974 resultados para Conventional methods
Resumo:
A high definition, finite difference time domain (HD-FDTD) method is presented in this paper. This new method allows the FDTD method to be efficiently applied over a very large frequency range including low frequencies, which are problematic for conventional FDTD methods. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and has been verified against analytical solutions within the frequency range 50 Hz-1 GHz. As an example of the lower frequency range, the method has been applied to the problem of induced eddy currents in the human body resulting from the pulsed magnetic field gradients of an MRI system. The new method only requires approximately 0.3% of the source period to obtain an accurate solution. (C) 2003 Elsevier Science Inc. All rights reserved.
Resumo:
There has been a resurgence of interest in the mean trace length estimator of Pahl for window sampling of traces. The estimator has been dealt with by Mauldon and Zhang and Einstein in recent publications. The estimator is a very useful one in that it is non-parametric. However, despite some discussion regarding the statistical distribution of the estimator, none of the recent works or the original work by Pahl provide a rigorous basis for the determination a confidence interval for the estimator or a confidence region for the estimator and the corresponding estimator of trace spatial intensity in the sampling window. This paper shows, by consideration of a simplified version of the problem but without loss of generality, that the estimator is in fact the maximum likelihood estimator (MLE) and that it can be considered essentially unbiased. As the MLE, it possesses the least variance of all estimators and confidence intervals or regions should therefore be available through application of classical ML theory. It is shown that valid confidence intervals can in fact be determined. The results of the work and the calculations of the confidence intervals are illustrated by example. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
A number of authors concerned with the analysis of rock jointing have used the idea that the joint areal or diametral distribution can be linked to the trace length distribution through a theorem attributed to Crofton. This brief paper seeks to demonstrate why Crofton's theorem need not be used to link moments of the trace length distribution captured by scan line or areal mapping to the moments of the diametral distribution of joints represented as disks and that it is incorrect to do so. The valid relationships for areal or scan line mapping between all the moments of the trace length distribution and those of the joint size distribution for joints modeled as disks are recalled and compared with those that might be applied were Crofton's theorem assumed to apply. For areal mapping, the relationship is fortuitously correct but incorrect for scan line mapping.
Resumo:
There are several competing methods commonly used to solve energy grained master equations describing gas-phase reactive systems. When it comes to selecting an appropriate method for any particular problem, there is little guidance in the literature. In this paper we directly compare several variants of spectral and numerical integration methods from the point of view of computer time required to calculate the solution and the range of temperature and pressure conditions under which the methods are successful. The test case used in the comparison is an important reaction in combustion chemistry and incorporates reversible and irreversible bimolecular reaction steps as well as isomerizations between multiple unimolecular species. While the numerical integration of the ODE with a stiff ODE integrator is not the fastest method overall, it is the fastest method applicable to all conditions.
Resumo:
Background: The heavy usage of coxibs in Australia far outstrips the predicted usage that was based on the treatment of patients with risk factors for upper gastro-intestinal adverse events from conventional anti--inflammatory agents. This raises questions regarding the appropriateness of prescribing. Aims: To determine: (i) the relationship between prescriptions for cyclooxygenase 2 (COX-2) inhibitors and objective evidence of inflammatory arthritis, (ii) prior experience with paracetamol and/or conventional non-steroidal anti-inflammatory drugs (NSAIDs), and (iii) contraindications to the use of NSAIDs. Methods: Drug utilization evaluation and rheumato-logical assessment was conducted on 70 consecutive patients admitted on COX-2 inhibitors to a 480-bed metropolitan hospital. The main outcome measures were: the indication for COX-2 inhibitor; objective -evidence of inflammatory arthritis; previous trial of -paracetamol or conventional NSAIDs; and patient -satisfaction. Results: Only 11 patients (16%) had symptoms or signs of an inflammatory arthropathy, and met Pharmaceut-ical Benefits Schedule criteria for prescribing a COX-2 inhibitor. Fifty-nine patients (84%) had chronic osteo-arthritis, degenerative spinal disease, injury or malignancy, without overt active inflammation. Fourteen patients (20%) had trialled regular paracetamol prior to using any NSAID treatment. Conventional NSAIDs had been previously used by 51 patients (73%). Eleven patients (16%) reported previous adverse gastrointestinal effects from conventional NSAIDs. On the basis of significant renal impairment (creatinine clearance 5/10). Conclusions: Drug utilization data indicate that COX-2 inhibitors are frequently used first line for degenerative osteoarthritis in the absence of overt inflammation, without prior adequate trial of paracetamol and with disregard for the cautions and contraindications of these agents. These findings may explain the unprecedented Pharmaceutical Benefits Schedule expenditure on COX-2 inhibitors in Australia.
