cells expressing both myeloid markers (CD11b, CD14) and the canonical LEC markers vascular endothelium growth factor receptor 3 (VEGFR-3), lymphatic vessel endothelial hyaluronan receptor 1 (LYVE-1), and prospero homeobox 1 (PROX-1). These podoplanin(+) cells displayed sprouting behavior comparable to that of LECs in vitro and a dual hemangiogenic and lymphangiogenic activity in vivo in an endothelial cell sprouting assay and corneal vascularization assay, respectively. Furthermore, these cells expressed vascular endothelium growth factor (VEGF) family members A, -C, and -D. Thus, bone-marrow derived EPCs stimulate hemangiogenesis and lymphangiogenesis through their ability to differentiate into LECs and to produce angiogenic factors. Importantly, plasma from patients with breast cancer induced differentiation of CD34(+) cord blood progenitors into hemangiogenic and lymphangiogenic CD11b(+) myeloid cells, whereas plasma from healthy women did not have this effect. Consistent with these findings, circulating CD11b(+) cells from breast cancer patients, but not from healthy women, displayed a similar dual angiogenic activity. Taken together, our results show that marrow-derived EPCs become hemangiogenic and lymphangiogenic upon exposure to cancer plasma. These newly identified functions of bone-marrow derived EPCs are expected to influence the diagnosis and treatment of breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le maintien d'une concentration sanguine constante de calcium est d'une importance cruciale et trois organes participent à la balance calcique normale : les reins, les intestins et les os. La concentration plasmatique de calcium est strictement régulée par l'hormone parathyroïdienne (PTH) et par la vitamine D. Des variations circadiennes de la PTH, de la vitamine D ainsi que du calcium plasmatique ont été décrites précédemment chez l'humain ainsi que chez le rat. Ces rythmes de PTH dans le sérum sont importants pour la régulation du remodelage de l'os. En effet, il a été montré chez les souris C57BL/6J que des injections de PTH une fois par jour mènent à une augmentation de la densité minérale de l'os alors que l'infusion en continu de PTH est associée à une diminution de cette densité. La vitamine D joue également un rôle fondamental dans la physiologie osseuse, car un déficit en vitamine D peut conduire à une ostéomalacie. Cependant la fonction des oscillations de vitamine D au niveau de l'homéostasie osseuse reste inconnue. L'horloge circadienne est un système interne de contrôle biologique du temps générant des rythmes de 24 heures dans l'expression des gènes, ainsi que dans la physiologie et le comportement. Ce contrôle s'opère par des boucles rétroactives positives et négatives de l'expression de gènes circadiens tels que CLOCK, BMAL1, CRY1 et 2 ou PERI et 2. Dans ce travail, nous avons émis l'hypothèse que l'homéostasie calcique est sous le contrôle de l'horloge circadienne. Dans un premier temps, nous avons montré chez les souris C57BL/6J des variations journalières des concentrations de calcium, de PTH et de vitamine D dans le sang, ainsi que de calcium dans les urines. Nous avons également démontré des changements au niveau de l'expression rénale des gènes importants dans l'homéostasie du calcium, tant au niveau de l'ARN messager que des protéines. Ensuite, pour analyser le rôle du système de l'horloge circadienne dans l'homéostasie du calcium, nous avons étudié des souris dans lesquelles a été supprimé le gène CLOCK crucial pour la fonction de l'horloge et nous avons comparé ces souris à des souris de type sauvage de même portée. Les souris CLOCK-I- étaient hypercalciuriques à chaque moment de la journée. Cependant le rythme circadien de l'excrétion de calcium était préservé. Le taux de calcium plasmatique ne différait pas entre les génotypes, mais les souris CLOCK -/- ne montraient pas de variations journalières de ce paramètre. Une perte du rythme journalier était également observée pour les niveaux de vitamine D, perte qui pourrait être une cause de l'altération de la micro-architecture osseuse révélée chez les souris CLOCK-/-. En effet, ces souris montrent une diminution du nombre de trabécules, de leur volume ainsi que de leur surface, ce qui suggère la présence d'ostéoporose. Nous avons également trouvé que le rythme de l'expression de l'ARN messager de CYP27B1 était aboli dans les reins des souris CLOCK -/-, ce qui peut expliquer l'altération du rythme de la vitamine D. Les taux sanguins de PTH étaient comparables entre les souris CLOCK -/- et de type sauvage. Dans les reins, une augmentation de l'expression de l'ARN messager de TRPV5 et NCX1 a été constatée, ce qui suggérerait une augmentation de la réabsorption de calcium dans le tubule convoluté distal et dans le tubule connecteur. Dans les intestins, la