980 resultados para Dimensional analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We show results from an analysis performed to test the resolving power of a two-dimensional χ2 method proposed previously when applied to the case of kaon interferometry, where no significant contribution from long-lived resonances is expected. For that purpose, use is made of the preliminary E859 K+K+ interferometry data from Si+Au collisions at 14.6/4 GeV/c. Although less sensitivity is achieved in the present case, this analysis seems to favor scenarios with no resonance formation at the AGS energy range. The possible compatibility of data with zero decoupling proper time interval, conjectured by the three-dimensional experimental analysis, is also investigated and is ruled out when considering more realistic dynamical models with expanding sources. Furthermore, these results strongly emphasize that the static Gaussian parametrization cannot be trusted under more realistic conditions, leading to a distorted or even wrong interpretation of the source parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes two solutions for systematic measurement of surface elevation that can be used for both profile and surface reconstructions for quantitative fractography case studies. The first one is developed under Khoros graphical interface environment. It consists of an adaption of the almost classical area matching algorithm, that is based on cross-correlation operations, to the well-known method of parallax measurements from stereo pairs. A normalization function was created to avoid false cross-correlation peaks, driving to the true window best matching solution at each region analyzed on both stereo projections. Some limitations to the use of scanning electron microscopy and the types of surface patterns are also discussed. The second algorithm is based on a spatial correlation function. This solution is implemented under the NIH Image macro programming, combining a good representation for low contrast regions and many improvements on overall user interface and performance. Its advantages and limitations are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this letter we discuss the (2 + 1)-dimensional generalization of the Camassa-Holm equation. We require that this generalization be, at the same time, integrable and physically derivable under the same asymptotic analysis as the original Camassa-Holm equation. First, we find the equation in a perturbative calculation in shallow-water theory. We then demonstrate its integrability and find several particular solutions describing (2 + 1) solitary-wave like solutions. © 1999 Published by Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Group theoretical-based techniques and fundamental results from number theory are used in order to allow for the construction of exact projectors in finite-dimensional spaces. These operators are shown to make use only of discrete variables, which play the role of discrete generator coordinates, and their application in the number symmetry restoration is carried out in a nuclear BCS wave function which explicitly violates that symmetry. © 1999 Published by Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this note we describe the most general coupling of abelian vector and tensor multiplets to six-dimensional (1,0) supergravity. As was recently pointed out, it is of interest to consider more general Chern-Simons couplings to abelian vectors of the type H(r) = dB(r) - 1/2 c(rab)AadAb, with c(r) matrices that may not be simultaneously diagonalized. We show that these couplings can be related to Green-Schwarz terms of the form B(r)c(r)/abFaFb, and how the complete local Lagrangian, that embodies factorized gauge and supersymmetry anomalies (to be disposed of by fermion loops) is uniquely determined by Wess-Zumino consistency conditions, aside from an arbitrary quartic coupling for the gauginos. (C) 2000 Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the theoretical and experimental results for oxide thin film growth on titanium films previously deposited over glass substrate. Ti films of thickness 0.1 μm were heated by Nd:YAG laser pulses in air. The oxide tracks were created by moving the samples with a constant speed of 2 mm/s, under the laser action. The micro-topographic analysis of the tracks was performed by a microprofiler. The results taken along a straight line perpendicular to the track axis revealed a Gaussian profile that closely matches the laser's spatial mode profile, indicating the effectiveness of the surface temperature gradient on the film's growth process. The sample's micro-Raman spectra showed two strong bands at 447 and 612 cm -1 associated with the TiO 2 structure. This is a strong indication that thermo-oxidation reactions took place at the Ti film surface that reached an estimated temperature of 1160 K just due to the action of the first pulse. The results obtained from the numerical integration of the analytical equation which describes the oxidation rate (Wagner equation) are in agreement with the experimental data for film thickness in the high laser intensity region. This shows the partial accuracy of the one-dimensional model adopted for describing the film growth rate. © 2001 Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. Purpose. The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. Material and methods. The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37°C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55°C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71°C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37°C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). Results. All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). Conclusion. Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550. Copyright © 2002 by The Editorial Council of The Journal of Prosthetic Dentistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ablation is a thermal protection process with several applications in engineering, mainly in the field of airspace industry. The use of conventional materials must be quite restricted, because they would suffer catastrophic flaws due to thermal degradation of their structures. However, the same materials can be quite suitable once being protected by well-known ablative materials. The process that involves the ablative phenomena is complex, could involve the whole or partial loss of material that is sacrificed for absorption of energy. The analysis of the ablative process in a blunt body with revolution geometry will be made on the stagnation point area that can be simplified as a one-dimensional plane plate problem, hi this work the Generalized Integral Transform Technique (GITT) is employed for the solution of the non-linear system of coupled partial differential equations that model the phenomena. The solution of the problem is obtained by transforming the non-linear partial differential equation system to a system of coupled first order ordinary differential equations and then solving it by using well-established numerical routines. The results of interest such as the temperature field, the depth and the rate of removal of the ablative material are presented and compared with those ones available in the open literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, we compared six different solubilization buffers and optimized two-dimensional electrophoresis (2-DE) conditions for human lymph node proteins. In addition, we developed a simple protocol for 2-D gel storage. Efficient solubilization was obtained with lysis buffers containing (a) 8 M urea, 4% CHAPS (3-[(3-cholamidopropyl) dimethylammonio]-1-propanesulfonate), 40 mM Tris base, 65 mM DTT (dithiothreitol) and 0.2% carrier ampholytes; (b) 5 M urea, 2 M thiourea, 2% CHAPS, 2% SB 3-10 (N-decyl-N,N-dimethyl-3-ammonio-1-propanesulfonate), 40 mM Tris base, 65 mM DTT and 0.2% carrier ampholytes or (c) 7 M urea, 2 M thiourea, 4% CHAPS, 65 mM DTT and 0.2% carrier ampholytes. The optimal protocol for isoelectric focusing (IEF) was accumulated voltage of 16,500 Vh and 0.6% DTT in the rehydration solution. In the experiments conducted for the sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), best results were obtained with a doubled concentration (50 mM Tris, 384 mM glycine, 0.2% SDS) of the SDS electrophoresis buffer in the cathodic reservoir as compared to the concentration in the anodic reservoir (25 mM Tris, 192 mM glycine, 0.1% SDS). Among the five protocols tested for gel storing, success was attained when the gels were stored in plastic bags with 50% glycerol. This is the first report describing the successful solubilization and 2D-electrophoresis of proteins from human lymph node tissue and a 2-D gel storage protocol for easy gel handling before mass spectrometry (MS) analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the dimensional stability and detail reproduction of two silicones used for facial prosthesis, under the influence of chemical disinfection and storage time. Twenty-eight test specimens were obtained, half made of Silastic MDX 4-4210 silicone, and the other half of Silastic 732 RTV silicone. The test specimens were divided into 4 groups: Silastic 732 RTV and Silastic MDX 4-4210, with disinfection 3 times a week with Efferdent and without disinfection. Dimensional change was analyzed using an electronic comparison microscope and detail reproduction was observed under a stereo microscope, immediately and 2 months after the test specimens were made. Once the results were obtained, an analisis of variance (ANOVA) was applied, followed by the Tukey's Test with 1% confidence. The storage time factor had a statistical influence on dimensional stability: Silastic MDX 4-4210 had less contraction than Silastic 732 RTV. Chemical disinfection did not significantly alter the dimensional stability of the materials used. Regarding detail reproduction, no alteration of values was observed in any of the materials analyzed, regardless of storage period or disinfection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dynamical system investigated in this work is a nonlinear flexible beam-like structure in slewing motion. Non-dimensional and perturbed governing equations of motion are presented. The analytical solution for the linear part of these perturbed equations for ideal and for non-ideal cases are obtained. This solution is necessary for the investigation of the complete weak nonlinear problem where all nonlinearities are small perturbations around a linear known solution. This investigation shall help the analyst in the modelling of dynamical systems with structure- actuator interactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Acidithiobacillus ferrooxidans periplasmic space is known to have proteins involved in the respiratory chains. There are no reports about the expression of the periplasmic proteins in A. ferrooxidans cells attached to chalcopyrite. In this preliminary work, it was compared the periplasmic protein profiles of A. ferrooxidans planktonic and attached