Resumo:
In standard cylindrical gradient coils consisting of a single layer of wires, a limiting factor in achieving very large magnetic field gradients is the rapid increase in coil resistance with efficiency. This is a particular problem in small-bore scanners, such as those used for MR microscopy. By adopting a multi-layer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favourable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. Previously this approach has been applied to the design of unshielded, longitudinal, and transverse gradient coils. Here, the multi-layer approach has been extended to allow the design of actively shielded multi-layer gradient coils, and also to produce coils exhibiting enhanced cooling characteristics. An iterative approach to modelling the steady-state temperature distribution within the coil has also been developed. Results indicate that a good level of screening can be achieved in multi-layer coils, that small versions of such coils can yield higher efficiencies at fixed resistance than conventional two-layer (primary and screen) coils, and that performance improves as the number of layers of increases. Simulations show that by optimising multi-layer coils for cooling it is possible to achieve significantly higher gradient strengths at a fixed maximum operating temperature. A four-layer coil of 8 mm inner diameter has been constructed and used to test the steady-state temperature model. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
The aim of this study was to compare accumulated oxygen deficit data derived using two different exercise protocols with the aim of producing a less time-consuming test specifically for use with athletes. Six road and four track male endurance cyclists performed two series of cycle ergometer tests. The first series involved five 10 min sub-maximal cycle exercise bouts, a (V) over dotO(2peak) test and a 115% (V) over dotO(2peak) test. Data from these tests were used to estimate the accumulated oxygen deficit according to the calculations of Medbo et al. (1988). In the second series of tests, participants performed a 15 min incremental cycle ergometer test followed, 2 min later, by a 2 min variable resistance test in which they completed as much work as possible while pedalling at a constant rate. Analysis revealed that the accumulated oxygen deficit calculated from the first series of tests was higher (P< 0.02) than that calculated from the second series: 52.3 +/- 11.7 and 43.9 +/- 6.4 ml . kg(-1), respectively (mean +/- s). Other significant differences between the two protocols were observed for (V) over dot O-2peak, total work and maximal heart rate; all were higher during the modified protocol (P
Resumo:
This article reviews the progress of a personal endeavour to develop chromatography as a quantitative procedure for the determination of reaction stoichiometries and equilibrium constants governing protein interactions. As well as affording insight into an aspect of chromatography with which many protein chemists are unfamiliar, it shows the way in which minor adaptations of conventional chromatographic practices have rendered the technique one of the most powerful methods available for the characterization of interactions. That pathway towards quantification is followed from the introduction of frontal gel filtration for the study of protein self-association to the characterization of ligand binding by the biosensor variant of quantitative affinity chromatography.
