924 resultados para sampling methods
Resumo:
PURPOSE To determine the prevalence of amblyopia, anisometropia, and strabismus in schoolchildren of Shiraz, Iran. MATERIALS AND METHODS A random cluster sampling was used in a cross-sectional study on schoolchildren in Shiraz. Cycloplegic refraction was performed in elementary and middle school children and high school students had non-cylcoplegic refraction. Uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) were recorded for each participant. Anisometropia was defined as spherical equivalent (SE) refraction difference 1.00D or more between two eyes. Amblyopia was distinguished as a reduction of BCVA to 20/30 or less in one eye or 2-line interocular optotype acuity differences in the absence of pathological causes. Cover test was performed for investigating of strabismus. RESULTS Mean age of 2638 schoolchildren was 12.5 years (response rate = 86.06%). Prevalence of anisometropia was 2.31% (95% confidence interval [CI], 1.45 to 3.16). 2.29% of schoolchildren (95% CI, 1.46 to 3.14) were amblyopic. The prevalence of amblyopia in boys and girls was 2.32% and 2.26%, respectively (p = 0.945). Anisometropic amblyopia was found in 58.1% of the amblyopic subjects. The strabismus prevalence was 2.02% (95% CI, 1.18 to 2.85). The prevalence of exotropia and esotropia was 1.30% and 0.59%, respectively. CONCLUSIONS Results of this study showed that the prevalence of anisometropia, amblyopia, and strabismus are in the mid range. The etiology of amblyopia was often refractive, mostly astigmatic, and non-strabismic. Exotropia prevalence increased with age and was the most common strabismus type.
Resumo:
PURPOSE To determine the prevalence of refractive errors in Shiraz schoolchildren by age and gender. METHODS For this cross-sectional study, random cluster sampling was carried out from students of the 2008-2009 academic year. After the initial interview, ophthalmic examinations including tests of visual acuity, non-cycloplegic and cycloplegic refraction and binocular vision were performed. Myopia was defined as a spherical equivalent < or =-0.50 dioptre (D), hyperopia as > or =+2.0 D, and astigmatism as a cylinder refraction > or =0.75 D. All values for school grade and gender were directly standardized based on the total student population in the 2008-2009 school year. RESULTS A total of 2130 students were sampled, of which 1872 participated in the study (response rate = 87.88%). The prevalence of uncorrected, best-corrected, presenting and spectacle corrected visual acuity of 6/12 or worse in the better eye was 6.46%, 0%, 1.49% and 0.9%, respectively. The prevalence rates of myopia, hyperopia and astigmatism were 4.35% (95% confidence interval [CI]: 2.89-5.82%), 5.04% (95% CI: 3.50-6.58%), and 11.27% (95% CI: 9.81-12.74%), respectively. Anisometropia was detected in 2.58% of schoolchildren. The prevalence of hyperopia significantly decreased with age (P = 0.021). CONCLUSIONS Compared with other reported rates, the prevalence of myopia in the schoolchildren of Shiraz is similar to that in most places excluding East Asian countries, and that of hyperopia is in the mid range.
Resumo:
Purpose: To determine the prevalence and risk factors of refractive errors among schoolchildren in Shiraz, Iran. Methods: In a cross-sectional study, using random cluster sampling, 3065 Shiraz schoolchildren were selected in this study. The participants totaled 2683; 1872 elementary and middle school and 811 high school students. For the primary and middle schoolchildren, cycloplegic refraction and for the high school students, non-cycloplegic autorefraction was measured. Myopia, defined as spherical equivalent (SE) refraction -0.50 diopter (D) or worse, hyperopia as SE +2.00D and +0.50D or more for cycloplegic and noncycloplegic refractions respectively, and astigmatism as cylinder -0.75D or worse. Results: The prevalence of refractive errors in elementary and middle school students was: myopia 4.35 % (95% confidence interval (CI), 2.89 -5.81), hyperopia 5.04 % (95%CI, 3.49 -6.58) and astigmatism 11.79 % (95%CI, 10.21 -13.38). For high school students, these rates were 22.4 % (95%CI, 18.44 -26.36), 10.52 % (95%CI, 6.75 -14.29) and 20.99% (95%CI, 16.55 -25.44), respectively.The prevalence of myopia increased with age in primary and middle school students (OR=1.15, 95% CI, 0.98 to1.33, p=0.073). Conclusions: The result of this study indicated a relatively low prevalence of refractive errors among schoolchildren in Shiraz according to the protocol by "Refractive Error Study in Children" (RESC) in other investigations.
Resumo:
This thesis examined the use of acoustic sensors for monitoring avian biodiversity. Acoustic sensors have the potential to significantly increase the spatial and temporal scale of ecological observations, however acoustic recordings of the environment can be opaque and complex. This thesis developed methods for analysing large volumes of acoustic data to maximise the detection of bird species, and compared the results of acoustic sensor biodiversity surveys with traditional bird survey techniques.
