999 resultados para FINGERPRINT DETECTION
Resumo:
Normal ageing is associated with characteristic changes in brain microstructure. Although in vivo neuroimaging captures spatial and temporal patterns of age-related changes of anatomy at the macroscopic scale, our knowledge of the underlying (patho)physiological processes at cellular and molecular levels is still limited. The aim of this study is to explore brain tissue properties in normal ageing using quantitative magnetic resonance imaging (MRI) alongside conventional morphological assessment. Using a whole-brain approach in a cohort of 26 adults, aged 18-85years, we performed voxel-based morphometric (VBM) analysis and voxel-based quantification (VBQ) of diffusion tensor, magnetization transfer (MT), R1, and R2* relaxation parameters. We found age-related reductions in cortical and subcortical grey matter volume paralleled by changes in fractional anisotropy (FA), mean diffusivity (MD), MT and R2*. The latter were regionally specific depending on their differential sensitivity to microscopic tissue properties. VBQ of white matter revealed distinct anatomical patterns of age-related change in microstructure. Widespread and profound reduction in MT contrasted with local FA decreases paralleled by MD increases. R1 reductions and R2* increases were observed to a smaller extent in overlapping occipito-parietal white matter regions. We interpret our findings, based on current biophysical models, as a fingerprint of age-dependent brain atrophy and underlying microstructural changes in myelin, iron deposits and water. The VBQ approach we present allows for systematic unbiased exploration of the interaction between imaging parameters and extends current methods for detection of neurodegenerative processes in the brain. The demonstrated parameter-specific distribution patterns offer insights into age-related brain structure changes in vivo and provide essential baseline data for studying disease against a background of healthy ageing.
Resumo:
Source: Description: pKM-19 is a 1.0 kb EcoRI human genomic fragment inserted in pUC13, that detects a Scrfl (CC/NGG) RFLP (1, 2). We report here the primer sequences suitable for the detection of this RFLP by PCR...
Resumo:
Fingerprint practitioners rely on level 3 features to make decisions in relation to the source of an unknown friction ridge skin impression. This research proposes to assess the strength of evidence associated with pores when shown in (dis)agreement between a mark and a reference print. Based upon an algorithm designed to automatically detect pores, a metric is defined in order to compare different impressions. From this metric, the weight of the findings is quantified using a likelihood ratio. The results obtained on four configurations and 54 donors show the significant contribution of the pore features and translate into statistical terms what latent fingerprint examiners have developed holistically through experience. The system provides LRs that are indicative of the true state under both the prosecution and the defense propositions. Not only such a system brings transparency regarding the weight to assign to such features, but also forces a discussion in relation to the risks of such a model to mislead.
Resumo:
Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.
Resumo:
Ammonia gas detection by pure and catalytically modified WO3 based gas sensor was analysed. The sensor response of pure WO3 to NH3 was not only rather low but also presented an abnormal behaviour, probably due to the unselective oxidation of ammonia to NOx. Copper and vanadium were introduced in different concentrations and the resulting material was annealed at different temperatures in order to improve the sensing properties for NH3 detection. The introduction of copper and vanadium as catalytic additives improved the response to NH3 and also eliminated the abnormal behaviour. Possible mechanisms of NH3 reaction over these materials are discussed. Sensor responses to other gases like NO2 or CO and the interference of humidity on ammonia detection were also analysed so as to choose the best sensing element.
Resumo:
Leakage detection is an important issue in many chemical sensing applications. Leakage detection hy thresholds suffers from important drawbacks when sensors have serious drifts or they are affected by cross-sensitivities. Here we present an adaptive method based in a Dynamic Principal Component Analysis that models the relationships between the sensors in the may. In normal conditions a certain variance distribution characterizes sensor signals. However, in the presence of a new source of variance the PCA decomposition changes drastically. In order to prevent the influence of sensor drifts the model is adaptive and it is calculated in a recursive manner with minimum computational effort. The behavior of this technique is studied with synthetic signals and with real signals arising by oil vapor leakages in an air compressor. Results clearly demonstrate the efficiency of the proposed method.
