946 resultados para Adhesive mortar
Resumo:
The mechanical and adhesives properties of epoxy formulations based on diglycidyl ether of bisphenol A cured with various aliphatic amines were evaluated in the glass state. Impact tests were used to determine the impact energy. The adhesive properties have been evaluated in terms single lap shear using steel adherends. Its durability in water at ambient temperature (24 degrees C) and at 80 degrees C has also been analyzed. The fracture mechanisms were determined by optical microscopy. It was observed a strong participation of the cohesive fracture mechanisms in all epoxy system studied. The 1-(2-aminoethyl)piperazine epoxy adhesive and piperidine epoxy adhesive presents the best adhesive strength and the largest impact energy. The durability in water causes less damage to piperidine epoxy networks. This behavior appears to be associated with the lower water uptake tendency of homopolymerised resins due to its lower hydroxyl group concentration. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents a theoretical analysis of a density measurement cell using an unidimensional model composed by acoustic and electroacoustic transmission lines in order to simulate non-ideal effects. The model is implemented using matrix operations, and is used to design the cell considering its geometry, materials used in sensor assembly, range of liquid sample properties and signal analysis techniques. The sensor performance in non-ideal conditions is studied, considering the thicknesses of adhesive and metallization layers, and the effect of residue of liquid sample which can impregnate on the sample chamber surfaces. These layers are taken into account in the model, and their effects are compensated to reduce the error on density measurement. The results show the contribution of residue layer thickness to density error and its behavior when two signal analysis methods are used. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
JUSTIFICATIVA E OBJETIVOS: Complicações neurológicas da anestesia subaracnóidea, apesar de raras, podem determinar seqüelas importantes. O objetivo deste estudo é apresentar estas complicações com a finalidade de esclarecer os fatores desencadeantes, o que facilita o diagnóstico das lesões. CONTEÚDO: São apresentadas as seguintes complicações: lesão de nervo desencadeada pela agulha e cateter, cefaléia pós-punção, síndrome da artéria espinhal anterior, hematoma espinhal, meningite bacteriana, meningite asséptica, aracnoidite adesiva, síndrome da cauda eqüina e sintomas neurológicos transitórios. CONCLUSÕES: O conhecimento dos fatores desencadeantes de complicações neurológicas determinadas pela anestesia subaracnóidea pode prevenir as lesões, diagnosticar e tratar mais precocemente e, desse modo, mudar o prognóstico das mesmas.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this work the use of coconut fiber (coir) and bamboo shafts as reinforcement of soil-cement was studied, in order to obtain an alternative material to make stakes for fences in rural properties. The main objective was to study the effect of the addition of reinforcement to the soil-cement matrix. The effect of humidity on the mechanical properties was also analyzed. The soil-cement mortar was composed by a mixture, in equal parts, of soil and river sand, 14% in weight of cement and 10 % in weight of water. As reinforcement, different combinations of (a) coconut fiber with 15 mm mean length (0,3 %, 0,6 % and 1,2 % in weight) and (b) bamboo shafts, also in crescent quantities (2, 4 and 8 shafts per specimen) were used. For each combination 6 specimens were made and these were submitted to three point flexural test after 28 days of cure. In order to evaluate the effect of humidity, 1 specimen from each of the coconut fiber reinforced combination was immersed in water 24 hours prior to flexural test. The results of the tests carried out indicated that the addition of the reinforcement affected negatively the mechanical resistance and, on the other hand, increased the tenacity and the ductility of the material.
Resumo:
O paciente desenvolveu linforragia na região inguinal direita, depois de ponte aorto-bifemoral com enxerto de dácron®. Não respondeu ao tratamento conservador com cuidados locais e compressão. Foi realizado exame de ultra-sonografia Doppler, que evidenciou grande linfocele (6,4 x 3,36 x 6,1 cm), tratada pelo esvaziamento da loja por aspiração e injeção de cola de fibrina (1,6 mL) em seu interior. O paciente se recuperou sem intercorrências e sem recidiva, após 3 meses de seguimento.
