999 resultados para maxillary premolars


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biomaterials such as membrane barriers and/or bone grafts are often used to enhance periapical new bone formation. A combination of apical surgery and these biomaterials is one of the latest treatment options for avoiding tooth extraction. In case of periapical lesions, guided tissue regeneration (GTR) is attempted to improve the self-regenerative healing process by excluding undesired proliferation of the gingival connective tissue or migration of the oral epithelial cells into osseous defects. In many cases, GTR is necessary for achieving periodontal tissue healing. This report describes the healing process after surgery in a challenging case with a long-term followup. In this case report, endodontic surgery was followed by retrograde sealing with mineral trioxide aggregate (MTA) in the maxillary right central incisor and left lateral incisor. Apicectomy was performed in the maxillary left central incisor and a 1-mm filling was removed. The bone defect was filled with an anorganic bone graft and covered with a decalcified cortical osseous membrane. No intraoperative or postoperative complications were observed. After 13 years of follow-up, the patient showed no clinical signs or symptoms associated with the lesion and radiographic examination showed progressive resolution of radiolucency. In conclusion, the combination of apical surgery and regenerative techniques can successfully help the treatment of periapical lesions of endodontic origin and is suitable for the management of challenging cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by highresolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated whether periodontal ligament (PL) thickness varied with root size and examined the possible influence of this variation on orthodontic mechanics. Measurements were taken of the maxillary left first molar in 54 male Wistar rats. Mean mesial and distal PL thicknesses were compared between the intermediate buccal and mesiobuccal roots using paired Student's t-tests with a 5% significance level. Mean values differed significantly between roots (p < 2.2 × 10-16). PL thickness in rats is directly proportional to root dimensions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To study the early sequential stages of osseointegration at implants installed in alveolar bony. Materials and methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Implants were installed, and the flaps were sutured to allow a fully submerged healing. The timing of the installations in the left side of the mandible and of sacrifices were performed with a schedule that various observation periods to sacrifice from 5, 10, 20, and 30 days were available so that n = 6 was obtained per each healing period. Ground sections were prepared and analyzed. Results: Newly formed bone in contact with the implant surface was found after 10 days of healing and the percentage increased up to 50% after 1 month of healing. A higher percentage was found in the trabecular compared with the cortical bony compartment. Old bone decreased by about 50% during healing, being still present after 1 month (16%). The proportions of bone debris and bone particles were at 27% after 5 days and decreased during healing to 6% after 1 month. Conclusion: Osseointegration (new bone-to-implant contact) developed at various rates for cortical and trabecular compartments, respectively. In the trabecular region, mesenchymal cells were identified, subsequently developing into new bone in contact with the implant surface. In the cortical compartment, however, resorptive processes were observed throughout all periods of healing. The proportion of newly formed bone percentage was lower compared with that of the trabecular area. Old bone was still present after 1 month of healing in both compartments. Bone debris and small bone particles appeared to be involved in initial bone formation. © 2013 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare immediate and staged approach implant placement in circumferential defects treated with deproteinized bovine bone mineral (DBBM); hidroxyapatite/tricalcium phosphate (HA/TP); autogenous bone (Ab); and coagulum (Cg); upon implant stability, osseointegration and alveolar crest maintenance. Materials and methods: Six dogs underwent extractions of lower premolars, bilaterally. Twelve weeks later four bone defects (6 mm wide/4 mm long) were drilled at one side and randomly filled with DBBM; HA/TP; Ab; and Cg, respectively, and left to heal (staged approach). Eight weeks later one implant (Osseospeed™, AstraTech) was placed in experimental sites. At the same session four defects were drilled on contra-lateral side and implants were inserted immediately after biomaterials grafting (immediate approach). Animals were euthanized 8 weeks later. Implant stability was measured by resonance frequency analysis (RFA) at installation and after sacrifice. Ground sections were prepared for bone contact (BIC); bone area (BA); distance implant shoulder-bone crest (IS-C); distance implant shoulder first bone contact (IS-B); and areas occupied by soft tissue. Results: The BA and BIC were superior in the staged approach. The Cg exhibited higher BIC and BA as compared with other materials at the total implant body (P = 0.004 and 0.012, respectively). The DBBM, HA/TP and Ab groups rendered similar BA and BIC. The immediate approach resulted in less crest resorption compared to staged approach. The biomaterials did not affect the IS-C and IS-B measurements. Particles area tended to be higher in DBBM group than HA/TP (P = 0.15), while soft tissue infiltrate was higher in DBBM group when used in the immediate approach (P = 0.04). The RFA indicated gain in stability in the staged approach (P = 0.002). The correlation test between RFA vs. BIC and BA demonstrated inferior stability for DBBM group in immediate approach (P = 0.01). Conclusions: Implants placed in healed defects resulted in better stability as a consequence of higher BIC and BA. The Cg alone rendered increased BIC compared to other materials in both approaches. Immediate approach should be preferable to staged approach in terms of alveolar crest maintenance. The BIC and BA values did not vary between micro and macro-threads in this experimental model. Implants installed in sites filled with DBBM in immediate approach were less stable. © 