982 resultados para Abdominal computed tomography


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Smuggling dissolved drugs, especially cocaine, in bottled liquids is a problem at borders nowadays. Common fluoroscopy of packages at the border cannot detect contaminated liquids. To find a dissolved drug, an immunological test using a drug-test panel has to be performed. This means that a control sample of the cargo must be opened to perform the test. As it is not possible to open all boxes, and as smugglers hide the drugcontaining boxes between regularly filled boxes, contaminated cargos can be overlooked. Investigators sometimes cannot perform the drug-test panel because they try not to arouse the smugglers' suspicion in order to follow the cargo and to find the recipient. Aims: The objective of our studies was to define non-invasive examination techniques to investigate cargos that are suspicions to contain dissolved cocaine without leaving traces on the samples. We examined vessels containing cocaine by radiological cross-section techniques such as multidetector computed tomography (MDCT) and magnetic resonance spectroscopy (MRS). Methods: In a previous study, we examined bottles of wine containing dissolved cocaine in different quantities using an MDCT unit. To distinguish between bottles containing red wine and those where cocaine was solved in the wine, cross sectional 2D-images have been reconstructed and the absorption of X-rays was quantified by measuring the mean density of the liquid inside the bottles. In our new study, we investigated phantoms containing cocaine dissolved in water with or without ethanol as well as cocaine dissolved in different sorts of commercially available wine by the use of a clinical magnetic resonance unit (3 tesla). To find out if dissolved cocaine could be detected, magnetic resonance spectroscopy (1H MRS) was performed. Results: By using a MDCT-unit and measuring the mean attenuation of X-rays, it is possible to distinguish weather substances are dissolved in a liquid or not, if a comparative liquid without any solutions is available. The increase of the mean density indicates the presence of dissolved substances without the possibility to identify the substance. By using magnetic resonance spectroscopy, dissolved cocaine can be clearly identified because it produces distinctive resonances in the spectrum. In contrast to MDCT, this technique shows a high sensitivity (detection of 1 mM cocaine in wine). Conclusions: Cross-sectional imaging techniques such as MDCT and MRS appropriated to examine cargos that are suspicious to contain dissolved cocaine. They allow to perform non-invasive investigations without leaving any trace on the cargo. While an MDCT scan can detect dissolved substances in liquids, identification of cocaine can be obtained by MR-spectroscopy. Acknowledgment: This work was supported by the Centre d'Imagerie BioMédicale (CIBM) of the University of Lausanne (UNIL), the Swiss Federal Institute of Technology Lausanne (EPFL), the University of Geneva (UniGe), the Centre Hospitalier Universitaire Vaudois (CHUV), the Hôpitaux Universitaire de Genève (HUG) and the Leenaards and the Jeantet Foundations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Strontium ranelate appears to influence more than alendronate distal tibia bone microstructure as assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT), and biomechanically relevant parameters as assessed by micro-finite element analysis (mu FEA), over 2 years, in postmenopausal osteoporotic women.Introduction Bone microstructure changes are a target in osteoporosis treatment to increase bone strength and reduce fracture risk.Methods Using HR-pQCT, we investigated the effects on distal tibia and radius microstructure of strontium ranelate (SrRan; 2 g/day) or alendronate (70 mg/week) for 2 years in postmenopausal osteoporotic women. This exploratory randomized, double-blind trial evaluated HR-pQCT and FEA parameters, areal bone mineral density (BMD), and bone turnover markers.Results In the intention-to-treat population (n = 83, age: 64 +/- 8 years; lumbar T-score: -2.8 +/- 0.8 [DXA]), distal tibia Cortical Thickness (CTh) and Density (DCort), and cancellous BV/TV increased by 6.3%, 1.4%, and 2.5%, respectively (all P < 0.005), with SrRan, but not with alendronate (0.9%, 0.4%, and 0.8%, NS) (P < 0.05 for all above between-group differences). Difference for CTh evaluated with a distance transformation method was close to significance (P = 0.06). The estimated failure load increased with SrRan (+2.1%, P < 0.005), not with alendronate (-0.6%, NS) (between-group difference, P < 0.01). Cortical stress was lower with SrRan (P < 0.05); both treatments decreased trabecular stress. At distal radius, there was no between-group difference other than DCort (P < 0.05). Bone turnover markers decreased with alendronate; bALP increased (+21%) and serum-CTX-I decreased (-1%) after 2 years of SrRan (between-group difference at each time point for both markers, P < 0.0001). Both treatments were well tolerated.Conclusions Within the constraints of HR-pQCT method, and while a possible artefactual contribution of strontium cannot be quantified, SrRan appeared to influence distal tibia bone microstructure and FEA-determined biomechanical parameters more than alendronate. However, the magnitude of the differences is unclear and requires confirmation with another method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The objective of this experiment is to establish a continuous postmortem circulation