984 resultados para opto-electronic materials
Resumo:
OBJECTIVETo present the nurse's integration within materials management of six teaching hospitals of Paraná - Brazil, and to describe the activities performed by nurses within this process.METHODA study of a qualitative approach and descriptive nature, conducted in teaching hospitals in Paraná, between June and August of 2013. The data collection was conducted through semi-structured interviews with eight nurses who worked in materials management; data were analyzed using content analysis.RESULTSThese showed that nurses perform ten categories of activities, distributed into four of the five steps of the materials management process.CONCLUSIONThe nurse, in performing of these activities, in addition to favoring the development of participative management, contributes to the organization, planning, and the standardization of the hospital supply process, giving greater credibility to the work with professionals who use the materials, and to the suppliers.
Resumo:
The LSTA goals for Iowa, FY98-FY02, are as follows: 1. Provide all Iowans with expanded access to information and materials through the State of Iowa Libraries Online (SILO) network. 2. Improve library service to Iowans through knowledgeable, well-trained staff and wellinformed public library trustees and library users. 3. Meet Iowans’ increasing demands for information and library services by identifying and encouraging resource sharing and partnerships. 4. Provide state level leadership and services to accomplish the LSTA Five-Year Plan. The primary objectives of this evaluation are to provide: $ An assessment of the overall impact of Iowa’s LSTA funding and success in achieving the goals identified in the state’s five-year plan. $ An in-depth analysis of two specific goals from the plan: providing Iowans with expanded access to information and materials through the State of Iowa Libraries Online (SILO) network; and improving library service to Iowans through knowledgeable, well-trained staff and well-informed public library trustees and library users. LSTA built on accomplishments made possible with the federal HEA II-B grant awarded to the State Library in 1995. This grant led the way in bringing technology to Iowa libraries by creating an electronic library network for resource sharing. SILO (State of Iowa Libraries Online) became fully functional in 1997. The State Library continued funding SILO with LSTA money when the grant ended. This funding supports the SILO infrastructure, providing equitable access to information through cutting edge technology to Iowans in both small and large, rural and urban, communities. Access to electronic material and information has encouraged public libraries to increase the number of computers and public access to the Internet. LSTA funding was used to increase training opportunities for library staff and trustees. Many programs, such as librarian certification, were strengthened by an increase in continuing education opportunities.
Resumo:
The LSTA goals for Iowa, FY98-FY02, are as follows: 1. Provide all Iowans with expanded access to information and materials through the State of Iowa Libraries Online (SILO) network. 2. Improve library service to Iowans through knowledgeable, well-trained staff and wellinformed public library trustees and library users. 3. Meet Iowans’ increasing demands for information and library services by identifying and encouraging resource sharing and partnerships. 4. Provide state level leadership and services to accomplish the LSTA Five-Year Plan. The primary objectives of this evaluation are to provide: $ An assessment of the overall impact of Iowa’s LSTA funding and success in achieving the goals identified in the state’s five-year plan. $ An in-depth analysis of two specific goals from the plan: providing Iowans with expanded access to information and materials through the State of Iowa Libraries Online (SILO) network; and improving library service to Iowans through knowledgeable, well-trained staff and well-informed public library trustees and library users. LSTA built on accomplishments made possible with the federal HEA II-B grant awarded to the State Library in 1995. This grant led the way in bringing technology to Iowa libraries by creating an electronic library network for resource sharing. SILO (State of Iowa Libraries Online) became fully functional in 1997. The State Library continued funding SILO with LSTA money when the grant ended. This funding supports the SILO infrastructure, providing equitable access to information through cutting edge technology to Iowans in both small and large, rural and urban, communities. Access to electronic material and information has encouraged public libraries to increase the number of computers and public access to the Internet. LSTA funding was used to increase training opportunities for library staff and trustees. Many programs, such as librarian certification, were strengthened by an increase in continuing education opportunities.
