978 resultados para paleo-CO(2) proxy
Endothelin inhibition improves cerebral blood flow and is neuroprotective in pneumococcal meningitis
Resumo:
By using an infant rat model of pneumococcal meningitis, we determined whether endothelins contribute to neuronal damage in this disease. Cerebrospinal fluid analysis demonstrated a significant increase of endothelin-1 in infected animals compared with uninfected controls. Histopathological examination 24 hours after infection showed brain damage in animals treated with ceftriaxone alone (median, 9.2% of cortex; range, 0-49.1%). In infected animals treated intraperitoneally with the endothelin antagonist bosentan (30 mg/kg, every 12 hours) also, injury was reduced to 0.5% (range, 0-8.6%) of cortex. Cerebral blood flow was reduced in infected animals (6.5 +/- 4.0 ml/min/100 g of brain vs 14.9 +/- 9.1 ml/min/100 g in controls. Treatment with bosentan restored cerebral blood flow to levels similar to controls (12.8 +/- 5.3 ml/min/100 g). Improved blood flow was not mediated by nitric oxide production, because bosentan had no effect on cerebrospinal fluid or plasma nitrite/nitrate concentrations at 6, 12, or 18 hours. These data indicate that endothelins contribute to neuronal injury in this model of pneumococcal meningitis by causing cerebral ischemia.
Resumo:
While the benefits of intensified insulin treatment in insulin-dependent (Type 1) diabetes mellitus (IDDM) are well recognized, the risks have not been comprehensively characterized. We examined the risk of severe hypoglycaemia, ketoacidosis, and death in a meta-analysis of randomized controlled trials. The MEDLINE database, reference lists, and specialist journals were searched electronically or by hand to identify relevant studies with at least 6 months of follow-up and the monitoring of glycaemia by glycosylated haemoglobin measurements. Logistic regression was used for calculation of combined odds ratios and 95% confidence intervals (95% CI). The influence of covariates was examined by including covariate-by-treatment interaction terms. Methodological study quality was assessed and sensitivity analyses were performed. Fourteen trials were identified. These contributed 16 comparisons with 1028 patients allocated to intensified and 1039 allocated to conventional treatment. A total of 846 patients suffered at least one episode of severe hypoglycaemia, 175 patients experienced ketoacidosis and 26 patients died. The combined odds ratio (95% CI) for hypoglycaemia was 2.99 (2.45-3.64), for ketoacidosis 1.74 (1.27-2.38) and for death from all causes 1.40 (0.65-3.01). The risk of severe hypoglycaemia was determined by the degree of normalization of glycaemia achieved (p=0.005 for interaction term), with the results from the Diabetes Control and Complications Trial (DCCT) in line with the other trials. Ketoacidosis risk depended on the type of intensified treatment used. Odds ratios (95% CI) were 7.20 (2.95-17.58) for exclusive use of pumps, 1.13 (0.15-8.35) for multiple daily injections and 1.28 (0.90-1.83) for trials offering a choice between the two (p = 0.004 for interaction). Mortality was significantly (p = 0.007) increased for causes potentially associated with acute complications (7 vs 0 deaths, 5 deaths attributed to ketoacidosis, and 2 sudden deaths), and non-significantly (p = 0.16) decreased for macrovascular causes (3 vs 8 deaths). We conclude that there is a substantial risk of severe adverse effects associated with intensified insulin treatment. Mortality from acute metabolic causes is increased; however, this is largely counterbalanced by a reduction in cardiovascular mortality. The excess of severe hypoglycemia in the DCCT is not exceptional. Multiple daily injection schemes may be safer than treatment with insulin pumps.
