938 resultados para 300503 Epidemiology


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE. To identify risk factors associated with nosocomial bloodstream infections caused by multiple clones of the staphylococcal cassette chromosome mec (SCCmec) type IV strain of methicillin-resistant Staphylococcus aureus (MRSA). DESIGN. An unmatched case-control study (at a ratio of 1 : 2) performed during the period from October 2002 through September 2003. SETTING. A 2,000-bed tertiary care teaching hospital affiliated with the University of Sao Paulo in Sao Paulo, Brazil. METHODS. Case patients (n = 30) were defined either as patients who had a bloodstream infection due to SCCmec type IV strains of MRSA diagnosed at least 48 hours after hospital admission or as neonates with the infection who were born in the hospital. Control patients (n = 60) were defined as patients with SCCmec type III MRSA infection diagnosed at least 48 hours after hospital admission. Genes n = 60 encoding virulence factors were studied in the isolates recovered from case patients, and molecular typing of the SCCmec type IV MRSA isolates was also done by pulsed-field gel electrophoresis and multilocus sequence typing. RESULTS. In multivariate analysis, the following 3 variables were significantly associated with having a nosocomial bloodstream infection caused by SCCmec type IV strains of MRSA: an age of less than 1 year, less frequent use of a central venous catheter (odds ratio [OR], 0.07 [95% confidence interval {CI}, 0.02-0.28]; P = .001), and female sex. A second analysis was performed that excluded the case and Pp. 001 control patients from the neonatal unit, and, in multivariate analysis, the following variables were significantly associated with having a nosocomial bloodstream infection caused by SCCmec type IV strains of MRSA: less frequent use of a central venous catheter (OR, 0.12 [95% CI, 0.03-0.55]; P = .007), lower Acute Physiology and Chronic Health Evaluation II score on admission (OR, 0.14 [95% CI, 0.03-0.61];), less frequent surgery (OR, 0.21 [95% CI, 0.06-0.83];), and female sex (OR, 5.70 [95% CI, 1.32-24.66]; P =.020). P = .009 Pp. 025 Pp). Of the 29 SCCmec type IV MRSA isolates recovered from case patients, none contained the Panton-Valentine leukocidin, gamma-hemolysin, enterotoxin B or C, or toxic shock syndrome toxin-1. All of the isolates contained genes for the LukE-LukD leukocidin and alpha-hemolysin. Genes for enterotoxin A were present in 1 isolate, and genes for beta-hemolysin were present in 3 isolates. CONCLUSIONS. ""Classical"" risk factors do not apply to patients infected with the SCCmec type IV strain of MRSA, which is an important cause of nosocomial bacteremia. This strain infects a patient population that is less ill and has had less frequent invasive procedures than a patient population infected with the multidrug-resistant strain of SCCmec type III MRSA. We found that virulence factors were rare and that Panton-Valentine leukocidin was absent. There were multiple clones of the SCCmec type IV strain in our hospital. Children under 1 year of age were at a higher risk. There was a predominant clone ( sequence type 5) in this patient population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Severe infections caused by Stenotrophomonas maltophilia are associated with high mortality, and strategies to improve the clinical outcome for infected patients are needed. A retrospective cohort study of patients with bloodstream infection (BSIs) and pneumonia caused by S. maltophilia was conducted. Multivariate analysis was performed to access factors associated with 14-day mortality. A total of 60 infections were identified. Among these, eight (13%) were pneumonias and 52 were BSIs; 33.3% were primary, 13% were central venous catheter (CVC)-related and 40% were secondary BSIs. Fifty-seven (85%) patients had received previous antimicrobial therapy; 88% had CVC, 57% mechanical ventilation and 75% were in the intensive care unit at the onset of infection. Malignancy (45%) was the most frequent underlying disease. The mean of the Acute Physiology and Chronic Health Evaluation II (APACHE II) scores was 17 and for the Sepsis-related Organ Failure Assessment (SOFA) score, it was 7 points. The overall and 14-day mortality were, respectively, 75% and 48%. Forty-seven (78%) patients were treated and, of these, 74% received trimethoprim-sulfamethoxazole. Independent risk factors associated with mortality were SOFA index > 6 points (0.005) and septic shock (0.03). The Kaplan-Meier estimations curves showed that patients with APACHE II score > 20 and SOFA score > 10 had a survival chance of, respectively, less than 8% and less than 10% (P <= 0.001) at 21 days after the first positive S. maltophilia culture. Our results suggest that the independent factors associated with outcome in patients with infection caused by S. maltophilia are septic shock and higher SOFA index.