Resumo:
The LSTA goals for Iowa, FY98-FY02, are as follows: 1. Provide all Iowans with expanded access to information and materials through the State of Iowa Libraries Online (SILO) network. 2. Improve library service to Iowans through knowledgeable, well-trained staff and wellinformed public library trustees and library users. 3. Meet Iowans’ increasing demands for information and library services by identifying and encouraging resource sharing and partnerships. 4. Provide state level leadership and services to accomplish the LSTA Five-Year Plan. The primary objectives of this evaluation are to provide: $ An assessment of the overall impact of Iowa’s LSTA funding and success in achieving the goals identified in the state’s five-year plan. $ An in-depth analysis of two specific goals from the plan: providing Iowans with expanded access to information and materials through the State of Iowa Libraries Online (SILO) network; and improving library service to Iowans through knowledgeable, well-trained staff and well-informed public library trustees and library users. LSTA built on accomplishments made possible with the federal HEA II-B grant awarded to the State Library in 1995. This grant led the way in bringing technology to Iowa libraries by creating an electronic library network for resource sharing. SILO (State of Iowa Libraries Online) became fully functional in 1997. The State Library continued funding SILO with LSTA money when the grant ended. This funding supports the SILO infrastructure, providing equitable access to information through cutting edge technology to Iowans in both small and large, rural and urban, communities. Access to electronic material and information has encouraged public libraries to increase the number of computers and public access to the Internet. LSTA funding was used to increase training opportunities for library staff and trustees. Many programs, such as librarian certification, were strengthened by an increase in continuing education opportunities.
Resumo:
OBJECT: To study a scan protocol for coronary magnetic resonance angiography based on multiple breath-holds featuring 1D motion compensation and to compare the resulting image quality to a navigator-gated free-breathing acquisition. Image reconstruction was performed using L1 regularized iterative SENSE. MATERIALS AND METHODS: The effects of respiratory motion on the Cartesian sampling scheme were minimized by performing data acquisition in multiple breath-holds. During the scan, repetitive readouts through a k-space center were used to detect and correct the respiratory displacement of the heart by exploiting the self-navigation principle in image reconstruction. In vivo experiments were performed in nine healthy volunteers and the resulting image quality was compared to a navigator-gated reference in terms of vessel length and sharpness. RESULTS: Acquisition in breath-hold is an effective method to reduce the scan time by more than 30 % compared to the navigator-gated reference. Although an equivalent mean image quality with respect to the reference was achieved with the proposed method, the 1D motion compensation did not work equally well in all cases. CONCLUSION: In general, the image quality scaled with the robustness of the motion compensation. Nevertheless, the featured setup provides a positive basis for future extension with more advanced motion compensation methods.
Resumo:
Differences in physico-chemical characteristics of bone grafts to fill bone defects have been demonstrated to influence in vitro bacterial biofilm formation. Aim of the study was to investigate in vivo staphylococcal biofilm formation on different calcium phosphate bone substitutes. A foreign-body guinea-pig infection model was used. Teflon cages prefilled with β-tricalcium phosphate, calcium-deficient hydroxyapatite, or dicalcium phosphate (DCP) scaffold were implanted subcutaneously. Scaffolds were infected with 2 × 10(3) colony-forming unit of Staphylococcus aureus (two strains) or S. epidermidis and explanted after 3, 24 or 72 h of biofilm formation. Quantitative and qualitative biofilm analysis was performed by sonication followed by viable counts, and microcalorimetry, respectively. Independently of the material, S. aureus formed increasing amounts of biofilm on the surface of all scaffolds over time as determined by both methods. For S. epidermidis, the biofilm amount decreased over time, and no biofilm was detected by microcalorimetry on the DCP scaffolds after 72 h of infection. However, when using a higher S. epidermidis inoculum, increasing amounts of biofilm were formed on all scaffolds as determined by microcalorimetry. No significant variation in staphylococcal in vivo biofilm formation was observed between the different materials tested. This study highlights the importance of in vivo studies, in addition to in vitro studies, when investigating biofilm formation of bone grafts.
