958 resultados para photorefractive and semiconductor materials


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purposes of this study were to describe the demographics of abstracts presented at the prosthodontics section of IADR General Sessions from 2004 to 2005, evaluate the publication rate of abstracts, and analyze the relationship between variables in abstracts and publication.Materials and Methods: Prosthodontics research section abstracts from the IADR General Session in 2004 and 2005 were evaluated for: number of authors, presentation type, origin, affiliation, topic, study design, statistics, study outcome, and funding. The publication rate was calculated following a PubMed search. The journal of publication, year of publication, and the length of time before publication were analyzed. Descriptive statistics were used for the data analysis; the relationships between presentation type, study design, study outcome, statistics, funding, and publication were analyzed using logistic regression (alpha = 0.05).Results: From 346 abstracts, 37.0% were published. For oral presentations, 40.7% were published; 35.8% of poster presentations were published. The mean duration before publicationwas 26.4months. North America had themost abstracts, and Europe had the most publications. Fixed prosthodontic research had the highest number and proportion for publication. A significant association with publication was noted for neutral study outcomes (p = 0.018), studies with funding (p = 0.035), and abstracts from Europe (p = 0.001).Conclusions: The majority of abstracts from the prosthodontics research section of IADR General Sessions from 2004 and 2005 remain unpublished. A significant association for publication was noted with neutral outcomes, funding, and abstracts from Europe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE ( PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The restoration and recovery of a compromised skull continues to be a challenge to craniofacial surgeons and neurosurgeons. Different operative techniques and implant materials are being used to reconstruct the rigid framework of the skull. However, no currently available materials satisfy all of these criteria. According to this premise, the aim of this study was to report on the currently available materials for the reconstruction of the cranial vault and to describe their main characteristics, advantages, and disadvantages. Although the use of the materials discussed in this study is clearly positive for the reconstruction of skull defects and cranioplasties, there is a need for more complex studies and research into developing these materials to achieve all the ideal prerequisites stipulated by the scientific community and to evaluate their properties and aesthetic and functional results in the long term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This work intended to investigate, by means of a literature revision, the techniques and materials used for the rehabilitation of hemimandibular defect patients, prosthetic and occlusal aspects of these patients, and chewing and swallowing.Materials and Methods: For the confection of this revision, we consulted the database indexers Google Scholar, PubMed, and SciELO and found studies published between the periods 1972 and 2008. The terms used for the search had been "to hemimandibular defects," "to temporomandibular joint protheses," and "vascularized cap grafts," which had been searched separately and combined.Conclusions: Diverse techniques and materials used for the reconstruction of hemimandibular defects exist; however, great bone resorption is still observed, which will compromise the prosthetic rehabilitation of these patients. More prospective works and stories of clinical cases duly registered will be able to elucidate in a clearer form the anatomic and functional devolutions of the verbal socket of hemimandibular defect patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of a prolonged erosive pH cycling on the superficial microhardness change (SMHC) and the erosive wear of different restorative materials. Eighty enamel specimens with prepared cavities of 1.5 x 1.5 mm were randomly divided into eight groups according to the restorative materials used for the fillings (RMGI - resin-modified glass-ionomer, CGI - conventional glass-ionomer, CR- composite resin, A - amalgam) and immersion media used (ERO - erosive medium or SAL - artificial saliva). During 35 days, half of the specimens were immersed in a cola drink (ERO), for 5 min, three times a day, and they remained in SAL between the erosive cycles. The other half of the specimens was immersed in SAL only, for the entire experimental period (control). Data were tested for significant differences by anova and Tukey's tests (P < 0.05). Scanning electron microscopy images were made to illustrate the enamel erosive wear and restorative materials alterations. The mean SMHC (%) and mean erosive wear (mu m) of the materials were: RMGI-ERO (30/0.5); CGI-ERO (37/0.5); CR-ERO (-0.3/0.3); A-ERO (-4/0.3); RMGI-SAL (4/0.4); CGI-SAL (-6/0.4); CR-SAL (-3/0.2) and A-SAL (2/0.4). Scanning electron microscopy images showed pronounced enamel erosive wear on groups submitted to erosive pH cycling when compared with groups maintained in saliva. In conclusion, the prolonged pH cycling promoted significantly higher alterations (SMHC and erosive wear) on the glass-ionomer cements than the CR and amalgam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

in the city of Limeira, southeastern Brazil, an important exposure of Permian sediments of the Parana basin was revealed by an open pit mine that exploits limestone for production of soil correction compounds and raw materials for the ceramic industry. The radioactivity of these sediments was investigated in some detail and the results provided a general view of the vertical distributions of uranium, thorium and potassium concentrations and of the element ratios U/K, U/Th and Th/K. In general, the concentrations of the main natural radioactive elements are low, with uranium being enriched in some limestone and shale levels. In addition the results showed that the U-238 series is in radioactive disequilibrium in many of the analyzed samples. Although the origin of the observed disequilibrium has not been investigated, the results suggest that it is due to weathering processes and water interaction with the rock matrix. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the fabrication of relief diffraction gratings recorded on a surface of photosensitive Ga10Ge25S65 and Ga5Ge25As5S65 glasses by means of interference of two UV laser beams at 351 nm. The diffraction efficiency (eta) of first diffraction order was measured. Atomic-force-microscope (AFM) was used to perform a 3D imaging analysis of the sample surface topography that shows the superposition of an imprinted grating over the topography of the glass. The change in the absorption edge and the refractive index has been evaluated and a structural approach of the relief grating on the glass surface has been discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The erbium-based manganite ErMnO3 has been partially substituted at the manganese site by the transition-metal elements Ni and Co. The perovskite orthorhombic structure is found from x(Ni) = 0.2-0.5 in the nickel-based solid solution ErNixMn1-xO3, while it can be extended up to x(Co) = 0.7 in the case of cobalt, provided that the synthesis is performed under oxygenation conditions to favor the presence of Co3+. Presence of different magnetic entities (i.e., Er3+, Ni2+, Co2+, Co3+, Mn3+, and Mn4+) leads to quite unusual magnetic properties, characterized by the coexistence of antiferromagnetic and ferromagnetic interactions. In ErNixMn1-xO3, a critical concentration x(crit)(Ni) = 1/3 separates two regimes: spin-canted AF interactions predominate at x < x(crit), while the ferromagnetic behavior is enhanced for x > x(crit). Spin reversal phenomena are present both in the nickel- and cobalt-based compounds. A phenomenological model based on two interacting sublattices, coupled by an antiferromagnetic exchange interaction, explains the inversion of the overall magnetic moment at low temperatures. In this model, the ferromagnetic transition-metal lattice, which orders at T-c, creates a strong local field at the erbium site, polarizing the Er moments in a direction opposite to the applied field. At low temperatures, when the contribution of the paramagnetic erbium sublattice, which varies as T-1, gets larger than the ferromagnetic contribution, the total magnetic moment changes its sign, leading to an overall ferrimagnetic state. The half-substituted compound ErCo0.50Mn0.50O3 was studied in detail, since the magnetization loops present two well-identified anomalies: an intersection of the magnetization branches at low fields, and magnetization jumps at high fields. The influence of the oxidizing conditions was studied in other compositions close to the 50/50 = Mn/Co substitution rate. These anomalies are clearly connected to the spin inversion phenomena and to the simultaneous presence of Co2+ and Co3+ magnetic moments. Dynamical aspects should be considered to well identify the high-field anomaly, since it depends on the magnetic field sweep rate. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.