978 resultados para Automatic Image Annotation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Albacore and Atlantic Bluefin tuna are two pelagic fish. Atlantic Bluefin tuna is included in the IUCN red list of threatened species and albacore is considered to be near threatened, so conservation plans are needed. However, no genomic resources are available for any of them. In this study, to better understand their transcriptome we functionally annotated orthologous genes. In all, 159 SNPs distributed in 120 contigs of the muscle transcriptome were analyzed. Genes were predicted for 98 contigs (81.2%) using the bioinformatics tool BLAST. In addition, another bioinformatics tool, BLAST2GO was used in order to achieve GO terms for the genes, in which 41 sequences were given a biological process, and 39 sequences were given a molecular process. The most repeated biological process was metabolism and it is important that no cellular process was given in any of the sequences. The most abundant molecular process was binding and very few catalytic activity processes were given. From the initial 159 SNPs, 40 were aligned with a sequence in the database after BLAST2GO was run, and were polymorphic in Atlantic Bluefin tuna and monomorphic in albacore. From these 40 SNPs, 24 were located in an open reading frame of which four were non-synonymous and 20 were synonymous and 16 were not located in a known open reading frame,. This study provides information for better understanding the ecology and evolution of these species and this is important in order to establish a proper conservation plan and an appropriate management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose a novel method for measuring the coma aberrations of lithographic projection optics based on relative image displacements at multiple illumination settings. The measurement accuracy of coma can be improved because the phase-shifting gratings are more sensitive to the aberrations than the binary gratings used in the TAMIS technique, and the impact of distortion on displacements of aerial image can be eliminated when the relative image displacements are measured. The PROLITH simulation results show that, the measurement accuracy of coma increases by more than 25% under conventional illumination, and the measurement accuracy of primary coma increases by more than 20% under annular illumination, compared with the TAMIS technique. (c) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A good understanding of the population dynamics of algal communities is vital in many ecological and pollution studies of freshwater and oceanic systems. Present methods require manual counting and identification of algae and can take up to 90 min to obtain a statistically reliable count on a complex population. Several alternative techniques to accelerate the process have been tried on marine samples but none have been completely successful because insufficient effort has been put into verifying the technique before field trials. The objective of the present study has been to assess the potential of in vivo fluorescence of algal pigments as a means of automatically identifying algae. For this work total fluorescence spectroscopy was chosen as the observation technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We proposed a high accuracy image sensor technique for sinusoidal phase-modulating interferometer in the field of the surface profile measurements. It solved the problem of the CCD's pixel offset of the same column under two adjacent rows, eliminated the spectral leakage, and reduced the influence of external interference to the measurement accuracy. We measured the surface profile of a glass plate, and its repeatability precision was less than 8 nm and its relative error was 1.15 %. The results show that it can be used to measure surface profile with high accuracy and strong anti-interference ability. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the sinusoidal phase modulating interferometer technique, the high-speed CCD is necessary to detect the interference signals. The reason of ordinary CCD's low frame rate was analyzed, and a novel high-speed image sensing technique with adjustable frame rate based on ail ordinary CCD was proposed. And the principle of the image sensor was analyzed. When the maximum frequency and channel bandwidth were constant, a custom high-speed sensor was designed by using the ordinary CCD under the control of the special driving circuit. The frame rate of the ordinary CCD has been enhanced by controlling the number of pixels of every frame; therefore, the ordinary of CCD can be used as the high frame rate image sensor with small amount of pixels. The multi-output high-speed image sensor has the deficiencies of low accuracy, and high cost, while the high-speed image senor with small number of pixels by using this technique can overcome theses faults. The light intensity varying with time was measured by using the image sensor. The frame rate was LIP to 1600 frame per second (f/s), and the size of every frame and the frame rate were adjustable. The correlation coefficient between the measurement result and the standard values were higher than 0.98026, and the relative error was lower than 0.53%. The experimental results show that this sensor is fit to the measurements of sinusoidal phase modulating interferometer technique. (c) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

光路自动准直系统应用于惯性约束聚变的高功率激光装置中的光束自动调整。图像处理是光路自动准直的关键技术之一。针对神光Ⅲ原型装置,结合阈值化、重心法、中值滤波和圆拟合等多种不同的图像处理方法设计了一套合理的准直方案,并且在模拟实验平台上进行了实验验证。实验结果表明,光路自动准直系统能够在15min之内顺利完成光路的自动调整,光束近场调整精度优于近场光斑的±0.5%,光束远场调整精度≤±0.3″,满足了原型装置的总体要求。