cells after exposure to chalcopyrite for 2 hours. The bacterial response to chalcopyrite was investigated by a proteomic approach (two- dimensional gel electrophoresis and mass spectrometry). Four proteins differentially expressed between planktonic and attached cells after exposure to chalcopyrite were identified. Two of these proteins, repressed in chalcopyrite- attached cells, were both identified as superoxide dismutase, whereas the single strand binding protein (SSB) and the PspA/IM30 protein were induced. These results showed that A. ferrooxidans chalcopyrite- attached and planktonic cells show differential expression of the periplasmic proteins and that a proteomic approach can provide a valuable tool to detect proteins related to the A. ferrooxidans response to attachment to the mineral substrates. © (2009) Trans Tech Publications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Cladocera assemblages in two cascade reservoirs located in the Paranapanema River in Brazil were studied during two consecutive years. Upstream Chavantes Reservoir is an accumulation system, with a long water retention time, high depth and oligo-mesotrophic status. The downstream Salto Grande Reservoir is a small, run-of-river reservoir, with a short water retention time, shallow depth and meso-eutrophic status. The goal of this study was to determine the inter- and intra-reservoir limnological differences with emphasis on the Cladocerans assemblages. The following questions were posed: (i) what are the seasonal dynamics of the reservoir spatial structures; (ii) how dynamics, seasonally, is the reservoirs spatial structure; and (iii) are the reservoir independent systems? A total of 43 Cladoceran species were identified in this study. Ceriodaphnia silvestrii was the most abundant and frequent species found in Chavantes Reservoir, while C. cornuta was most abundant and frequent in Salto Grande Reservoir. The Cladoceran species richness differed significantly among sampling sites for both reservoirs. In terms of abundance, there was a significant variation among sampling sites and periods for both reservoirs. A cluster analysis indicated a higher similarity among the deeper compartments, and the intermediate river-reservoir zones was grouped with the riverine sampling sites. For the smaller Salto Grande Reservoir, the entrance of a middle size tributary causes major changes in the system. A distinct environment was observed in the river mouth zone of another small tributary, representing a shallow environment with aquatic macrophyte stands. A canonical correlation analysis between environmental variables and Cladoceran abundance explained 75% of the data variability, and a complementary factorial analysis explained 65% of the variability. The spatial compartmentalization of the reservoirs, as well as the particular characteristics of the two study reservoirs, directly influenced the structure of the Cladoceran assemblages. The conditions of the lacustrine (dam) zone of the larger Chavantes Reservoir were reflected in the upstream zone of the smaller downstream Salto Grande Reservoir, highlighting the importance of plankton exportation in reservoir cascade systems. The comparative spatial-temporal analysis indicated conspicuous differences between the two reservoirs, reinforcing the necessity of considering tropical/subtropical reservoirs as complex, multi-compartmental water systems. © 2010 The Authors. Journal compilation © 2010 Blackwell Publishing Asia Pty Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a comparative analysis between the experimental characterization and the numerical simulation results for a three-dimensional FCC photonic crystal (PhC) based on a self-assembly synthesis of monodispersive latex spheres. Specifically, experimental optical characterization, by means of reflectance measurements under variable angles over the lattice plane family [1,1, 1], are compared to theoretical calculations based on the Finite Di®erence Time Domain (FDTD) method, in order to investigate the correlation between theoretical predictions and experimental data. The goal is to highlight the influence of crystal defects on the achieved performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the dimensional alterations and the solubility of two experimental endodontic sealers based on Copaifera multijuga oil-resin (Biosealer) and castor oil bean cement (Poliquil), maintained in different storage solutions. Twenty specimens (3 mm diameter and 2 mm height) of each sealer were assigned to 2 groups (n=10) according to the storage solution: simulated tissue fluid (STF) or distilled water (DW). The specimens were stored in these solutions during 90 days, being removed every 30 days for weighting. The solutions were renewed every 15 days. The results were subjected to statistical analysis by Dunn's and Mann-Whitney tests (α=0.05). The solubility of Poliquil was higher in STF (38.4 ± 36.0) than in DW (28.4 ± 15.0), while Biosealer showed higher solubility in DW (34.61 ± 6.0) than in STF (18.59 ± 8.0). The storage solution influenced the behavior of sealers in relation to the weight variation (p=0.0001). Poliquil presented higher variation of weight independent of the solution (p=0.239). Biosealer also presented higher variation of weight regardless of the solution (p=0.0001). The solubility of Biosealer was different from that of Poliquil, but both sealers showed low solubility in STF. Under the tested conditions, neither of the materials were according to the ADA'S specification.