978 resultados para photon echo
Resumo:
OBJECTIVE: The purpose of this study is to evaluate the impact of transeophageal echocardiography on management of patients at low-risk for cardiogenic embolism to prevent new potential cardiovascular sources of emboli. METHODS: We studied 69 patients with ischemic stroke at low-risk for cardiogenic embolism. Transeophageal echocardiography was performed to access: left atrium enlargement; communication or aneurysm of the interatrial septum; patent foramen ovale; spontaneous echo contrast or intracavitary thrombi; the presence of intraaortic atherosclerotic plaques or thrombi; significant valvar morphologic alteration or dysfunction; left ventricle enlargement, hypertrophy, or contractile abnormality. Transesophageal echocardiography altered clinical management, and we adopted anticoagulant therapy or another procedure apart from the use of acetylsalicylic acid. RESULTS: Transeophageal echocardiography detected at least one abnormality in 40 cases (58%). Clinical conduct was adjusted after the performance of transesophageal echocardiography in 11 patients (15.9%); anticoagulation was added in 10 cases and surgical correction in one patient. CONCLUSION: Transeophageal echocardiography was a very useful tool in the secondary prevention for stroke in patients at low risk for cardiogenic embolism.
Resumo:
OBJECTIVE: To evaluate prior mitral surgical commissurotomy and echocardiographic score influence on the outcomes and complications of percutaneous mitral balloon valvuloplasty. METHODS: We performed 459 complete mitral valvuloplasty procedures. Four hundred thirteen were primary valvuloplasty and 46 were in patients who had undergone prior surgical commissurotomy. The prior commissurotomy group was older, had higher echo scores, and a tendency toward a higher percentage of atrial fibrillation. RESULTS: When the groups were compared with each other, no differences were found in pre- and postprocedure mean pulmonary artery pressure, mean mitral gradient, mitral valve area, and mitral regurgitation . Because we found no significant differences, we subdivided the entire group based on echo scores, those with echo scores <=8 and those with echo scores >8 the mitral valve area being higher in the <=8 echo score group 2.06±0.42 versus 1.90±0.40cm² (p=0.0090) in the >8 echo score group. CONCLUSION: Dividing the groups based on echo score revealed that the higher echo score group had smaller mitral valve areas postvalvuloplasty.
Resumo:
OBJETIVO: Avaliar a correlação e concordância entre medidas ecocardiográficas das dimensões cardíacas, obtidas através do aplicativo Echo off-line (programa para obtenção de medidas de imagens digitalizadas em estação de trabalho dedicada), com as realizadas convencionalmente. MÉTODOS: Estudo transversal, contemporâneo, sendo randomizados 56 pacientes. Através do programa Echo off-line foram mensuradas as medidas ao modo M e 2D ao nível dos ventrículos, do átrio esquerdo e da aorta. Estas medidas foram comparadas às realizadas por outro profissional, através do teste de correlação de Pearson (r), com alfa crítico de 0,05 e pela análise de concordância (Bland e Altman). RESULTADOS: As mensurações realizadas no sistema Echo off-line demonstraram r de 0,85 a 0,98. A análise de concordância mostrou que, para a maioria das medidas, a diferença média entre os métodos foi aproximadamente zero. A variação de valores absolutos não apresentou, em média, significância clínica. O aplicativo Echo off-line permite uma redução de, aproximadamente, 30% no tempo para realização das medidas. CONCLUSÃO: Este trabalho demonstrou a acurácia do programa Echo off-line para mensurar as dimensões cardíacas em estação de trabalho dedicada, podendo ser utilizado rotineiramente nos laboratórios de ecocardiografia.
Resumo:
Se estudiará el comportamiento de moléculas sonda aromáticas flourescentes en micelas inversas de AOT y BHDC y en soluciones de polielectrolitos y mezclas de polielectrolitos y detergentes. Se espera obtener información sobre la estructura de los sistemas microheterogéneos y cómo esta estructura afecta la formación de iones radicales obtenidos a partir de reacciones entre moléculas sonda y moléculas donoras o aceptoras de electrones. Las técnicas a emplear incluyen espectroscopía de absorción y emisión, láser flash fotólisis, flourescencia pulsada por láseres y time correlated single photon counting. Objetivos generales y específicos: 1. Fotofísica y fotoquímica en micelas inversas. 1.1. Exciplejos en micelas inversas. 1.2. Rendimientos de estados electrónicos triplete en micelas inversas. 1.3. Comportamiento de ftalocianinas y porfirinas en micelas inversas. 2. Soluciones de polielectrolitos y mezclas de polielectrolitos con detergentes. 2.1. Reacciones fotoinducidas. 2.2. Comportamiento de derivados de porfirinas y ftalocianinas. 3. Montaje de la técnica de Time Correlated Single Photn Counting. 4. Montaje de un equipo adicional de laser flash fotólisis. 5. Síntesis de derivados solubles en agua de porfirinas y ftalocianinas.