Resumo:
Introduction: We launched an investigator-initiated study (ISRCTN31181395) to evaluate the potential benefit of pharmacokinetic-guided dosage individualization of imatinib for leukaemiapatients followed in public and private sectors. Following approval by the research ethics committee (REC) of the coordinating centre, recruitment throughout Switzerland necessitatedto submit the protocol to 11 cantonal RECs.Materials and Methods: We analysed requirements and evaluation procedures of the 12 RECs with associated costs.Results: 1-18 copies of the dossier, in total 4300 printed pages, were required (printing/posting costs: ~300 CHF) to meet initial requirements. Meeting frequencies of RECs ranged between 2 weeks and 2 months, time from submission to fi rst feedback took 2-75 days. Study approval was obtained from a chairman, a subor the full committee, the evaluation work being invoiced by0-1000 CHF (median: 750 CHF, total: 9200 CHF). While 5 RECs gave immediate approval, the other 6 rose in total 38 queries before study release, mainly related to wording in the patient information, leading to 7 different fi nal versions approved. Submission tasks employed an investigator half-time over about 6 months.Conclusion: While the necessity of clinical research evaluation by independent RECs is undisputed, there is a need of further harmonization and cooperation in evaluation procedures. Current administrative burden is indeed complex, time-consuming and costly. A harmonized electronic application form, preferably compatible with other regulatory bodies and European countries, could increase transparency, improve communication, and encourage academic multi-centre clinical research in Switzerland.
Resumo:
BACKGROUND AND PURPOSE: MCI was recently subdivided into sd-aMCI, sd-fMCI, and md-aMCI. The current investigation aimed to discriminate between MCI subtypes by using DTI. MATERIALS AND METHODS: Sixty-six prospective participants were included: 18 with sd-aMCI, 13 with sd-fMCI, and 35 with md-aMCI. Statistics included group comparisons using TBSS and individual classification using SVMs. RESULTS: The group-level analysis revealed a decrease in FA in md-aMCI versus sd-aMCI in an extensive bilateral, right-dominant network, and a more pronounced reduction of FA in md-aMCI compared with sd-fMCI in right inferior fronto-occipital fasciculus and inferior longitudinal fasciculus. The comparison between sd-fMCI and sd-aMCI, as well as the analysis of the other diffusion parameters, yielded no significant group differences. The individual-level SVM analysis provided discrimination between the MCI subtypes with accuracies around 97%. The major limitation is the relatively small number of cases of MCI. CONCLUSIONS: Our data show that, at the group level, the md-aMCI subgroup has the most pronounced damage in white matter integrity. Individually, SVM analysis of white matter FA provided highly accurate classification of MCI subtypes.
Resumo:
BACKGROUND: In contrast to wild type, interleukin-10-deficient (IL-10(-/-)) mice are able to clear Helicobacter infection. In this study, we investigated the immune response of IL-10(-/-) mice leading to the reduction of Helicobacter infection. MATERIALS AND METHODS: We characterized the immune responses of Helicobacter felis-infected IL-10(-/-) mice by studying the systemic antibody and cellular responses toward Helicobacter. We investigated the role of CD4(+) T cells in the Helicobacter clearance by injecting H. felis-infected IL-10(-/-) mice with anti-CD4 depleting antibodies. To examine the role of mast cells in Helicobacter clearance, we constructed and infected mast cells and IL-10 double-deficient mice. RESULTS: Reduction of Helicobacter infection in IL-10(-/-) mice is associated with strong humoral (fivefold higher serum antiurease antibody titers were measured in IL-10(-/-) in comparison to wild-type mice, p < .008) and cellular (urease-stimulated splenic CD4(+) T cells isolated from infected IL-10(-/-) mice produce 150-fold more interferon-gamma in comparison to wild-type counterparts, p < .008) immune responses directed toward Helicobacter. Depletion of CD4(+) cells from Helicobacter-infected IL-10(-/-) mice lead to the loss of bacterial clearance (rapid urease tests are threefold higher in CD4(+) depleted IL-10(-/-) in comparison to nondepleted IL-10(-/-) mice, p < .02). Mast cell IL-10(-/-) double-deficient mice clear H. felis infection, indicating that mast cells are unnecessary for the bacterial eradication in IL-10(-/-) mice. CONCLUSION: Taken together, these results suggest that CD4(+) cells are required for Helicobacter clearance in IL-10(-/-) mice. This reduction of Helicobacter infection is, however, not dependent on the mast cell population.
