963 resultados para ultrasound ct
Resumo:
Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.
Resumo:
OBJECTIVE: We explored the potential for patients with proven venous thromboembolism or pulmonary embolism (PE) to have occult malignancies detected during the same CT examination. To verify this, we compared the presence of occult malignancies identified on pulmonary artery CT angiography (CTA) and CT venography (CTV) when venous thromboembolism (VTE) was present. SUBJECTS AND METHODS: Pulmonary artery CTA combined with CTV was performed on a 16-MDCT scanner on 186 adult patients suspected of having pulmonary embolism without any known malignancies. CTV was performed from the diaphragm to the knee 180 seconds after CTA. Two radiologists evaluated the presence of VTE, that is PE or deep venous thrombosis (DVT), and tumor lesions on both examinations in consensus. The malignant nature of the possibly identified tumors was confirmed by pathologic examination. RESULTS: VTE was found in 49 patients (26%). Malignant tumors were detected in 24 patients (13%). Eleven patients with malignant tumors had VTE (46% of patients with malignant tumors; 22% with VTE and 6% of all patients). There was correlation with presence of malignancies between both and DVT and DVT associated with PE but not between presence of malignancies and PE only. Patients with DVT and those with DVT associated with PE had a risk ratio of 3.2 and 3.3, respectively, for having a malignant tumor discovered simultaneously. CONCLUSION: A high number of malignant tumors can be incidentally discovered on pulmonary artery CTA, even more so with additional CTV. Radiologists should scrutinize scans to pick up unknown malignancies, especially in patients with identified VTE.
Resumo:
PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.
Resumo:
PURPOSE: To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS: All patients gave written informed consent after the study details, including radiation exposure, were explained. The study protocol was approved by the local institutional review board. In patients referred for elective conventional coronary angiography, an additional 64-section CT angiography study and a myocardial perfusion imaging study (1-day adenosine stress-rest protocol) with technetium 99m-tetrofosmin SPECT were performed before conventional angiography. Coronary artery diameter narrowing of 50% or greater at CT angiography was defined as stenosis and was compared with the myocardial perfusion imaging findings. Quantitative coronary angiography served as a reference standard for CT angiography. RESULTS: A total of 1093 coronary segments in 310 coronary arteries in 78 patients (mean age, 65 years +/- 9 [standard deviation]; 35 women) were analyzed. CT angiography revealed stenoses in 137 segments (13%) corresponding to 91 arteries (29%) in 46 patients (59%). SPECT revealed 14 reversible, 13 fixed, and six partially reversible defects in 31 patients (40%). Sensitivity, specificity, and negative and positive predictive values, respectively, of CT angiography in the detection of reversible myocardial perfusion imaging defects were 95%, 53%, 94%, and 58% on a per-patient basis and 95%, 75%, 96%, and 72% on a per-artery basis. Agreement between CT and conventional angiography was very good (96% and kappa = 0.92 for patient-based analysis, 93% and kappa = 0.84 for vessel-based analysis). CONCLUSION: Sixty-four-section CT angiography can help rule out hemodynamically relevant CAD in patients with intermediate to high pretest likelihood, although an abnormal CT angiography study is a poor predictor of ischemia.
Resumo:
PURPOSE: To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64-section CT and conventional coronary angiography. Fifty additional patients (19 women, 31 men; mean age, 59.2 years +/- 13.2) who underwent CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. RESULTS: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P < .001). With CT, a significant correlation was not found between systolic compression and length (r = 0.16, P = .25, n = 150) but was found with depth (r = 0.65, P < .01, n = 150) of the tunneled segment. In 14 patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P < .001, P < .01, and P < .001, respectively). CONCLUSION: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length.
Resumo:
BACKGROUND: Bronchopulmonary sequestration is a lung malformation characterized by nonfunctioning lung tissue without primary communication with the tracheobronchial tree. Intrauterine complications such as mediastinal shift, pleural effusion or fetal hydrothorax can be present. We present the case of a newborn with bilateral intralobar pulmonary sequestration. METHODS: Prenatal ultrasonography in a primigravida at 20 weeks of gestation revealed echogenic masses in the right fetal hemithorax with mediastinal shift towards the left side. Serial ultrasound confirmed persistence of the lesion with otherwise appropriate fetal development. Delivery was uneventful and physical examination revealed an isolated intermittent tachypnea. Chest CT scan and CT angiography showed a bilateral intrathoracic lesion with arterial supply from the aorta. Baby lung function testing suggested possible multiple functional compartments. RESULTS: Right and left thoracotomy was performed at the age of 7 months. A bilateral intralobar sequestration with vascularisation from the aorta was resected. Pathological and histological examination of the resected tissue confirmed the surgical diagnosis. At the age of 24 months, the child was doing well without pulmonary complications. CONCLUSIONS: Bilateral pulmonary sequestration requires intensive prenatal and postnatal surveillance. Though given the fact of a bilateral pulmonary sequestration, postnatal outcome showed similar favourable characteristics to an unilateral presentation. Baby lung function testing could provide additional information for optimal postnatal management and timing of surgical intervention.
