979 resultados para Computed tomography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA® in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Descrever os principais achados de imagem em uma série de casos de tumores neuroendócrinos primários do pulmão (TNPs), destacando as alterações na tomografia computadorizada. MATERIAIS E MÉTODOS: Exames de 22 pacientes (12 homens, idade média de 60 anos) avaliados nos últimos cinco anos em nosso serviço, com confirmação histopatológica, foram retrospectivamente revistos por dois médicos radiologistas e os achados foram descritos em consenso, focando as alterações tomográficas. RESULTADOS: Descrevemos 5 carcinoides típicos, 3 carcinoides atípicos, 3 carcinomas neuroendócrinos de grandes células (CNGCs) e 11 cânceres pulmonares de pequenas células (CPPCs). Apenas um carcinoide típico apresentou aspecto característico de nódulo endobrônquico central com atelectasia pulmonar distal, enquanto os demais foram nódulos ou massas pulmonares. Os carcinoides atípicos eram massas pulmonares periféricas e heterogêneas. Um CNGC era massa periférica delimitada e homogênea, enquanto os demais eram mal delimitados e heterogêneos. Os 11 CPPCs eram massas centrais, infiltrativas e heterogêneas, com alterações pleuropulmonares secundárias. Calcificações estavam ausentes nos CNGCs e CPPCs. Metástases foram vistas inicialmente ou no seguimento de todos os CNGCs e CPPCs. CONCLUSÃO: Apesar de alguns aspectos semelhantes nos exames de imagem, os achados radiológicos, quando integrados às informações clínicas, podem constituir critérios importantes na diferenciação dos tipos histológicos de TNPs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tumores miofibroblásticos inflamatórios raramente acometem vias urinárias ou crianças, comumente mimetizando neoplasias malignas nos exames de imagem. Foram descritos apenas 35 casos desses tumores na bexiga de crianças, segundo a literatura recente. Os autores apresentam o caso de uma criança com um tumor miofibroblástico vesical que evoluiu favoravelmente após ressecção cirúrgica completa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a PET/CT na abordagem de pacientes com câncer de cabeça e pescoço. MATERIAIS E MÉTODOS: Estudo retrospectivo de 63 prontuários e exames de PET/CT de pacientes com câncer de cabeça e pescoço. RESULTADOS: Foram encontradas alterações em 76% dos exames. Destes, 7 (11%) foram considerados falso-positivos, com SUV < 5,0. A PET/CT mostrou-se negativa em 15 situações (24%). Dos 14 casos nos quais se utilizou o exame para estadiamento, em 3 (22%) houve aumento no estadiamento. CONCLUSÃO: A PET/CT mostra-se como exame de potencial valor na rotina de avaliação de pacientes com câncer de cabeça e pescoço, entretanto, necessitamos de maior número de casos para definirmos protocolo de uso.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the diagnosis of Graves' orbitopathy is primarily made clinically based on laboratory tests indicative of thyroid dysfunction and autoimmunity, imaging studies, such as computed tomography, magnetic resonance imaging, ultrasound and color Doppler imaging, play an important role both in the diagnosis and follow-up after clinical or surgical treatment of the disease. Imaging studies can be used to evaluate morphological abnormalities of the orbital structures during the diagnostic workup when a differential diagnosis versus other orbital diseases is needed. Imaging may also be useful to distinguish the inflammatory early stage from the inactive stage of the disease. Finally, imaging studies can be of great help in identifying patients prone to develop dysthyroid optic neuropathy and therefore enabling the timely diagnosis and treatment of the condition, avoiding permanent visual loss. In this paper, we review the imaging modalities that aid in the diagnosis and management of Graves' orbitopathy, with special emphasis on the diagnosis of optic nerve dysfunction in this condition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Micelles composed of amphiphilic copolymers linked to a radioactive element are used in nuclear medicine predominantly as a diagnostic application. A relevant advantage of polymeric micelles in aqueous solution is their resulting particle size, which can vary from 10 to 100 nm in diameter. In this review, polymeric micelles labeled with radioisotopes including technetium (99mTc) and indium (111In), and their clinical applications for several diagnostic techniques, such as single photon emission computed tomography (SPECT), gamma-scintigraphy, and nuclear magnetic resonance (NMR), were discussed. Also, micelle use primarily for the diagnosis of lymphatic ducts and sentinel lymph nodes received special attention. Notably, the employment of these diagnostic techniques can be considered a significant tool for functionally exploring body systems as well as investigating molecular pathways involved in the disease process. The use of molecular modeling methodologies and computer-aided drug design strategies can also yield valuable information for the rational design and development of novel radiopharmaceuticals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Primary