989 resultados para DENTAL PULP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er: YAG (Erbium: Yttrium-Aluminum-Garnet) laser. Subject and methods Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er: YAG laser (2.94 mu m at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. Results The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92 +/- 0.80 degrees C for G1, 1.34 +/- 0.86 degrees C for G2, and 0.75 +/- 0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. Conclusion Temperature response to the low and high torque handpieces seemed to be similar, however the Er: YAG laser generated a lower temperature rise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moisture equilibrium data of persimmon pulp powders with 50% maltodextrin (dry basis) obtained with different drying methods were determined at 20, 30, 40 and 50 degrees C. The spray-dryer gave a dry product with a higher adsorption capacity than the other methods. The vacuum- and freeze-dried products had the same adsorption capacity. The highest isosteric heat of sorption was observed for powders produced by spray-drying. The isokinetic temperature (T(B)) calculated for persimmon pulp powder obtained by vacuum-, spray- and freeze-drying were 541.4 K, 616.3 K, 513.2 K, respectively. The sorption process was spontaneous and enthalpy controlled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radicular fractures in permanent teeth are uncommon injuries among dental traumas, comprising 0.5-7% of the cases. Fracture occurs most often in the middle-third of the root and rarely at the apical-third. The present paper reports a clinical case of a horizontal radicular fracture located between the middle- and apical-third of a upper left-central incisor followed-up for over 3 years. The tooth was extracted owing to periodontal reasons. Histomorphologically, it showed pulp-vitality preservation and root healing by hard-tissue deposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From the point of view of deontological ethics, privacy is a moral right that patients are entitled to and it is bound to professional confidentiality. Otherwise, the information given by patients to health professionals would not be reliable and a trustable relationship could not be established. The aim of the present study was to assess, by means of questionnaires with open and closed questions, the awareness and attitudes of 100 dentists working in the city of Andradina, São Paulo State, Brazil, with respect to professional confidentiality in dental practice. Most dentists (91.43%) reported to have instructed their assistants on professional confidentiality. However, 44.29% of the interviewees showed to act contradictorily as reported talking about the clinical cases of their patients to their friends or spouses. The great majority of professionals (98.57%) believed that it is important to have classes on Ethics and Bioethics during graduation and, when asked about their knowledge of the penalties imposed for breach of professional confidentiality, only 48.57% of them declared to be aware of it. Only 28.57% of the interviewees affirmed to have exclusive access to the files; 67.14% reported that that files were also accessed by their secretary; 1.43% answered that their spouses also had access, and 2.86% did not answer. From the results of the present survey, it could be observed that, although dentists affirmed to be aware of professional confidentiality, their attitudes did not adhere to ethical and legal requirements. This stand of health professionals has contributed to violate professional ethics and the law itself, bringing problems both to the professional and to the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the amount of peroxide passage from the pulp chamber to the external enamel surface during the internal bleaching technique. Fifty bovine teeth were sectioned transversally 5 mm below the cemento-enamel junction (CEJ), and the remaining part of the root was sealed with a 2-mm layer of glass ionomer cement. The external surface of the samples was coated with nail varnish, with the exception of standardized circular areas (6-mm diameter) located on the enamel, exposed dentin, or cementum surface of the tooth. The teeth were divided into three experimental groups according to exposed areas close to the CEJ and into two control groups (n=10/group), as follows: GE, enamel exposure area; GC, cementum exposed area; GD, dentin exposed area; Negative control, no presence of internal bleaching agent and uncoated surface; and Positive control, pulp chamber filled with bleaching agent and external surface totally coated with nail varnish. The