Resumo:
In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.
Resumo:
BACKGROUND: Although urinalysis is simple and inexpensive to perform, the finding of microhaematuria on urinalysis may be unreliable for diagnosing urolithiasis. OBJECTIVE: To evaluate microhaematuria as a diagnostic marker for urolithiasis compared with low-dose unenhanced multidetector computed tomography (MDCT) as the "gold standard". SETTING: A level 1 emergency department in a tertiary referral university teaching hospital. DESIGN: Retrospective analysis. METHODS: A study was undertaken to assess whether the finding of microhaematuria was diagnostic for urolithiasis using a low-dose unenhanced MDCT-based diagnosis as the reference standard by reviewing the records of all patients who presented to the emergency department with colicky flank pain and underwent a CT scan between January 2003 and December 2005. RESULTS: Urolithiasis was present (as defined by low-dose unenhanced MDCT) in 507/638 patients (79%); 341/638 (53%) were true positive for urolithiasis, 76 (12%) were true negative, 55 (9%) were false positive and 166 (26%) were false negative. Microhaematuria as a test for urolithiasis in patients presenting to the emergency department therefore has a sensitivity, specificity, positive predictive value and negative predictive value of 67%, 58%, 86% and 31%, respectively. 58% of the urinalysis results were negative for haematuria in the subset of patients with significant alternative diagnoses. CONCLUSIONS: The sensitivity, specificity and negative predictive value of microhaematuria on urinalysis for urolithiasis using unenhanced MDCT as the reference standard were low. This suggests that, when urolithiasis is clinically suspected, unenhanced MDCT is indicated without urinalysis being a prerequisite.
Resumo:
Purpose: Development of an interpolation algorithm for re‐sampling spatially distributed CT‐data with the following features: global and local integral conservation, avoidance of negative interpolation values for positively defined datasets and the ability to control re‐sampling artifacts. Method and Materials: The interpolation can be separated into two steps: first, the discrete CT‐data has to be continuously distributed by an analytic function considering the boundary conditions. Generally, this function is determined by piecewise interpolation. Instead of using linear or high order polynomialinterpolations, which do not fulfill all the above mentioned features, a special form of Hermitian curve interpolation is used to solve the interpolation problem with respect to the required boundary conditions. A single parameter is determined, by which the behavior of the interpolation function is controlled. Second, the interpolated data have to be re‐distributed with respect to the requested grid. Results: The new algorithm was compared with commonly used interpolation functions based on linear and second order polynomial. It is demonstrated that these interpolation functions may over‐ or underestimate the source data by about 10%–20% while the parameter of the new algorithm can be adjusted in order to significantly reduce these interpolation errors. Finally, the performance and accuracy of the algorithm was tested by re‐gridding a series of X‐ray CT‐images. Conclusion: Inaccurate sampling values may occur due to the lack of integral conservation. Re‐sampling algorithms using high order polynomialinterpolation functions may result in significant artifacts of the re‐sampled data. Such artifacts can be avoided by using the new algorithm based on Hermitian curve interpolation
Resumo:
3D ultrasound can be used to study the fetal spine, but skeletal mode can be inconclusive for the diagnosis of fetal spina bifida. We illustrate a diagnostic approach using 2D and 3D ultrasound and indicate possible pitfalls.
Resumo:
Three-dimensional (3D) ultrasound volume acquisition, analysis and display of fetal structures have enhanced their visualization and greatly improved the general understanding of their anatomy and pathology. The dynamic display of volume data generally depends on proprietary software, usually supplied with the ultrasound system, and on the operator's ability to maneuver the dataset digitally. We have used relatively simple tools and an established storage, display and manipulation format to generate non-linear virtual reality object movies of prenatal images (including moving sequences and 3D-rendered views) that can be navigated easily and interactively on any current computer. This approach permits a viewing or learning experience that is superior to watching a linear movie passively.