lung lymphoma is a rare entity accounting for approximately 0.3% of all primary neoplasia of the lung and includes diffuse large B-cell lymphoma (DLBL) and lymphomatoid granulomatosis (LYG). Considering that clinical features may be similar, whereas epidemiology, morphology, and radiological features are different, the authors report a case of a middle-aged man who presented multiple pulmonary nodules in the lower lobes and groundglass opacities scattered bilaterally on computed tomography. Clinically, he presented a consumptive syndrome with respiratory failure and pleurisy, which progressed until death. The autopsy findings were consistent with lymphomatoid granulomatosis (LYG) grade 3/ diffuse large B-cell lymphoma (DLBL). The authors call attention to the difficulty of establishing an accurate diagnosis, mainly when the demonstration of EBV-infected atypical B-cells fails.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Angiomyolipomas (AMLs) are mesenchymal neoplasms, named so because of the complex tissue composition represented by variable proportions of mature adipose tissue, smooth muscle cells, and dysmorphic blood vessels. Although AMLs may rise in different sites of the body, they are mostly observed in the kidney and liver. In the case of renal AMLs, they are described in two types: isolated AMLs and AMLs associated with tuberous sclerosis (TS). While most cases of AMLs are found incidentally during imaging examinations and are asymptomatic, others may reach huge proportions causing symptoms. Pulmonary lymphangioleiomyomatosis (LAM) is a rare benign disease characterized by cystic changes in the pulmonary parenchyma and smooth muscle proliferation, leading to a mixed picture of interstitial and obstructive disease. AML and LAM constitute major features of tuberous sclerosis complex (TSC), a multisystem autosomal dominant tumor-suppressor gene complex diagnosis. The authors report the case of a young female patient who presented a huge abdominal tumor, which at computed tomography (CT) show a fat predominance. The tumor displaced the right kidney and remaining abdominal viscera to the left. Chest CT also disclosed pulmonary lesions compatible with lymphangioleiomyomatosis. Because of sudden abdominal pain accompanied by a fall in the hemoglobin level, the patient underwent an urgent laparotomy. The excised tumor was shown to be a giant renal AML with signs of bleeding in its interior. The authors call attention to the diagnosis of AML and the huge proportions that the tumor can reach, as well as for ruling out the TSC diagnosis, once it may impose genetic counseling implications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The repair of large bone defects is a major orthopedic challenge because autologous bone grafts are not available in large amounts and because harvesting is often associated with donor-site morbidity. Considering that bone marrow stromal cells (BMSC) are responsible for the maintenance of bone turnover throughout life, we investigated bone repair at a site of a critically sized segmental defect in sheep tibia treated with BMSCs loaded onto allografts. The defect was created in the mid-portion of the tibial diaphysis of eight adult sheep, and the sheep were treated with ex-vivo expanded autologous BMSCs isolated from marrow aspirates and loaded onto cortical allografts (n = 4). The treated sheep were compared with control sheep that had been treated with cell-free allografts (n = 4) obtained from donors of the same breed as the receptor sheep. Results: The healing response was monitored by radiographs monthly and by computed tomography and histology at six, ten, fourteen, and eighteen weeks after surgery. For the cell-loaded allografts, union was established more rapidly at the interface between the host bone and the allograft, and the healing process was more conspicuous. Remodeling of the allograft was complete at 18 weeks in the cell-treated animals. Histologically, the marrow cavity was reestablished, with intertrabecular spaces being filled with adipose marrow and with evidence of focal hematopoiesis. Conclusions: Allografts cellularized with AOCs (allografts of osteoprogenitor cells) can generate great clinical outcomes to noncellularized allografts to consolidate, reshape, structurally and morphologically reconstruct bone and bone marrow in a relatively short period of time. These features make this strategy very attractive for clinical use in orthopedic bioengineering

