956 resultados para Depth of anesthesia
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This systematic review of the Brazilian and worldwide literature aims to evaluate the incidence and causes of perioperative and anesthesia-related mortality. Studies were identified by searching the Medline and Scielo databases, followed by a manual search for relevant articles. Our review includes studies published between 1954 and 2007. Each publication was reviewed to identify author(s), study period, data source, perioperative mortality rates, and anesthesia-related mortality rates. Thirty-three trials were assessed. Brazilian and worldwide studies demonstrated a similar decline in anesthesia-related mortality rates, which amounted to fewer than 1 death per 10,000 anesthetics in the past two decades. Perioperative mortality rates also decreased during this period, with fewer than 20 deaths per 10,000 anesthetics in developed countries. Brazilian studies showed higher perioperative mortality rates, from 19 to 51 deaths per 10,000 anesthetics. The majority of perioperative deaths occurred in neonates, children under one year, elderly patients, males, patients of ASA III physical status or poorer, emergency surgeries, during general anesthesia, and cardiac surgery followed by thoracic, vascular, gastroenterologic, pediatric and orthopedic surgeries. The main causes of anesthesia-related mortality were problems with airway management and cardiocirculatory events related to anesthesia and drug administration. Our systematic review of the literature shows that perioperative mortality rates are higher in Brazil than in developed countries, while anesthesia-related mortality rates are similar in Brazil and in developed countries. Most cases of anesthesia-related mortality are associated with cardiocirculatory and airway events. These data may be useful in developing strategies to prevent anesthesia-related deaths.
Resumo:
Objective: Postoperative agitation in children is a well-documented clinical phenomenon with incidence ranging from 10% to 67%. There is no definitive explanation for this agitation. Possible causes include rapid awakening in unfamiliar settings, pain (wounds, sore throat, bladder distension, etc.), stress during induction, hypoxemia, airway obstruction, noisy environment, anesthesia duration, child's personality, premedication and type of anesthesia. The purpose of this paper is to discuss the possible causes of postoperative agitation in children, providing a foundation for better methods of identifying and preventing this problem.Sources: MEDLINE and PubMed were searched using the following words: emergence, agitation, incidence, etiology, diagnosis, treatment, children, pediatric, anesthesia.Summary of the findings: This study includes a review of potential agitation trigger factors and a proposal for a standardized diagnostic score system, in addition to measures to improve prevention and treatment.Conclusion: No single factor can identified as the cause of postoperative agitation, which should therefore be considered a syndrome made up of biological, pharmacological, psychological and social components, and which anesthesiologists and pediatric intensive care specialists should be prepared to identify, prevent and intervene appropriately as necessary.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
ObjectiveTo compare the post-operative analgesic effects of butorphanol or firocoxib in dogs undergoing ovariohysterectomy.Study designProspective, randomized, blinded, clinical trial.AnimalsTwenty-five dogs > 1 year of age.MethodsDogs received acepromazine intramuscularly (IM), 0.05 mg kg-1 and either butorphanol IM, 0.2 mg kg-1 (BG, n = 12) or firocoxib orally (PO), 5 mg kg-1 (FG, n = 13), approximately 30 minutes before induction of anesthesia with propofol. Anesthesia was maintained with isoflurane. Ovariohysterectomy was performed by the same surgeon. Pain scores using the dynamic and interactive visual analog scale (DIVAS) were performed before and at 1, 2, 3, 4, 6, 8 and 20 hours after the end of surgery by one observer, blinded to the treatment. Rescue analgesia was provided with morphine (0.5 mg kg-1) IM and firocoxib, 5 mg kg-1 (BG only) PO if DIVAS > 50. Groups were compared using paired t-tests and Fisher's exact test (p < 0.05). Data are presented as mean +/- SD.ResultsThe BG required significantly less propofol (BG: 2.6 +/- 0.59 mg kg-1; FG: 5.39 +/- 0.7 mg kg-1) (p < 0.05) but the anesthesia time was longer (BG: 14 +/- 6, FG: 10 +/- 4 minutes). There were no differences for body weight (BG: 7.9 +/- 5.0, FG: 11.5 +/- 4.6 kg), sedation scores, and surgery and extubation times (BG: 10 +/- 2, 8 +/- 5 minutes; FG: 9 +/- 3, 8 +/- 4 minutes, respectively) (p > 0.05). The FG had significantly lower pain scores than the BG at 1, 2 and 3 hours following surgery (p < 0.05). Rescue analgesia was administered to 11/12 (92%) and 2/13 (15%) dogs in the BG and FG, respectively (p < 0.05).Conclusion and clinical relevanceFirocoxib produced better post-operative analgesia than butorphanol. Firocoxib may be used as part of a multimodal analgesia protocol but may not be effective as a sole analgesic.