Resumo:
PURPOSE: To elucidate the association of impaired pulmonary status (IPS) and diabetes mellitus (DM) with clinical outcome and the incidences of aortic neck dilatation and type I endoleak after elective endovascular infrarenal aortic aneurysm repair (EVAR). METHODS: In 164 European institutions participating in the EUROSTAR registry, 6383 patients (5985 men; mean age 72.4+/-7.6 years) underwent EVAR. Patients were divided into patients without versus with IPS or with/without DM. Clinical assessment and contrast-enhanced computed tomography (CT) were performed at 1, 3, 6, 12, 18, and 24 months and annually thereafter. Cumulative endpoint analysis comprised death, aortic rupture, type I endoleak, endovascular reintervention, and surgical conversion. RESULTS: Prevalence of IPS was 2733/6383 (43%) and prevalence of DM was 810/6383 (13%). Mean follow-up was 21.1+/-18.4 months. Thirty-day mortality, AAA rupture, and conversion rates did not differ between patients with versus without IPS and between patients with versus without DM. All-cause and AAA-related mortality, respectively, were significantly higher in patients with IPS compared to patients with normal pulmonary status (31.0% versus 19.0%, p<0.0001 and 6.8% versus 3.3%, p = 0.0057) throughout follow-up. In multivariate analysis adjusted for smoking, age, gender, comorbidities, fitness for open repair, co-existing common iliac aneurysm, neck and aneurysm size, arterial angulations, aneurysm classification, endograft oversizing >or=15%, and type of stent-graft, the presence of IPS was not associated with significantly higher rates of aortic neck dilatation (30.6% versus 38.0%, p>0.05) and did not influence cumulative rates of type I endoleak, endovascular reintervention, or conversion to open surgery (p>0.05). Similarly, the presence of DM did not influence the above-mentioned study endpoints. CONCLUSION: In contrast to observations regarding the natural course of AAAs, impaired pulmonary status does not negatively influence aortic neck dilatation, while the presence of diabetes does not protect from these dismal events after EVAR.
Resumo:
The water spider Argyroneta aquatica (Clerck) is the only spider that spends its whole life under water. Water spiders keep an air bubble around their body for breathing and build under-water air bells, which they use for shelter and raising offspring, digesting and consuming prey, moulting, depositing eggs and sperm, and copulating. It is unclear whether these bells are an important oxygen reservoir for breathing under water, or whether they serve mainly to create water-free space for feeding and reproduction. In this study, we manipulated the composition of the gas inside the bell of female water spiders to test whether they monitor the quality of this gas, and replenish oxygen if required. We exchanged the entire gas in the bell either with pure O(2), pure CO(2), or with ambient air as control, and monitored behavioural responses. The test spiders surfaced and replenished air more often in the CO(2) treatment than in the O(2) treatment, and they increased bell building behaviour. In addition to active oxygen regulation, they monitored and adjusted the bells by adding silk. These results show that water spiders use the air bell as an oxygen reservoir, and that it functions as an external lung, which renders it essential for living under water permanently. A. aquatica is the only animal that collects, transports, and stores air, and monitors its property for breathing, which is an adaptive response of a terrestrial animal to the colonization of an aquatic habitat. J. Exp. Zool. 307A:549-555, 2007. (c) 2007 Wiley-Liss, Inc.
Resumo:
This study with 31 obese binge eaters (body mass index [BMI] 39.5+/-8.6 kg/m(2) [SD]) was designed to assess whether diet counseling with psychological support and imipramine or placebo has an effect on the frequency of binge eating, body weight, and depression during an 8-week treatment phase. This was followed by an open medication-free phase of 6 months of continuous diet counseling with psychological support.
Resumo:
The work presented in this dissertation deals with the coordination chemistry of the bis(benzyl)phosphinate ligand with vanadium, tungsten and cobalt. The long term goal of this project was to produce and physically characterize high oxidation state transition metal oxide phosphinate compounds with potential catalytic applications. The reaction of bis(benzyl)phosphinic acid with VO(acac)2 in the presence of water or pyridine leads to the synthesis of trimeric vanadium(IV) clusters (V3(µ3-O)O2)(µ2-O2P(CH2C6H5)2)6(H2O) and (V3(µ3-O)O2)(µ2-O2P(CH2C6H5)2)6(py). In contrast, when diphenylphosphinic acid or 2-hydroxyisophosphindoline-2-oxide were reacted with VO(acac)2, insoluble polymeric compounds were produced. The trimeric clusters were characterized using FTIR, elemental analysis, single crystal diffraction, room temperature magnetic susceptibility, thermogravimetric analysis and differential scanning calorimetry. The variable-temperature, solid-state magnetic susceptibility was measured on (V3(µ3-O)O2)(µ2-O2P(CH2C6H5)2)6(py). The polymeric compounds were characterized using FTIR, powder diffraction and elemental analysis. Two different cubane clusters made of tungsten(V) and vanadium(V) were stabilized using bis(benzyl)phosphinate. The oxidation of (V3(µ3-O)O2)(µ2-O2P(CH2C6H5)2)6(H2O) with tBuOOH led to the formation of V4(µ3-O)4(µ2-O2P(Bn)2)4(O4). W4(µ3-O)4(µ2-O2P(Bn)2)4(O4) was produced by heating W(CO)6 in a 1:1 mixture of EtOH/THF at 120 ˚C. Both compounds were characterized using single crystal diffraction, FTIR, 31P-NMR, 1H-NMR and elemental analysis. W4(µ3-O)4(µ2-O2P(Bn)2)4(O4) was also characterized using UV-vis. Cobalt(II) reacted with bis(benzyl)phosphinate to produce three different dinuclear complexes. [(py)3Co(µ2-O2P(Bn)2)3Co(py)][ClO4], (py)3Co(µ2-O2P(Bn)2)3Co(Cl) and (py)(µ2-NO3)Co(µ2-O2P(Bn)2)3Co(py) were all characterized using single crystal diffraction, elemental analysis and FTIR. Room temperature magnetic susceptibility measurements were performed on [(py)3Co(µ2-O2P(Bn)2)3Co(py)][ClO4] and (py)3Co(µ2-O2P(Bn)2)3Co(Cl). The variable-temperature, solid-state magnetic susceptibility was also measured on [(py)3Co(µ2-O2P(Bn)2)3Co(py)][ClO4].