2011 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water. Materials and methods: Eighty four dental implants (3.3 × 10 mm) were divided into four groups (n = 21) according to implant macrogeometric design at the crestal region and crown fixation method: Microthreads Screwed (MS); Smooth Screwed (SS); Microthreads Cemented (MC), and Smooth Cemented (SC). The abutments were torqued to the implants and standardized maxillary central incisor metallic crowns were cemented (MC, SC) or screwed (MS, SS) and subjected to SSALT in water. The probability of failure versus cycles (90% two-sided confidence intervals) was calculated and plotted using a power law relationship for damage accumulation. Reliability for a mission of 50,000 cycles at 150 N (90% 2-sided confidence intervals) was calculated. Differences between final failure loads during fatigue for each group were assessed by Kruskal-Wallis along with Benferroni's post hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value (confidence interval range) derived from use level probability Weibull calculation of 1.30 (0.76-2.22), 1.17 (0.70-1.96), 1.12 (0.71-1.76), and 0.52 (0.30-0.89) for groups MC, SC, MS, and SS respectively, indicated that fatigue was an accelerating factor for all groups, except for SS. The calculated reliability was higher for SC (99%) compared to MC (87%). No difference was observed between screwed restorations (MS - 29%, SS - 43%). Failure involved abutment screw fracture for all groups. The cemented groups (MC, SC) presented more abutment and implant fractures. Significantly higher load to fracture values were observed for SC and MC relative to MS and SS (P < 0.001). Conclusion: Since reliability and strength to failure was higher for SC than for MC, our postulated null hypothesis was rejected. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). Materials and methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed™ TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. Conclusions: Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental tissues have special characteristics, and its regenerative capacity is noteworthy. However, understanding the circumstances that lead to regeneration is challenging. In this study, the chronology of the healing process after immediate replantation of rat incisor teeth was examined by histological and immunohistochemical analyses within a 60-day period. Thirty-six male Wistar rats had their maxillary right incisors extracted and replanted after 15min in saline storage. The rats were sacrificed immediately 3, 7, 15, 28, and 60days after replantation. The histological analysis showed rupture of the periodontal ligament and formation of a blood clot, which started being replaced by a connective tissue after 3days. At 7days, the gingival mucosa epithelium was reinserted and areas of root resorption could be seen. At 15days, the periodontal ligament was repaired. At 3days, the pulp presented an absence of the odontoblast layer, which started being replaced by a connective tissue. This tissue suffered gradual calcification, filling the root canal at 28 and 60days. The root ends were closed. The immunohistochemical analysis revealed greater expression of OP, OPG, and RANK proteins in the initial periods (0 and 3days), while TRAP expression predominated at 28 and 60days (P<0.05). In conclusion, in delayed tooth replantation, there is great new bone formation activity in the earlier periods of the repair process, while a predominance of bone resorption and remodeling is observed in the more advanced periods. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When late replantation is performed, the root surface and root canal should be treated. Notwithstanding failures still occur, because of the high rates of root resorption, evidencing the need to search for substances that may inhibit root resorption. The acetazolamide is a known anti-resorptive agent, and its use as root canal dressing may increase the success rates in the treatment of root resorption. Therefore, this study evaluated the effect of an acetazolamide paste used as root canal dressing in late replanted teeth. The study was conducted on 24 maxillary right incisors of rats, which were avulsed and divided in two groups. In group I, the teeth were kept dry for 30min, had their root surfaces rubbed with a blade, and were treated with 2% sodium fluoride at pH 5.5 for 20min; the root canals were instrumented and filled with acetazolamide paste; and then the teeth were replanted. In group II, the treatment was similar to group I, except for the root canal dressing, with utilization of calcium hydroxide in group II. At 15 and 60days after replantation, the animals were killed and the specimens were processed in a histotechnical laboratory for microscopic and morphometric analysis. The results demonstrated the ability of both intracanal substances to limit root resorption, yet they were unable to completely inhibit the root resorption. Replacement resorption lacunae were present in greater proportion in group II, at 60days. It was concluded that the acetazolamide paste was effective to limit the root resorption, being more effective in limiting the replacement resorption compared with calcium hydroxide. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been demonstrated that histamine interferes with the recruitment, formation and activity of osteoclasts via H1- and H2-receptors. Cimetidine is a H2-receptor antagonist used for treatment of gastric ulcers that seems to prevent bone resorption. In this study, a possible cimetidine interference was investigated in the number of alveolar bone osteoclasts. The incidence of osteoclast apoptosis and immunoexpression of RANKL (receptor activator of nuclear factor κB ligand) was also evaluated. Adult male rats were treated with 100mg kg-1 of cimetidine for 50days (CimG); the sham group (SG) received saline. Maxillary fragments containing the first molars and alveolar bone were fixed, decalcified and embedded in paraffin. The sections were stained by H&E or submitted to tartrate-resistant acid phosphatase (TRAP) method. TUNEL (terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling) method and immunohistochemical reactions for detecting caspase-3 and RANKL were performed. The number of TRAP-positive osteoclasts, the frequency of apoptotic osteoclasts and the numerical density of RANKL-positive cells were obtained. Osteoclast death