952 resultados para Dem gross error detection
Resumo:
A new scheme is proposed for the detection of premature ventricular beats, which is a vital function in rhythm monitoring of cardiac patients. A transformation based on the first difference of the digitized electrocardiogram (ECG) signal is developed for the detection and delineation of QRS complexes. The method for classifying the abnormal complexes from the normal ones is based on the concepts of minimum phase and signal length. The parameters of a linear discriminant function obtained from a training feature vector set are used to classify the complexes. Results of application of the scheme to ECG of two arrhythmia patients are presented.
Resumo:
An a priori error analysis of discontinuous Galerkin methods for a general elliptic problem is derived under a mild elliptic regularity assumption on the solution. This is accomplished by using some techniques from a posteriori error analysis. The model problem is assumed to satisfy a GAyenrding type inequality. Optimal order L (2) norm a priori error estimates are derived for an adjoint consistent interior penalty method.
Resumo:
In order to describe the atmospheric turbulence which limits the resolution of long-exposure images obtained using ground-based large telescopes, a simplified model of a speckle pattern, reducing the complexity of calculating field-correlations of very high order, is presented. Focal plane correlations are used instead of correlations in the spatial frequency domain. General tripple correlations for a point source and for a binary are calculated and it is shown that they are not a strong function of the binary separation. For binary separations close to the diffraction limit of the telescope, the genuine triple correlation technique ensures a better SNR than the near-axis Knox-Thompson technique. The simplifications allow a complete analysis of the noise properties at all levels of light.
Resumo:
A symmetrizer of the matrix A is a symmetric solution X that satisfies the matrix equation XA=AprimeX. An exact matrix symmetrizer is computed by obtaining a general algorithm and superimposing a modified multiple modulus residue arithmetic on this algorithm. A procedure based on computing a symmetrizer to obtain a symmetric matrix, called here an equivalent symmetric matrix, whose eigenvalues are the same as those of a given real nonsymmetric matrix is presented.
Resumo:
A cytosine-specific DNA methyltransferase (EC 2.1.1.37) has been purified to near homogeneity from a mealybug (Planococcus lilacinus). The enzyme can methylate cytosine residues in CpG sequences as well as CpA sequences. The apparent molecular weight of the enzyme was estimated as 135,000 daltons by FPLC. The enzyme exhibits a processive mode of action and a salt dependance similar to mammalian methylases. Mealybug methylase exhibits a preference for denatured DNA substrates.
Resumo:
In a number of applications of computerized tomography, the ultimate goal is to detect and characterize objects within a cross section. Detection of edges of different contrast regions yields the required information. The problem of detecting edges from projection data is addressed. It is shown that the class of linear edge detection operators used on images can be used for detection of edges directly from projection data. This not only reduces the computational burden but also avoids the difficulties of postprocessing a reconstructed image. This is accomplished by a convolution backprojection operation. For example, with the Marr-Hildreth edge detection operator, the filtering function that is to be used on the projection data is the Radon transform of the Laplacian of the 2-D Gaussian function which is combined with the reconstruction filter. Simulation results showing the efficacy of the proposed method and a comparison with edges detected from the reconstructed image are presented
Resumo:
Entamoeba histolytica-specific serum IgG, IgA, IgM and IgE antibodies were assayed in cases of amoebiasis in an endemic area. Patient groups consisted of amoebic liver abscess (n=18), pre-abscess hepatic amoebiasis (n=22) and amoebic colitis (n=30). Control subjects comprised 26 asymptomatic cyst passers, 13 giardiasis cases, 20 typhoid patients and 24 non-amoebic individuals. Serum IgG was assayed by ELISA, using a monoclonal anti IgG β- galactosidase (IgG β-gal) conjugate, a polyclonal avidin biotin horse radish peroxidase (AB-HRP), and a polyclonal anti IgG horse radish peroxidase (IgG HRP) conjugate. IgA and IgM were assayed by the β-gal ELISA and IgE by AB-HRP. Diagnostically significant IgG and IgA while lower IgM and IgE antibody levels were seen in extraintestinal cases. About 40% of suspected pre-abscess hepatic amoebiasis cases were confirmed by antibody estimation. All isotype levels in most dysentery cases were in the range of the controls.
