922 resultados para methods and measurement


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Demand response has gain increasing importance in the context of competitive electricity markets environment. The use of demand resources is also advantageous in the context of smart grid operation. In addition to the need of new business models for integrating demand response, adequate methods are necessary for an accurate determination of the consumers’ performance evaluation after the participation in a demand response event. The present paper makes a comparison between some of the existing baseline methods related to the consumers’ performance evaluation, comparing the results obtained with these methods and also with a method proposed by the authors of the paper. A case study demonstrates the application of the referred methods to real consumption data belonging to a consumer connected to a distribution network.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Enterprise and Work Innovation Studies,6,IET, pp.9-51

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Workshop of COST Actions TU0601 and E55 September 21-22 2009, Ljubljana, Slovenia

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: Low-dose dobutamine stress echocardiography is a common and useful technique to assess myocardial viability in patients with ischemic cardiomyopathy. OBJECTIVE: To evaluate the use of low-dose dobutamine stress echocardiography in determining the functional status of patients with idiopathic dilated cardiomyopathy (IDCM). METHODS: Prospective study of 28 patients with IDCM by transthoracic echocardiography (2D), low-dose dobutamine stress echocardiography, cardiopulmonary exercise testing (CPET) and measurement of pro-BNP. RESULTS: The mean age of the population was 50.3 +/- 11.5 years, 9 female and 19 male. Mean ejection fraction was 32.1 +/- 9.8%. All were in sinus rhythm. The following parameters were analyzed in 2D echocardiography and after dobutamine: dimensions of left atrium (LA) and of left ventricle in diastole and systole, shortening fraction (%), left ventricular end-diastolic (EDV) and end-systolic volumes (ESV), ejection fraction (EF), and mitral inflow (E, A, E/A ratio and deceleration time). In CPET, we considered the following parameters: peak VO2 and % maximal peak VO2 attained. We compared echo results with CPET. There was a correlation between age and peak VO2 (r = -0.38 with p = 0.049). In 2D echo, there was a correlation between baseline EF and LA dimensions and peak VO2 (r = 0.45 / p = 0.004 and r = -0.49 / p = 0.014, respectively). After dobutamine echo, there was a correlation between some echo parameters and peak VO2: EF - r = 0.59 / p = 0.001, LA dimensions - r = 0.56 / p = 0.007, and ESV - r = -0.45 / p = 0.026. Percentage maximal peak VO2 attained correlated with LA dimensions measured in 2D echo and after dobutamine (r = -0.398 / p = 0.036 and r = -0.674 / p = 0.02 respectively) and EF after dobutamine (r = -0.389 / p = 0.04). The value of pro-BNP correlated with LA dimensions and baseline EF (r = 0.44 / p = 0.02 and r = -0.57 / p = 0.002, respectively), and the correlation was maintained after inotropic stimulation with dobutamine (r = 0.57 / p = 0.001 and r = -0.55 / p = 0.0039). CONCLUSION: Low-dose dobutamine stress echocardiography showed stronger correlations with cardiopulmonary exercise testing than the parameters evaluated by conventional echocardiography and could be used to determine the functional status of patients with dilated cardiomyopathy; patients with greater ejection fraction after inotropic stimulation had better cardiopulmonary tests.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Slowed atrial conduction may contribute to reentry circuits and vulnerability for atrial fibrillation (AF). The autonomic nervous system (ANS) has modulating effects on electrophysiological properties. However, complex interactions of the ANS with the arrhythmogenic substrate make it difficult to understand the mechanisms underlying induction and maintenance of AF. AIM: To determine the effect of acute ANS modulation in atrial activation times in patients (P) with paroxysmal AF (PAF). METHODS AND RESULTS: 16P (9 men; 59±14years) with PAF, who underwent electrophysiological study before AF ablation, and 15P (7 men; 58±11years) with atrioventricular nodal reentry tachycardia, without documentation or induction of AF (control group). Each group included 7P with arterial hypertension but without underlying structural heart disease. The study was performed while off drugs. Multipolar catheters were placed at the high right atrium (HRA), right atrial appendage (RAA), coronary sinus (CS) and His bundle area (His). At baseline and with HRA pacing (600ms, shortest propagated S2) we measured: i) intra-atrial conduction time (IACT, between RAA and atrial deflection in the distal His), ii) inter-atrial conduction time (interACT, between RAA and distal CS), iii) left atrial activation time (LAAT, between atrial deflection in the distal His and distal CS), iv) bipolar electrogram duration at four atrial sites (RAA, His, proximal and distal CS). In the PAF group, measurements were also determined during handgrip and carotid sinus massage (CSM), and after pharmacological blockade of the ANS (ANSB). AF was induced by HRA programmed stimulation in 56% (self-limited - 6; sustained - 3), 68.8% (self-limited - 6; sustained - 5), and 50% (self-limited - 5; sustained - 3) of the P, in basal, during ANS maneuvers, and after ANSB, respectively (p=NS). IACT, interACT and LAAT significantly lengthened during HRA pacing in both groups (600ms, S2). P with PAF have longer IACT (p<0.05), a higher increase in both IACT, interACT (p<0.01) and electrograms duration (p<0.05) with S2, and more fragmented activity, compared with the control group. Atrial conduction times and electrograms duration were not significantly changed during ANS stimulation. Nevertheless, ANS maneuvers increased heterogeneity of the local electrograms duration. Also, P with sustained AF showed longer interACT and LAAT during CSM. CONCLUSION: Atrial conduction times, electrograms duration and fractionated activity are increased in PAF, suggesting a role for conduction delays in the arrhythmogenic substrate. Acute vagal stimulation is associated with prolonged interACT and LAAT in P with inducible sustained AF and ANS modulation may influence the heterogeneity of atrial electrograms duration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In 1989, CONTI DÍAZ & RILLA published a hypothesis concerning the as yet unknown ecological niche of Paracoccidioides brasiliensis. The hypothesis proposed a highly efficient paracoccidioidal ecological strategy based on an important natural reservoir of the parasite, probably in heterothermic animals from fresh water environments. Further, the hypothesis proposed, a transient and variable residence in the soil with a wide aleuriospore dispersion throughout the environment together with an elevated capability of infecting humans, and domestic and wild animals. This paper analyzes scientific publications from the IX International Meeting on Paracoccidioidomycosis held in Águas de Lindoia, São Paulo, Brazil from 2-5 October 2005, providing a comparative study among this articles and with other recently published papers and the hypothesis' postulates. Since various findings and observations appear to agree with the postulates, the pursuit of novel, specific research projects in the supposed reservoirs is recommended partially or fully to confirm the hypothesis using classical laboratorial methods and modern molecular biology techniques.