986 resultados para Feeder reconfiguration of distribution systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enterprise systems interoperability (ESI) is an important topic for business currently. This situation is evidenced, at least in part, by the number and extent of potential candidate protocols for such process interoperation, viz., ebXML, BPML, BPEL, and WSCI. Wide-ranging support for each of these candidate standards already exists. However, despite broad acceptance, a sound theoretical evaluation of these approaches has not yet been provided. We use the Bunge-Wand-Weber (BWW) models, in particular, the representation model, to provide the basis for such a theoretical evaluation. We, and other researchers, have shown the usefulness of the representation model for analyzing, evaluating, and engineering techniques in the areas of traditional and structured systems analysis, object-oriented modeling, and process modeling. In this work, we address the question, what are the potential semantic weaknesses of using ebXML alone for process interoperation between enterprise systems? We find that users will lack important implementation information because of representational deficiencies; due to ontological redundancy, the complexity of the specification is unnecessarily increased; and, users of the specification will have to bring in extra-model knowledge to understand constructs in the specification due to instances of ontological excess.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Minimal representations are known to have no redundant elements, and are therefore of great importance. Based on the notions of performance and size indices and measures for process systems, the paper proposes conditions for a process model being minimal in a set of functionally equivalent models with respect to a size norm. Generalized versions of known procedures to obtain minimal process models for a given modelling goal, model reduction based on sensitivity analysis and incremental model building are proposed and discussed. The notions and procedures are illustrated and compared on a simple example, that of a simple nonlinear fermentation process with different modelling goals and on a case study of a heat exchanger modelling. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE - To assess the performance of health systems using diabetes as a tracer condition. RESEARCH DESIGN AND METHODS - We generated a measure of case-fatality among young people with diabetes Using the mortalily-to-incidence ratio (M/I ratio) for 29 industrialized countries using published data on diabetes incidence and mortality. Standardized incidence rates for ages 0-14 years were extracted from the World Health Organization DiaMond Study for the period 1990-1994; data on death from diabetes for ages 0-39 years were obtained from the World Health Organization Mortality database and converted into age-standardized death rates for the period 1994-1998, using the European standard population. RESULTS - The MA ratio varied > 10-fold. These relative differences appear similar to those observed in cohort studies of mortality among young people with type I diabetes in five countries. A sensitivity analysis showed that using plausible assumptions about potential overestimation of diabetes as a cause of death and underestimation of incidence rates in the U.S. yields an M/I ratio that would still be twice as high as in the U.K. or Canada. CONCLUSIONS - The M/I ratio for diabetes provides a means of differentiating countries on quality of care for people with diabetes. It is solely an indicator of potential problems, a basis for Stimulating more detailed assessments of whether such problems exist, and what can be done to address them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple input multiple output (MIMO) wireless systems use multiple element antennas (MEAs) tit the transmitter (TX) and the receiver (RX) in order to offer improved information rates (capacity) over conventional single antenna systems in rich scattering environments. In this paper, an example of a simple MIMO system is considered in which both antennas and scattering objects is are formed by wire dipoles. Such it system can be analyzed in the strict electromagnetic (EM) sense and its capacity can be determined for varying array size, interelement spacing, and distributions of scatterers. The EM model of this MIMO system can be used to assess the validity of single- or double-bounce scattering models for mixed line of sight (LOS) and non-line of sight (NLOS) signal-propagation conditions. (c) 2006 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Thames Estuary, UK, and the Brisbane River, Australia, are comparable in size and catchment area. Both are representative of the large and growing number of the world's estuaries associated with major cities. Principle differences between the two systems relate to climate and human population pressures. In order to assess the potential phytotoxic impact of herbicide residues in the estuaries, surface waters were analysed with a PAM fluorometry-based bioassay that employs the photosynthetic efficiency (photosystem II quantum yield) of laboratory cultured microalgae, as an endpoint measure of phytotoxicity. In addition, surface waters were chemically analysed for a limited number of herbicides. Diuron atrazine and simazine were detected in both systems at comparable concentrations. In contrast, bioassay results revealed that whilst detected herbicides accounted for the observed phytotoxicity of Brisbane River extracts with great accuracy, they consistently explained only around 50% of the phytotoxicity induced by Thames Estuary extracts. Unaccounted for phytotoxicity in Thames surface waters is indicative of unidentified phytotoxins. The greatest phytotoxic response was measured at Charing Cross, Thames Estuary, and corresponded to a diuron equivalent concentration of 180 ng L-1. The study employs relative potencies (REP) of PSII impacting herbicides and demonstrates that chemical analysis alone is prone to omission of valuable information. Results of the study provide support for the incorporation of bioassays into routine monitoring programs where bioassay data may be used to predict and verify chemical contamination data, alert to unidentified compounds and provide the user with information regarding cumulative toxicity of complex mixtures. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple input multiple output (MIMO) wireless systems use multiple element antennas at the transmitter and receiver to offer improved capacity over conventional single antenna systems in a rich scattering environment. In this paper, the microwave perspective of operation of MIMO system is given. Following the new interpretation of operation, an electromagnetic model is introduced to assess the MIMO system transmission capacity. The proposed model is shown to provide good agreement with reported results in the literature.