942 resultados para Designing control system


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Definitions and perceptions of the role and styles of risk management, and performance management/strategic control systems have evolved over time, but it can be argued that risk management is primarily concerned with ensuring the achievement of strategic objectives. This paper shows the extent of overlap between a broad-based view of risk management, namely Enterprise Risk Management (ERM), and the balanced scorecard, which is a widely used strategic control system. A case study of one of the UK's largest retailers, Tesco plc, is used to show how ERM can be introduced as part of an existing strategic control system. The case demonstrates that, despite some differences in lines of communications, the strategic controls and risk controls can be used to achieve a common objective. Adoption of such an integrated approach, however, has implications for the profile of risk and the overall risk culture within an organisation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Evidence exists for an additional inhibitory accommodative control system mediated by the sympathetic branch of the autonomic nervous system (ANS). This work aims to show the relative prevalence of sympathetic inhibition in young emmetropic and myopic adults, and to evaluate the effect of sympathetic facility on accommodative and oculomotor function. Methods: Profiling of ciliary muscle innervation was carried out in 58 young adult subjects (30 emmetropes, 14 early onset myopes, 14 late onset myopes) by examining post-task open-loop accommodation responses, recorded continuously by a modified open-view infrared optometer. Measurements of amplitude of accommodation, tonic accommodation, accommodative lag at near, AC/A ratio, and heterophoria at distance and near were made to establish a profile of oculomotor function. Results: Evidence of sympathetic inhibitory facility in ciliary smooth muscle was observed in 27% of emmetropes, 21% of early-onset myopes and 29% of late-onset myopes. Twenty-six percent of all subjects demonstrated access to sympathetic facility. Closed-loop oculomotor function did not differ significantly between subjects with sympathetic facility, and those with sympathetic deficit. Conclusions: Emmetropic and myopic groups cannot be distinguished in terms of the relative proportions having access to sympathetic inhibition. Presence of sympathetic innervation does not have a significant effect on accommodative function under closed-loop viewing conditions. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years the science of risk management has developed substantially, and many large companies and public sector organisations have established separate risk functions employing specialist staff. The reasons behind such developments are varied but they denote an increasing consciousness of a need to actively manage risks and, in compliance with regulations on corporate governance, ensure that an effective internal control system is in operation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Swallowable capsule endoscopy is used for non-invasive diagnosis of some gastrointestinal (GI) organs. However, control over the position of the capsule is a major unresolved issue. This study presents a design for steering the capsule based on magnetic levitation. The levitation is stabilized with the aid of a computer-aided feedback control system and diamagnetism. Peristaltic and gravitational forces to be overcome were calculated. A levitation setup was built to analyze the feasibility of using Hall Effect sensors to locate the in- vivo capsule. CAD software Maxwell 3D (Ansoft, Pittsburgh, PA) was used to determine the dimensions of the resistive electromagnets required for levitation and the feasibility of building them was examined. Comparison based on design complexity was made between positioning the patient supinely and upright.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The sheer volume of citizen weather data collected and uploaded to online data hubs is immense. However as with any citizen data it is difficult to assess the accuracy of the measurements. Within this project we quantify just how much data is available, where it comes from, the frequency at which it is collected, and the types of automatic weather stations being used. We also list the numerous possible sources of error and uncertainty within citizen weather observations before showing evidence of such effects in real data. A thorough intercomparison field study was conducted, testing popular models of citizen weather stations. From this study we were able to parameterise key sources of bias. Most significantly the project develops a complete quality control system through which citizen air temperature observations can be passed. The structure of this system was heavily informed by the results of the field study. Using a Bayesian framework the system learns and updates its estimates of the calibration and radiation-induced biases inherent to each station. We then show the benefit of correcting for these learnt biases over using the original uncorrected data. The system also attaches an uncertainty estimate to each observation, which would provide real world applications that choose to incorporate such observations with a measure on which they may base their confidence in the data. The system relies on interpolated temperature and radiation observations from neighbouring professional weather stations for which a Bayesian regression model is used. We recognise some of the assumptions and flaws of the developed system and suggest further work that needs to be done to bring it to an operational setting. Such a system will hopefully allow applications to leverage the additional value citizen weather data brings to longstanding professional observing networks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since privatisation, maintenance of DNO LV feeder maximum demand information has gradually demised in some Utility Areas, and it is postulated that lack of knowledge about 11kV and LV electrical networks is resulting in a less economical and energy efficient Network as a whole. In an attempt to quantify the negative impact, this paper examines ten postulated new connection scenarios for a set of real LV load readings, in order to find the difference in design solutions when LV load readings were and were not known. The load profiles of the substations were examined in order to explore the utilisation profile. It was found that in 70% of the scenarios explored, significant cost differences were found. These cost differences varied by an average of 1000%, between schemes designed with and without load readings. Obviously, over designing a system and therefore operating more, underutilised transformers becomes less financially beneficial and less energy efficient. The paper concludes that new connection design is improved in terms of cost when carried out based on known LV load information and enhances the case for regular maximum feeder demand information and/or metering of LV feeders. © 2013 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Removal of dissolved salts and toxic chemicals in water, especially at a few parts per million (ppm) levels is one of the most difficult problems. There are several methods used for water purification. The choice of the method depends mainly on the level of feed water salinity, source of energy and type of contaminants present. Distillation is an age old method which can remove all types of dissolved impurities from contaminated water. In multiple effect distillation (MED) latent heat of steam is recycled several times to produce many units of distilled water with one unit of primary steam input. This is already being used in large capacity plants for treating sea water. But the challenge lies in designing a system for small scale operations that can treat a few cubic meters of water per day, especially suitable for rural communities where the available water is brackish. A small scale MED unit with an extendable number of effects has been designed and analyzed for optimum yield in terms of total distillate produced. © 2010 Elsevier B.V.