in the vascular system of porcine lungs and to evaluate the pulmonary distribution of the perfusate. This research is performed in the bigger scope of a revascularization project of Thiel embalmed specimens. This technique enables teaching anatomy, practicing surgical procedures and doing research under lifelike circumstances. METHODS: After cannulation of the pulmonary trunk and the left atrium, the vascular system was flushed with paraffinum perliquidum (PP) through a heart-lung machine. A continuous circulation was then established using red PP, during which perfusion parameters were measured. The distribution of contrast-containing PP in the pulmonary circulation was visualized on computed tomography. Finally, the amount of leak from the vascular system was calculated. RESULTS: A reperfusion of the vascular system was initiated for 37 min. The flow rate ranged between 80 and 130 ml/min throughout the experiment with acceptable perfusion pressures (range: 37-78 mm Hg). Computed tomography imaging and 3D reconstruction revealed a diffuse vascular distribution of PP and a decreasing vascularization ratio in cranial direction. A self-limiting leak (i.e. 66.8% of the circulating volume) towards the tracheobronchial tree due to vessel rupture was also measured. CONCLUSIONS: PP enables circulation in an isolated porcine lung model with an acceptable pressure-flow relationship resulting in an excellent recruitment of the vascular system. Despite these promising results, rupture of vessel walls may cause leaks. Further exploration of the perfusion capacities of PP in other organs is necessary. Eventually, this could lead to the development of reperfused Thiel embalmed human bodies, which have several applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Until recently, it was accepted that the rate of complications and failure of medical therapy were higher during recurrent episodes of diverticulitis. New data and new interpretation of older studies have challenged this opinion. The aim of the present study was to determine whether recurrent diverticulitis in comparison with the initial episode has a different short-term outcome after medical or surgical treatment. METHODS: This was a retrospective cohort study of 271 consecutive patients admitted for diverticulitis confirmed by computed tomography (CT) between 2001 and 2004. Altogether 202 patients had an initial episode (group I), and 69 had recurrent diverticulitis (group R). A total of 20 clinical and 15 radiologic parameters were analyzed and compared between the two groups, including need for surgery, clinical presentation at admission, response to treatment, complications, laboratory parameters, and pathologic CT features (colonic wall thickening, abscess, pneumoperitoneum, free intraperitoneal fluid). An unpaired Student's t-test and Fisher's and Wilcoxon's tests were applied for statistical analysis. RESULTS: None of the clinical or radiologic parameters was statistically different between the two groups. Regarding surgery, 15.8% of the group I patients needed surgery at admission compared to 5.8% in group R (p = 0.04). Conservative treatment failure was similar in the two groups (10.7% vs. 10.0%; p = 0.84). There was 3% mortality at 30 days in group I compared to 0% in group R. CONCLUSIONS: Recurrent episodes of diverticulitis do not lead to more complications and more conservative treatment failure. Moreover, surgery at admission was less frequent among patients who presented with a recurrence.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Investigation of violent death, especially cases of sharp trauma and gunshot, is an important part of medico-legal investigations. Beside the execution of a conventional autopsy, the performance of a post-mortem Multi-Detector Computed Tomography (MDCT)-scan has become a highly appreciated tool. In order to investigate also the vascular system, post-mortem CT-angiography has been introduced. The most studied and widespread technique is the Multi-phase post-mortem CT-angiography (MPMCTA). Its sensitivity to detect vascular lesions is even superior to conventional autopsy. The application of MPMCTA for cases of gunshot and sharp-trauma is therefore an obvious choice, as vascular lesions are common in such victims. In most cases of sharp trauma and in several cases of gunshots, death can be attributed to exsanguinations. MPMCTA is able to detect the exact source of bleeding and also to visualize trajectories, which are of most importance in these cases. The reconstructed images allow to clearly visualizing the trajectory in a way that is easily comprehensible for not medically trained legal professionals. The sensitivity of MPMCTA for soft tissue and organ lesions approximately matches the sensitivity of conventional autopsy. However, special care, experience and effective use of the imaging software is necessary for performing the reconstructions of the trajectory. Large volume consuming haemorrhages and shift of inner organs are sources of errors and misinterpretations. This presentation shall give an overview about the advantages and limitations of the use of MPMCTA for investigating cases of gunshot and sharp-trauma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The specific effects of radiosurgery on brain tumor tissue are not well understood. We review several approaches that have been used to address this issue. Correlating the radiobiology of radiosurgery with the radioclinical outcome may help to understand these tissue changes. In vivo imaging investigations are usually performed with MRI, but the use of functional and metabolic imaging, such MR spectroscopy, positron emission tomography or single-photon emission computed tomography may provide additional information on the effects of radiosurgery. Finally, histological observations represent an invaluable source of information, when systematically analyzed in their clinical context.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