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Several medical devices used during hemodynamic procedures, particularly angiographic diagnostic and therapeutic cardiac catheters, are manufactured for single use only. However, reprocessing and reuse of these devices has been reported, to determine the frequency of reuse and reprocessing of single-use medical devices used during hemodynamic procedures in Brazil and to evaluate how reprocessing is performed. Design. National survey, conducted from December 1999 to July 2001. Methods. Most of the institutions affiliated with the Brazilian Society of Hemodynamic and Interventional Cardiology were surveyed by use of a questionnaire sent in the mail. Results. The questionnaire response rate was 50% (119 of 240 institutions). Of the 119 institutions that responded, 116 (97%) reported reuse of single-use devices used during hemodynamic procedures, and only 26 (22%) reported use of a standardized reprocessing protocol. Cleaning, flushing, rinsing, drying, sterilizing and packaging methods varied greatly and were mostly inadequate. Criteria for discarding reused devices varied widely. Of the 119 institutions that responded, 80 (67%) reported having a surveillance system for adverse events associated with the reuse of medical devices, although most of these institutions did not routinely review the data, and only 38 (32%) described a training program for the personnel who reprocessed single-use devices. Conclusions. The reuse of single-use devices used during hemodynamic procedures was very frequent in hospitals in Brazil. Basic guidance on how to reuse and reprocess single-use medical devices is urgently needed, because, despite the lack of studies to support reusing and reprocessing single-use medical devices, such devices are necessary in limited-resource areas in which these practices are current.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kaposi`s sarcoma-associated herpesvirus (KSHV) is endemic in the Amazon and rare in southern regions of Brazil. However, geographical distribution and epidemiological correlates of infection in this large country are still poorly defined. To estimate the seroprevalence of, and risk factors for, KSHV infection in Brazil, a multi-center study was conducted among 3,493 first-time voluntary unpaid blood donors from Salvador, Sao Paulo and Manaus. Antibodies against KSHV were detected using a whole-virus ELISA validated prior to the serosurvey. Antibodies against the latency-associated nuclear antigen (LANA) were detected by immuno-fluorescence assay (IFA) among ELISA-positive sera and a random sample of ELISA-negative sera. Overall, seroprevalence of KSHV by whole-virus ELISA was 21.7% (95% confidence interval (Cl): 20-23.4%) in men and 31.7% (95% Cl: 29-34.3%) in women (P<0.0001). KSHV antibodies were detected by IFA-LANA in 3% (95% Cl: 2-4.3%) of 867 ELISA-positive samples and in none of 365 randomly selected ELISA-negative samples. In multivariate analysis, KSHV seroprevalence by whole-virus ELISA was independently associated with female sex (odds ratio [OR] = 1.6, 95% Cl: 1.4-1.9); residence in the Amazon (OR = 1.4, 95% Cl: 1.2-1.8; compared to Salvador); Caucasian ethnicity (OR = 1.3, 95% Cl: 1.1-1.6) and herpes simplex virus type 2 (HSV-2) infection (OR = 1.3, 95% Cl: 1.1-1.6). KSHV seroprevalence did not significantly increase with age, nor was it associated with self-reported sexual behavior. KSHV seroprevalence is high among Brazilian blood donors, particularly from the Amazon region. This study supports the co-existence of sexual and non-sexual routes of KSHV transmission in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate nosocomial infections due to imipenem-resistant and imipenem-susceptible Pseudomonas aeruginosa, a case-control study that included genotyping was performed. Hospitalization for more than 15 days was independently associated with infection with an imipenem-resistant organism. Sixty-seven percent of the imipenem-resistant isolates analyzed and 23% of the imipenem-susceptible isolates analyzed belonged to a single clone. Intervention led to a decrease in the number of infections due to imipenem-resistant and imipenem-susceptible P. aeruginosa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

objective. To describe the management of patients with long-term central venous catheters (CVCs) during an outbreak of infection due to Pseudomonas putida and Stenotrophomonas maltophilia associated with contaminated heparin catheter-lock solution. design. Descriptive study. setting. Private, 250-bed tertiary-care hospital. methods. In March 2003, we identified 2 febrile cancer patients with P. putida bacteremia. Over 2 days, 7 cases of bacteremia were identified; lots of syringes prefilled with heparin catheter-lock solution, supplied by a compounding pharmacy, were recalled and samples were cultured. More cases of bacteremia appeared during the following days, and any patient who had had a catheter lock infused with the suspect solution was asked to provide blood samples for culture, even if the patient was asymptomatic. Isolates that were recovered from culture were typed by pulsed-field gel electrophoresis. Antimicrobial salvage treatment of long-term CVCs was attempted. results. A total of 154 patients had had their catheter lock infused with solution from the lots that were suspected of being