993 resultados para 204-1251G


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isotope shifts of Kα1 x-ray transitions were measured for the Neodymium isotopes Nd 142, 143, 144, 145, 146, 148 and 150, the Samarium isotopes Sm 147, 148, 149, 150, 152 and 154, the Gadolinium isotopes Gd 154, 155, 156, 157, 158 and 160, the Dysprosium isotopes Dy 162 and 164, the Erbium isotopes Er 166, 168 and 170, the Hafnium isotopes Hf 178 and 180 and the Lead isotopes Pb 204, 206, 207 and 208. A curved crystal Cauchois spectrometer was used. The analysis of the measurement furnished the variation of the mean square charge radius of the nucleus, δ˂r2˃, for 23 isotope pairs. The experimental results were compared with theoretical values from nuclear models. Combining the x-ray shifts and the optical shifts in Nd and Sm yielded the optical mass shifts. An anomaly was observed in the odd-even shifts when the optical and the x-ray shifts were plotted against each other.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os pacientes hospitalizados, acamados ou restritos ao leito, apresentam uma gama de fatores de risco para o desenvolvimento das úlceras por pressão, diante disso, necessitam de uma assistência de enfermagem qualificada e eficaz na prevenção dessas lesões, a fim de evitar o desenvolvimento das mesmas. Desta forma, a pesquisa teve como objetivo investigar a influência da ação educativa junto à equipe de enfermagem das enfermarias de Clínica Médica na prevenção das úlceras por pressão. Tratou-se de um estudo quantitativo com delineamento descritivo com dispositivo de intervenção do tipo antes e depois, tendo como cenário as enfermarias de Clínica Médica de um hospital universitário na cidade do Rio de Janeiro. Os sujeitos foram os enfermeiros (n=15) e técnicos de enfermagem (n=18) da Clínica Médica e a unidade de medida do estudo foi o número de vezes que as ações de enfermagem, referentes à prevenção das úlceras por pressão e desempenhadas pelos sujeitos, foram observadas pela pesquisadora. Obtivemos 396 observações antes da ação educativa e 204 depois da ação educativa. A pesquisa apresentou três etapas: observação sistematizada antes da ação educativa, realização da ação educativa e observação sistematizada depois da ação educativa. Os resultados foram obtidos através da análise dos Check list antes e depois da ação educativa e constatamos, por meio de valores percentuais, melhoras significativas. A categoria sempre, considerada o valor ideal para todas as variáveis, apresentou aumento de 20 pontos percentuais entre as observações; a categoria frequentemente apresentou aumento de 07 pontos e a categoria raramente apresentou decréscimo de 27 pontos. Isso demonstra que a ação educativa atingiu o objetivo de sensibilizar a equipe de enfermagem quanto a prevenir as úlceras por pressão de forma qualificada. Concluímos que as úlceras por pressão continuam sendo um grande problema de saúde pública, merecendo atenção especial por parte da equipe de enfermagem. Acreditamos que a ação educativa é capaz de sensibilizar a equipe de enfermagem e motivar a transformação das ações e condutas, porém, ela é pontual e é apenas uma parte do processo educacional. Para alcançarmos a mudança comportamental e proporcionar uma assistência qualificada e eficiente aos pacientes em risco de desenvolver as úlceras por pressão, sugerimos o desenvolvimento de uma prática educativa contínua e permanente, capaz de manter a equipe de enfermagem em constante aperfeiçoamento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The parameters such as quantum yield and molar absorption coefficients of the photoinitiator that are responsible for holographic sensitivity in photopolymer material are investigated with a single beam exposure experiment. The influence of exposure intensity, the concentrations of N-phenylglycine and dye on the photobleaching process of xanthenes dyes are presented. In addition, the effect of diphenyliodonium hexafluorophosphate salt on the quantum yield and molar absorption of xanthene dyes is studied. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The FOB-3, anew type fiber optic biosensor, is designed to rapidly detect a variety of biological agents or analytes with better stability, sensitivity and specificity. In order to detect Y. Pestis, a sandwich immunoassay was developed by using the purified antibody against antigen FI immobilized on polystyrene probes as the capture antibody and the monoclonal antibody-Cy5 conjugate as the detector. After a series of optimization for the stability, sensitivity and specificity of the FOB-3, 50-1000 ng/ml of antigen FI and 6 x 10(1)-6 x 10(7) CFU/ml Y. pestis could be detected constantly in about 20 min, and Y pestis could be detected specifically from Y. pseudotuberculosis, Y. enterocolitica, B. anthracis and E. coli. Then, 39 blind samples, including 27 tissues of mice infected with Y pestis and 12 tissues of healthy mice as negative control, were detected with the FOB-3. 92.6% infected tissues were identified from the tissues of healthy mice and the tissues containing more than 100 CFU/ml bacteria could be detected by the biosensor. The results demonstrated the feasibility of the FOB-3 as an effective method to detect Y. pestis rapidly and directly from the infected animal specimens with the advantage of portability, simple-operation as well as high sensitivity and specificity. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This publication is an up-to-date review of the papers published by the researchers of the Oceanographic Research Center of Abidjan, since its beginnings (1958-1978).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Composite sapphire/Ti:sapphire crystals for high-power laser application were grown by the hydrothermal method. The results of the X-ray rocking curve analysis indicate high crystalline quality of the surface Al2O3 material. The strong bonding between the overgrown Al2O3 and seed Ti:Al2O3 crystals is indispensable for withstanding high thermal stresses produced by intense optical pumping. The optical loss at the boundary of the composite crystal is considerably low, indicating the lack of scattering centers. (c) 2005 Elsevier B.V. All rights reserved.