1000 resultados para Dosimetric applications
Resumo:
chemical Sciences and Technology Division, National Institute for Interdisciplinary Science and Technology, CSIR
Resumo:
The thesis covers a systematic investigation on the synthesis of silica aerogels and microspheres with tailored porosity, at ambient conditions by varying the experimental parameters as well as using organic templates. Organically modified silica-gelatin and silica-chitosan hybrids were developed for the first time using alkylalkoxysilanes such as MTMS and VTMS. Application of novel silica-biopolymer antiwetting coatings on different substrates such as glass, leather and textile is also demonstrated in the thesis.
Resumo:
Hydroxyapatite (HAp, Ca10(PO4)6(OH)2) bioceramic and chitosan (poly [( -1-4) D-glucosamine]) biopolymer show good biocompatibility in vivo. They have biological origin and show excellent interactions with microwave. Microwave study of HAp made using different drying techniques and their composites with chitosan in the ISM band is presented. Pastes are made using HAp and chitosan with different ratios of mixing. The dielectric properties of this composites match with that of human fat, collagen tissues. Some of the compositions exhibit dielectric property close to that of natural bone. This makes them more biocompatible and better substitutes for natural bone. Thus composite bioceramics can be considered as phantom model constituents for imaging purposes. Their dielectric properties prove that they are biocompatible.
Resumo:
Advent of lasers together with the advancement in fiber optics technology has revolutionized the sensor technology. Advancement in the telemetric applications of optical fiber based measurements is an added bonus. The present thesis describes variety of fiber based sensors using techniques like micro bending, long period grating and evanescent waves. Sensors to measure various physical and chemical parameters are described in this thesis.
Resumo:
Analog-to digital Converters (ADC) have an important impact on the overall performance of signal processing system. This research is to explore efficient techniques for the design of sigma-delta ADC,specially for multi-standard wireless tranceivers. In particular, the aim is to develop novel models and algorithms to address this problem and to implement software tools which are avle to assist the designer's decisions in the system-level exploration phase. To this end, this thesis presents a framework of techniques to design sigma-delta analog to digital converters.A2-2-2 reconfigurable sigma-delta modulator is proposed which can meet the design specifications of the three wireless communication standards namely GSM,WCDMA and WLAN. A sigma-delta modulator design tool is developed using the Graphical User Interface Development Environment (GUIDE) In MATLAB.Genetic Algorithm(GA) based search method is introduced to find the optimum value of the scaling coefficients and to maximize the dynamic range in a sigma-delta modulator.
Resumo:
Breast cancer is the most common non - skin malignancy in women and a leading cause of female morality. A potentially important strategy for reducing this menace is the detection at an early stage . The invention of non-invasive and non-ionizing microwave technique, to reveal the internal structure of biological objects was a break through in the field of medical diagnostics. Electrical properties of biological tissues and their interaction with electromagmetic waves have direct impact on human life. This thesis focuses on theoretical and experimental investigations of active microwave imaging techniques for breast cancer detection.
Resumo:
Department of Physics, Cochin University of Science and Technology
Resumo:
Department of Physics, Cochin University of Science and Technology
Resumo:
In recent years, there is a visible trend for products/services which demand seamless integration of cellular networks, WLANs and WPANs. This is a strong indication for the inclusion of high speed short range wireless technology in future applications. In this context UWB radio has a significant role to play as an extension/complement to existing cellular/access technology. In the present work, we have investigated two major types of wide band planar antennas: Monopole and Slot. Four novel compact broadband antennas, suitable for poratble applications, are designed and characterized, namely 1. Elliptical monopole 2. Inverted cone monopole 3. Koch fractal slot 4. Wide band slot The performance of these designs have been studied using standard simulation tools used in industry/academia and they have been experimentally verified. Antenna design guidelines are also deduced by accounting the resonances in each structure. In addition to having compact sized, high efficiency and broad bandwidth antennas, one of the major criterion in the design of impulse-UWB systems have been the transmission of narrow band pulses with minimum distortion. The key challenge is not only to design a broad band antenna with constant and stable gain but to maintain a flat group delay or linear phase response in the frequency domain or excellent transient response in time domain. One of the major contributions of the thesis lies in the analysis of the frequency and time-domain response of the designed UWB antennas to confirm their suitability for portable pulsed-UWB systems. Techniques to avoid narrowband interference by engraving narrow slot resonators on the antenna is also proposed and their effect on a nano-second pulse have been investigated.