HYPOTHESIS: During total shoulder arthroplasty (TSA), humeral head subluxation may be difficult to manage. Furthermore, there is a risk for postoperative recurrence of subluxation, affecting the outcome of TSA. An accurate evaluation of the subluxation is necessary to evaluate this risk. Currently, subluxation is measured in 2 dimensions (2D), usually relative to the glenoid face. The goal of this study was to extend this measure to 3 dimensions (3D) to compare glenohumeral and scapulohumeral subluxation and to evaluate the association of subluxation with the glenoid version. MATERIALS AND METHODS: The study analyzed 112 computed tomography scans of osteoarthritic shoulders. We extended the usual 2D definition of glenohumeral subluxation, scapulohumeral subluxation, and glenoid version by measuring their orientation in 3D relative to the scapular plane and the scapular axis. We evaluated statistical associations between subluxation and version in 2D and 3D. RESULTS: Orientation of subluxation and version covered all sectors of the glenoid surface. Scapulohumeral subluxation and glenoid version were highly correlated in amplitude (R(2) = 0.71; P < .01) and in orientation (R(2) = 0.86; P < .01). Approximately every degree of glenoid version induced 1% of scapulohumeral subluxation in the same orientation of the version. Conversely, glenohumeral subluxation was not correlated to glenoid version in 2D or in 3D. CONCLUSIONS: Orientation of the humeral subluxation is rarely within the arbitrary computed tomography plane and should therefore be measured in 3D to detect out-of-plane subluxation. Scapulohumeral subluxation and glenoid version measured in 3D could bring valuable information for decision making during TSA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The relationship between coronary endothelial function and coronary calcification is not well established. METHODS: Forty-six patients 17 men [37%]; age, 47.4+/-11.4 years prospectively underwent testing for coronary endothelial function and measurement of coronary artery calcification (CAC). RESULTS: Log CAC scores were not significantly different between patients with normal (n=31) and abnormal (n=15) response of epicardial coronary artery diameter to acetylcholine (%CAD(Ach)) (median (25, 75 percentile) 1.1 (0.0, 3.7) vs. 0.3 (0.0, 2.4), P=.32) and with normal (n=28) and abnormal (n=18) response of coronary blood flow to acetylcholine (%CBF(Ach)) (0.5 (0.0, 3.6) vs. 0.5 (0.0, 3.2), P=.76). Log CAC scores did not correlate with %CAD(Ach) (r=0.08, P=.59), %CBF(Ach) (r=0.14, P=.35). CONCLUSIONS: In patients without significant coronary artery disease, coronary endothelial dysfunction showed no apparent association with coronary calcification. Our findings suggest that these 2 markers may represent separate, independent processes in the progression of coronary atherosclerosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Necrotizing fasciitis is a rare, rapidly spreading, deep-seated infection causing thrombosis of the blood vessels located in the fascia. Necrotizing fasciitis is a surgical emergency. The diagnosis typically relies on clinical findings of severe sepsis and intense pain, although subacute forms may be difficult to recognize. Imaging studies can help to differentiate necrotizing fasciitis from infections located more superficially (dermohypodermitis). The presence of gas within the necrotized fasciae is characteristic but may be lacking. The main finding is thickening of the deep fasciae due to fluid accumulation and reactive hyperemia, which can be visualized using computed tomography and, above all, magnetic resonance imaging (high signal on contrast-enhanced T1 images and T2 images, best seen with fat saturation). These findings lack specificity, as they can be seen in non-necrotizing fasciitis and even in non-inflammatory conditions. Signs that support a diagnosis of necrotizing fasciitis include extensive involvement of the deep intermuscular fascias (high sensitivity but low specificity), thickening to more than 3mm, and partial or complete absence on post-gadolinium images of signal enhancement of the thickened fasciae (fairly high sensitivity and specificity). Ultrasonography is not recommended in adults, as the infiltration of the hypodermis blocks ultrasound transmission. Thus, imaging studies in patients with necrotizing fasciitis may be challenging to interpret. Although imaging may help to confirm deep tissue involvement and to evaluate lesion spread, it should never delay emergency surgical treatment in patients with established necrotizing fasciitis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report on a 70-year-old woman with partial complex status epilepticus who was initially diagnosed with herpes simplex-2 (HSV-2) encephalitis, based on brain magnetic resonance imaging (MRI) findings, cerebrospinal fluid (CSF) lymphocytic pleocytosis and HSV-2 DNA detection by polymerase chain reaction (PCR) in the CSF, but without improvement on intravenous acyclovir. Anti-Ri antibodies were positive and computed tomography (CT) investigations revealed a small cell carcinoma at biopsy