réabsorption calcique était diminuée, chez les souris CLOCK-I-, fait confirmé par une diminution des niveaux d'ARN messager de TRPV6 et PMCAL. En résumé, la suppression du gène CLOCK chez les souris a conduit à une hypercalciurie, une altération du rythme des taux plasmatiques de calcium et de vitamine D et à une détérioration de l'architecture osseuse. Pour conclure, ces résultats montrent que l'horloge circadienne est essentielle à l'homéostasie calcique ainsi qu'à la physiologie des os. - L'ostéoporose affecte environ 22 millions de femmes et 5.5 millions d'hommes en Europe, réduisant significativement leur qualité de vie et a causé 3.5 millions de nouvelles fractures en 2010. Les dépenses totales liées à ces fractures ont atteint 37 milliards d'euro et ce coût devrait augmenter de 25% d'ici à 2025. Le nombre de nouvelles fractures dues à l'ostéoporose à travers le monde est estimé à environ 1000 par heure. Parmi les causes de l'ostéoporose, le déficit én calcium et/ou en vitamine D joue un rôle important, mais il existe également des causes génétiques ou liées à des facteurs comme les hormones sexuelles (estrogènes, testostérone), l'âge, le tabac, le poids corporel, certains médicaments,... La vie est rythmique : ceci est dû à l'alternance naturelle du jour et de la nuit et de ses effets sur le corps. La prise alimentaire, par exemple, est un processus qui a lieu pendant la phase active, qui est prévisible (il se produit toujours au même moment) et qui peut être anticipé par le corps. Pour cela, une horloge interne est présente dans chaque cellule du corps et est synchronisée par la lumière du jour, entre autres stimuli. Cette horloge indique la phase du jour et régule l'expression de gènes impliqués dans les différents processus qui nécessitent une anticipation. Pendant mon travail de thèse, je me suis demandé si des îythmes circadiens (c'est-à-dire d'une durée d'environ 24 heures et indépendants des stimuli externes) étaient observables'pour les gènes régulant les flux de calcium dans le corps et si l'interruption de ces rythmes pouvait mener à des altérations de la qualité de l'os. J'ai d'abord travaillé avec des souris normales et j'ai pu montrer la présence de rythmes au niveau du calcium sanguin et urinaire, mais également au niveau des hormones et gènes qui contrôlent le métabolisme du calcium dans le corps, comme la vitamine D et l'hormone parathyroidienne. De manière intéressante, j'ai observé que la plupart de ces gènes ont un rythme synchronisé. J'ai ensuite utilisé un modèle de souris dans lequel l'horloge interne a été génétiquement invalidée et j'ai montré que ces souris présentent une augmentation de leur excrétion urinaire de calcium et un rythme circadien altéré de la vitamine D dans le sang. Ces souris absorbent aussi moins bien le calcium intestinal et présentent une ostéoporose marquée. Ce travail montre donc que l'horloge interne est nécessaire pour établir un rythme circadiens de certains facteurs influant les flux de calcium dans l'organisme, comme la vitamine D, et que la perturbation de ces rythmes mène à une dérégulation du métabolisme osseux. Ainsi, la perturbation de l'horloge interne peut causer une ostéoporose et une hypercalciurie qui pourraient aboutir à la formation de fractures et de calculs rénaux. L'extrapolation de ces observations chez l'homme ou à des changements plus subtiles des rythmes circadiens, comme le décalage horaire, restent à montrer. Cette recherche a démontré que les rythmes circadiens des mécanismes de régulation des flux de calcium dans l'organisme sont essentiels au maintien d'un squelette normal et suggère que les perturbations des rythmes circadiens pourraient être une nouvelle cause de l'ostéoporose. - Maintaining constant calcium concentration in the plasma is of a crucial importance and three organs participate in normal calcium balance - kidney, gut and bone. Plasma calcium concentration is strictly regulated by parathyroid hormone (PTH) and vitamin D. Circadian variations of PTH, vitamin D and plasma calcium were previously described in humans, as well as in rats. Rhythms in serum PTH are important for balanced bone remodelling. Indeed in C57BL/6J mice, PTH injection once per day leads to an increase in bone mineral density (BMD), whilst continuous infusion is associated with decreased BMD. Vitamin D also plays a crucial role in bone physiology, since the deficiency in vitamin D can lead to rickets/osteomalacia. However, the role of vitamin D rhythms in bone homeostasis remains unknown. The circadian clock is an. internal time-keeping system generating rhythms in gene expression with 24h periodicity, in physiology and in behaviour. It is operated by positive- and negative-feedback loops of circadian genes, such as CLOCK, BMAL1, CRY1 and 2 or PERI and 2. In this work, we