949 resultados para non-parametric technique


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Low back pain and its associated incapacitating effects constitute an important healthcare and socioeconomic problem, as well as being one of the main causes of disability among adults of working age. The prevalence of non-specific low back pain is very high among the general population, and 60-70% of adults are believed to have suffered this problem at some time. Nevertheless, few randomised clinical trials have been made of the efficacy and efficiency of acupuncture with respect to acute low back pain. The present study is intended to assess the efficacy of acupuncture for acute low back pain in terms of the improvement reported on the Roland Morris Questionnaire (RMQ) on low back pain incapacity, to estimate the specific and non-specific effects produced by the technique, and to carry out a cost-effectiveness analysis. METHODS/DESIGN Randomised four-branch controlled multicentre prospective study made to compare semi-standardised real acupuncture, sham acupuncture (acupuncture at non-specific points), placebo acupuncture and conventional treatment. The patients are blinded to the real, sham and placebo acupuncture treatments. Patients in the sample present symptoms of non specific acute low back pain, with a case history of 2 weeks or less, and will be selected from working-age patients, whether in paid employment or not, referred by General Practitioners from Primary Healthcare Clinics to the four clinics participating in this study. In order to assess the primary and secondary result measures, the patients will be requested to fill in a questionnaire before the randomisation and again at 3, 12 and 48 weeks after starting the treatment. The primary result measure will be the clinical relevant improvement (CRI) at 3 weeks after randomisation. We define CRI as a reduction of 35% or more in the RMQ results. DISCUSSION This study is intended to obtain further evidence on the effectiveness of acupuncture on acute low back pain and to isolate the specific and non-specific effects of the treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Indocyanine green video-angiography (ICG) is a recent examination technique, its possibilities and limitations as far as intraocular tumours are concerned, haven't been fully explored yet. MATERIAL AND METHODS: We have studied 50 cases of non-pigmented choroidal tumours, including 14 cases of choroidal hemangioma's, 11 cases of posterior uveal metastases and 25 cases of non-pigmented melanoma's. RESULTS: Characteristic images were obtained when examining choroidal hemangioma's and, until a certain point, posterior choroidal metastases. Non pigmented melanoma's on the contrary, presented a great variety of different indocyanine green angiographic pictures. CONCLUSION: Indocyanine green video-angiography (ICG) has a definite value in the differential diagnosis of non-pigmented posterior choroidal tumours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adenovirus-mediated gene therapy is hampered by severe virus-related toxicity, especially to the liver. The aim of the present study was to test the ability of a vascular exclusion technique to achieve transgene expression within selected liver segments, thus minimizing both viral and transgene product toxicity to the liver. An E1-E3-deleted replication-deficient adenovirus expressing a green fluorescent protein (GFP) reporter gene was injected into the portal vein of BDIX rats, with simultaneous clamping of the portal vein tributaries to liver segments II, III, IV, V, and VIII. GFP expression and inflammatory infiltrate were measured in the different segments of the liver and compared with those of the livers of animals receiving the viral vector in the portal vein without clamping. The GFP expression was significantly higher in the selectively perfused segments of the liver as compared with the non-perfused segments (p < 0.0001) and with the livers of animals that received the vector in the portal vein without clamping (p < 0.0001). Accordingly, the inflammatory infiltrate was more intense in the selectively perfused liver segments as compared with all other groups (p < 0.0001). Fluorescence was absent in lungs and kidneys and minimal in spleen. The clinical usefulness of adenovirus-mediated gene transfer to the liver largely depends on the reduction of its liver toxicity. Clamping of selected portal vein branches during injection allows for delivery of genes of interest to targeted liver segments. Transgene expression confined to selected liver segments may be useful in the treatment of focal liver diseases, including metastases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:To describe the indications, the surgical procedure and the clinical outcome of MLAM in the treatment of non traumatic corneal perforations and descemetoceles . Methods:A prospective, non comparative, interventional case series of eight consecutive patients (mean age 59 years old, 6 men and 2 women) with non traumatic corneal perforations or descemetoceles.The surgery consisted in a MLAM transplantation