by apoptosis was confirmed by transmission electron microscopy (TEM). In CimG, TRAP-positive osteoclasts with TUNEL-positive nuclei and caspase-3-immunolabeled osteoclasts were found. A significant reduction in the number of TRAP-positive osteoclasts and a high frequency of apoptotic osteoclasts were observed in CimG. Under TEM, detached osteoclasts from the bone surface showed typical features of apoptosis. Moreover, a significant reduction in the numerical density of RANKL-positive cells was observed in CimG. The significant reduction in the number of osteoclasts may be due to cimetidine-induced osteoclast apoptosis. However, RANKL immunoexpression reduction also suggests a possible interference of cimetidine treatment in the osteoclastogenesis. © 2012 The Authors Journal of Anatomy © 2012 Anatomical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the presence or absence of adjacent teeth on the level of the mesial and distal alveolar bony crest following healing at sites where implants were installed immediately into extraction sockets. Material and methods: Six Labrador dogs were used. In the right side of the mandible, full-thickness flaps were elevated, and the second, third, and fourth premolars and first molars were extracted. In the left side of the mandible, endodontic treatments of the mesial roots of the third and fourth premolars as well as of the first molars were performed. Full-thickness flaps were elevated, the teeth were hemi-sected, and the distal roots were removed. The second premolars were extracted as well. Subsequently, implants were bilaterally installed with the implant shoulder flush with the buccal bony crest. Implants were placed in the center of the alveoli, but at the fourth premolars, they were placed toward the lingual bony plate of the alveoli. After 3 months of healing, the animals were euthanized and histological sections of the sites prepared. Results: Larger bony crest resorption was observed at the test compared with the control sites, both at the bucco-lingual and mesio-distal aspects. The differences between test and controls for the coronal level of osseointegration were smaller than those for resorption. When data from all mesial and distal sites facing an adjacent tooth were collapsed and compared with those opposing an edentulous zone, lower bony crest resorption and deeper residual marginal defects were found at the sites with neighboring teeth. Conclusion: The extraction of teeth adjacent to a socket into which implants were installed immediately after tooth extraction caused more alveolar bone resorption both for the bucco-lingual and at the mesio-distal aspects compared with sites adjacent to a maintained tooth. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of implant positioning into extraction sockets on bone formation at buccal alveolar dehiscence defects. Material and Methods: In six Labrador dogs the pulp tissue of the mesial roots of 4P4 was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemi-sectioned and the distal roots removed. The implants were placed in contact with either the buccal (test site) or with the lingual (control site) bony wall of the extraction sockets. Healing abutments were affixed and triangular buccal bony dehiscence defects, about 2.7 mm deep and 3.5 mm wide, were then prepared. No regenerative procedures were done and a non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment. Results: After 4 months of healing, the bony crest and the coronal border of osseointegration at the test sites were located 1.71 ± 1.20 and 2.50 ± 1.21 mm apically to the implant shoulder, respectively. At the control sites, the corresponding values were 0.68 ± 0.63 and 1.69 ± 0.99 mm, respectively. The differences between test and control reached statistical significance (P < 0.05). Residual marginal bone defects were found both at the test and control sites. A statistically significant difference between test and control sites was only found at the lingual aspects (depth 2.09 ± 1.01 and 1.01 ± 0.48 mm, respectively). Similar heights of the buccal biological width were observed at both sites (about 5.1 mm). Conclusions: The placement of implants in a lingual position of the extraction sockets allowed a higher degree of bone formation at buccal alveolar dehiscence defects compared with a buccal positioning. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interpretation of the set of radiographs taken during the follow-up period after tooth replantation might pose several difficulties, especially the inability to adequately reproduce the projection geometry of the exposures. This article describes a method for the geometric standardization of intraoral radiographs using a custom-made apparatus comprising a film-holder attached to an occlusal splint for the long-term follow up of dentoalveolar trauma. The method was applied in a patient who suffered an avulsion of the maxillary central incisors and had the teeth replanted after 4 h in saline storage. Endodontic treatment started 7 days after the trauma with changes of a calcium hydroxide intracanal medication every 15 days in the first 2 months and thereafter at 30-day intervals for 8 months. Root canal filling was carried out after this period. The radiographic exposures taken at the follow-up visits were standardized to identify the possible alterations during the repair process, such as root resorptions. A maxillary arch impression was made with alginate, and the model was cast in stone for fabrication of an acetate occlusal splint. The custom-made apparatus used for standardization of the radiographic exposures was fabricated by fixing a Rinn X-C-P film-holder and a 5-mm-long piece of 0.7-mm orthodontic wire to the occlusal splint with autopolymerized acrylic resin. Radiographs were taken at 4-month intervals, starting 10 months after replantation up to 76 months. The images were digitized and analysed using the Digora system. The length of the central incisors was determined to verify the reproduction of the projection geometry of the exposures and the orthodontic wire served to assess accuracy during length estimations in the radiographs. The method described in this article for geometric standardization of intraoral radiographs provided a consistent reproduction of the geometric exposure parameters, being indicated for use in the radiographic follow up of cases of dentoalveolar trauma. © 2012 John Wiley & Sons A/S.