945 resultados para Dental adaptation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the degree of conversion and hardness of a dental composite resin Filtek (TM) Z-350 (3M ESPE, Dental Products St. Paul, MN) photo-activated for 20 s of irradiation time with two different light guide tips, metal and polymer, coupled on blue LED Ultraled LCU (Dabi Atlante, SP, Brazil). With the metal light tip, power density was of 352 and with the polymer was of 456 mW/cm(2), respectively. Five samples (4 mm in diameter and 2mm in thickness-ISO 4049), were made for each Group evaluated. The measurements for DC (%) were made in a Nexus-470 FT-IR, Thermo Nicolet, E.U.A. Spectroscopy (FTIR). Spectra for both uncured and cured samples were analyzed using an accessory of reflectance diffuse. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm(-1) resolution, 300-4000 cm(-1) wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm(-1)) against internal standard before and after curing of the sample: aromatic C-C (peak at 1610 cm(-1)). The Vickers hardness measurements (top and bottom surfaces) were performed in a universal testing machine (Buehler MMT-3 digital microhardness tester Lake Bluff, Illinois USA). A 50 gf load was used and the indenter with a dwell time of 30 s. The data were submitted to the test t Student at significance level of 5%. The mean values of degree of conversion for the polymer and metal light guide tip no were statistically different (p = 0.8389). The hardness mean values were no statistically significant different among the light guide tips (p = 0.6244), however, there was difference between top and bottom surfaces (p < 0.001). The results show that so much the polymer light tip as the metal light tip can be used for the photo-activation, probably for the low quality of the light guide tip metal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental composite resins possess good esthetic properties, and are currently among the most popular dental restorative materials. Both organic and inorganic phases might influence the material behavior, the filler particle features and rate are the most important factors related to improvement of the mechanical properties of resin composites. Thus, the objective of this study was to evaluate the effect of three different composite resins on the polymerization process by Vickers hardness test. The samples were prepared using three different composite resins, as follow: group I-P-60 (3M/ESPE); group II-Herculite XRV (Kerr), and group III-Durafill (Heraeus-Kulzer). The samples were made in a polytetrafluoroethylene mould, with a rectangular cavity measuring 7 mm in length, 4 mm in width, and 3 mm in thickness. The samples were photo-activated by one light-curing unit based on blue LEDs (Ultrablue III-DMC/Brazil) for 20 and 40 s of irradiation times. The Vickers hardness test was performed 24 h after the photo-activation until the standardized depth of 3 mm. The Vickers hardness mean values varied from 158.9 (+/- 0.81) to 81.4 (+/- 1.94) for P-60, from 138.7 (+/- 0.37) to 61.7 (+/- 0.24) for Herculite XRV, and from 107. 5 (+/- 0.81) to 44.5 (+/- 1.36) for Durafill composite resins photo-activated during 20 s for the 1st and 2nd mm, respectively. During 40 s of photo-activation, the Vickers hardness mean values were: from 181.0 (+/- 0.70) to 15.6 (+/- 0.29) for P-60, and from 161.8 (+/- 0.41) to 11.2 (+/- 0.17) for Herculite XRV composite resins, for the 1st and 3th mm, respectively. For Durafill composite resin the mean values varied from 120.1 (+/- 0.66) to 61.7 (+/- 0.20), for the 1st and 2nd mm, respectively. The variation coefficient (CV) was in the most of the groups lower than 1%, then the descriptive statistic analysis was used. The Vickers hardness mean values for Durafill were lower than P-60 and Herculite XRV composite resins for 20 and 40 s of irradiation time. The polymerization process was greatly affected by the composition of the composite resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hypothesis that low-level laser therapy (LLLT) 688 nm and 785 nm accelerate dentin barrier formation and repair process after traumatic pulp exposure. The sample consisted of 45 premolars of capuchin monkeys (Cebus apella) with pulp exposure Class V cavities. All premolars were treated with calcium hydroxide (Ca(OH)(2)), divided in groups of 15 teeth each, and analyzed on 7(th), 25(th), and 60(th) day. Group GI - only Ca(OH)(2), GIF- laser 688 nm, and GIII - laser 785 nm. Laser beam was used in single and punctual dose with the parameters: continuous, 688 nm and 785 nm wavelength, tip`s area of 0.00785 cm(2), power 50 mW, application time 20 s, dose 255 J/cm(2), energy 2 J. Teeth were capped with Ca(OH)(2), Ca(OH)(2) cement and restored with amalgam. All groups presented pulp repair. On 25(th) day the thickness of the formed dentin