Resumo:
Magnetic resonance imaging, diffusion-weighted imaging, image distortions, eddy currents, echo planar imaging
Resumo:
FRET-FLIM, ENERGY TRANSFER, LIFETIME, DECAY ASSOCIATED SPECTRUM, DAS, KINASE, MAGUKS, SINGLE PHOTON COUNTING, PICOSECOND-TIME RESOLVED FLUORESCENCE SPECTROSCOPY, GFP, CFP, YFP, TOPAZ, NANOMETER, MICROSCOPY, LYMPHOCYTES, LCK, SAP97
Resumo:
AbstractBackground:Heart failure with preserved ejection fraction is a syndrome characterized by changes in diastolic function; it is more prevalent among the elderly, women, and individuals with systemic hypertension (SH) and diabetes mellitus. However, in its early stages, there are no signs of congestion and it is identified in tests by adverse remodeling, decreased exercise capacity and diastolic dysfunction.Objective:To compare doppler, echocardiographic (Echo), and cardiopulmonary exercise test (CPET) variables - ergospirometry variables - between two population samples: one of individuals in the early stage of this syndrome, and the other of healthy individuals.Methods:Twenty eight outpatients diagnosed with heart failure according to Framingham’s criteria, ejection fraction > 50% and diastolic dysfunction according to the european society of cardiology (ESC), and 24 healthy individuals underwent Echo and CPET.Results:The group of patients showed indexed atrial volume and left ventricular mass as well as E/E’ and ILAV/A´ ratios significantly higher, in addition to a significant reduction in peak oxygen consumption and increased VE/VCO2 slope, even having similar left ventricular sizes in comparison to those of the sample of healthy individuals.Conclusion:There are significant differences between the structural and functional variables analyzed by Echo and CPET when comparing two population samples: one of patients in the early stage of heart failure with ejection fraction greater than or equal to 50% and another of healthy individuals.
Resumo:
AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.
Frequency of Cardiovascular Involvement in Familial Amyloidotic Polyneuropathy in Brazilian Patients
Resumo:
Background:Familial amyloidotic polyneuropathy (FAP) is a rare disease diagnosed in Brazil and worldwide. The frequency of cardiovascular involvement in Brazilian FAP patients is unknown.Objective:Detect the frequency of cardiovascular involvement and correlate the cardiovascular findings with the modified polyneuropathy disability (PND) score.Methods:In a national reference center, 51 patients were evaluated with clinical examination, electrocardiography (ECG), echocardiography (ECHO), and 24-hour Holter. Patients were classified according to the modified PND score and divided into groups: PND 0, PND I, PND II, and PND > II (which included PND IIIa, IIIb, and IV). We chose the classification tree as the statistical method to analyze the association between findings in cardiac tests with the neurological classification (PND).Results:ECG abnormalities were present in almost 2/3 of the FAP patients, whereas ECHO abnormalities occurred in around 1/3 of them. All patients with abnormal ECHO also had abnormal ECG, but the opposite did not apply. The classification tree identified ECG and ECHO as relevant variables (p < 0.001 and p = 0.08, respectively). The probability of a patient to be allocated to the PND 0 group when having a normal ECG was over 80%. When both ECG and ECHO were abnormal, this probability was null.Conclusions:Brazilian patients with FAP have frequent ECG abnormalities. ECG is an appropriate test to discriminate asymptomatic carriers of the mutation from those who develop the disease, whereas ECHO contributes to this discrimination.
Resumo:
Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2012
Resumo:
Die Bachelorarbeit behandelt die Schätzung der Parameter von Fluoreszenzlebensdauerfunktionen mit Hilfe des EM-Algorithmus. Dabei wird der Algorithmus sowohl auf simulierte als auch auf gemessene Daten angewandt. Die Schätzung der Parameter erfolgt zunächst global für die gesamte Probe mit Hilfe eines Simplex-Verfahrens, um dann das Verhältnis der Komponenten der Fluoreszenzlebensdauer, also die Wahrscheinlichkeit, mit der ein Photon von einer Komponente stammt, für jedes Pixel eines Bildes durch den EM-Algorithmus zu bestimmen. Die Messungen liegen als Anzahl der gemessenen Photonen in diskreten Zeitintervallen vor, dabei fehlt jedoch die Information, wie viele der Photonen in einem der Intervalle zu einer Komponente gehören. Durch die Nutzung bedingter Erwartungswerte ist der EM-Algorithmus in der Lage, ohne Verzerrung mit diesen unbekannten Daten umzugehen. Weiterhin wird die Schätzung dadurch erschwert, dass die Daten durch Faltung der Fluoreszenzlebensdauerfunktion mit einer so genannten Apparatefunktion zustandekommen und das Modell somit sehr komplex wird. Auch für dieses Problem wird im Laufe der Arbeit eine Lösung vorgestellt.