Resumo:
Two of the indicators of the UN Millennium Development Goals ensuring environmental sustainability are energy use and per capita carbon dioxide emissions. The increasing urbanization and increasing world population may require increased energy use in order to transport enough safe drinking water to communities. In addition, the increase in water use would result in increased energy consumption, thereby resulting in increased green-house gas emissions that promote global climate change. The study of multiple Municipal Drinking Water Distribution Systems (MDWDSs) that relates various MDWDS aspects--system components and properties--to energy use is strongly desirable. The understanding of the relationship between system aspects and energy use aids in energy-efficient design. In this study, components of a MDWDS, and/or the characteristics associated with the component are termed as MDWDS aspects (hereafter--system aspects). There are many aspects of MDWDSs that affect the energy usage. Three system aspects (1) system-wide water demand, (2) storage tank parameters, and (3) pumping stations were analyzed in this study. The study involved seven MDWDSs to understand the relationship between the above-mentioned system aspects in relation with energy use. A MDWDSs model, EPANET 2.0, was utilized to analyze the seven systems. Six of the systems were real and one was a hypothetical system. The study presented here is unique in its statistical approach using seven municipal water distribution systems. The first system aspect studied was system-wide water demand. The analysis involved analyzing seven systems for the variation of water demand and its impact on energy use. To quantify the effects of water use reduction on energy use in a municipal water distribution system, the seven systems were modeled and the energy usage quantified for various amounts of water conservation. It was found that the effect of water conservation on energy use was linear for all seven systems and that all the average values of all the systems' energy use plotted on the same line with a high R 2 value. From this relationship, it can be ascertained that a 20% reduction in water demand results in approximately a 13% savings in energy use for all seven systems analyzed. This figure might hold true for many similar systems that are dominated by pumping and not gravity driven. The second system aspect analyzed was storage tank(s) parameters. Various tank parameters: (1) tank maximum water levels, (2) tank elevation, and (3) tank diameter were considered in this part of the study. MDWDSs use a significant amount of electrical energy for the pumping of water from low elevations (usually a source) to higher ones (usually storage tanks). The use of electrical energy has an effect on pollution emissions and, therefore, potential global climate change as well. Various values of these tank parameters were modeled on seven MDWDSs of various sizes using a network solver and the energy usage recorded. It was found that when averaged over all seven analyzed systems (1) the reduction of maximum tank water level by 50% results in a 2% energy reduction, (2) energy use for a change in tank elevation is system specific, and (2) a reduction of tank diameter of 50% results in approximately a 7% energy savings. The third system aspect analyzed in this study was pumping station parameters. A pumping station consists of one or more pumps. The seven systems were analyzed to understand the effect of the variation of pump horsepower and the number of booster stations on energy use. It was found that adding booster stations could save energy depending upon the system characteristics. For systems with flat topography, a single main pumping station was found to use less energy. In systems with a higher-elevation neighborhood, however, one or more booster pumps with a reduced main pumping station capacity used less energy. The energy savings for the seven systems was dependent on the number of boosters and ranged from 5% to 66% for the analyzed five systems with higher elevation neighborhoods (S3, S4, S5, S6, and S7). No energy savings was realized for the remaining two flat topography systems, S1, and S2. The present study analyzed and established the relationship between various system aspects and energy use in seven MDWDSs. This aids in estimating the amount of energy savings in MDWDSs. This energy savings would ultimately help reduce Greenhouse gases (GHGs) emissions including per capita CO 2 emissions thereby potentially lowering the global climate change effect. This will in turn contribute to meeting the MDG of ensuring environmental sustainability.
