934 resultados para CO2 release
Resumo:
There is evidence that serotonin [ 5- hydroxytryptamine ( 5- HT)] is involved in the physiological responses to hypercapnia. Serotonergic neurons represent the major cell type ( comprising 15 - 20% of the neurons) in raphe magnus nucleus ( RMg), which is a medullary raphe nucleus. In the present study, we tested the hypothesis 1) that RMg plays a role in the ventilatory and thermal responses to hypercapnia, and 2) that RMg serotonergic neurons are involved in these responses. To this end, we microinjected 1) ibotenic acid to promote nonspecific lesioning of neurons in the RMg, or 2) anti- SERT- SAP ( an immunotoxin that utilizes a monoclonal antibody to the third extracellular domain of the serotonin reuptake transporter) to specifically kill the serotonergic neurons in the RMg. Hypercapnia caused hyperventilation and hypothermia in all groups. RMg nonspecific lesions elicited a significant reduction of the ventilatory response to hypercapnia due to lower tidal volume ( V-T) and respiratory frequency. Rats submitted to specific killing of RMg serotonergic neurons showed no consistent difference in ventilation during air breathing but had a decreased ventilatory response to CO2 due to lower VT. The hypercapnia- induced hypothermia was not affected by specific or nonspecific lesions of RMg serotonergic neurons. These data suggest that RMg serotonergic neurons do not participate in the tonic maintenance of ventilation during air breathing but contribute to the ventilatory response to CO2. Ultimately, this nucleus may not be involved in the thermal responses CO2.
Resumo:
In this study we analyzed possible damages that vaporization from laser radiation could cause to implant material. Fifteen standard titanium implants, measuring 3.75 mm in diameter by 7 mm in length, were placed into the upper and lower jaws of three dogs according to Branemark's system. After osseointegration, all implants were exposed. In group I (control) conventional exposure with a punch was used; in group II, a CO2 laser with 2 W (power density: 256 W/cm(2); fluency: 0.077 J/cm(2), and a pulse mode of 0.30 ms) was used, and in group III 4 W (power density: 512 W/cm(2), fluency: 0.154 J/cm(2), and a pulse mode of 0.30 ms) was used. After vaporization, the cover screws were removed and sent for metallographic examination. The results showed that cover screws irradiated with 2 and 4 W power caused no superficial or microstructural alteration. The results also showed that the prescribed power densities, fluencies, and the use of the pulse mode were suitable for exposing implants without damage to tissue or implant material. (C) 2002 Laser Institute of America.