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Wireless Sensor Network (WSN) systems have become more and more popular in our modern life. They have been widely used in many areas, such as smart homes/buildings, context-aware devices, military applications, etc. Despite the increasing usage, there is a lack of formal description and automated verification for WSN system design. In this paper, we present an approach to support the rigorous verification of WSN modeling using the Semantic Web technology We use Web Ontology Language (OWL) and Semantic Web Rule Language (SWRL) to define a meta-ontology for the modeling of WSN systems. Furthermore, we apply ontology reasoners to perform automated verification on customized WSN models and their instances. We demonstrate and evaluate our approach through a Light Control System (LCS) as the case study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A dolgozat a visszutas logisztikát, az újrahasznosítást igyekszik beilleszteni a vállalati termeléstervezés keretei közé. A szükséglettervezési rendszerek (material requirements planning, MRP) célja a készletek és beszerzendő anyagok, alkatrészek időben ütemezett gyártásának és beszerzésének megtervezése. A klasszikus MRP rendszereket az utóbbi időben próbálja a tudomány az újrahasznosítással kibővíteni. Mivel ebben az esetben az új, és újrafelhasználható anyagokat külön kell nyilvántartani, ezért az MRP-táblák és készletek növekednek. A rendelési tételnagyságok meghatározása is nehezebb, összetettebb tételnagysághoz vezet. A dolgozatban egy visszutas logisztikai készletmodellt ismertetünk, valamint annak dinamikus kiterjesztését, amely alapja lehet az SAP-ba beépíthető rendelés állomány meghatározó heurisztikának. ____ The aim of the paper is to extend production planning with reverse logistics and reuse. Material requirements planning (MRP) systems plan and control invetory levels and purchasing activities of the firm. In the last decade scientists on this field try to involve reverse logistics activities in MRP systems. Size of MRP-tables is growing in this case because of the alternative use of newly purchased products and reusable old items. Determination of order quantities will be more complex with these two modes of material supplies. An EOQ-type reverse logistics model is presented in the paper with a dynamic lot size generalization. The generalized model can be seen as a basic model to build in production planning and control system like SAP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years, urban vehicular ad hoc networks (VANETs) are gaining importance for inter-vehicle communication, because they allow for the local communication between vehicles without any infrastructure, configuration effort, and without expensive cellular networks. But such architecture may increase the complexity of routing since there is no central control system in urban VANETs. Therefore, a challenging research task is to improve urban VANETs' routing efficiency. ^ Hence, in this dissertation we propose two location-based routing protocols and a location management protocol to facilitate location-based routing in urban VANETs. The Multi-hop Routing Protocol (MURU) is proposed to make use of predicted mobility and geometry map in urban VANETs to estimate a path's life time and set up robust end-to-end routing paths. The Light-weight Routing Protocol (LIRU) is proposed to take advantage of the node diversity under dynamic channel condition to exploit opportunistic forwarding to achieve efficient data delivery. A scalable location management protocol (MALM) is also proposed to support location-based routing protocols in urban VANETs. MALM uses high mobility in VANETs to help disseminate vehicles' historical location information, and a vehicle is able to implement Kalman-filter based predicted to predict another vehicle's current location based on its historical location information. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High efficiency of power converters placed between renewable energy sources and the utility grid is required to maximize the utilization of these sources. Power quality is another aspect that requires large passive elements (inductors, capacitors) to be placed between these sources and the grid. The main objective is to develop higher-level high frequency-based power converter system (HFPCS) that optimizes the use of hybrid renewable power injected into the power grid. The HFPCS provides high efficiency, reduced size of passive components, higher levels of power density realization, lower harmonic distortion, higher reliability, and lower cost. The dynamic modeling for each part in this system is developed, simulated and tested. The steady-state performance of the grid-connected hybrid power system with battery storage is analyzed. Various types of simulations were performed and a number of algorithms were developed and tested to verify the effectiveness of the power conversion topologies. A modified hysteresis-control strategy for the rectifier and the battery charging/discharging system was developed and implemented. A voltage oriented control (VOC) scheme was developed to control the energy injected into the grid. The developed HFPCS was compared experimentally with other currently available power converters. The developed HFPCS was employed inside a microgrid system infrastructure, connecting it to the power grid to verify its power transfer capabilities and grid connectivity. Grid connectivity tests verified these power transfer capabilities of the developed converter in addition to its ability of serving the load in a shared manner. In order to investigate the performance of the developed system, an experimental setup for the HF-based hybrid generation system was constructed. We designed a board containing a digital signal processor chip on which the developed control system was embedded. The board was fabricated and experimentally tested. The system's high precision requirements were verified. Each component of the system was built and tested separately, and then the whole system was connected and tested. The simulation and experimental results confirm the effectiveness of the developed converter system for grid-connected hybrid renewable energy systems as well as for hybrid electric vehicles and other industrial applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.