Resumo:
Estudi elaborat a partir d’una estada a la Universitat de Aarhus, Dinamarca, durant juliol 2006. En el present treball s’investiguen, per primer cop, les propietats de absorció bifotòniques del fotosensibilitzador 2,7,12,17-tetrafenilporficè (TPPo) i del seu complex de pal•ladi (II) (PdTPPo). Ambos compostos han rebut molta atenció com a possibles otosensibilitzadors per a Teràpia Fotodinàmica (TFD). S’utilitza la detecció de la fosforescència de l’oxigen singlet, centrada a 1270 nm i produïda per l’absorció de dos fotons, per quantificar la magnitud de la secció d’absorció bifotònica, "delta", dels porficèns estudiats. Els experiments se han dut a terme en el marge espectral 750-850 nm i a l’infraroig proper a 1100nm. Aquestes longituds d’ona corresponen a les zones d’absorció bifotònica en les bandes de Soret i Q. Les propietats bifotòniques obtingudes es comparen i contrasten amb les dades conegudes de la tetrafenilporfirina (TPP), isòmer estructural del tetrafenilporficè però amb més gran simetria, i es troba que en la banda de Soret (que coincideix amb la regió de la pell més transparent) els valors de delta per el TPPo i PdTPPo son aproximadament 2000 GM en el màxim, pràcticament cent vegades més grans que per la TPP. A més a més, aquestos valors son dos ordres de magnitud més grans que els obtinguts a l’irradiar a 1100 nm (bandes Q). Aquestes observacions es poden explicar mitjançant la amplificació per ressonància deguda a la presència de transicions monofotòniques ressonants en la regió de les bandes Q. Els elevats valors de "delta" obtinguts per els tetrafenilporficèns estudiats junt a les principals característiques que aquestos presenten (elevat rendiment de formació d’oxigen singlet, estabilitat química i fotoquímica, absència de citotoxicitat,...) qualifiquen al TPPo y PdTPPo com a possibles fotosensibilitzadors per a Teràpia Fotodinàmica Bifotònica.
Resumo:
PURPOSE: To determine the value of applying finger trap distraction during direct MR arthrography of the wrist to assess intrinsic ligament and triangular fibrocartilage complex (TFCC) tears. MATERIALS AND METHODS: Twenty consecutive patients were prospectively investigated by three-compartment wrist MR arthrography. Imaging was performed with 3-T scanners using a three-dimensional isotropic (0.4 mm) T1-weighted gradient-recalled echo sequence, with and without finger trap distraction (4 kg). In a blind and independent fashion, two musculoskeletal radiologists measured the width of the scapholunate (SL), lunotriquetral (LT) and ulna-TFC (UTFC) joint spaces. They evaluated the amount of contrast medium within these spaces using a four-point scale, and assessed SL, LT and TFCC tears, as well as the disruption of Gilula's carpal arcs. RESULTS: With finger trap distraction, both readers found a significant increase in width of the SL space (mean Δ = +0.1mm, p ≤ 0.040), and noticed more contrast medium therein (p ≤ 0.035). In contrast, the differences in width of the LT (mean Δ = +0.1 mm, p ≥ 0.057) and UTFC (mean Δ = 0mm, p ≥ 0.728) spaces, as well as the amount of contrast material within these spaces were not statistically significant (p = 0.607 and ≥ 0.157, respectively). Both readers detected more SL (Δ = +1, p = 0.157) and LT (Δ = +2, p = 0.223) tears, although statistical significance was not reached, and Gilula's carpal arcs were more frequently disrupted during finger trap distraction (Δ = +5, p = 0.025). CONCLUSION: The application of finger trap distraction during direct wrist MR arthrography may enhance both detection and characterisation of SL and LT ligament tears by widening the SL space and increasing the amount of contrast within the SL and LT joint spaces.
Resumo:
INTRODUCTION: Hip fractures are responsible for excessive mortality, decreasing the 5-year survival rate by about 20%. From an economic perspective, they represent a major source of expense, with direct costs in hospitalization, rehabilitation, and institutionalization. The incidence rate sharply increases after the age of 70, but it can be reduced in women aged 70-80 years by therapeutic interventions. Recent analyses suggest that the most efficient strategy is to implement such interventions in women at the age of 70 years. As several guidelines recommend bone mineral density (BMD) screening of postmenopausal women with clinical risk factors, our objective was to assess the cost-effectiveness of two screening strategies applied to elderly women aged 70 years and older. METHODS: A cost-effectiveness analysis was performed using decision-tree analysis and a Markov model. Two alternative strategies, one measuring BMD of all women, and one measuring BMD only of those having at least one risk factor, were compared with the reference strategy "no screening". Cost-effectiveness ratios were measured as cost per year gained without hip fracture. Most probabilities were based on data observed in EPIDOS, SEMOF and OFELY cohorts. RESULTS: In this model, which is mostly based on observed data, the strategy "screen all" was more cost effective than "screen women at risk." For one woman screened at the age of 70 and followed for 10 years, the incremental (additional) cost-effectiveness ratio of these two strategies compared with the reference was 4,235 euros and 8,290 euros, respectively. CONCLUSION: The results of this model, under the assumptions described in the paper, suggest that in women aged 70-80 years, screening all women with dual-energy X-ray absorptiometry (DXA) would be more effective than no screening or screening only women with at least one risk factor. Cost-effectiveness studies based on decision-analysis trees maybe useful tools for helping decision makers, and further models based on different assumptions should be performed to improve the level of evidence on cost-effectiveness ratios of the usual screening strategies for osteoporosis.