Resumo:
Contamination with arsenic is a recurring problem in both industrialized and developing countries. Drinking water supplies for large populations can have concentrations much higher than the permissible levels (for most European countries and the United States, 10 μg As per L; elsewhere, 50 μg As per L). Arsenic analysis requires high-end instruments, which are largely unavailable in developing countries. Bioassays based on genetically engineered bacteria have been proposed as suitable alternatives but such tests would profit from better standardization and direct incorporation into sensing devices. The goal of this work was to develop and test microfluidic devices in which bacterial bioreporters could be embedded, exposed and reporter signals detected, as a further step towards a complete miniaturized bacterial biosensor. The signal element in the biosensor is a nonpathogenic laboratory strain of Escherichia coli, which produces a variant of the green fluorescent protein after contact to arsenite and arsenate. E. coli bioreporter cells were encapsulated in agarose beads and incorporated into a microfluidic device where they were captured in 500 × 500 μm(2) cages and exposed to aqueous samples containing arsenic. Cell-beads frozen at -20 °C in the microfluidic chip retained inducibility for up to a month and arsenic samples with 10 or 50 μg L(-1) could be reproducibly discriminated from the blank. In the 0-50 μg L(-1) range and with an exposure time of 200 minutes, the rate of signal increase was linearly proportional to the arsenic concentration. The time needed to reliably and reproducibly detect a concentration of 50 μg L(-1) was 75-120 minutes, and 120-180 minutes for a concentration of 10 μg L(-1).
Resumo:
Paul Ehrlich's inspired concept of 'magic bullets' for the cure of diseases has been revitalized by recent advances in immunology1. In particular, the development of cell fusion technology allowing the production of monoclonal antibodies (Mabs) with exquisite specificities2 triggered new hopes that we may now have the perfect carrier molecules with which to deliver cytotoxic drugs3 or toxins4 to the hidden cancer cells. This article reviews data on one aspect of the magic bullet concept, the use of radiolabelled antibodies as tracers for tumour localization. It will also discuss the very recent clinical use of 131I-labelled Mabs against carcinoembryonic antigen (CEA)5 to detect carcinoma either by conventional external photoscanning or by single photon emission computerized tomography (SPELT). This alliance of the most modern tools from immunology (Mabs) and nuclear medicine (SPELT) appears promising as a way to improve the sensitivity of 'immunoscintigraphy'. However, this approach is not yet ready, for widespread clinical use.
Resumo:
The usefulness and limitations of the carcinoembryonic antigen (C.E.A.) radioimmunoassay for the evaluation of tumour resection and for the detection of tumour relapse were studied in patients with large-bowel carcinoma. The level of plasma-C.E.A. was determined before any treatment in a group of 101 patients with histologically proven adenocarcinoma of the colon and rectum. 71% of all patients and 63% of cases with localised tumour (Dukes A and B) had a preoperative C.E.A. value of 5 ng. per ml. or higher. This limit was reached by only 1 of 90 apparently healthy, non-smoking blood-donors. Among 45 patients for whom a complete tumour resection was reported, all patients except 5 showed a drop of C.E.A. to normal values after surgery. The 5 patients whose C.E.A. did not fall to below 5 ng. per ml. showed a subsequent rise in C.E.A. level and were all found later to have a tumour relapse. The results indicate that an incomplete drop of circulating C.E.A. level one month after surgery has a bad prognostic significance. 22 of these patients were followed up by repeated C.E.A. radioimmunoassay for several months after surgery. 8 showed a progressive increase in C.E.A. levels preceding clinical diagnosis of tumour relapse by two to ten months. 6 other patients showed a moderate increase in C.E.A. levels, suggesting a tumour relapse not yet clinically detectable. The remaining 8 patients showed no increase in C.E.A. level above 5 ng. per ml. and no clinical symptoms of relapse. The results demonstrate that relapses of colon and rectum carcinoma can be detected by increased C.E.A. levels months before the appearance of any clinical evidence.
Resumo:
Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.