suggesting paraneoplastic encephalitis. The outcome was unfavourable and the autopsy showed typical features of paraneoplastic encephalitis but no evidence of viral inclusions. This case report is interesting because: (1) it is the first report of an autopsy proven paraneoplastic widespread encephalitis with anti-Ri antibodies; (2) despite a positive HSV-2 PCR in the CSF, there was no sign of herpetic infections of the nervous system; and (3) it illustrates the fact that if paraneoplastic antibodies are usually good markers of the underlying tumour, they are not always predictive of neurological deficits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To review and update the evidence on predictors of poor outcome (death, persistent vegetative state or severe neurological disability) in adult comatose survivors of cardiac arrest, either treated or not treated with controlled temperature, to identify knowledge gaps and to suggest a reliable prognostication strategy. METHODS: GRADE-based systematic review followed by expert consensus achieved using Web-based Delphi methodology, conference calls and face-to-face meetings. Predictors based on clinical examination, electrophysiology, biomarkers and imaging were included. RESULTS AND CONCLUSIONS: Evidence from a total of 73 studies was reviewed. The quality of evidence was low or very low for almost all studies. In patients who are comatose with absent or extensor motor response at ?72h from arrest, either treated or not treated with controlled temperature, bilateral absence of either pupillary and corneal reflexes or N20 wave of short-latency somatosensory evoked potentials were identified as the most robust predictors. Early status myoclonus, elevated values of neuron specific enolase at 48-72h from arrest, unreactive malignant EEG patterns after rewarming, and presence of diffuse signs of postanoxic injury on either computed tomography or magnetic resonance imaging were identified as useful but less robust predictors. Prolonged observation and repeated assessments should be considered when results of initial assessment are inconclusive. Although no specific combination of predictors is sufficiently supported by available evidence, a multimodal prognostication approach is recommended in all patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the accuracy of computed tomography angiography (CTA) in predicting arterial encasement by limb tumours, by comparing CTA with surgical findings (gold standard). METHODS: Preoperative CTA images of 55 arteries in 48 patients were assessed for arterial status: cross-sectional CTA images were scored as showing a fat plane between artery and tumour (score 0), slight contact between artery and tumour (score 1), partial arterial encasement (score 2) or total arterial encasement (score 3). Reformatted CTA images were assessed for arterial displacement, rigid wall, stenosis or occlusion. At surgery, arteries were classified as free or surgically encased; 45 arteries were free and 10 were surgically encased. RESULTS: Multivariate logistic regression identified the axial CTA score as a relevant predictor for arterial encasement and subsequent vascular intervention during surgery. All sites where CTA showed a fat plane between the tumour and the artery were classified as free at surgery (n = 28/28). The sensitivity of total arterial encasement on CTA (score 3) was 90%, specificity 93%, accuracy 93% and positive likelihood ratio 13.5. CONCLUSION: CTA evidence of total arterial encasement is a highly specific indication of arterial encasement. The presence of fat between the tumour and the artery on CTA rules out arterial involvement at surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: Pleural effusion is common in cancer patients and to determine its malignant origin is of huge clinical significance. PET/CT with 18F-FDG is of diagnostic value in staging and follow-up, but its ability to differentiate between malignant and benign effusions is not precisely known. Patients, methods: We examined 50 PET/CT from 47 patients (29 men, 18 women, 60±16 years) with pleural effusion and known cancer (24 NSCLC, 7 lymphomas, 5 breasts, 4 GIST, 3 mesotheliomas, 2 head and neck, 2 malignant teratoma, 1 colorectal, 1 oesophageal, 1 melanoma) for FDG uptake in the effusions using SUVmax. This was correlated to cytopathology performed after a median of 21 days (interquartile range -3 to 23), which included pH, relative distribution (macrophages, neutrophils, eosinophils, basophils, lymphocytes, plasmocytes), and absolute cell count. Results: Malignant cells were found in 17 effusions (34%) (6 NSCLC, 5 lymphomas, 2 breasts, 2 mesotheliomas, 2 malignant teratomas). SUV in malignant effusions were higher than in benign ones [3.7 (95%CI 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], with a correlation between malignant effusion and SUV (Spearman coefficient r = 0.50, p = 0.001), but not with other cytopathological or radiological parameters (ROC area 0.83±0.06). Using a 2.2-mg/l SUV threshold, 12 PET/CT studies were positive and 38 negative with sensitivity, specificity, positive and negative predictive values of 53%, 91%, 75% and 79%, respectively. For NSCLC only (n = 24), ROC area was 0.95±0.04, 7 studies were positive and 17 negative with a sensitivity, specificity, positive and negative predictive values of 83%, 89%, 71 and 94%, respectively. Conclusion: PET/CT may help to differentiate the malignant or benign origin of a pleural effusion with a high specificity in patients with known cancer, in particular NSCLC.