of a cryopreservated human amniotic membrane. The series included: three active herpetic keratitis, one rosacea, one perforation of an hydrops, one cicatricial pemphigoid, one perforation after an abcess in a corneal graft and one perforation after protonbeamtherapy. The clinical outcome included: the follow-up, the integrity of the eye, corneal epithelialization, inflammation and neovascularization, and the integration of the MLAM. Stromal thickness was followed precisely with the slit lamp. A corneal graft was performed at one patient after the MLAM, allowing microscopic investigation of the removed MLAM integrated in the cornea. Results:The mean follow-up was 8.78 months (range 3.57 to 30.17). Amniotic membrane transplantation was successful and reduced inflammation in 7 patients out of 8 ,after one procedure.One patient who presented a large herpetic keratitis epithelial defect with corneal anaesthesia had his MLAM dissolved after two weeks with an aqueous leakage. Epithelium healed within 3 weeks above 7 MLAM and remained stable at 3 months in 7 out of 8 patients. MLAM opacification gradually disappeared over a few months, however, stromal layers filling in the corneal perforations or above the descemetoceles remained stable. Conclusions:MLAM transplantation is a safe, effective and useful technique to cure non traumatic corneal perforations and descemetoceles. It can be performed in emergency despite the presence of an active inflammation or infection. By facilitating epithelialization, reducing inflammation and neovascularization, it allows corneal surface reconstruction in patients with persistent epithelial defects and corneal melting that usually ends in a perforation. For full visual rehabilitation, a delayed penetrating keratoplasty is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. METHODS: This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. RESULTS: During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. CONCLUSIONS: This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new parametric minimum distance time-domain estimator for ARFIMA processes is introduced in this paper. The proposed estimator minimizes the sum of squared correlations of residuals obtained after filtering a series through ARFIMA parameters. The estimator iseasy to compute and is consistent and asymptotically normally distributed for fractionallyintegrated (FI) processes with an integration order d strictly greater than -0.75. Therefore, it can be applied to both stationary and non-stationary processes. Deterministic components are also allowed in the DGP. Furthermore, as a by-product, the estimation procedure provides an immediate check on the adequacy of the specified model. This is so because the criterion function, when evaluated at the estimated values, coincides with the Box-Pierce goodness of fit statistic. Empirical applications and Monte-Carlo simulations supporting the analytical results and showing the good performance of the estimator in finite samples are also provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Weather radar observations are currently the most reliable method for remote sensing of precipitation. However, a number of factors affect the quality of radar observations and may limit seriously automated quantitative applications of radar precipitation estimates such as those required in Numerical Weather Prediction (NWP) data assimilation or in hydrological models. In this paper, a technique to correct two different problems typically present in radar data is presented and evaluated. The aspects dealt with are non-precipitating echoes - caused either by permanent ground clutter or by anomalous propagation of the radar beam (anaprop echoes) - and also topographical beam blockage. The correction technique is based in the computation of realistic beam propagation trajectories based upon recent radiosonde observations instead of assuming standard radio propagation conditions. The correction consists of three different steps: 1) calculation of a Dynamic Elevation Map which provides the minimum clutter-free antenna elevation for each pixel within the radar coverage; 2) correction for residual anaprop, checking the vertical reflectivity gradients within the radar volume; and 3) topographical beam blockage estimation and correction using a geometric optics approach. The technique is evaluated with four case studies in the region of the Po Valley (N Italy) using a C-band Doppler radar and a network of raingauges providing hourly precipitation measurements. The case studies cover different seasons, different radio propagation conditions and also stratiform and convective precipitation type events. After applying the proposed correction, a comparison of the radar precipitation estimates with raingauges indicates a general reduction in both the root mean squared error and the fractional error variance indicating the efficiency and robustness of the procedure. Moreover, the technique presented is not computationally expensive so it seems well suited to be implemented in an operational environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L' évaluation