Resumo:
With biotin labelled and unlabelled immunoglobulin fraction of anticysticercal antibodies raised in rabbits, tandem-enzyme linked immunosorbent assay (T-ELISA), capture-dot immunobinding assay (C-DIA) and reverse passive haemagglutination (RPHA) tests were developed for the detection of cysticercal antigens. The sensitivity levels were respectively, 9 ng ml−1, 2 ng ml−1 and 45 ng ml−1. All three methods were of equal specificity as none of the antigens of Mycobacterium tuberculosis, Japanese encephalitis virus and Echinococcus granulosus reacted with anticysticercal IgG. Cysticercal antigens were detected in the cerebrospinal fluid (CSF) of confirmed neurocysticercosis at sensitivity levels of 91·6% by T-ELISA, 83·33% by C-DIA and 75% by RPHA and specificity levels of >93%. Western analysis of these antigens in CSF showed mainly antigens of 64–68 kDa and 24–28 kDA. By crossed immunoelectrophoresis (CIE) with an intermediate gel technique, five circulating antigens were found to be released from scolex and fluid.
Resumo:
Microbes in natural and artificial environments as well as in the human body are a key part of the functional properties of these complex systems. The presence or absence of certain microbial taxa is a correlate of functional status like risk of disease or course of metabolic processes of a microbial community. As microbes are highly diverse and mostly notcultivable, molecular markers like gene sequences are a potential basis for detection and identification of key types. The goal of this thesis was to study molecular methods for identification of microbial DNA in order to develop a tool for analysis of environmental and clinical DNA samples. Particular emphasis was placed on specificity of detection which is a major challenge when analyzing complex microbial communities. The approach taken in this study was the application and optimization of enzymatic ligation of DNA probes coupled with microarray read-out for high-throughput microbial profiling. The results show that fungal phylotypes and human papillomavirus genotypes could be accurately identified from pools of PCR amplicons generated from purified sample DNA. Approximately 1 ng/μl of sample DNA was needed for representative PCR amplification as measured by comparisons between clone sequencing and microarray. A minimum of 0,25 amol/μl of PCR amplicons was detectable from amongst 5 ng/μl of background DNA, suggesting that the detection limit of the test comprising of ligation reaction followed by microarray read-out was approximately 0,04%. Detection from sample DNA directly was shown to be feasible with probes forming a circular molecule upon ligation followed by PCR amplification of the probe. In this approach, the minimum detectable relative amount of target genome was found to be 1% of all genomes in the sample as estimated from 454 deep sequencing results. Signal-to-noise of contact printed microarrays could be improved by using an internal microarray hybridization control oligonucleotide probe together with a computational algorithm. The algorithm was based on identification of a bias in the microarray data and correction of the bias as shown by simulated and real data. The results further suggest semiquantitative detection to be possible by ligation detection, allowing estimation of target abundance in a sample. However, in practise, comprehensive sequence information of full length rRNA genes is needed to support probe design with complex samples. This study shows that DNA microarray has the potential for an accurate microbial diagnostic platform to take advantage of increasing sequence data and to replace traditional, less efficient methods that still dominate routine testing in laboratories. The data suggests that ligation reaction based microarray assay can be optimized to a degree that allows good signal-tonoise and semiquantitative detection.
Resumo:
In this paper we present simple methods for construction and evaluation of finite-state spell-checking tools using an existing finite-state lexical automaton, freely available finite-state tools and Internet corpora acquired from projects such as Wikipedia. As an example, we use a freely available open-source implementation of Finnish morphology, made with traditional finite-state morphology tools, and demonstrate rapid building of Northern Sámi and English spell checkers from tools and resources available from the Internet.