barrier was different between the groups GI and GII (p < 0.05) and between groups GI and GIII (p < 0.01). On 60(th) day there was difference between GI and GIII (p < 0.01). It may be concluded that, LLLT 688 nm and 785 nm accelerated dentin barrier formation and consequently pulp repair process, with best results using infrared laser 785 nm. (c) 2009 by Astro Ltd. Published exclusively by WLLEY-VCH Verlag GmbH & Co. KGaA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement error models often arise in epidemiological and clinical research. Usually, in this set up it is assumed that the latent variable has a normal distribution. However, the normality assumption may not be always correct. Skew-normal/independent distribution is a class of asymmetric thick-tailed distributions which includes the Skew-normal distribution as a special case. In this paper, we explore the use of skew-normal/independent distribution as a robust alternative to null intercept measurement error model under a Bayesian paradigm. We assume that the random errors and the unobserved value of the covariate (latent variable) follows jointly a skew-normal/independent distribution, providing an appealing robust alternative to the routine use of symmetric normal distribution in this type of model. Specific distributions examined include univariate and multivariate versions of the skew-normal distribution, the skew-t distributions, the skew-slash distributions and the skew contaminated normal distributions. The methods developed is illustrated using a real data set from a dental clinical trial. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insect digestive chymotrypsins are present in a large variety of insect orders but their substrate specificity still remains unclear. Ewer insect chymotrypsins from 3 different insect orders (Dictyoptera, Coleoptera and two Lepidoptera) were isolated using affinity chromatography. Enzymes presented molecular masses in the range of 20 to 31 kDa and pH optima in the range of 7.5 to 10.0. Kinetic characterization. using different, colorimetric and fluorescent substrates indicated that insect chymotrypsins differ from, bovine chymotrypsin in their primary specificity toward small substrates (like N-benzoyl-L-Tyr p-nitroanilide) rather than on their preference for large substrates (exemplified by Succynil-Ala-Ala-Pro-Phe P-nitroanilide). Chloromethyl ketones (TPCK, N-alpha-tosyl-L-Phe chloromethyl ketone and Z-GGF-CK, N-carbobenzoxy-Gly-Gly-phe-CK) inactivated all chymotrypsins legated. Inactivation rates follow apparent first-order kinetics with variable second order rates (TPCK, 42 to 130 M(-1)s(-1); Z-GGF-CK, 150 to 450 M(-1)s(-1) that may be remarkably low for S. frugiperda chymotrypsin (TPCK, 6 M(-1)s(-1); Z-GGF-CK, 6.1 M(-1) s(-1)). Homology modelling and sequence alignment showed that. in lepidopteran chymotrypsins, differences in the amino acid residues in the neighborhood of the catalytic His 57 may affect its pKa, value. This is Proposed as the cause of the decrease in His 57 reactivity toward chloromethyl ketones. Such amino acid replacement in the active site is proposed. to be an adaptation to the presence of dietary ketones. (C) 2009 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental composites can be improved by heat treatment, as a possible way to increase mechanical properties due to additional cure (post-cure). Direct dental composites are essentially similar to the indirect ones, supposing they have the same indication. Therefore, to establish a heat treatment protocol for direct composites, using as indirect (photoactivated by continuous and pulse-delay techniques), a characterization (TG/DTG and DSC) is necessary to determine parameters, such as mass loss by thermal decomposition, heat of reaction and glass transition temperature (T (g)). By the results of this study, a heat treatment could be carried out above 160 A degrees C (above T (g), and even higher than the endset exothermic event) and under 180 A degrees C (temperature of significant initial mass loss).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead (Pb) poisoning is preventable but continues to be a public health problem in several countries. Measuring Pb in the surface dental enamel (SDE) using microbiopsies is a rapid, safe, and painless procedure. There are different protocols to perform these microbiopsies, but the reliability of dental enamel lead levels (DELL) determination is dependent upon biopsy depth (BD). It is established that DELL decrease from the outermost superficial layer to the inner layer of dental enamel. The aim of this study was to determine DELL obtained by two different microbiopsy techniques on SDE termed protocol I and protocol II. Two consecutive enamel layers were removed from the same subject group (n = 138) for both protocols. Protocol I consisted of a