quantitative des dangers et des expositions aux nanomatériaux se heurte à de nombreuses incertitudes qui ne seront levées qu'à mesure de la progression des connaissances scientifiques de leurs propriétés. L' une des conséquences de ces incertitudes est que les valeurs limites d'exposition professionnelle définies actuellement pour les poussières ne sont pas nécessairement pertinentes aux nanomatériaux. En l'absence de référentiel quantitatif et, à la demande de la DGS pour éclairer les réflexions de l' AFNOR et de l'ISO sur le sujet, une démarche de gestion graduée des risques (control banding) a été élaborée au sein de l' Anses. Ce développement a été réalisé à l'aide d'un groupe d'experts rapporteurs rattaché au Comité d'experts spécialisés évaluation des risques liés aux agents physiques, aux nouvelles technologies et aux grands aménagements. La mise en oeuvre de la démarche de gestion graduée des risques proposée repose sur quatre grandes étapes: 1. Le recueil des informations. Cette étape consiste à réunir les informations disponibles sur les dangers du nanomatériau manufacturé considéré ; ainsi que sur l'exposition potentielle des personnes aux postes de travail (observation sur le terrain, mesures, etc.). 2. L'attribution d'une bande de danger. Le danger potentiel du nanomatériau manufacturé présent, qu'il soit brut où incorporé dans une matrice (liquide ou solide) est évalué dans cette étape. La bande danger attribuée tient compte de la dangerosité du produit bulk ou de sa substance analogue à l'échelle non-nanométrique, de la bio-persistance du matériau (pour les matériaux fibreux), de sa solubilité et de son éventuelle réactivité. 3. Attribution d'une bande d'exposition. La bande d'exposition du nanomatériau manufacturé considéré ou du produit en contenant est définie par le niveau de potentiel d'émission du produit. Elle tient compte de sa forme physique (solide, liquide, poudre aérosol), de sa pulvérulence et de sa volatilité. Le nombre de travailleurs, la fréquence, la durée d'exposition ainsi que la quantité mise en oeuvre ne sont pas pris en compte, contrairement à une évaluation classique des risques chimiques. 4. Obtention d'une bande de maîtrise des risques. Le croisement des bandes de dangers et d'exposition préalablement attribuées permet de défi nir le niveau de maîtrise du risque. Il fait correspondre les moyens techniques et organisationnels à mettre en oeuvre pour maintenir le risque au niveau le plus faible possible. Un plan d'action est ensuite défi ni pour garantir l'effi cacité de la prévention recommandée par le niveau de maîtrise déterminé. Il tient compte des mesures de prévention déjà existantes et les renforce si nécessaire. Si les mesures indiquées par le niveau de maîtrise de risque ne sont pas réalisables, par exemple, pour des raisons techniques ou budgétaires, une évaluation de risque approfondie devra être réalisée par un expert. La gestion graduée des risques est une méthode alternative pour réaliser une évaluation qualitative de risques et mettre en place des moyens de prévention sans recourir à une évaluation quantitative des risques. Son utilisation semble particulièrement adaptée au contexte des nanomatériaux manufacturés, pour lequel les choix de valeurs de référence (Valeurs limites d'exposition en milieu professionnel) et des techniques de mesurage appropriées souffrent d'une grande incertitude. La démarche proposée repose sur des critères simples, accessibles dans la littérature scientifi que ou via les données techniques relatives aux produits utilisés. Pour autant, sa mise en oeuvre requiert des compétences minimales dans les domaines de la prévention des risques chimiques (chimie, toxicologie, etc.), des nanosciences et des nanotechnologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our previously developed stochastic trajectory analysis technique has been applied to the calculation of first-passage time statistics of bound processes. Explicit results are obtained for linearly bound processes driven by dichotomous fluctuations having exponential and rectangular temporal distributions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stochastic-trajectory-analysis technique is applied to the calculation of the mean¿first-passage-time statistics for processes driven by external shot noise. Explicit analytical expressions are obtained for free and bound processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intracranial hypertension is an emergency suspected from clinical symptoms, imaging data and ophthalomologic signs. Intracranial hypertension is confirmed by invasive intracranial monitoring, which is the gold standard technique to measure intracranial pressure (ICP). Because of complications, hemorrhage or infection, non-invasive methods have been developed such as neuroimaging, transcranial Doppler sonography and optic nerve sheath diameter (ONSD) ultrasonography. We have reviewed ONSD technique that detects intracranial hypertension related volume variations of subarachnoid space along the retro bulbar segment of the optic nerve. Technique, indications and prospects are discussed.