949 resultados para Capillary tubes
Resumo:
Background: Cardiovascular risk functions fail to identify more than 50% of patients who develop cardiovascular disease. This is especially evident in the intermediate-risk patients in which clinical management becomes difficult. Our purpose is to analyze if ankle-brachial index (ABI), measures of arterial stiffness, postprandial glucose, glycosylated hemoglobin, self-measured blood pressure and presence of comorbidity are independently associated to incidence of vascular events and whether they can improve the predictive capacity of current risk equations in the intermediate-risk population. Methods/Design: This project involves 3 groups belonging to REDIAPP (RETICS RD06/0018) from 3 Spanish regions. We will recruit a multicenter cohort of 2688 patients at intermediate risk (coronary risk between 5 and 15% or vascular death risk between 3-5% over 10 years) and no history of atherosclerotic disease, selected at random. We will record socio-demographic data, information on diet, physical activity, comorbidity and intermittent claudication. We will measure ABI, pulse wave velocity and cardio ankle vascular index at rest and after a light intensity exercise. Blood pressure and anthropometric data will be also recorded. We will also quantify lipids, glucose and glycosylated hemoglobin in a fasting blood sample and postprandial capillary glucose. Eighteen months after the recruitment, patients will be followed up to determine the incidence of vascular events (later follow-ups are planned at 5 and 10 years). We will analyze whether the new proposed risk factors contribute to improve the risk functions based on classic risk factors. Discussion: Primary prevention of cardiovascular diseases is a priority in public health policy of developed and developing countries. The fundamental strategy consists in identifying people in a high risk situation in which preventive measures are effective and efficient. Improvement of these predictions in our country will have an immediate, clinical and welfare impact and a short term public health effect
Resumo:
This work reports the analysis of inorganic and organic contaminants in alcohol fuel samples using capillary electrophoresis. Chloride and sulfate were analyzed in nitrate/ monochloroacetic acid at 10 mmol L-1 concentration each under indirect UV detection (210 nm). The analysis of aldehydes is based on the 216 nm detection of 3-methyl-2-benzothiazoline hydrazone adducts. The running buffer consisted of 20 mmol L-1 tetraborate , 40 mmol L-1 sodium dodecyl sufate and 12 mmol L-1 beta-ciclodextrin. Both methodologies were applied to real samples indicating inorganic ion concentrations from 0.15 to 6.64 mg kg-1 and aldehydes from 32.0 to 91.3 mg L-1.
Resumo:
Fumonisins are mycotoxins occurring worldwide, mainly in maize and maize-based food products, which could affect animal and human health. This paper reviews analytical methodologies for the determination of these fungal toxins in foods. It includes extraction, cleanup, derivatization procedures, detection, quantification, and confirmation procedures. Initial attempts at gas chromatographic methods and thin layer chromatography were supplanted by liquid chromatographic methods, mainly performed with fluorometric detection, or mass spectrometry detection, enabling the analysis of polar and thermolabile chemicals without chemical derivatization, which results in lower limits of detection. Alternative methods, such as enzyme linked immunosorbent assay or zone capillary zone electrophoresis, are also described.
Resumo:
Engineering and pricing of large recovery boiler were studied in this work. Engineering was carried out with Anita 4.2 which is an engineering program of Andritz. Key initial values were chosen with previous studies. Primary target of this work was to find out the consequences that furnace dimensions and furnace screen vertical part has to boiler pricing. Boilers that were engineered had different rate of furnace width and depth and different heat transfer plate count. Boiler balances were invariable. Boilers with different vertical screen construction were also calculated. First variation was boiler with vertical screen up to furnace roof. Other variation was to connect vertical screen to Pre-boiler generating bank inlet tubes. Total prices were calculated to engineered boilers. Pricing was sort out to heat transfers, high pressure pipes, steel structures, auxiliary equipments and civil/structural costs. This study did not notice parts of the boiler which costs do not vary with the construction of the boiler. Heat transfers had the largest share of costs. Boiler building had the most significant differences between the boilers. Furnace screen had also significant role especially to costs of the boiler building.
