971 resultados para Blender modeling short movie rendering 3d


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis C is a rapidly developing area of medicine – diagnostic tools are ever more refined, and entirely new treatments and treatment strategies are arriving, with more on the horizon. And because the virus affects such a large and varying population – up to 170 million at last count – we think it is important to have a pocket reference especially devoted to hepatitis C. We look forward to your comments on the usefulness of our 2014 Short Guide to Hepatitis C, which is an expansion and update of the HCV chapters in Hepatology – A Clinical Textbook (2014), also published by Flying Publisher. As always, we invite qualified people everywhere to translate this book into other languages, and make them available widely. This web-based free-of- harge concept is made possible by unrestricted educational grants from the pharmaceutical industry and has allowed the material to reach countries usually not covered by print media. We are convinced that this new pocket guide concept, focusing here on hepatitis C, will become a valuable source of information for our readers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How long does it take to learn another language? How many words do you need to learn? Are languages within the reach of everybody? Which teachers would you choose and which teachers should you avoid? These are some of the questions you ask yourself when you start learning a new language.The Word Brain provides the answers. If you have learned foreign languages in the past, consider reading it. If you or your children need to learn languages in the future, you must read it. What you will discover in two hours will change for ever the way you see languages and language learning. The principles of The Word Brain are timeless. Our children’s grandchildren will follow them when they discover the people of our planet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: Remodelamento ventricular esquerdo (RVE) após IAM caracteriza fator de mau prognóstico. Há pouca informação na literatura sobre o RVE analisado com ecocardiografia tridimensional (ECO 3D) OBJETIVO: Analisar com ECO 3D as modificações geométricas e volumétricas do ventrículo esquerdo (VE) seis meses após IAM em pacientes submetidos a tratamento primário percutâneo. MÉTODOS: Estudo prospectivo com ECO 3D de 21 indivíduos (16 homens, 56 ± 12 anos), acometidos por IAM com elevação do segmento ST. Foi feita a análise morfofuncional (VE) com ECO 3D (volumes, FEVE, índice de esfericidade 3D) até sete dias e seis meses após o IAM. RVE foi considerado para aumento > 15% do volume diastólico final do VE (VDFVE) após seis meses do IAM, comparado ao VDFVE até sete dias do evento. RESULTADOS: Oito (38%) pacientes apresentaram RVE. Medidas ecocardiográficas (n = 21 pacientes): I- até sete dias do IAM: 1- VDFVE: 92,3 ± 22,3 mL; 2- FEVE: 0,51 ± 0,01; 3- índice de esfericidade: 0,38 ± 0,05; II- após seis meses: 1- VDFVE: 107,3 ± 26,8 mL; 2- FEVE: 0,59 ± 0,01; 3- índice de esfericidade: 0,31 ± 0,05. Coeficiente de correlação (r) entre índice de esfericidade até sete dias do IAM e VDFVE aos seis meses (n = 8) após o IAM: r: 0,74, p = 0,0007; (r) entre índice de esfericidade após seis meses do IAM e VDFVE aos seis meses do IAM: r: 0,85, p < 0,0001. CONCLUSÃO: Nesta série, foi observado RVE em 38% dos pacientes seis meses após IAM. O índice de esfericidade tridimensional foi associado à ocorrência de RVE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Heart transplantation is considered the gold standard therapy for the advanced heart failure, but donor shortage, especially in pediatric patients, is the main limitation for this procedure, so most sick patients die while waiting for the procedure.Objective:To evaluate the use of short-term circulatory support as a bridge to transplantation in end-stage cardiomyopathy.Methods:Retrospective clinical study. Between January 2011 and December 2013, 40 patients with cardiomyopathy were admitted in our Pediatric Intensive Care Unit, with a mean age of 4.5 years. Twenty patients evolved during hospitalization with clinical deterioration and were classified as Intermacs 1 and 2. One patient died within 24 hours and 19 could be stabilized and were listed. They were divided into 2 groups: A, clinical support alone and B, implantation of short-term circulatory support as bridge to transplantation additionally to clinical therapy.Results:We used short-term mechanical circulatory support as a bridge to transplantation in 9. In group A (n=10), eight died waiting and 2 patients (20%) were transplanted, but none was discharged. In group B (n=9), 6 patients (66.7%) were transplanted and three were discharged.The mean support time was 21,8 days (6 to 984h). The mean transplant waiting list time was 33,8 days. Renal failure and sepsis were the main complication and causeof death in group A while neurologic complications were more prevalent en group B.Conclusion:Mechanical circulatory support increases survival on the pediatric heart transplantation waiting list in patients classified as Intermacs 1 and 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coupled Electromechanical Analysis, MEMS Modeling, MEMS, RF MEMS Switches, Defected Ground Structures, Reconfigurable Resonator

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work focuses on the modeling and numerical approximations of population balance equations (PBEs) for the simulation of different phenomena occurring in process engineering. The population balance equation (PBE) is considered to be a statement of continuity. It tracks the change in particle size distribution as particles are born, die, grow or leave a given control volume. In the population balance models the one independent variable represents the time, the other(s) are property coordinate(s), e.g., the particle volume (size) in the present case. They typically describe the temporal evolution of the number density functions and have been used to model various processes such as granulation, crystallization, polymerization, emulsion and cell dynamics. The semi-discrete high resolution schemes are proposed for solving PBEs modeling one and two-dimensional batch crystallization models. The schemes are discrete in property coordinates but continuous in time. The resulting ordinary differential equations can be solved by any standard ODE solver. To improve the numerical accuracy of the schemes a moving mesh technique is introduced in both one and two-dimensional cases ...