Resumo:
PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.
Resumo:
Audit of the Regulated Materials Facility Revenue Bond Funds of Iowa State University of Science and Technology (Iowa State University) as of and for the year ended June 30, 2007
Resumo:
PURPOSE: To suppress the noise, by sacrificing some of the signal homogeneity for numerical stability, in uniform T1 weighted (T1w) images obtained with the magnetization prepared 2 rapid gradient echoes sequence (MP2RAGE) and to compare the clinical utility of these robust T1w images against the uniform T1w images. MATERIALS AND METHODS: 8 healthy subjects (29.0±4.1 years; 6 Male), who provided written consent, underwent two scan sessions within a 24 hour period on a 7T head-only scanner. The uniform and robust T1w image volumes were calculated inline on the scanner. Two experienced radiologists qualitatively rated the images for: general image quality; 7T specific artefacts; and, local structure definition. Voxel-based and volume-based morphometry packages were used to compare the segmentation quality between the uniform and robust images. Statistical differences were evaluated by using a positive sided Wilcoxon rank test. RESULTS: The robust image suppresses background noise inside and outside the skull. The inhomogeneity introduced was ranked as mild. The robust image was significantly ranked higher than the uniform image for both observers (observer 1/2, p-value = 0.0006/0.0004). In particular, an improved delineation of the pituitary gland, cerebellar lobes was observed in the robust versus uniform T1w image. The reproducibility of the segmentation results between repeat scans improved (p-value = 0.0004) from an average volumetric difference across structures of ≈6.6% to ≈2.4% for the uniform image and robust T1w image respectively. CONCLUSIONS: The robust T1w image enables MP2RAGE to produce, clinically familiar T1w images, in addition to T1 maps, which can be readily used in uniform morphometry packages.
Resumo:
PURPOSE: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. MATERIALS AND METHODS: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. RESULTS: Under traction, the subacromial (Δ = 2.0 mm, P = 0.0003), superior (Δ = 0.7 mm, P = 0.0001) and inferior (Δ = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. CONCLUSION: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:1228-1233. © 2012 Wiley Periodicals, Inc.
Resumo:
Fibrin has been long used clinically for hemostasis and sealing, yet extension of use in other applications has been limited due to its relatively rapid resorption in vivo, even with addition of aprotinin or other protease inhibitors. We report an engineered aprotinin variant that can be immobilized within fibrin and thus provide extended longevity. When recombinantly fused to a transglutaminase substrate domain from α(2)-plasmin inhibitor (α(2)PI(1-8)), the resulting variant, aprotinin-α(2)PI(1-8), was covalently crosslinked into fibrin matrices during normal thrombin/factor XIIIa-mediated polymerization. Challenge with physiological plasmin concentrations revealed that aprotinin-α(2)PI(1-8)-containing matrices retained 78% of their mass after 3 wk, whereas matrices containing wild type (WT) aprotinin degraded completely within 1 wk. Plasmin challenge of commercial sealants Omrixil and Tisseel, supplemented with aprotinin-α(2)PI(1-8) or WT aprotinin, showed extended longevity as well. When seeded with human dermal fibroblasts, aprotinin-α(2)PI(1-8)-supplemented matrices supported cell growth for at least 33% longer than those containing WT aprotinin. Subcutaneously implanted matrices containing aprotinin-α(2)PI(1-8) were detectable in mice for more than twice as long as those containing WT aprotinin. We conclude that our engineered recombinant aprotinin variant can confer extended longevity to fibrin matrices more effectively than WT aprotinin in vitro and in vivo.