Resumo:
Monolithic stationary phases represent a new generation of chromatographic separation media. These phases consist of a continuous separation bed prepared by in situ polymerization or consolidation inside the column tubing. In recent years, their simple preparation procedure, unique properties and excellent performance have attracted quite remarkable attention in liquid chromatography and capillary electrochromatography. This review summarizes the preparation, characterization and applications of monolithic stationary phases. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different separation modes.
Resumo:
This paper focuses: (i) the development of a measurement technique for the determination of atmospheric C2-C6 hydrocarbons with sampling in canisters and analysis by gas chromatography/flame ionisation detector (GC/FID), (ii) the improvement of an existent adsorption-sampling technique with Tenax TA tubes for the determination of C6-C11 hydrocarbons and analysis by GC/FID after thermal desorption and cryogenic concentration, (iii) the identification of compounds present in ambient air by gas chromatography/mass spectrometry (GC/MS) for both canister and Tenax samples, (iv) a program of interlaboratorial comparison for quality control of C2-C11 analyses, and (v) the seasonal characterisation of ambient air C2-C11 hydrocarbons.
Resumo:
The essential oil isolated by hydrodistillation from flowers and root bark of Gochnatia polymorpha (Less) Cabr. ssp floccosa Cabr. (Asteraceae) was analyzed by capillary GC/MS. Thirty components were identified in oil of flowers. The composition depends on the stage of flowering. At the beginning of flowering, the main components were (E)-nerolidol (20,4%) and eugenol (17,9%) whereas at the end they were phenylacetaldehyde (14,6%) and tricosane (12,0%). In the essential oil of root bark ten sesquiterpenes were identified. The major components were beta-bisabolene (31,0%) and beta-bisabolol (21,5%). This paper describes for the first time the composition of essential oil in the genus Gochnatia.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.
Resumo:
This is a contribution that presents a translation of the work "Terminology for Analytical Capillary Electromigration Techniques" by Riekkola and collaborators (Pure Appl. Chem., Vol. 76, No. 2, 443-451, 2004) from IUPAC© for the Portuguese Language. Additional terms that had not been defined in native Portuguese were included for the benefit of the local community. Additional notes were also included to clarify some important concepts and to highlight the differences between techniques.
Resumo:
The supply of drinking water in the Metropolitan Area of São Paulo City has been a great and serious challenge in the latest years. This work demonstrates the viability of the evaluation of the degree of contamination of the water reservoirs using analytical procedures, which allow the analysis of several compounds at relatively low cost: stripping square wave voltammetry (SSWV) and capillary zone electrophoresis with contactless conductivity detection (CZE-CCD). The results of ionic composition indicated significant contamination of the Guarapiranga water system by human activities on the reservoir banks. In fact, the Guavirutuba and Itupu streams presented high concentrations of phosphate and ammonium ions. This can be directly related to misuse and unruled occupation of the soil and precarious sanitary infrastructure.
Resumo:
Destruction of Padron® (dye and picloram) was evaluated using a photoreactor and a solar reactor. Photolysis was observed using only a germicide lamp (GL). Black light (BL) and H2O2 (172 mmol L-1) promoted a conversion of 49% and 6% of dye and picloram, respectively. Photocatalytic processes were more efficient using TiO2/GL (96%-dye; 60%-picloram) than TiO2/BL (44%-dye; 40%-picloram). Photolysis using sunlight was not observed during PadronÒ recirculation in the reactor constructed with four borosilicate tubes. Meanwhile, adding H2O2 resulted in 12% conversion of dissolved organic compounds. Finally, the most efficient mineralization (60%) was obtained using the Fenton reaction ( H2O2-176 mmol L-1; FeSO4x6H2O-90 mmol L-1) and sunlight.
Resumo:
The essential oils from leaves (sample A) and flowers (sample B) of Aeolanthus suaveolens Mart. ex Spreng were obtained by hydrodistillation and analyzed by GC, GC-MS, and chiral phase gas chromatography (CPGC). Six compounds have been identified from the essential oils, representing ca 94.3 and 93% of the oils corresponding to samples A and B, respectively. The major constituents of samples A and B essential oils were respectively, linalool (34.2%/34.9%), (-)-massoialactone (25.9%/17.0%) and (E)-beta-farnesene (25.4%/29.1%). The enantiomeric distribution of the monoterpene linalool was established by analysis on heptakis- (6-O-methyl-2,3-di-O-pentyl)-beta-cyclodextrin capillary column. The antimicrobial activity of the essential oil from leaves and isolated compounds was also evaluated.