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Congenital cytomegalovirus (CMV) infection may lead to cerebral injury and neurodevelopmental delay. Cranial computed tomography (CT) is currently the standard imaging technique for predicting the outcome of CMV infected patients. Ultrasound (US) is a safe means to assess the extent of cerebral injury due to CMV infection in neonates, and unlike CT, is readily available at the bedside. Aim: To report the accuracy of US in predicting neurodevelopmental and sensorineural outcome in patients with congenital CMV infection. Study design: 57 newborns with congenital CMV infection underwent brain US and were followed prospectively for motor skills, developmental quotient and hearing function. Results: An abnormal US was found in 12/57 newborns. At least one sequela (Developmental Quotient < 85, motor delay, sensorineural hearing loss) was present in 10/11 surviving children with abnormal US (1 patient died in the neonatal period) vs 3/45 newborns with normal US (OR for death or poor outcome: 154, CI 17.3-1219.6, p<0.001, positive predictive value 91.7%, negative predictive value 93.3%). Conclusion: A good correlation is shown between ultrasound abnormalities and the prediction of outcome, suggesting that US may be used to study and follow CMV infected neonates. Our findings await confirmation in a larger population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis is a part of a larger study about the characterization of mechanical and histomorphometrical properties of bone. The main objects of this study were the bone tissue properties and its resistance to mechanical loads. Moreover, the knowledge about the equipment selected to carry out the analyses, the micro-computed tomography (micro-CT), was improved. Particular attention was given to the reliability over time of the measuring instrument. In order to understand the main characteristics of bone mechanical properties a study of the skeletal, the bones of which it is composed and biological principles that drive their formation and remodelling, was necessary. This study has led to the definition of two macro-classes describing the main components responsible for the resistance to fracture of bone: quantity and quality of bone. The study of bone quantity is the current clinical standard measure for so-called bone densitometry, and research studies have amply demonstrated that the amount of tissue is correlated with its mechanical properties of elasticity and fracture. However, the models presented in the literature, including information on the mere quantity of tissue, have often been limited in describing the mechanical behaviour. Recent investigations have underlined that also the bone-structure and the tissue-mineralization play an important role in the mechanical characterization of bone tissue. For this reason in this thesis the class defined as bone quality was mainly studied, splitting it into two sub-classes of bone structure and tissue quality. A study on bone structure was designed to identify which structural parameters, among the several presented in the literature, could be integrated with the information about quantity, in order to better describe the mechanical properties of bone. In this way, it was also possible to analyse the iteration between structure and function. It has been known for long that bone tissue is capable of remodeling and changing its internal structure according to loads, but the dynamics of these changes are still being analysed. This part of the study was aimed to identify the parameters that could quantify the structural changes of bone tissue during the development of a given disease: osteoarthritis. A study on tissue quality would have to be divided into different classes, which would require a scale of analysis not suitable for the micro-CT. For this reason the study was focused only on the mineralization of the tissue, highlighting the difference between bone density and tissue density, working in a context where there is still an ongoing scientific debate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the marine Jurassic deposits of Europe, a group of marine crocodilians, the Thalattosuchia, belongs to the frequently found reptiles. Thalattosuchia are widely spread in Central Europe from the Jurassic to Lower Cretaceous, and some taxa are also distributed worldwide. The task of the work was to examine all taxa known from the Liassic of Europe. The most frequently known taxa Steneosaurus bollensis and Pelagosaurus typus are anatomically revised. New discoveries at the skull of Pelagosaurus typus e.g., the fact of a partly paired frontal are described by means of computed tomography investigations. In addition, juvenile specimens of this taxon are studied in detail for the first time. The rarely occurring taxon Platysuchus multiscrobiculatus is anatomically described in detail for the first time. It shows both in the skull and in the postcranial material morphological differences to Steneosaurus bollensis and Pelagosaurus typus. Thus Pl. multiscrobiculatus possesses, e.g., an ilium with a deeper acetabulum and a femur with a distinctly flexed femoral head. A juvenile specimen of Pl. multiscrobiculatus is now discovered and is described in parts for the first time, too. Furthermore, Steneosaurus gracilirostris and Steneosaurus brevior known from Lower Jurassic deposits of England are examined and in parts revised. In this work, Steneosaurs brevior is discovered with one specimen from the Upper Liassic of Holzmaden, Germany for the first time, and provides new evidence for the palaeobiogeographical distribution of the taxon. Because of the high number of investigated specimens, it is possible to study ontogenetic development from juvenile to adult stage in Steneosaurus