Resumo:
A Brazilian dictionary states that "ulcer", from the Latin word ulcuserise, is a superficial lesion on skin or mucous membrane characterized by an inflammatory process and loss of tissue. Ulcers are a relatively frequent problem that may be worsen by infection or long-time duration. In these cases, they can represent a serious public health issue, since the increased case number contributes to the burden on the public health service. In recent decades, wound treatment has advanced in technological and scientific aspects regarding both development of new products and techniques. Ongoing research in this area is providing new products for wound treatment. Among newly tested substances that have presented successful results is fibrin glue, a snake venom derivative that promotes reduction of infection and edema as well as bleeding control and pain decrease. Thus, the present study aimed to evaluate fibrin glue effects on ulcers of venous origin in 24 patients that were divided into two groups. The first one (G1) consisted of 11 patients treated without the adhesive while the second group (G2) was composed of 13 persons who were under therapy with the adhesive. The results of this study revealed that patients treated with fibrin glue evolved to a satisfactory healing when compared to the other group. Therefore, fibrin glue is an appropriate alternative for treating leg ulcers with several advantages: easy application, less pain, early hospital discharge, not transmiting diseases, lower cost than the adhesive currently available in Brazil and, finally, it is a Brazilian technology.
Resumo:
Fibrin sealant, a widely available tissue adhesive, has been used since 1940 in a variety of clinical applications. Commercially available fibrin sealant products are synthesized from bovine thrombin and human fibrinogen, which may transmit infectious diseases, and recipients may also develop antibodies against bovine thrombin. Bearing these disadvantages in mind, a new fibrin sealant was developed in 1989 by a group of researchers from the Center for the Study of Venoms and Venomous Animals, in São Paulo State, Brazil. The main purpose was to produce an adhesive fibrin without using human blood, to avoid transmitting infectious diseases. The components of this novel sealant were extracted from large animals and a serine proteinase extracted from Crotalus durissus terrificus snake venom. The applicability of this sealant was tested in animals and humans with beneficial results. The new fibrin sealant can be a useful tool clinically due to its flexibility and diversity of applications. This sealant is a biological and biodegradable product that ( 1) does not produce adverse reactions, ( 1) contains no human blood, ( 3) has a good adhesive capacity, ( 4) gives no transmission of infectious diseases, and ( 5) may be used as an adjuvant in conventional suture procedures. The effectiveness of this new fibrin sealant is reviewed and its development and employment are described.
Resumo:
OBJETIVO: Avaliar o desempenho da análise de imagem digital na estimativa da área acometida pelas úlceras crônicas dos membros inferiores. MÉTODOS: Estudo prospectivo em que foram mensuradas úlceras empregando o método planimétrico clássico, utilizando desenho dos seus contornos em filme plástico transparente, medida sua área posteriormente por folha milimetrada. Esses valores foram utilizados como padrão para a comparação com a estimativa de área pelas fotografias digitais padronizadas das úlceras e dos desenhos das mesmas em filme plástico. Para criar um referencial de conversão dos pixels em milímetros, foi empregado um adesivo com tamanho conhecido, adjacente à úlcera. RESULTADOS: foram avaliadas 42 lesões em 20 pacientes portadores de úlceras crônicas de membros inferiores. As áreas das úlceras variaram de 0,24 a 101,65cm². Observou-se forte correlação entre as medidas planimétricas e as fotos das úlceras (R²=0,86 p<0,01), porém a correlação das medidas planimétricas com as fotos digitais dos desenhos das úlceras foi ainda maior (R²=0,99 p<0,01). CONCLUSÃO: A fotografia digital padronizada revelou-se método rápido, preciso e não-invasivo capaz de estimar a área afetada por úlceras. A avaliação das medidas fotográficas dos contornos das úlceras deve ser preferida em relação à análise de sua fotografia direta.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the tensile strength of orthodontic wires bonded onto the enamel with cyanoacrylate ester. To obtain the specimens, 120 human premolars (extracted for orthodontic or periodontal reasons) were included in acrylic blocks of rapid polymerization with three teeth each. Four groups were formed with ten specimens each. In the specimens, a dental splint model was made with cyanoacrylate ester and round stainless steel wire. In groups I, II and III, cyanoacrylate ester was used with round steel wires, with variation in diameter: 0.014 inches; 0.016 inches and 0.018 inches, respectively. In group IV, round steel wire 0.018 inches was used with photo polymerizing resin composite with previous acid etching. The adhesive force of the materials was measured in two points under the action of the tensiometer (ETM-USA). The number of loose wires was counted along with those that remained fixed according to the different levels of force applied because of the direction of the tensile force (vertical or horizontal) and the diameter of the wire used. The data obtained were first submitted to a descriptive analysis and then submitted to a statistical analysis (Friedman's Test and Dunn's Test of Multiple Comparison - Epi-info 3.2). Within the limitations of the experimental conditions presented, the cyanoacrylate ester or 'Super Bonder (R)' maintained bonded to enamel and steel wires (0.016 and 0.018 inches) during the tensile strength tests under different levels of applied forces.