950 resultados para ENERGY-CONSUMPTION PERMANENT


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis focuses on using photovoltaic produced electricity to power air conditioners in a tropical climate. The study takes place in Surabaya, Indonesia at two different locations the classroom, located at the UBAYA campus and the home office, 10 km away. Indonesia has an average solar irradiation of about 4.8 kWh/m²/day (PWC Indonesia, 2013) which is for ideal conditions for these tests. At the home office, tests were conducted on different photovoltaic systems. A series of measuring devices recorded the performance of the 800 W PV system and the consumption of the 1.35 kW air conditioner (cooling capacity). To have an off grid system many of the components need to be oversized. The inverter has to be oversized to meet the startup load of the air conditioner, which can be 3 to 8 times the operating power (Rozenblat, 2013). High energy consumption of the air conditioner would require a large battery storage to provide one day of autonomy. The PV systems output must at least match the consumption of the air conditioner. A grid connect system provides a much better solution with the 800 W PV system providing 80 % of the 3.5 kWh load of the air conditioner, the other 20 % coming from the grid during periods of low irradiation. In this system the startup load is provided by the grid so the inverter does not need to be oversized. With the grid-connected system, the PV panel’s production does not need to match the consumption of the air conditioner, although a smaller PV array will mean a smaller percentage of the load will be covered by PV. Using the results from the home office tests and results from measurements made in the classroom. Two different PV systems (8 kW and 12 kW) were simulated to power both the current air conditioners (COP 2.78) and new air conditioners (COP 4.0). The payback period of the systems can vary greatly depending on if a feed in tariff is awarded or not. If the feed in tariff is awarded the best system is the 12 kW system, with a payback period of 4.3 years and a levelized cost of energy at -3,334 IDR/kWh. If the feed in tariff is not granted then the 8 kW system is the best choice with a lower payback period and lower levelized cost of energy than the 12 kW system under the same conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions.   The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and indentify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered.   The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20 % without sacrificing ventilation efficiency or thermal comfort.   Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present thesis focuses on characterisation of microstructure and the resulting mechanical and tribological properties of CVD and PVD coatings used in metal cutting applications. These thin and hard coatings are designed to improve the tribological performance of cutting tools which in metal cutting operations may result in improved cutting performance, lower energy consumption, lower production costs and lower impact on the environment.  In order to increase the understanding of the tribological behaviour of the coating systems a number of friction and wear tests have been performed and evaluated by post-test microscopy and surface analysis. Much of the work has focused on coating cohesive and adhesive strength, surface fatigue resistance, abrasive wear resistance and friction and wear behaviour under sliding contact and metal cutting conditions. The results show that the CVD deposition of accurate crystallographic phases, e.g. α-Al2O3 rather than κ-Al2O3, textures and multilayer structures can increase the wear resistance of Al2O3. However, the characteristics of the interfaces, e.g. topography as well as interfacial porosity, have a strong impact on coating adhesion and consequently on the resulting properties.  Through the deposition of well designed bonding and template layer structures the above problems may be eliminated. Also, the presence of macro-particles in PVD coatings may have a significant impact on the interfacial adhesive strength, increasing the tendency to coating spalling and lowering the surface fatigue resistance, as well as increasing the friction in sliding contacts. Finally, the CVD-Al2O3 coating topography influences the contact conditions in sliding as well as in metal cutting. In summary, the work illuminates the importance of understanding the relationships between deposition process parameters, composition and microstructure, resulting properties and tribological performance of CVD and PVD coatings and how this knowledge can be used to develop the coating materials of tomorrow.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Forest nurseries are essential for producing good quality seedlings, thus being a key element in the reforestation process. With increasing climate change awareness, nursery managers are looking for new tools that can help reduce the effects of their operations on the environment. The ZEPHYR project, funded by the European Commission under the Seventh Framework Programme (FP7), has the objective of finding new alternatives for nurseries by developing innovative zero-impact technologies for forest plant production. Due to their direct relationship to the energy consumption of the nurseries, one of the main elements addressed are the grow lights used for the pre-cultivation. New LED luminaires with a light spectrum tailored to the seedlings’ needs are being studied and compared against the traditional fluorescent lamps. Seedlings of Picea abies and Pinus sylvestris were grown under five different