Resumo:
The design and preparation of novel M3L2 trigonal cages via the coordination-driven self-assembly of preorganized metalloligands containing octahedral aluminum(III), gallium(III), or ruthenium(II) centers is described. When tritopic or dinuclear linear metalloligands and appropriate complementary subunits are employed, M3L2 trigonal-bipyramidal and trigonal-prismatic cages are self-assembled under mild conditions. These three-dimensional cages were characterized with multinuclear NMR spectroscopy (H-1 and P-31) and high-resolution electrospray ionization mass spectrometry. The structure of one such trigonal-prismatic cage, self-assembled from an arene ruthenium metalloligand, was confirmed via single-crystal X-ray crystallography. The fluorescent nature of these prisms, due to the presence of their electron-rich ethynyl functionalities, prompted photophysical studies, which revealed that electron-deficient nitroaromatics are effective quenchers of the cages' emission. Excited-state charge transfer from the prisms to the nitroaromatic substrates can be used as the basis for the development of selective and discriminatory turn-off fluorescent sensors for nitroaromatics.
Resumo:
MEMS systems are technologically developed from integrated circuit industry to create miniature sensors and actuators. Originally these semiconductor processes and materials were used to build electrical and mechanical systems, but expanded to include biological, optical fluidic magnetic and other systems 12]. Here a novel approach is suggested where in two different fields are integrated via moems, micro fluidics and ring resonators. It is well known at any preliminary stage of disease onset, many physiological changes occur in the body fluids like saliva, blood, urine etc. The drawback till now was that current calibrations are not sensitive enough to detect the minor physiological changes. This is overcome using optical detector techniques 1]. The basic concepts of ring resonators, with slight variations can be used for optical detection of these minute disease markers. A well known fact of ring resonators is that a change in refractive index will trigger a shift in the resonant wavelength 5]. The trigger for the wavelength shift in the case discussed will be the presence of disease agents. To trap the disease agents specific antibody has to be used (e. g. BSA).
Resumo:
The finite resolution of joint drives or sensors imparts a discrete nature to the joints of a manipulator. Because of this an arbitrary point in the workspace cannot be reached without error even in ideal mechanical environment. This paper investigates the effect of this discrete nature of the joints on the accuracy of performance of a manipulator and develops a method to select the joint states to reach a point with least error. It is shown that the configuration leading to least error cannot, in general, be found from configuration space, especially when there is large variation in the link lengths or joint resolutions or both. The anomaly becomes severe when the gross motion of the end-effector approaches the local resolution of the workspace. The paper also shows how to distinguish two workspaces which may be identical so far as the boundary points are concerned, taking the joint resolutions into account. Finally, the concepts have been extended to define continuous space global and local performance indices for general multi degree of freedom manipulators.
Resumo:
The importance of developing effective assays to diagnose, monitor and evaluate human lymphatic filariasis has been emphasized by the World Health Organization. Presently, few immunodiagnostics are available for filarial monitoring programmes. The Wuchereria bancrofti (Wb) SXP-1 parasite protein, with 84% homology to Brugia malayi (Bm) SXP-1, was found to be highly immunogenic. WbSXP-1 is one among the diagnostic candidate molecules that were used for developing a rapid-antibody-flow-through diagnostic kit for filariasis. Studies were initiated with the aim of developing monoclonal antibodies against recombinant WbSXP-1 and prospective applications for the detection of both circulating Wb and Bm antigens in serum samples from infected individuals. The monoclones 1A6C2 of subclass IgG1k, and 2A12F8 of class IgM, specifically detected Wb and Bm microfilaria isolated from patients and did not show cross-reactivity with other filarial recombinant antigens. We anticipate that this work will address the problems faced in the rapid diagnosis of human lymphatic filariasis in endemic areas in developing countries.
Resumo:
FDDI (Fibre Distributed Data Interface) is a 100 Mbit/s token ring network with two counter rotating optical rings. In this paper various possible faults (like lost token, link failures, etc.) are considered, and fault detection and the ring recovery process in case of a failure and the reliability mechanisms provided are studied. We suggest a new method to improve the fault detection and ring recovery process. The performance improvement in terms of station queue length and the average delay is compared with the performance of the existing fault detection and ring recovery process through simulation. We also suggest a modification for the physical configuration of the FDDI networks within the guidelines set by the standard to make the network more reliable. It is shown that, unlike the existing FDDI network, full connectivity is maintained among the stations even when multiple single link failures occur. A distributed algorithm is proposed for link reconfiguration of the modified FDDI network when many successive as well as simultaneous link failures occur. The performance of the modified FDDI network under link failures is studied through simulation and compared with that of the existing FDDI network.