Resumo:
ObjectiveTo investigate the cardiorespiratory, nociceptive and endocrine effects of the combination of propofol and remifentanil, in dogs sedated with acepromazine.Study designProspective randomized, blinded, cross-over experimental trial.AnimalsTwelve healthy adult female cross-breed dogs, mean weight 18.4 +/- 2.3 kg.MethodsDogs were sedated with intravenous (IV) acepromazine (0.05 mg kg-1) followed by induction of anesthesia with IV propofol (5 mg kg-1). Anesthesia was maintained with IV propofol (0.2 mg kg-1 minute-1) and remifentanil, infused as follows: R1, 0.125 mu g kg-1 minute-1; R2, 0.25 mu g kg-1 minute-1; and R3, 0.5 mu g kg-1 minute-1. The same dogs were administered each dose of remifentanil at 1-week intervals. Heart rate (HR), mean arterial pressure (MAP), respiratory rate (f(R)), end tidal CO(2) (Pe'CO(2)), arterial hemoglobin O(2) saturation, blood gases, and rectal temperature were measured before induction, and 5, 15, 30, 45, 60, 75, 90, and 120 minutes after beginning the infusion. Nociceptive response was investigated by electrical stimulus (50 V, 5 Hz and 10 ms). Blood samples were collected for plasma cortisol measurements. Statistical analysis was performed by anova (p < 0.05).ResultsIn all treatments, HR decreased during anesthesia with increasing doses of remifentanil, and increased significantly immediately after the end of infusion. MAP remained stable during anesthesia (72-98 mmHg). Antinociception was proportional to the remifentanil infusion dose, and was considered satisfactory only with R2 and R3. Plasma cortisol concentration decreased during anesthesia in all treatments. Recovery was smooth and fast in all dogs.Conclusions and clinical relevanceInfusion of 0.25-0.5 mu g kg-1 minute-1 remifentanil combined with 0.2 mg kg-1 minute-1 propofol produced little effect on arterial blood pressure and led to a good recovery. The analgesia produced was sufficient to control the nociceptive response applied by electrical stimulation, suggesting that it may be appropriate for performing surgery.
Resumo:
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to analyze the histometry of ligature-induced periodontitis in rats at different histological section depths. Sixteen male adult Wistar rats were randomly assigned to two groups: ligature and control. In the ligature group, rats received a sterile 4/0 silk ligature around the maxillary right 2nd molar. Thirty serial sections containing the 1st and 2nd molars, in which the coronal and root pulp, cementoenamel junction (CEJ) in the mesial side of the 2nd molar, interproximal alveolar bone and connective fiber attachment were clearly visible, were selected for histometric analysis. The histological sections were clustered in groups of 10 sections corresponding the buccal (B), central (C) and lingual (L) regions of the of periodontal tissue samples. The distance between the CEJ in the mesial side of the 2nd molar and the attached periodontal ligament fibers (CEJ-PL) as well as the distance between the CEJ and the alveolar bone crest (CEJ-BC) were determined. From CEJ-PL and CEJ-BC distances measured for each specimen, the measurements obtained in the B, L and C regions were recorded individually and together. Data were submitted to statistical analysis. Significant differences (p<0.001) were observed between the control and ligature groups regarding CEJ-PL (0.05 mm and 0.26 mm, respectively) and CEJ-BC (0.47 mm and 0.77 mm, respectively) measurements. Regarding the depth of the buccal, central and lingual planes, the means of CEJ-PL and CEJ-BC of both groups showed no statistically significant differences (p>0.05). In conclusion, the selection of 10 serial sections of the central region of periodontal tissue samples at any depth can be considered as representative for the evaluation of periodontal ligament fiber attachment and bone loss in ligature-induced periodontitis in rats.