light spectra (one fluorescent and 4 LED) during 5 weeks with a photoperiod of 16 hours at 100 μmol∙m-2∙s-1 and 60% humidity. In order to evaluate if these seedlings were able cope with real field stress conditions, a forest field trial was also designed. The terrain chosen was a typical planting site in mid-Sweden after clear-cutting. Two vegetation periods after the outplanting, the seedlings that were pre-cultivated under the LED lamps have performed at least as well as those that were grown under fluorescent lights. These results show that there is a good  potential for lightning substitution in forestry nurseries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a methodology to identify robust operating regions through the selection of controllable factory variables, using discrete event simulation. A casting plant melt facility was used as an industrial test bed to develop these techniques. A robust system design was determined by response surface analysis of key production parameters. Furthermore, robust operating policies that maximise throughput, while minimizing work-in-progress and thus energy consumption were identified.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Air drag on yarn and package surfaces affects yarn tension, which in turn affects energy consumption and ends-down in ring spinning. This study investigated the effects of yarn hairiness on air drag in ring spinning. Theoretical models of skin friction coefficient on the surface of rotating yarn packages were developed. The predicted results were verified with experimental data obtained from cotton and wool yarns. The results show that hairiness increases the air drag by about one-quarter and one-third for the rotating cotton and wool yarn packages, respectively. In addition, yarn hairiness increases the air drag by about one-tenth on a ballooning cotton yarn.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The rapid economic success achieved by the developing countries in general, and India and China in particular, has brought the issue of climate change, which is a spin-off of development, to the fore. Economic growth is essential for the eradication of poverty and generation of wealth. However, it drives energy consumption and demand for energy which, in turn, produces toxic gases like carbon dioxide (CO2 ). Thus, the price of economic growth is climate change. The paradox lies in the fact that when economic growth is the only solution to poverty, the resultant climate change (characterized by emission of greenhouse gases) also affects the poor greatly. In this context, it is observed that while traditionally the developed countries were charged with polluting the environment globally, now the developing countries have overtaken their counterparts as polluters. The developing countries have emerged, over the years, as the agents responsible for growing pollution in the world, though they are also the victims, as most of the poor people belong to the developing countries. The author explores the nexus between climate change and development in the context of the economic growth of the developing countries and its impact on them.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A practical experiment is described which was used to help university students increase their understanding of the effect of construction methods and window design on passive solar heating and electrical heating. A number of one tenth scale model rooms were constructed by students and sited out-of-doors in the late autumn. The models were fabricated to mimic available commercial construction techniques with careful consideration being given to window size and placement for solar access. Each model had a thermostatically controlled electric heating element. The temperatures and electricity use of the models were recorded using data-loggers over a two week period. The performances of the models based on energy consumption and internal temperature were compared with each other and with predictions based upon thermal mass and R-values. Examples of questions used by students to facilitate this process are included. The effect of scaling on thermal properties was analysed using Buckingham’s p-theorem.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Built Environment Research Group (BERG) at the School of Architecture and Building at Deakin University is involved in the monitoring of building energy consumption, lighting and acoustic levels, as well as material and thermal performance. Such measurements have taken place in several buildings over the last few years. This has been the result of a deliberate policy of BERG to initiate a process that completes the loop of design, prediction, monitoring, verification, teaching, then back to design again. This paper presents a summary of some projects that have involved building monitoring. We have established a methodology for measuring buildings which will be discussed, as well as the reasoning behind our desire to monitor buildings in general. The paper will present a summary of the results of measurement acquired to date (energy consumption, schedules, operation, etc.) and the lessons that have been learned from this monitoring program.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 2100 m2 (GFA) two-storey rammed earth building was built on the Thurgoona campus of Charles Sturt University in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes a thermal model of one of the second-storey offices on the west-end of the building. The simulation software, TRNSYS, has been used to predict office temperatures and comparisons are made between these and measurements made over a typical week in summer. Reasonable agreement has been achieved under most conditions. The model has been used to investigate key building parameters and strategies, including night flushing, to improve the thermal comfort in the office.