954 resultados para Angle Droop
Resumo:
PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.
Resumo:
We reviewed 19 patients (24 knees) with patellofemoral instability treated surgically with antero-medialisation of the tibial tubercle and lateral retinacular release. Twenty-two knees had recurrent patellar dislocation and two patellar subluxation. Lateral retinacular release was performed arthroscopically in 15 knees. Average follow-up was 52 (16-86) months. There was one postoperative haemarthrosis and one failed fixation, which needed surgical revision. The average Lysholm score improved from 63.3 to 98 and only one knee had persistent patello-femoral pain postoperatively. The patellar tilt angle improved from 9.4 degrees to 5.5 degrees . There were no redislocations. We find that the surgical technique produces a consistent correction of patellar instability, but long-term studies are needed to confirm whether it can prevent arthritic degeneration.
Resumo:
de imagem em RM, caracterizada pela sua alta resolução espacial e grande sensibilidade a diferenças de susceptibilidade magnética dos tecidos, acentuando as propriedades paramagnéticas de produtos como a desoxihemoglobina, hemossiderina, ferro e cálcio e sendo particularmente útil na avaliação das estruturas venosas. Objectivos: O objectivo deste trabalho é fazer uma breve revisão das aplicações clínicas da sequência SWI em neuropediatria e demonstrar a sua grande utilidade, nomeadamente em comparação as a sequência T2*. Material e Métodos: Os exames foram realizados a crianças com idades compreendidas entre o período neonatal e os 16 anos, internadas ou seguidas em consulta no Hospital Pediátrico D. Estefânia; as imagens SWI foram efectuadas em equipamento Siemens 1.5 T, Avanto, com os seguintes parâmetros: TR 49, TE 40, flip angle 15, espessura 1,6mm. Resultados: Apresentamos vários casos ilustrativos de patologias em que o SWI demonstra a sua utilidade e mais-valia, nomeadamente na detecção de lesões hemorrágicas recentes ou antigas em diferentes contextos particulares em neuropediatria (patologia hipoxico-isquémica, vascular, trauma não acidental), detecção de cavernomas e anomalias venosas de desenvolvimento, avaliação de tumores e doenças neurodegenerativas. Conclusão: A sequência SWI é bastante útil na avaliação imagiológica de várias patologias e variantes venosas em neuropediatria, fornecendo uma informação adicional com implicações diagnósticas e prognósticas comparativamente com o T2*, obviando também a administração de contraste para avaliação de estruturas venosas.
Resumo:
Pericardial cysts are rare benign congenital malformations, usually small, asymptomatic and detected incidentally on chest X-ray as a mass located in the right costophrenic angle. Giant pericardial cysts are very uncommon and produce symptoms by compressing adjacent structures. In this report, the authors present a case of a symptomatic giant pericardial cyst incorrectly diagnosed as dextrocardia on chest X-ray.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle (β) >75°, and/or suprarenal angle (α) >60°, or neck length >10 mm with β >60°, and/or α >45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41). Groups did not differ significantly in regard to freedom from rupture (p = .79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean Δα -15.6°, mean Δβ -30.6°) than in the control group (mean Δα -0.39°, mean Δβ -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.
Resumo:
PURPOSE: (i) To investigate whether pulsatility index (PI) and mean flow velocities (MFV) are altered in glaucoma patients. (ii) To evaluate the significance of PI in retrobulbar autoregulation capacity. METHODS: Patients with primary open-angle glaucoma (POAG; n = 49), normal tension glaucoma (NTG; n = 62) and healthy controls (n = 48) underwent colour Doppler imaging measurements of the retrobulbar vasculature. Kruskal-Wallis test was used to compare variables between the three diagnostic groups. Restricted cubic splines were used to determine nonlinearities between the resistive index (RI) and PI correlations. RESULTS: Mean flow velocities (MFV) were lower in both short posterior ciliary arteries (SCPA) and central retinal arteries (CRA) from the two glaucoma groups (p < 0.04 versus healthy controls). No differences were detected in RI or PI in any arteries of the three diagnostic groups (p > 0.08). In healthy individuals, correlations between RI and PI were linear in all arteries. In both POAG and NTG patients, CRA presented a nonlinear curve with a cutpoint at RI 0.77 (p < 0.001) and 0.61 (p = 0.03), respectively, above which the slope increased nearly five- and tenfold (POAG: 1.96 to 10.06; NTG: -0.46-4.06), respectively. A nonlinear correlation in the ophthalmic artery was only observed in NTG patients, with a cutpoint at RI 0.82 (p < 0.001), above which the slope increased from 3.47 to 14.03. CONCLUSIONS: Glaucoma patients do not present the linear relationships between RI and PI observed in healthy individuals. Their nonlinear relations may be indicative of an altered autoregulation and suggest a possible threshold RI could be determined above which autoregulatory disturbances become more relevant.