Resumo:
The paracaspase MALT1 is a Cys-dependent, Arg-specific protease that plays an essential role in the activation and proliferation of lymphocytes during the immune response. Oncogenic activation of MALT1 is associated with the development of specific forms of B-cell lymphomas. Through specific cleavage of its substrates, MALT1 controls various aspects of lymphocyte activation, including the activation of transcriptional pathways, the stabilization of mRNAs, and an increase in cellular adhesion. In lymphocytes, the activity of MALT1 is tightly controlled by its inducible monoubiquitination, which promotes the dimerization of MALT1. Here, we describe both in vitro and in vivo assays that have been developed to assess MALT1 activity.
Resumo:
Short-TE MRS has been proposed recently as a method for the in vivo detection and quantification of γ-aminobutyric acid (GABA) in the human brain at 3 T. In this study, we investigated the accuracy and reproducibility of short-TE MRS measurements of GABA at 3 T using both simulations and experiments. LCModel analysis was performed on a large number of simulated spectra with known metabolite input concentrations. Simulated spectra were generated using a range of spectral linewidths and signal-to-noise ratios to investigate the effect of varying experimental conditions, and analyses were performed using two different baseline models to investigate the effect of an inaccurate baseline model on GABA quantification. The results of these analyses indicated that, under experimental conditions corresponding to those typically observed in the occipital cortex, GABA concentration estimates are reproducible (mean reproducibility error, <20%), even when an incorrect baseline model is used. However, simulations indicate that the accuracy of GABA concentration estimates depends strongly on the experimental conditions (linewidth and signal-to-noise ratio). In addition to simulations, in vivo GABA measurements were performed using both spectral editing and short-TE MRS in the occipital cortex of 14 healthy volunteers. Short-TE MRS measurements of GABA exhibited a significant positive correlation with edited GABA measurements (R = 0.58, p < 0.05), suggesting that short-TE measurements of GABA correspond well with measurements made using spectral editing techniques. Finally, within-session reproducibility was assessed in the same 14 subjects using four consecutive short-TE GABA measurements in the occipital cortex. Across all subjects, the average coefficient of variation of these four GABA measurements was 8.7 ± 4.9%. This study demonstrates that, under some experimental conditions, short-TE MRS can be employed for the reproducible detection of GABA at 3 T, but that the technique should be used with caution, as the results are dependent on the experimental conditions. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
This guide is intended to serve as the fi rst step in your journey toward understanding your child’s hearing loss and the resources available for your child and your family. Research provides clear evidence that if a child with hearing loss is to succeed in both language and educational development, the involvement of parents is crucial. This guide will equip you with the basic knowledge and resources you need to navigate Iowa’s service system. Here you will find: • information about the professionals who will work with your child • information about family support • your child’s education and communication options • your rights and responsibilities as the parent of child who is deaf or hard of hearing • links to other important resources • a glossary of new words you may encounter
Resumo:
This guide is intended to serve as the fi rst step in your journey toward understanding your child’s hearing loss and the resources available for your child and your family. Research provides clear evidence that if a child with hearing loss is to succeed in both language and educational development, the involvement of parents is crucial. This guide will equip you with the basic knowledge and resources you need to navigate Iowa’s service system. Here you will find: • information about the professionals who will work with your child • information about family support • your child’s education and communication options • your rights and responsibilities as the parent of child who is deaf or hard of hearing • links to other important resources • a glossary of new words you may encounter Esta guía tiene por objeto ayudarle a dar el primer paso para comprender la pérdida auditiva de su hijo/a y los recursos disponibles para él/ella y su familia. Las investigaciones demuestran claramente que la participación de los padres es fundamental para que los niños con pérdida auditiva tengan éxito tanto en su desarrollo lingüístico como educacional. Esta guía le entregará los conocimientos y recursos básicos que necesitará para navegar por el sistema de servicios de Iowa. En esta guía encontrará: • información sobre los profesionales que trabajarán con su hijo/a • información sobre apoyo familiar • opciones de educación y comunicación de su hijo/a • sus derechos y responsabilidades como padre o madre de un niño con sordera o con difi cultades auditivas • vínculos a otros recursos importantes • un glosario de nuevas palabras que necesita conocer
Resumo:
PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.