Resumo:
BACKGROUND Ongoing shortages of blood products may be addressed through additional donations. However, donation frequency rates are typically lower than medically possible. This preliminary study aims to determine voluntary nonremunerated whole blood (WB) and plasmapheresis donors' willingness, and subsequent facilitators and barriers, to make additional donations of a different type. STUDY DESIGN AND METHODS Forty individual telephone interviews were conducted posing two additional donation pattern scenarios: first, making a single and, second, making multiple plasmapheresis donations between WB donations. Stratified purposive sampling was conducted for four samples varying in donation experience: no-plasma, new-to-both-WB-and-plasma, new-to-plasma, and plasma donors. Interviews were analyzed yielding excellent (κ values > 0.81) inter-rater reliability. RESULTS Facilitators were more endorsed than barriers for a single but not multiple plasmapheresis donation. More new-to-both donors (n = 5) were willing to make multiple plasma donations between WB donations than others (n = 1 each) and identified fewer barriers (n = 3) than those more experienced in donation (n = 8 no plasma, n = 10 new to both, n = 11 plasma). Donors in the plasma sample were concerned about the subsequent reduced time between plasma donations by adding WB donations (n = 3). The no-plasma and new-to-plasma donors were concerned about the time commitment required (n = 3). CONCLUSION Current donors are willing to add different product donations but donation history influences their willingness to change. Early introduction of multiple donation types, variation in inventory levels, and addressing barriers will provide blood collection agencies with a novel and cost-effective inventory management strategy.
Resumo:
Objective This paper presents an automatic active learning-based system for the extraction of medical concepts from clinical free-text reports. Specifically, (1) the contribution of active learning in reducing the annotation effort, and (2) the robustness of incremental active learning framework across different selection criteria and datasets is determined. Materials and methods The comparative performance of an active learning framework and a fully supervised approach were investigated to study how active learning reduces the annotation effort while achieving the same effectiveness as a supervised approach. Conditional Random Fields as the supervised method, and least confidence and information density as two selection criteria for active learning framework were used. The effect of incremental learning vs. standard learning on the robustness of the models within the active learning framework with different selection criteria was also investigated. Two clinical datasets were used for evaluation: the i2b2/VA 2010 NLP challenge and the ShARe/CLEF 2013 eHealth Evaluation Lab. Results The annotation effort saved by active learning to achieve the same effectiveness as supervised learning is up to 77%, 57%, and 46% of the total number of sequences, tokens, and concepts, respectively. Compared to the Random sampling baseline, the saving is at least doubled. Discussion Incremental active learning guarantees robustness across all selection criteria and datasets. The reduction of annotation effort is always above random sampling and longest sequence baselines. Conclusion Incremental active learning is a promising approach for building effective and robust medical concept extraction models, while significantly reducing the burden of manual annotation.
Resumo:
Background Concordance is characterised as a negotiation-like health communication approach based on an equal and collaborative partnership between patients and health professionals. The Leeds Attitudes to Concordance II (LATCon II) scale was developed to measure the attitudes towards concordance. The purpose of this study was to translate the LATCon II into Chinese and psychometrically test the Chinese version of LATCon II (C-LATCon II). Methods The study involved three phases: i) translation and cross-cultural adaptation; ii) pilot study, and; iii) a cross-sectional survey (n = 366). Systematic random sampling was used to recruit hypertensive patients from nine communities covering around 78,000 residents in China. Tests of psychometric properties included content validity, construct validity, criteria-related validity (correlation between the C-LATCon II and the Therapeutic Adherence Scale for Hypertensive Patients (TASHP)), internal reliability, and test-retest reliability (n = 30). Results The study found that the C-LATCon II had a satisfactory content validity (item-level Content Validity Index (CVI) = 0.83-1, scale-level CVI/universal agreement = 0.89, and scale-level CVI/averaging calculation = 0.98), construct validity (four components extracted explained 56.66% of the total variance), internal reliability (Cronbach’s alpha of overall scale and four components was 0.78 and 0.66-0.84, respectively), and test-retest reliability (Pearson’s correlation coefficient = 0.82, p < 0.001; interclass correlation coefficient = 0.82, p < 0.001; linear weighted kappa3 statistic for each item = 0.40-0.65, p < 0.05). Criteria-related validity showed a weak association (Pearson’s correlation coefficient = 0.11, p < 0.05) between patients’ attitudes towards concordance during health communication and their health behaviours for hypertension management. Conclusions The C-LATCon II is a validated and reliable instrument which can be used to evaluate the attitudes to concordance in Chinese populations. Four components (health professionals’ attitudes, partnership between two parties, therapeutic decision making, and patients’ involvement) describe the attitudes towards concordance during health communication.
Resumo:
This paper presents the results of a research project aimed at examining the capabilities and challenges of two distinct but not mutually exclusive approaches to in-service bridge assessment: visual inspection and installed monitoring systems. In this study, the intended functionality of both approaches was evaluated on its ability to identify potential structural damage and to provide decision-making support. Inspection and monitoring are compared in terms of their functional performance, cost, and barriers (real and perceived) to implementation. Both methods have strengths and weaknesses across the metrics analyzed, and it is likely that a hybrid evaluation technique that adopts both approaches will optimize efficiency of condition assessment and ultimately lead to better decision making.
Resumo:
Blasting is an integral part of large-scale open cut mining that often occurs in close proximity to population centers and often results in the emission of particulate material and gases potentially hazardous to health. Current air quality monitoring methods rely on limited numbers of fixed sampling locations to validate a complex fluid environment and collect sufficient data to confirm model effectiveness. This paper describes the development of a methodology to address the need of a more precise approach that is capable of characterizing blasting plumes in near-real time. The integration of the system required the modification and integration of an opto-electrical dust sensor, SHARP GP2Y10, into a small fixed-wing and multi-rotor copter, resulting in the collection of data streamed during flight. The paper also describes the calibration of the optical sensor with an industry grade dust-monitoring device, Dusttrak 8520, demonstrating a high correlation between them, with correlation coefficients (R2) greater than 0.9. The laboratory and field tests demonstrate the feasibility of coupling the sensor with the UAVs. However, further work must be done in the areas of sensor selection and calibration as well as flight planning.