hypothesized, that calcium homeostasis is under the control of the circadian clock. First, we showed daily variations in urinary calcium and serum calcium, PTH and l,25(OH)2 vitamin D, together with renal mRNA and protein levels of genes involved in calcium homeostasis in C57BL/6J mice. Second, and to investigate the role of the circadian clock system in calcium handling, we studied mice lacking the gene CLOCK crucial for fonction of the clock system and compared them to the WT littermates. CLOCK-/- mice were hypercalciuric at all timepoints of the day. However, the circadian rhythm of calcium excretion was preserved. Serum calcium levels did not differ between the genotypes, but CLOCK-/- mice did not exhibit daily variation for this parameter. Loss of rhythm was observed also for serum l,25(OH)2 vitamin D levels, which may be one of the causes of altered bone microarchitecture that was revealed in CLOCK-/- mice. They displayed increased trabecular separation and decreased trabecular number, trabecular bone volume and trabecular bone surface, suggestive of osteoporosis. We found that the rhythm of the mRNA expression of CYP27B1 was abolished in the kidney of CLOCK-/- mice, which could induce the altered rhythm of l,25(OH)2 vitamin. Serum PTH levels were comparable between CLOCK-/- and WT mice. In the kidney, increased mRNA expression of TRPV5 and NCX1 suggests increased calcium reabsorption in the distal convoluted and connecting tubule. In the gut, intestinal calcium absorption was decreased in CLOCK¬/- mice, confirmed by decreased mRNA levels of TRPV6 and PMCA1. In summary, deletion of the CLOCK gene in mice conducts to hypercalciuria, alteration of the rhythm in serum calcium and l,25(OH)2D levels, and impainnent of their bone microarchitecture. In conclusion, these data show that the circadian clock system is essential in calcium homeostasis and bone physiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a large prospective cohort of over 12,000 women, we determined 2 thresholds (high risk and low risk of hip fracture) to use in a 10-yr hip fracture probability model that we had previously described, a model combining the heel stiffness index measured by quantitative ultrasound (QUS) and a set of easily determined clinical risk factors (CRFs). The model identified a higher percentage of women with fractures as high risk than a previously reported risk score that combined QUS and CRF. In addition, it categorized women in a way that was quite consistent with the categorization that occurred using dual X-ray absorptiometry (DXA) and the World Health Organization (WHO) classification system; the 2 methods identified similar percentages of women with and without fractures in each of their 3 categories, but the 2 identified only in part the same women. Nevertheless, combining our composite probability model with DXA in a case findings strategy will likely further improve the detection of women at high risk of fragility hip fracture. We conclude that the currently proposed model may be of some use as an alternative to the WHO classification criteria for osteoporosis, at least when access to DXA is limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Dietary acid charge enhances bone loss. Bicarbonate or alkali diet decreases bone resorption in humans. We compared the effect of an alkaline mineral water, rich in bicarbonate, with that of an acid one, rich in calcium only, on bone markers, in young women with a normal calcium intake. METHODS: This study compared water A (per litre: 520 mg Ca, 291 mg HCO(3)(-), 1160 mg SO(4)(-), Potential Renal Acid load (PRAL) +9.2 mEq) with water B (per litre: 547 mg Ca, 2172 mg HCO(3)(-), 9 mg SO(4)(-), PRAL -11.2 mEq). 30 female dieticians aged 26.3 yrs (SD 7.3) were randomized into two groups, followed an identical weighed, balanced diet (965 mg Ca) and drank 1.5 l/d of the assigned water. Changes in blood and urine electrolytes, C-telopeptides (CTX), urinary pH and bicarbonate, and serum PTH were measured after 2 and 4 weeks. RESULTS: The two groups were not different at baseline, and showed a similar increase in urinary calcium excretion. Urinary pH and bicarbonate excretion increased with water B, but not with water A. PTH (p=0.022) and S-CTX (p=0.023) decreased with water B but not with water A. CONCLUSION: In calcium sufficiency, the acid calcium-rich water had no effect on bone resorption, while the alkaline water rich in bicarbonate led to a significant decrease of PTH and of S-CTX.