Resumo:
Un dels problemes típics de regulació en el camp de l’automatització industrial és el control de velocitat lineal d’entrada del fil a les bobines, ja que com més gruix acumulem a igual velocitat de rotació de la bobina s’augmenta notablement la velocitat lineal d’entrada del fil, aquest desajust s’ha de poder compensar de forma automàtica per aconseguir una velocitat d’entrada constant. Aquest problema de regulació de velocitats és molt freqüent i de difícil control a la indústria on intervé el bobinat d’algun tipus de material com cablejat, fil, paper, làmines de planxa, tubs, etc... Els dos reptes i objectius principals són, primer, la regulació de la velocitat de rotació de la bobina per aconseguir una velocitat lineal del fil d’entrada, i segon, mitjançant el guiatge de l’alimentació de fil a la bobina, aconseguir un repartiment uniforme de cada capa de fil. El desenvolupament consisteix amb l’automatització i control d’una bobinadora automàtica mitjançant la configuració i programació de PLC’s, servomotors i encoders. Finalment es farà el muntatge pràctic sobre una bancada per verificar i simular el seu correcte funcionament que ha de donar solució a aquests problemes de regulació de velocitats. Com a conclusions finals s’han aconseguit els objectius i una metodologia per fer una regulació de velocitats de rotació per bobines, amb accionaments de servomotors amb polsos, i a nivell de coneixements he aconseguit dominar les aplicacions d’aquest tipus d’accionaments aplicats a construccions mecàniques.
Resumo:
Työn tarkoituksena oli löytää kapillaarielektroforeesimenetelmä (CE), joka soveltuisi metallien neste-nesteuutossa käytettävien orgaanisten uuttofaasien koostumuksen analysointiin. Kapillaarielektroforeesissa käytetyn elektrolyyttiliuoksen analyytti-kohtaista optimointia ei tässä työssä tehty, vaan liikkeelle lähdettiin fenoleille tarkoitetulla menetelmällä. Tarkasteltavia uuttoreagenssiryhmiä olivat hydroksi-oksiimit sekä fosfiinihappo- ja fosforihappopohjaiset reagenssit. Tutkittavia kaupallisia laimentimia olivat Orfom SX 11 ja Shellsol D70. Lisäksi tutkittiin kahta modifiointiainetta, TOPOa (tri-n-oktyylifosfiinioksidi) ja TXIB:tä (2,2,4-trimetyyli-1,3-pentaanidiolidi-isobutyraatti). Työssä tavoiteltiin kapillaarielektroforeesin hyötyjä erityisesti hydrometallurgisessa teollisuudessa. Suurimpana hyötynä ennakoitiin mahdollisuus analysoida suuria molekyylejä, kuten uuttoreagenssi-metallikomplekseja, joita ei pystytä analysoimaan kaasukromatografilla (GC). Näytteet voidaan myös analysoida ilman hidasta ja usein ei-kvantitatiivista derivatisointia. Kirjallisuudesta ei löytynyt aiempia artikkeleita CE:n soveltamisesta kyseisille aiheille. Kapillaarielektroforeesianalyyseissa pystyttiin esimerkiksi havaitsemaan hydroksi-oksiimin kuparikompleksi orgaanisessa faasissa. Seulonta-ajoissa yleisenä ongelmana oli kuitenkin tulosten heikko toistettavuus. Kapillaari-elektro-foreesi-menetelmä tarjoaa selvästi mahdollisuuksia tulevaisuudessa, mutta vielä sillä ei päästy luotettavaan toistoon sähkökentän häiriöiden ja elektrolyyttiliuoksen riittämättömän optimoinnin vuoksi. Lisäksi teollisissa olosuhteissa käytetyille autenttisille hydroksioksiimi- ja fosfiinihapponäytteille tehtiin perinteisiä kaasukromatografia-analyysejä, joiden perusteella voitiin nähdä uuttofaasin koostumuksen muuttuneen prosessissa. Hapettuminen sekä eri hydrolyysireaktiot ovat tärkeimmät syyt reagenssien ja laimentimien muuttumiselle. Näitä hajoamistuotteita ei tässä työssä onnistuttu analysoimaan kapillaarielektroforeesilla.