biopsied site with a diameter of 4 mm after the application of 10 l HCl for 35 s. Protocol II involved a biopsied site of 1.6 mm diameter after application of 5 l HCl for 20 s. The results demonstrated that there were no significant differences for BD and DELL between homologous teeth using protocol I. However, there was a significant difference between DELL in the first and second layers using both protocols. Further, the BD in protocol II overestimated DELL values. In conclusion, SDE analyzed by microbiopsy is a reliable biomarker in protocol I, but the chemical method to calculate BD in protocol II appeared to be inadequate for measurement of DELL. Thus, DELL could not be compared among studies that used different methodologies for SDE microbiopsies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in situ double-blind randomised crossover study was to investigate the effect of calcium (Ca) pre-rinse on the composition of plaque and on enamel prior to the use of fluoride (F) dentifrice. Materials and Methods: During four phases (14 days each) of this study, 10 volunteers had agreed to wear dental appliances containing two healthy bovine enamel blocks. A fresh solution containing 20% weight/volume (w/v) sucrose was dripped on the enamel blocks ex vivo for 5 min three times a day. Subsequently, the appliances were replaced in the mouth, and the volunteers rinsed their mouth with 10 mL of a Ca (150 mmol/L) or a placebo rinse (1 min). In sequence, a slurry (1:3 w/v) of F (1030 ppm) or placebo dentifrice was dripped onto the blocks ex vivo for 1 min. During this time, the volunteers brushed their teeth with the respective dentifrice. The appliances were replaced in the mouth, and the volunteers rinsed their mouth with water. The plaque formed on the blocks was analysed for F and Ca. The enamel demineralisation as well as the incorporation of F on enamel was evaluated by cross-sectional microhardness and alkali-soluble F analysis, respectively. Data were tested using analysis of variance (P < 0.05). Results: The Ca pre-rinse prior to the use of the F dentifrice led to a three- and sixfold increase in the plaque F and Ca concentrations, respectively. It also did not have any additive effect on the F content on the enamel and the demineralisation of the enamel, in comparison with the use of F dentifrice alone. Conclusions: A Ca lactate rinse used prior to the F dentifrice was able to change the mineral content in the plaque, but it was unable to prevent enamel demineralisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the use of a dental amalgam electrode (DAE) to evaluate the electrochemical behaviour and to develop an electroanalytical procedure for determination of diquat herbicide in natural water and potato samples. The work was based on the square wave voltammetry responses of diquat, which presented two well-defined and reversible reduction peaks, at -0.56 V (peak 1) and -1.00V (peak 2). The experimental and voltammetric parameters were optimised, and the analytical curves were constructed and compared to similar curves performed by high performance liquid chromatography coupled to ultraviolet-visible spectrophotometric detector (HPLC/UV-vis). The responses were directly proportional to diquat concentration in a large interval of concentration, and the calculated detection limits were very similar, around 10 mu g L(-1) (10 ppb) for voltammetric and chromatographic experiments. These values were lower than the maximum residue limit established for natural water by the Brazilian Environmental Agency. The recovery percentages in pure electrolyte, natural water and potato samples showed values from 70% to 130%, demonstrating that the voltammetric methodology proposed is suitable for determining any contamination by diquat in different samples, minimising the toxic residues due to the use of liquid mercury or the adsorptive process relative to use of other solid surfaces. (C) 2009 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different compositions of visible-light-curable triethylene glycol dimethacrylate/bisglycidyl methacrylate copolymers used in dental resin formulations were prepared through copolymerization photoinitiated by a camphorquinone/ethyl 4-dimethylaminobenzoate system irradiated with an Ultrablue IS light-emitting diode. The obtained copolymers were evaluated with differential scanning calorimetry. From the data for the heat of polymerization, before and after light exposure, obtained from exothermic differential scanning calorimetry curves, the light polymerization efficiency or degree of conversion of double bonds was calculated. The glass-transition temperature also was determined before and after photopolymerization. After the photopolymerization, the glass-transi-tion temperature was not well defined because of the breadth of the transition region