994 resultados para Application of graphical meshes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the application of an improved nonlinear principal component analysis (PCA) to the detection of faults in polymer extrusion processes. Since the processes are complex in nature and nonlinear relationships exist between the recorded variables, an improved nonlinear PCA, which incorporates the radial basis function (RBF) networks and principal curves, is proposed. This algorithm comprises two stages. The first stage involves the use of the serial principal curve to obtain the nonlinear scores and approximated data. The second stage is to construct two RBF networks using a fast recursive algorithm to solve the topology problem in traditional nonlinear PCA. The benefits of this improvement are demonstrated in the practical application to a polymer extrusion process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Inappropriate prescribing is a well-documented problem in older people. The new screening tools, STOPP (Screening Tool of Older Peoples' Prescriptions) and START (Screening Tool to Alert doctors to Right Treatment) have been formulated to identify potentially inappropriate medications (PIMs) and potential errors of omissions (PEOs) in older patients. Consistent, reliable application of STOPP and START is essential for the screening tools to be used effectively by pharmacists. OBJECTIVE: To determine the interrater reliability among a group of clinical pharmacists in applying the STOPP and START criteria to elderly patients' records. METHODS: Ten pharmacists (5 hospital pharmacists, 5 community pharmacists) were given 20 patient profiles containing details including the patients' age and sex, current medications, current diagnoses, relevant medical histories, biochemical data, and estimated glomerular filtration rate. Each pharmacist applied the STOPP and START criteria to each patient record. The PIMs and PEOs identified by each pharmacist were compared with those of 2 academic pharmacists who were highly familiar with the application of STOPP and START. An interrater reliability analysis using the k statistic (chance corrected measure of agreement) was performed to determine consistency between pharmacists. RESULTS: The median ? coefficients for hospital pharmacists and community pharmacists compared with the academic pharmacists for STOPP were 0.89 and 0.88, respectively, while those for START were 0.91 and 0.90, respectively. CONCLUSIONS: Interrater reliability of STOPP and START tools between pharmacists working in different sectors is good. Pharmacists working in both hospitals and in the community can use STOPP and START reliably during their everyday practice to identify PIMs and PEOs in older patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 5'-O-monomethoxytrityl-3'-S-(aryldisulfanyl)-3'-deoxythymidines 7 and 8 have been prepared by the reaction of 5'-O-monomethoxytrityl-3'-thiothymidine with the appropriate arenesulfenyl chloride. These disulfides undergo a Michaelis–Arbusov reaction with simple trialkyl phosphites to yield 5'-O-monomethoxytrityl-3'-thiothymidin-3'-yl O,O-dialkyl phosphorothiolates. More interestingly, 3'-deoxy-3'-S-(2, 4-dinitrophenylsulfanyl)-5'-O-monomethoxytritylthymidine 8 reacts with a variety of thymidin-5'-yl dialkyl phosphites to give dithymidine phosphorothiolate triesters with the phosphorothiolate group protected with either a methyl or a 2-cyanoethyl group. 3'-O-(tert-Butyldimethylsilyl)thymidin-5'-yl triethylammoniumphosphonate 17 is converted into the corresponding bis-(O-trimethylsilyl) phosphite by treatment with bis(trimethylsilyl)trifluoroacetamide. in situ Reaction of this phosphate with disulfide 8 gives, after work-up, the dithymidine phosphorothiolate diester directly. Methylation of compound 17 with methyl chloromethanoate, followed by silylation and subsequent reaction with disulfide 8, gives the methyl-protected dithymidine phosphorothiolate triester.