pulp chamber was filled with 35% hydrogen peroxide (Opalescence Endo, Ultradent). Each sample was placed inside of individual flasks with 1000 mu L of acetate buffer solution, 2 M (pH 4.5). After seven days, the buffer solution was transferred to a glass tube, in which 100 mu L of leuco-crystal violet and 50 mu L of horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to Kruskal-Wallis and Dunn-Bonferroni tests (alpha=0.05). All experimental groups presented passage of peroxide to the external surface that was statistically different from that observed in the control groups. It was verified that the passage of peroxide was higher in GD than in GE (p<0.01). The GC group presented a significantly lower peroxide passage than did GD and GE (p<0.01). It can be concluded that the hydrogen peroxide placed into the pulp chamber passed through the dental hard tissues, reaching the external surface and the periodontal tissue. The cementum surface was less permeable than were the dentin and enamel surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.Methods. Bar-shaped specimens of IA (n = 45) and IZ ( n = 45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively. Data was examined using Weibull statistics. The SCG behavior was described in terms of crack velocity as a function of maximum stress intensity factor (K(Imax)).Results. The Weibull moduli (m = 8) were similar for both ceramics. The characteristic strength (sigma(0)) of IA and IZ was and 466 MPa 550 MPa, respectively. The wet environment significantly increased the SCG of IZ, whereas a less evident effect was observed for IA. In general, both ceramics were prone to SCG, with crack propagation occurring at K(I) as low as 43-48% of their critical K(I). The highest sigma of IZ should lead to longer lifetimes for similar loading conditions.Significance. Water combined with cyclic loading causes pronounced SCG in IZ and IA materials. The lifetime of dental restorations based on these ceramics is expected to increase by reducing their direct exposure to wet conditions and/or by using high content zirconia ceramics with higher strength. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we describe a midsymphyseal distraction osteogenesis treatment with a novel dentally supported appliance. This approach differs from that used in previous reports because the incisors were allowed to move during the distraction procedure. This report shows that midsymphyseal distraction osteogenesis can be used to expand both arches to produce a wider smile. Borderline cases can be treated with this technique without the compromising effects commonly observed with conventional therapy. (Am J Orthod Dentofacial Orthop 2009;135:530-5)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out to determine apparent ileal digestibility (AID) and apparent total tract digestibility (ATTD) of DM, CP, GE, and their respective digestible content of degermed dehulled corn (Zea mays), citrus pulp, and soy (Glycine max) protein concentrate by pigs using the difference method. Thirty-two barrows (28.1 +/- 1.6 kg of BW) were fed a corn-soybean meal basal diet or 1 of 3 diets formulated by replacing 30% of the basal diet with 30% of 1 of the test feedstuffs for 11 d. Chromic oxide (0.3%) was included in the diets. Feces were collected from days 7 to 11 by grab sampling and ileal digesta were collected after pigs were slaughtered on day 12. The AID of DM and AID and ATTD of GE of degermed corn (77.4, 88.7, and 77.7%) were greater (P < 0.05) than those observed in citrus pulp (50.3, 86.5, and 55.8%) and in soy protein concentrate (63.5, 85.1, and 59.4%), which did not differ (P > 0.05). The ATTD of CP, total digestible CP, and total DE of soy protein concentrate (87.5%, 500 g/kg, and 3739 kcal/kg) were higher (P < 0.05) than the values in degermed corn (81.7%, 57.5 g/kg, and 3330 kcal/kg), which were greater (P < 0.05) than those in citrus pulp (60.5%, 39.5 g/kg, and 3223 kcal/kg). Total and ileal digestible DM, AID of CP, and ileal DE of degermed corn (782 g/kg, 673 g/kg, 70.7%, and 2913 kcal/kg) and soy protein concentrate (778 g/kg, 570 g/kg, 78.7%, and 2878 kcal/kg) were similar (P > 0.05) and greater (P < 0.05) than those in citrus pulp (737 g/kg, 436 g/kg, 50.6%, and 2081 kcal/kg). Ileal digestible CP of degermed corn (49.8 g/kg) and citrus pulp (33.0 g/kg) did not differ (P > 0.05) but were smaller (P < 0.05) than the value found in soy protein concentrate (434 g/kg). The DM and energy from degermed corn are more efficiently digested by the pig than those from soy protein concentrate and citrus pulp. Soy protein concentrate was the best protein source evaluated in this study.