bollensis, Pelagosaurus typus, and Platysuchus multiscrobiculatus. Biometric data are collected from thalattosuchians and extant crocodilians (e.g. Gavialis gangeticus) to investigate intraspecific variation, ontogenetic development, and taxa differentiation. The skulls of Platysuchus multiscrobiculatus and Steneosaurus bollensis are reconstructed three-dimensionally as wax models. The skull reconstructions form the basis of the jaw muscle restoration of Steneosaurus bollensis in connection with comparative studies at extant crocodilians. By means of functional morphologic analysis of the jaw musculature, the dentition, and the locomotor system of S. bollensis, possible conclusions are drawn for the prey options and the hunting behaviour. To clarify the relationships within the Thalattosuchia, a computer-based cladistic phylogenetic in-group analyse of 25 Thalattosuchia taxa is performed. For the analysis, following Thalattosuchia taxa are studied likewise at original material for comparisons: Metriorhynchus superciliosus, Metriorhynchus hastifer, Metriorhynchus leedsi, Geosaurus gracilis, Geosaurus giganteus, Teleidosaurus calvadosi, Teleidosaurus gaudryi, Teleosaurus cadomensis, Teleosaurus geoffroyi, Steneosaurus priscus, Steneosaurus edwardsi, Steneosaurus heberti, Steneosaurus leedsi, Steneosaurus boutilieri, Steneosaurus megarhinus, Steneosaurus obtusidens, and Machimosaurus hugii. The phylogenetic in-group analyse based on 115 characters, reveals a sister-group relationship of the monophyletic Teleosauridae and monophyletic Metriorhynchidae. Within the groups, some taxa are probably paraphyletic. The taxon Pelagosaurus typus is nested inside the Teleosauridae and not outside or within the Metriorhynchidae, as many authors suggested it so far. Based on these results, a tentative palaeobiogeographical-evolutionary scenario is developed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die zuverlässige Berechnung von quantitativen Parametern der Lungenventilation ist für ein Verständnis des Verhaltens der Lunge und insbesondere für die Diagnostik von Lungenerkrankungen von großer Bedeutung. Nur durch quantitative Parameter sind verlässliche und reproduzierbare diagnostische Aussagen über den Gesundheitszustand der Lunge möglich. Im Rahmen dieser Arbeit wurden neue quantitative Verfahren zur Erfassung der Lungenventilation basierend auf der dynamischen Computer- (CT) und Magnetresonanztomographie (MRT) entwickelt. Im ersten Teil dieser Arbeit wurde die Frage untersucht, ob das Aufblähen der Lunge in gesunden Schweinelungen und Lungen mit Akutem Lungenversagen (ARDS) durch einzelne, diskrete Zeitkonstanten beschrieben werden kann, oder ob kontinuierliche Verteilungen von Zeitkonstanten die Realität besser beschreiben. Hierzu wurden Serien dynamischer CT-Aufnahmen während definierter Beatmungsmanöver (Drucksprünge) aufgenommen und anschließend aus den Messdaten mittels inverser Laplace-Transformation die zugehörigen Verteilungen der Zeitkonstanten berechnet. Um die Qualität der Ergebnisse zu analysieren, wurde der Algorithmus im Rahmen von Simulationsrechnungen systematisch untersucht und anschließend in-vivo an gesunden und ARDS-Schweinelungen eingesetzt. Während in den gesunden Lungen mono- und biexponentielle Verteilungen bestimmt wurden, waren in den ARDS-Lungen Verteilungen um zwei dominante Zeitkonstanten notwendig, um die gemessenen Daten auf der Basis des verwendeten Modells verlässlich zu beschreiben. Es wurden sowohl diskrete als auch kontinuierliche Verteilungen gefunden. Die CT liefert Informationen über das solide Lungengewebe, während die MRT von hyperpolarisiertem 3He in der Lage ist, direkt das eingeatmete Gas abzubilden. Im zweiten Teil der Arbeit wurde zeitlich hochaufgelöst das Einströmen eines 3He-Bolus in die Lunge erfasst. Über eine Entfaltungsanalyse wurde anschließend das Einströmverhalten unter Idealbedingungen (unendlich kurzer 3He-Bolus), also die Gewebeantwortfunktion, berechnet und so eine Messtechnik-unabhängige Erfassung des Einströmens von 3He in die Lunge ermöglicht. Zentrale Fragestellung war hier, wie schnell das Gas in die Lunge einströmt. Im Rahmen von Simulationsrechnungen wurde das Verhalten eines Entfaltungsalgorithmus (basierend auf B-Spline Repräsentationen) systematisch analysiert. Zusätzlich wurde ein iteratives Entfaltungsverfahren eingesetzt. Aus zeitlich hochaufgelösten Messungen (7ms) an einer gesunden und einer ARDS-Schweinelunge konnte erstmals nachgewiesen werden, dass das Einströmen in-vivo in weniger als 0,1s geschieht. Die Ergebnisse zeigen Zeitkonstanten im Bereich von 4ms–50ms, wobei zwischen der gesunden Lungen und der ARDS-Lunge deutliche Unterschiede beobachtet wurden. Zusammenfassend ermöglichen daher die in dieser Arbeit vorgestellten Algorithmen eine objektivere Bestimmung quantitativer Parameter der Lungenventilation. Dies ist für die eindeutige Beschreibung ventilatorischer Vorgänge in der Lunge und somit für die Lungendiagnostik unerlässlich. Damit stehen quantitative Methoden für die Lungenfunktionsdiagnostik zur Verfügung, deren diagnostische Relevanz im Rahmen wissenschaftlicher und klinischer Studien untersucht werden kann.