associated with the properties of the photocured dimethacrylate. The glass-transition temperature after photopolymerization was determined experimentally and compared with the values determined with the Fox equation. In all mixtures, the experimental value was lower than the calculated value. Scanning electron microscopy was used to analyze the morphological differences in the prepared copolymer structures. (C) 2007 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of the storage time on the thermal properties of triethylene glycol dimethacrylate/2,2-bis[4-(2-hydroxy-3-methacryloxy-prop-1-oxy)-phenyl]propane bisphenyl-alpha-glycidyl ether dimethacrylate (TB) copolymers used in formulations of dental resins after photopolymerization. The TB copolymers were prepared by photopolymerization with an Ultrablue IS light-emitting diode, stored in the dark for 160 days at 37 degrees C, and characterized with differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), and Fourier transform infrared spectroscopy with attenuated total reflection. DSC curves indicated the presence of an exothermic peak, confirming that the reaction was not completed during the photopolymerization process. This exothermic peak became smaller as a function of the storage time and was shifted at higher temperatures. In DMA studies, a plot of the loss tangent versus the temperature initially showed the presence of two well-defined peaks. The presence of both peaks confirmed the presence of residual monomers that were not converted during the photopolymerization process. (C) 2009 Wiley Periodicals, Inc. J Appl Polym Sci 112: 679-684, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research question – The research question, that this study attempts to answer, is, what and why grocery retailers, which specifically work with the strategy of standardization, adapt in their marketing mix to the host market. Main adaptations are analyzed with regard to psychic distance in terms of consumer characteristics. Methodology – This study presents a qualitative research design. Secondary data, in-depth interviews and personal observations were used, in order to identify adaptations, which were conducted in a grocery retailer in Germany, which is its home market, and in Sweden, which is considered to be a host market. Findings – The main findings of this research indicate that grocery retailers that specifically work with the strategy of standardization, adopt their core strategy at the host market, in order to keep their economy of scale. However, the standardization strategy may cause negative financial results, which is why adaptations, in order to attract new customers, are required. Conclusively, a mix of both, the adaptation and standardization marketing strategy, has to be utilized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The World Health Organisation suggests that simplification of the medical abortion regime will contribute to an increased acceptability of medical abortion, among women as well as providers. It is expected that a home-based follow-up after a medical abortion will increase the willingness to opt for medical abortion as well as decrease the workload and service costs in the clinic. Trial design The study is a randomised, controlled, non-superiority trial . Methods Women screened to participate in the study are those with unwanted pregnancies and gestational ages equal to or less than nine weeks. Eligible women randomised to the home-based assessment group will use a low-sensitivity pregnancy test and a pictorial instruction sheet at home, while the women in the clinic follow-up group will return to the clinic for routine follow-up carried out by a doctor. The primary objective of the study is to evaluate the effectiveness of home-based assessment using a low-sensitivity pregnancy test and a pictorial instruction sheet 10-14 days after an early medical abortion. Providers or research assistants will not be blinded during outcome assessment. To ensure feasibility of the self-assessment intervention an adaption phase took place at the selected study sites before study initiation. This was to optimise and tailor-make the intervention and the study procedures and resulted in the development of the pictorial instruction sheet for how to use the low-sensitivity pregnancy test and the danger signs after a medical abortion. Discussion In this paper, we will describe the study protocol for a randomised control trial investigating the efficacy of simplified follow-up in terms of home-based assessment, 10-14 days after a medical abortion. Moreover, a description of the adaptation phase is included for a better understanding of the implementation of the intervention in a setting where literacy is low and the road-connections are poor. Trial registration: Clinicaltrials.gov NCT01827995. Registered 04 May 2013