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Energy efficient office buildings are intended to provide a comfortable and healthy environment for their occupants as well as reducing the energy consumption of the building. They are often designed as "showcase" buildings illustrating the potential for savings through some innovative design technology. But do such buildings actually deliver the desired energy savings and satisfactory comfort conditions for occupants? Measurements of a "green" University campus building in Victoria, Australia, designed with an innovative fabric energy storage system, demonstrate that the ventilation system is not providing acceptable indoor air quality conditions. The design strategies used to reduce energy consumption have had negative consequences on the air quality of the building. Insufficient fresh air is being drawn into the building leading to an excessive build up of carbon dioxide. It is recommended that monitoring systems need to use a wider range of measurements than temperature alone to guarantee good quality indoor air and working conditions and that commissioning of buildings should include adequate monitoring of the operational performance of the building. Designers need to be made aware of the potential consequences of their decisions when attempting innovative energy-efficient designs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we examine the problem of finding an optimal position for a receiver node in a single-hop sensor network. The basic idea is to minimize the network energy consumption according to a particular network cost function. Our contribution is to simply show the effect of signal path loss rates and sensor weighting on the optimal receiver position.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The literature over the past 25 years indicates that there has been a continued interest in using passive and active solar technologies to reduce the conventional energy required to maintain water temperatures in small recirculation aquaculture systems. Although all of the experimental systems reviewed report favourable results, there is little information available to guide system designers. This paper describes the use of a simulation model to predict the annual conventional energy consumption of a 10.6 m3 RAS enclosed in a double layer polyethylene greenhouse in two different climates. The water was maintained at 22.5 °C and the recirculation rate was 10% of tank volume per day. Simple unglazed solar collectors have also been combined with the greenhouse to further reduce energy consumption. The effect of increasing collector area on the solar fraction and utilization of useful energy was predicted. Finally, the model was used to investigate the relationship between the occurrence of condensation on the inner cover, ventilation rates and energy use. It was found that in a hot dry climate, the greenhouse alone was sufficient to reduce the conventional energy requirements by 87%; while in the cooler temperate climate reductions of 66% were possible. When solar collectors were added to the system, conventional energy requirements were reduced further and depended on the area of collector used. For example, in the temperate climate location, conventional energy requirements were reduced to 23% of a RAS enclosed in a non-solar building when 26 m2 of solar collector inclined at the optimum angle for winter energy collection were used. Although condensation could be successfully reduced by ventilation of the greenhouse, this increased conventional energy requirements because the potential for evaporation was increased. Covering the tanks at night was found to be a more effective strategy because it reduced condensation and conventional energy use simultaneously.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Air-drag on a ballooning yarn and balloon shape affect the yarn tension and ends-down (yarn breakage), which in turn affects energy consumption and yarn productivity in ring spinning. In this article, a mathematical model of yarn ballooning motion in ring spinning is established. The model can be used to generate balloon shape and predict tension in the ballooning yarn under given spinning conditions. Yarn tension was measured using a computer data acquisition system and the balloon shapes were captured using a digital camera with video capability during the experiments using cotton and wool yarns at various balloon-heights and with varying yarn-length in the balloon. The air-drag coefficients on ballooning cotton and wool yarns in ring spinning were estimated by making a “best fit” between the theoretical and experimental turning points. The theoretical results were verified with experimental data. The effects of air-drag and balloon shape on yarn tension are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Maintaining QoS (quality of service) guaranteed communication links, and improving the energy consumption; are two aspects that received a significant consideration in the modern wireless sensor network research. This paper formulates a transmission power control problem which satisfies both considerations mentioned above. Moreover, a class of functions for an iterative controller was introduced and analyzed for its convergence. The experimental evaluation of the controller justifies the theoretical assertions as well as the applicability of the control scheme in wireless nodes with minimum measurement capabilities.