Resumo:
The aim of this study was to compare the micromorphology of CVD diamond tips coupled to ultrasound with conventional high speed diamond tips after cavity preparations, and to measure the width and depth of the cavities obtained. Two hundred bovine teeth were divided into 20 subgroups. Each of the diamond tips (10 CVD and 10 conventional) were used to prepare 10 standardized cavities, using an apparatus that controlled the time (t: 27 s), speed (5.3 mm/s) and load (0.012 KGF) of the tip against the teeth during preparation. The unused and the used (after one, five and 10 preparations) tips were analyzed by scanning electronic microscopy. The images were randomly assessed by 3 examiners with regard to the presence or absence of micromorphologic alterations. Cavity measurements were made after visualization under a stereoscopic microscope. Cavity widths and depths were analyzed by the ANOVA Factorial test (p < 0.05). The CVD diamond tips presented less wear than the conventional tips after all the cavity preparations performed, but produced shallower cavities that were equivalent in width to those made by conventional tips after the fifth preparation. CVD diamond tips may be suggested as an alternative to conventional diamond tips due to their conservative preparation and greater longevity.
Resumo:
This in vitro study evaluated the marginal gap at the composite tooth/resin interface in class V cavities under the influence of two insertion techniques and a curing system by means of atomic force microscopy (AFM). Forty enamel and dentin cavities were prepared on the buccal surface in bovine teeth with quadratic forms measuring 2 mm X 2 mm and depth of 1.5 mm. The teeth were then divided into four groups: group A, 10 cavities were restored in one increment, light cured by halogen light; group B, 10 cavities filled with bulk filling, light cured by the light emitting diodes (LED); group C, 10 cavities were restored by the incremental technique, light cured by halogen light; group D, 10 cavities were restored by the incremental technique, light cured by the LED. The teeth underwent the polishing procedure and were analyzed by AFM for tooth/restoration interface evaluation. The data were compared between groups using the nonparametric Kruskall-Wallis and Mann-Whitney tests (p < 0.05). The results showed a statistically significant difference between groups A and B and groups A and C. It was concluded that no insertion and polymerization technique was able to completely seal the cavity.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. The objective of this study was to evaluate the penetration of 2.5% NaOCl associated with 17.0% EDTA, 1.0% citric acid, and 1.0% peracetic acid into dentin tubules.Study design. The roots of 44 bovine incisors were cross-sectioned and 5-mm-long fragments were produced from their middle thirds. The specimens were instrumented with ProTaper hand files, stained in crystal violet, then sectioned mesiodistally. The buccal fragments were divided into 4 groups (n = 9) and subjected to 2 consecutive 10-minute immersion periods in one of the following acid solutions combined with 2.5% NaOCl: 17.0% EDTA (group 1), 1.0% citric acid (group 2), and 1.0% peracetic acid (group 3). Nine fragments were immersed in 2.5% NaOCl (group 4). The analysis of the penetration of NaOCl solutions into dentin was performed by measuring the depth of crystal violet stain that was bleached using a steromicroscope under x50 magnification. Statistical comparisons were carried out by Kruskal-Wallis and Dunn's tests at the 5% significance level.Results. Group 1 showed less penetration into dentin than group 4 (P < .05). No statistically significant differences were observed among groups 2, 3, and 4 (P > .05).Conclusions. Association of NaOCl with acid solutions did not increase its penetration depth into root dentin. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;112:e155-e159)
Resumo:
The aim of this study was to perform a morphometric analysis of the various parts of the intestine of the domestic quail. Twenty-four female quails (Coturnix coturnix japonica) aged 37 weeks were used and accommodated in laying cages for 12 weeks. Each group was fed a standardized diet containing different quantities of calcium: 2.0%, 2.5%. 3.0% and 3.5%. The birds were weighed, killed, and samples of 1 cm were collected from the duodenum, jejunum and ileum and submitted to the histological routine. The sections obtained were stained in haematoxylin & eosin (H&E). For morphometric analysis, 30 villi and 30 crypts of each segment of the small intestine were measured in order to determine the height and area of the villi, as well as the depth of the crypts. The results showed that although the integrity of the gastrointestinal tract was maintained in all the birds treated with the different calcium levels, a calcium level of 3.0% showed the most promise, as the levels of 2.0% and 2.5% did not cause any alteration in the intestinal tract. Furthermore, a calcium level of 3.5% led to a significant reduction in the height of the villosities, and in consequence reduced the digestive and absorptive capabilities.