Resumo:
Novel nonthermal processes, such as high hydrostatic pressure (HHP), pulsed electric fields (PEFs), ionizing radiation and ultrasonication, are able to inactivate microorganisms at ambient or sublethal temperatures. Many of these processes require very high treatment intensities, however, to achieve adequate microbial destruction in low-acid foods. Combining nonthermal processes with conventional preservation methods enhances their antimicrobial effect so that lower process intensities can be used. Combining two or more nonthermal processes can also enhance microbial inactivation and allow the use of lower individual treatment intensities. For conventional preservation treatments, optimal microbial control is achieved through the hurdle concept, with synergistic effects resulting from different components of the microbial cell being targeted simultaneously. The mechanisms of inactivation by nonthermal processes are still unclear; thus, the bases of synergistic combinations remain speculative. This paper reviews literature on the antimicrobial efficiencies of nonthermal processes combined with conventional and novel nonthermal technologies. Where possible, the proposed mechanisms of synergy is mentioned. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
As perdas pós-colheita de frutas promovem a elevação do custo dos produtos e diminuem a oferta ao consumidor. Suas principais causas estão na colheita, transporte e armazenamento inadequados. A aplicação de revestimentos comestíveis juntamente com a redução da temperatura de armazenamento constitui um dos métodos empregados para a conservação pós-colheita de produtos com vida útil curta, como frutas e hortaliças. O morango é um fruto consumido preferencialmente in natura. Desta forma, torna-se promissora a utilização de revestimento comestível para aumentar seu período de armazenamento e comercialização, sem alteração do sabor, da cor e do aroma dos frutos. A produção orgânica frente a convencional de frutos podem apresentar diferenças, sendo interessante o estudo envolvendo as formas de cultivo. Este estudo teve como objetivo avaliar a conservação pós-colheita de morangos cv. Camarosa, oriundos de cultivo orgânico e convencional revestidos com coberturas comestíveis. Os morangos foram revestidos com fécula de mandioca, gelatina e cera de carnaúba, armazenados durante 10 dias a 10 ºC. A cada 2 dias de armazenamento foram determinados perda de massa, sólidos solúveis, pH, acidez titulável, firmeza, antocianinas totais e podridão fúngica. Análise sensorial foi realizada para verificar a aceitação dos morangos e para avaliar a influência da informação nesta aceitação. A perda de massa foi maior no cultivo orgânico a partir do 8º dia de armazenamento, chegando a 11,47% contra 8,88% do cultivo convencional no final do 10º dia de armazenamento. O revestimento que possibilitou menor perda de massa foi o de cera de carnaúba em relação ao controle. A contaminação fúngica iniciou-se no 4º dia de armazenamento em ambos os tipos de cultivo. No 8º dia de armazenamento observou-se diferenças na podridão entre os tipos de cultivo, sendo o orgânico visualmente mais contaminado. O revestimento de cera de carnaúba apresentou menor podridão fúngica em relação aos outros revestimentos, porém não diferiu da amostra controle. Das variáveis físico-químicas avaliadas, apenas o teor de sólidos solúveis apresentou diferenças entre os tipos de cultivo, sendo o morango convencional o que obteve maiores valores. O teor de antocianinas dos morangos revestidos com fécula de mandioca diferiu do controle, porém o revestimento com fécula não diferiu dos revestidos com gelatina e cera de carnaúba. Foram verificadas diferenças na firmeza dos frutos em relação aos revestimentos. Ao longo do tempo foi observado diferenças no pH, teor de antocianinas e firmeza. O revestimento com cera de carnaúba se mostrou mais adequado em relação aos demais revestimentos, porém sua aparência mostrou-se com pouco brilho e esbranquiçado. Os frutos avaliados apresentaram vida útil pós-colheita de aproximadamente 6 dias. Os morangos, do ponto de vista microbiológico, se mostraram aptos para consumo. A aceitação dos morangos foi boa, não tendo ix diferenças significativas entre morango orgânico e convencional. O fornecimento da informação de “morango orgânico” e a apresentação de um texto adicional informativo não influenciaram na aceitação dos morangos. Entre os revestimentos testados o de cera de carnaúba se mostrou mais aplicável, os demais nas condições testadas não mostraram bons resultados.
Resumo:
The increased preference for minimally processed vegetables has been attributed to the health benefits associated with fresh produce and the demand for ready-to-eat salads. In this paper, lettuce (Lactuca sativa L.) was evaluated for the effects of different cropping systems on the respiratory properties. Lettuce was packaged in low density polyethylene bags and stored in a refrigerator at 4 ºC. The concentration of carbon dioxide and oxygen inside the package was monitored during the storage at zero, three, six, eight, ten and twelve days by gas chromatography. Dry matter variation was measured gravimetrically up to day fourteen of storage. Values of respiratory rate for conventional lettuce increased from day 1 to 3 and remained low, while respiratory rate of the organic lettuce increased three-fold up to day 8, stabilizing at a high level. Variation in dry matter during storage also resulted from differences between the two cultivation systems. The highest content of dry matter was achieved by organic lettuce.
Resumo:
A numerical comparison is performed between three methods of third order with the same structure, namely BSC, Halley’s and Euler–Chebyshev’s methods. As the behavior of an iterative method applied to a nonlinear equation can be highly sensitive to the starting points, the numerical comparison is carried out, allowing for complex starting points and for complex roots, on the basins of attraction in the complex plane. Several examples of algebraic and transcendental equations are presented.