Resumo:
PURPOSE: Recently, the absence of spontaneous venous pulsation (SVP) has been suggested as a vascular risk factor for primary open-angle glaucoma (POAG). As the mechanism behind this phenomenon is still unknown, the authors have studied this vascular component using colour Doppler imaging (CDI). METHODS: A total of 236 patients were divided into three diagnostic groups: healthy controls (81), POAG (86) and normal tension glaucoma (NTG; 69). All subjects were submitted to CDI studies of the retrobulbar circulation, intraocular pressure measurements and assessment of SVP existence. Mann-Whitney, chi-square contingency tables and Spearman correlations were used to explore differences and correlations between variables in the diagnostic groups. RESULTS: Eighty-two percent of healthy controls had SVP (66/81), while a smaller numbers were registered in both glaucoma groups: POAG - 50% (43/86); NTG - 51% (35/69). In NTG patients, but not in POAG patients, the prevalence of the SVP phenomenon decreases with increased glaucoma damage (p = 0.04; p = 0.55, respectively). Overall glaucoma patients from both groups had lower central retinal vein (CRV) velocities than the healthy controls (p < 0.05). NTG patients with SVP had less severe visual field defects (mean defect -6.92 versus -11.1, p < 0.05), higher [correction added after online publication 21 September 2012; the word 'higher' has been inserted to replace the word 'lower'] peak systolic and mean flow velocities in the central retinal artery (p < 0.01; p < 0.05, respectively) as well as higher [correction added after online publication 21 September 2012; the word higher has been inserted to replace the word lower] maximal velocities and RI of the CRV (p < 0.02; p < 0.05, respectively). CONCLUSIONS: Glaucoma patients have a decrease in CRV velocities. SVP is less prevalent in glaucoma patients than in healthy individuals. This phenomenon apparently reflects different hemodynamic patterns in the central retinal vessels. This variable may be of particular importance in NTG patients, where it may be associated with more advanced functional damage.
Resumo:
PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.
Resumo:
Urofacial syndrome (UFS) is an autosomal recessive congenital disease featuring grimacing and incomplete bladder emptying. Mutations of HPSE2, encoding heparanase 2, a heparanase 1 inhibitor, occur in UFS, but knowledge about the HPSE2 mutation spectrum is limited. Here, seven UFS kindreds with HPSE2 mutations are presented, including one with deleted asparagine 254, suggesting a role for this amino acid, which is conserved in vertebrate orthologs. HPSE2 mutations were absent in 23 non-neurogenic neurogenic bladder probands and, of 439 families with nonsyndromic vesicoureteric reflux, only one carried a putative pathogenic HPSE2 variant. Homozygous Hpse2 mutant mouse bladders contained urine more often than did wild-type organs, phenocopying human UFS. Pelvic ganglia neural cell bodies contained heparanase 1, heparanase 2, and leucine-rich repeats and immunoglobulin-like domains-2 (LRIG2), which is mutated in certain UFS families. In conclusion, heparanase 2 is an autonomic neural protein implicated in bladder emptying, but HPSE2 variants are uncommon in urinary diseases resembling UFS.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia do Ambiente
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Geológica (Georrecursos)
Resumo:
Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.