contaminated. Only 48 of these patients had CVCs. By day 7 of the outbreak, 18 of these patients had become symptomatic. Twenty-six of the remaining 30 asymptomatic patients then also provided blood samples for culture, 10 of whom developed fever shortly after samples were collected. Thirty-two patients were identified who had P. putida bacteremia; 9 also had infection due to S. maltophilia. Samples from 1 of the 3 lots of prefilled syringes in use at the time of the outbreak also grew P. putida on culture. Molecular typing identified 3 different clones of P. putida from patients and heparin catheter-lock solution, and 1 clone of S. maltophilia. A total of 27 patients received antimicrobial therapy regimens, some of which included decontamination of the catheter lock with anti- infective lock solution. Of 27 patients, 19 (70%) retained their long-term CVC during the 6-month follow-up period. conclusions. To our knowledge, this is one of the largest prospective experiences in the management of bloodstream infection associated with long-term CVCs. The infections were caused by gram-negative bacilli and were managed without catheter removal, with a high response rate. We emphasize the risks of using intravenous formulations of medications supplied by compounding pharmacies that produce large quantities of drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Candidemia is associated with high morbidity and mortality resulting in significant increases in the length of patients` hospitalization and in healthcare costs. Critically ill patients are at particular risk for candidemia because of their debilitated condition and frequent need for invasive procedures. The aim of this study was to characterize the incidence and epidemiology of candidemia over a seven-year period in intensive care units (ICUs) and the use of fluconazole and caspofungin in a large university-affiliated hospital. All cases of candidemia were identified by surveillance, using the Centers for Diseases Control and Prevention criteria. Demographic variables, use of antifungal (fluconazole and caspofungin) and patient outcomes were evaluated. The 2 test for linear trend was employed to evaluate the distribution of Candida spp. and the use of fluconazole and caspofungin by defined daily dose (DDD) per 1,000 patients-days during the study period. One hundred and eight episodes of candidemia were identified. The overall incidence of candidemia (P=0.20) and incidence of non-Candida albicans Candida infections (P=0.32) remained stable over the study period and ranged from 0.3-0.9 episodes per 1,000 catheter-days and 0.39-0.83 episodes per 1,000 patients-days. However, the use of fluconazole and caspofungin increased significantly (P0.001). While there were no reports of the use of fluconazole for prophylaxis in 1999, its use for this purpose increased from 3% in 2000 to 7.0% (P=0.07) in 2006. C. albicans was the most frequent specie isolated and burns and cancer were the most frequent underlying conditions. The overall mortality was 76%. There was no difference between C. albicans and non-C. albicans Candida infections when the crude and 14-day mortality rates were compared. Our data demonstrated that C. albicans is still the most frequent species causing candidemia in our intensive care units. Our rates of candidemia are lower than those reported from the region and similar to American and European hospitals. Although the incidence of blood stream infections (BSI) and candidemia remained stable, the use of fluconazole and caspofungin increased significantly over the years included in this study but had no impact on the incidence of infections caused by non-C. albicans Candida species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a retrospective observational study of clinical and epidemiologic data from bloodstream yeast infections over 5 years (2004-2008) in a tertiary-care hospital. During this period, there were 52 such infections, at a rate of 2.4 per 1,000 hospital admissions. Non-C. albicans Candida species and other genera were responsible for 82% of infections, with C. tropicalis and C. parapsilosis being the most common. In 2008 no C. albicans infections occurred. Several uncommon fungal pathogens were observed, including Trichosporon asahii, Rhodotorula spp. and Candida zeylanoides. Of 16 isolates tested, 3 (19%) were resistant to fluconazole, including one C. zeylanoides (MIC 8 mu g/ml) and one C. tropicalis (MIC 16 mu g/ml) isolate, as well as intrinsically resistant C. krusei. All isolates tested were susceptible to itraconazole (n = 7) and amphotericin B (n = 8). Yeast infections were associated with severe underlying diseases, mainly hematological/solid cancers (71%), hospitalization in the ICU (41%), central venous catheters (80%), and use of antimicrobials (94%). The overall mortality rate was 50%. Our finding of a predominance of non-C. albicans Candida species infection with uncommon yeasts, and fluconazole resistance, suggests the need for continuous surveillance of fungemia and of antibiotic susceptibility trends, in order to adopt treatment strategies applicable to particular healthcare institutions.