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of defects in the craniomaxillofacial (CMF) area has mainly been based on bone grafts or metallic fixing plates and screws. Particularly in the case of large calvarial and/or craniofacial defects caused by trauma, tumours or congenital malformations, there is a need for reliable reconstruction biomaterials, because bone grafts or metallic fixing systems do not completely fulfill the criteria for the best possible reconstruction methods in these complicated cases. In this series of studies, the usability of fibre-reinforced composite (FRC) was studied as a biostable, nonmetallic alternative material for reconstructing artificially created bone defects in frontal and calvarial areas of rabbits. The experimental part of this work describes the different stages of the product development process from the first in vitro tests with resin-impregnated fibrereinforced composites to the in vivo animal studies, in which this FRC was tested as an implant material for reconstructing different size bone defects in rabbit frontal and calvarial areas. In the first in vitro study, the FRC was polymerised in contact with bone or blood in the laboratory. The polymerised FRC samples were then incubated in water, which was analysed for residual monomer content by using high performance liquid chromatography (HPLC). It was found that this in vitro polymerisation in contact with bone and blood did not markedly increase the residual monomer leaching from the FRC. In the second in vitro study, different adhesive systems were tested in fixing the implant to bone surface. This was done to find an alternative implant fixing system to screws and pins. On the basis of this study, it was found that the surface of the calvarial bone needed both mechanical and chemical treatments before the resinimpregnated FRC could be properly fixed onto it. In three animal studies performed with rabbit frontal bone defects and critical size calvarial bone defect models, biological responses to the FRC implants were evaluated. On the basis of theseevaluations, it can be concluded that the FRC, based on E-glass (electrical glass) fibres forming a porous fibre veil enables the ingrowth of connective tissues to the inner structures of the material, as well as the bone formation and mineralization inside the fibre veil. Bone formation could be enhanced by using bioactive glass granules fixed to the FRC implants. FRC-implanted bone defects healed partly; no total healing of defects was achieved. Biological responses during the follow-up time, at a maximum of 12 weeks, to resin-impregnated composite implant seemed to depend on the polymerization time of the resin matrix of the FRC. Both of the studied resin systems used in the FRC were photopolymerised and the heat-induced postpolymerisation was used additionally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Quantitative ultrasound (QUS) is an attractive method for assessing fracture risk because it is portable, inexpensive, without ionizing radiation, and available in areas of the world where DXA is not readily accessible or affordable. However, the diversity of QUS scanners and variability of fracture outcomes measured in different studies is an important obstacle to widespread utilisation of QUS for fracture risk assessment. We aimed in this review to assess the predictive power of heel QUS for fractures considering different characteristics of the association (QUS parameters and fracture outcomes measured, QUS devices, study populations, and independence from DXA-measured bone density).Materials/Methods : We conducted an inverse-variance randomeffects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound &SOS;, stiffness index &SI;, and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic, and major osteoporotic fractures) were reported based on study questions.Results : 21 studies including 55,164 women and 13,742 men were included with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fractures. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99), and QUI was 1.99 (95% CI 1.49-2.67). Validated devices from different manufacturers predicted fracture risks with a similar performance (meta-regression p-values>0.05 for difference of devices). There was no sign of publication bias among the studies. QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip DXA showed a significant and independent association with fracture risk (RR/SD for BUA =1.34 [95%CI 1.22-1.49]).Conclusions : This study confirms that QUS of the heel using validated devices predicts risk of different fracture outcomes in elderly men and women. Further research and international collaborations are needed for standardisation of QUS parameters across various manufacturers and inclusion of QUS in fracture risk assessment tools. Disclosure of Interest : None declared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Screening for osteoporosis is important in older patients admitted to post-acute rehabilitation. However, DXA measurement is sometimes difficult to perform because of difficulties in positioning the patient and artefacts (osteoarthritis, prosthesis). The objectives were to determine the prevalence of unknown clinical osteoporosis in rehab patients and to determine new strategies for identifying clinical osteoporosis in this population. Method: Over a 9-months period, patients consecutively admitted to post-acute rehabilitation were included in th stdy. Patients with osteoporosis diagnosis, and those with terminal illness or severe physical limitations were excluded. Patients underwent Bone Mineral Density (BMD) by DXA and Vertebral Fracture Assessment (VFA). Clinical osteoporosis was defined as BMD ≤-2.5 SD at any site (lumbar spine, femoral neck, total hip or distal radius), ≥1 vertebral fracture, ≥1 hip fracture, or another fragility fracture and BMD ≤-2 SD. Results: Overall, 102 (17.0%) of the 600 patients admitted to rehab refused to participate in the study or were unable to consent. Among the 498 remaining patients, 99 (19.9%) were excluded because of already known diagnosis of osteoporosis, 101 (20.3%) were excluded because of terminal illness, severe physical limitations, and 45 (9.0%) because of inability to perform DXA during the stay (death, hospital transfer). Overall, 253 patients were assessed with DXA and VFA (166 women, mean age 83±7 years, mean BMI 27±6 kg/m2, and 87 men, mean age 82±6 yrs, mean BMI 27±5 kg/m2). Of these, 70% had history of fall during the last 6 months and 9.1% had hip fracture history. Prevalence of osteoporotic vertebral fracture was 36% in women and 32% in men. Overall, 152 (60.1%) patients had clinical osteoporosis (women: 67%; men: 46%) according to above criteria. Hip fracture history and vertebral fracture assessment identified correctly 105 (69.1%) of these 152 patients. Conclusion: A high prevalence of osteoporosis was observed in this population of rehab patients. Osteoporosis status should be systematically assessed in these patients at high fall risk, at least with careful history of hip fracture and an assessment for vertebral fractures with spine X-ray.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human motion study, which relies on mathematical and computational models ingeneral, and multibody dynamic biomechanical models in particular, has become asubject of many recent researches. The human body model can be applied to different physical exercises and many important results such as muscle forces, which are difficult to be measured through practical experiments, can be obtained easily. In the work, human skeletal lower limb model consisting of three bodies in build using the flexible multibody dynamics simulation approach. The floating frame of reference formulation is used to account for the flexibility in the bones of the human lower limb model. The main reason of considering the flexibility inthe human bones is to measure the strains in the bone result from different physical exercises. It has been perceived the bone under strain will become stronger in order to cope with the exercise. On the other hand, the bone strength is considered and important factors in reducing the bone fractures. The simulation approach and model developed in this work are used to measure the bone strain results from applying raising the sole of the foot exercise. The simulation results are compared to the results available in literature. The comparison shows goof agreement. This study sheds the light on the importance of using the flexible multibody dynamic simulation approach to build human biomechanical models, which can be used in developing some exercises to achieve the optimalbone strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract:The objective of this work was to evaluate the effect of limestone particle sizes in the diet and of lighting regimes on the egg and bone quality and on the performance of commercial laying hens. Three hundred Hissex White layers, at 18 weeks of age, were distributed in a completely randomized design, in a 5×2 factorial arrangement (coarse limestone in the diet at 0, 25, 50, 75, and 100%; with or without artificial light), with five replicates of six birds. No significant interaction was observed between particle sizes and lighting regime for the evaluated parameters. There was no significant effect of coarse limestone level in the diet on the performance and egg quality of hens; however, bone deformity (3.23 to 4.01 mm), strength (5.19 to 6.70 kgf cm-2), and mineral matter (51.09 to 59.61%) improved as the proportion of coarse limestone increased. For lighting regime, the treatment with artificial light yielded higher Haugh unit values (87.17 vs. 85.54) than that with natural light only. Greater limestone particles improve bone quality of laying hens, and the use of artificial light can benefit the albumen quality of the eggs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.