Resumo:
School of environmental studies, Cochin University of Science and Technology
Resumo:
Plasticized poly(vinyl chloride) (pPVC), although a major player in the medical field, is at present facing lot of criticism due to some of its limitations like the leaching out of the toxic plasticizer, di ethylhexyl phthalate (DEHP) to the medium and the emission of an environmental pollutant,dioxin gas,at the time of the post use disposal of PVC Products by incineration. Due to these reasons, efforts are on to reduce the use of pPVC considerably in the medical field and to find viable alternative materials. The present study has been undertaken in this context to find a suitable material for the manufacture of medical aids in place of pPVC. The main focus of this study has been to find out a non-DEHP material as plasticizer for pPVC and another suitable material for the complete repalcement of pPVC for blood/ blood component storage applications.Two approaches have been undertaken for this purpose-(1)the controversial plasticizer, DEHP has been partially replaced by polymeric plasticizers(2) an alternative material, namely, metallocene polyolefin (mPO) has been used and suitably modified to match the properties of flexible PVC used for blood and blood component storage applications.
Resumo:
One of the fastest expanding areas of computer exploitation is in embedded systems, whose prime function is not that of computing, but which nevertheless require information processing in order to carry out their prime function. Advances in hardware technology have made multi microprocessor systems a viable alternative to uniprocessor systems in many embedded application areas. This thesis reports the results of investigations carried out on multi microprocessors oriented towards embedded applications, with a view to enhancing throughput and reliability. An ideal controller for multiprocessor operation is developed which would smoothen sharing of routines and enable more powerful and efficient code I data interchange. Results of performance evaluation are appended.A typical application scenario is presented, which calls for classifying tasks based on characteristic features that were identified. The different classes are introduced along with a partitioned storage scheme. Theoretical analysis is also given. A review of schemes available for reducing disc access time is carried out and a new scheme presented. This is found to speed up data base transactions in embedded systems. The significance of software maintenance and adaptation in such applications is highlighted. A novel scheme of prov1d1ng a maintenance folio to system firmware is presented, alongwith experimental results. Processing reliability can be enhanced if facility exists to check if a particular instruction in a stream is appropriate. Likelihood of occurrence of a particular instruction would be more prudent if number of instructions in the set is less. A new organisation is derived to form the basement for further work. Some early results that would help steer the course of the work are presented.
Resumo:
Department of Physics, Cochin University of Science and Technology
Resumo:
Photoconductivity (PC) processes may be the most suitable technique for obtaining information about the states in the gap. It finds applications in photovoItaics, photo detection and radiation measurements. The main task in the area of photovoltaics, is to increase the efficiency of the device and also to develop new materials with good optoelectronic properties useful for energy conversion, keeping the idea of cost effectiveness. Photoconduction includes generation and recombination of carriers and their transport to the electrodes. So thermal relaxation process, charge carrier statistics, effects of electrodes and several mechanisms of recombination are involved in photoconductivity.A major effect of trapping is to make the experimentally observed decay time of photocurrent, longer than carrier lifetime. If no trapping centers are present, then observed photocurrent will decay in the same way as the density of free carriers and the observed decay time will be equal to carrier lifetime. If the density of free carriers is much less than density of trapped carriers, the entire decay of photocurrent is effectively dominated by the rate of trap emptying rather than by the rate of recombination.In the present study, the decay time of carriers was measured using photoconductive decay (PCD) technique. For the measurements, the film was loaded in a liquid Helium cryostat and the temperature was controlled using Lakshore Auto tuning temperature controller (Model 321). White light was used to illuminate the required area of the sample. Heat radiation from the light source was avoided by passing the light beam through a water filter. The decay current. after switching off the illumination. was measured using a Kiethely 2000 multi meter. Sets of PCD measurements were taken varying sample temperature, sample preparation temperature, thickness of the film, partial pressure of Oxygen and concentration of a particular element in a compound. Decay times were calculated using the rate window technique, which is a decay sampling technique particularly suited to computerized analysis. For PCD curves with two well-defined regions, two windows were chosen, one at the fast decay region and the other at the slow decay region. The curves in a particular window were exponentially fitted using Microsoft Excel 2000 programme. These decay times were plotted against sample temperature and sample preparation temperature to study the effect of various defects in the film. These studies were done in order to optimize conditions of preparation technique so as to get good photosensitive samples. useful for photovoltaic applications.Materials selected for the study were CdS, In2Se3, CuIn2Se3 and CuInS2• Photoconductivity studies done on these samples are organised in six chapters including introduction and conclusion.