Resumo:
Notwithstanding non-robotic, thoracoscopic preparation of the internal mammary artery (IMA) is a difficult surgical task, an appropriate experimental training model is lacking. We evaluated the young domestic pig for this purpose. Four domestic female pigs (30-40 kg body weight) were used for this study. Bilateral thoracoscopic preparation of the IMA was carried out under continuous, pressure controlled CO(2) insufflation. A 30 degrees rigid thoracoscope was inserted through a 10-mm port in the 5th/6th intercostal space (ICS) dorsally to the posterior axillary line. The dissection instrument (Ultracision Harmonic Scalpel) was inserted (5-mm port) in the 7th ICS at the posterior axillary line and the endo-forceps (5-mm port) in the 5th ICS at the posterior axillary line. Thoracoscopic IMA preparation in pig resulted more difficult than in man. A total of seven IMAs were prepared in their full intrathoracic length. A change in the preparation technique (lateral detachment of the endothoracic muscle) improved the safety of the procedure, allowing all four respective IMAs to be prepared safely, while the initial technique ensued an injury for 2 out of 3 vessels. The described young domestic pig model is suitable for experimental training of bilateral thoracoscopic IMA preparation.
Resumo:
In adults, the term specific pulmonary renal syndrome describes disorders with pulmonary and glomerular manifestations and includes Wegener's granulomatosis, Goodpasture disease, and systemic lupus erythematosus. Nonspecific pulmonary renal syndrome refers to either pulmonary disease complicating glomerular disease, or glomerular diseases following pulmonary disease. Since little is known regarding pulmonary renal syndrome in childhood, we reviewed the charts of 21 pediatric patients with pulmonary renal syndromes treated by the Department of Pediatrics, University of Bern between 1991 and 1998; we also reviewed the pediatric literature that deals with specific pulmonary renal syndromes. Specific pulmonary renal syndrome was noted in 3 children with systemic vasculitis (Wegener granulomatosis, N = 2; microscopic polyangiitis, N = 1) and 2 with systemic lupus erythematosus. Nonspecific pulmonary renal syndrome was observed in 12 patients with pulmonary edema (N = 9), pulmonary thromboembolism (N = 2), and pulmonary infection (N = 1) complicating the course of a glomerular disease, and in 4 children with a pulmonary disease followed by a glomerular disease. Review of the literature disclosed 52 cases of specific pulmonary renal syndrome other than systemic lupus erythematosus: Wegener granulomatosis (N = 28), Goodpasture disease (N = 13), and Henoch-Schönlein purpura (N = 11). In addition, hemolytic uremic syndrome complicated pneumococcal pneumonia in 32 cases. We conclude that pulmonary renal syndromes need to be looked for in childhood. Apart from Wegener granulomatosis, Goodpasture disease, and systemic lupus erythematosus, Henoch-Schönlein purpura and hemolytic-uremic syndrome occasionally have both pulmonary and renal features.
Resumo:
This study evaluated the response to increasing levels of neurally adjusted ventilatory assist (NAVA), a mode converting electrical activity of the diaphragm (EAdi) into pressure, regulated by a proportionality constant called the NAVA level. Fourteen rabbits were studied during baseline, resistive loading and ramp increases of the NAVA level. EAdi, airway (Paw) and esophageal pressure (Pes), Pes pressure time product (PTPes), breathing pattern, and blood gases were measured. Resistive loading increased PTPes and EAdi. P(a)(CO)(2) increased with high load but not during low load. Increasing NAVA levels increased Paw until a breakpoint where the Paw increase was reduced despite increasing NAVA level. At this breakpoint, Pes, PTPes, EAdi, and P(a)(CO)(2) were similar to baseline. Further increase of the NAVA level reduced Pes, PTPes and EAdi without changes in ventilation. In conclusion, observing the trend in Paw during a ramp increase of the NAVA level allows determination of a level where the inspiratory effort matches unloaded conditions.