1000 resultados para 700199 Computer software and services not elsewhere classified
Resumo:
In this paper we discuss the first of a series of experiments evaluating earcons for critical care environments. We examine peoples’ ability to monitor earcons conveying systolic and diastolic blood pressure while conducting a distractor task. The results showed that when a beacon is present prior to the earcon, participants’ judgment of pitch and duration information improved. The results of the study also indicated presence of historical information in the earcon may interfere with participants’ judgments. However, since participants felt more confident in their recall of previous values when the historical information was present, the results may reflect insufficient training.
Resumo:
Tissue Doppler (TD) assessment of dysynchrony (DYS) is established in evaluation for bi-ventricular pacing. Time to regional minimal volume by real-time 3D echo (3D) has been applied to DYS. 3D offers simultaneous assessment of all segments and may limit errors in localization of maximum delay due to off-axis images.We compared TD and 3D for assessment of DYS. 27 patients with ischaemic cardiomyopathy (aged 60±11 years, 85% male) underwent TD with generation of regional velocity curves. The interval between QRS onset and maximal systolic velocity (TTV) was measured in 6 basal and 6 mid-cavity segments. Onthe same day,3Dwas performed and data analysed offline with Q-Lab software (Philips, Andover, MA). Using 12 analogous regional time-volume curves time to minimal volume (T3D)was calculated. The standard deviation (S.D.) between segments in TTV and T3D was calculated as a measure ofDYS. In 7 patients itwas not possible to measureT3D due to poor images. In the remaining 20, LV diastolic volume, systolic volume and EF were 128±35 ml, 68±23 ml and 46±13%, respectively. Mean TTV was less than mean T3D (150±33ms versus 348±54 ms; p < 0.01). The intrapatient range was 20–210ms for TTV and 0–410ms for T3D. Of 9 patients (45%) with significantDYS (S.D. TTV > 32 ms), S.D. T3D was 69±37ms compared to 48±34ms in those without DYS (p = ns). In DYS patients there was concordance of the most delayed segment in 4 (44%) cases.Therefore, different techniques for assessing DYS are not directly comparable. Specific cut-offs for DYS are needed for each technique.
Resumo:
Conceptual modeling forms an important part of systems analysis. If this is done incorrectly or incompletely, there can be serious implications for the resultant system, specifically in terms of rework and useability. One approach to improving the conceptual modelling process is to evaluate how well the model represents reality. Emergence of the Bunge-Wand-Weber (BWW) ontological model introduced a platform to classify and compare the grammar of conceptual modelling languages. This work applies the BWW theory to a real world example in the health arena. The general practice computing group data model was developed using the Barker Entity Relationship Modelling technique. We describe an experiment, grounded in ontological theory, which evaluates how well the GPCG data model is understood by domain experts. The results show that with the exception of the use of entities to represent events, the raw model is better understood by domain experts