959 resultados para leakage


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the oil prospection research seismic data are usually irregular and sparsely sampled along the spatial coordinates due to obstacles in placement of geophones. Fourier methods provide a way to make the regularization of seismic data which are efficient if the input data is sampled on a regular grid. However, when these methods are applied to a set of irregularly sampled data, the orthogonality among the Fourier components is broken and the energy of a Fourier component may "leak" to other components, a phenomenon called "spectral leakage". The objective of this research is to study the spectral representation of irregularly sampled data method. In particular, it will be presented the basic structure of representation of the NDFT (nonuniform discrete Fourier transform), study their properties and demonstrate its potential in the processing of the seismic signal. In this way we study the FFT (fast Fourier transform) and the NFFT (nonuniform fast Fourier transform) which rapidly calculate the DFT (discrete Fourier transform) and NDFT. We compare the recovery of the signal using the FFT, DFT and NFFT. We approach the interpolation of seismic trace using the ALFT (antileakage Fourier transform) to overcome the problem of spectral leakage caused by uneven sampling. Applications to synthetic and real data showed that ALFT method works well on complex geology seismic data and suffers little with irregular spatial sampling of the data and edge effects, in addition it is robust and stable with noisy data. However, it is not as efficient as the FFT and its reconstruction is not as good in the case of irregular filling with large holes in the acquisition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research seeks to understand how the problem of information security is treated in Brazil by the public thematization and also how it can affect the political and economic aspects of both Brazilian companies and government by using a study case based on the document leak event of the National Security Agency by Snowden. For this, the study case of sites, blogs and news portal coverage was carried out from the perspective of evidential paradigm, studies of movement and event concept. We are interested in examining how the media handles the information security topic and what its impact on national and international political relations. The subject matter was considered the largest data leakage in history of the NSA, which ranks as the world's largest agency of expression intelligence. This leak caused great repercussions in Brazil since it was revealed that the country was the most watched by the United States of America, behind only USA itself. The consequences were: a big tension between Brazil and the US and a public discussion about privacy and freedom on Internet. The research analyzed 256 publications released by Brazilian media outlets in digital media, in the period between June and July 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research seeks to understand how the problem of information security is treated in Brazil by the public thematization and also how it can affect the political and economic aspects of both Brazilian companies and government by using a study case based on the document leak event of the National Security Agency by Snowden. For this, the study case of sites, blogs and news portal coverage was carried out from the perspective of evidential paradigm, studies of movement and event concept. We are interested in examining how the media handles the information security topic and what its impact on national and international political relations. The subject matter was considered the largest data leakage in history of the NSA, which ranks as the world's largest agency of expression intelligence. This leak caused great repercussions in Brazil since it was revealed that the country was the most watched by the United States of America, behind only USA itself. The consequences were: a big tension between Brazil and the US and a public discussion about privacy and freedom on Internet. The research analyzed 256 publications released by Brazilian media outlets in digital media, in the period between June and July 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The direct drive point absorber is a robust and efficient system for wave energy harvesting, where the linear generator represents the most complex part of the system. Therefore, its design and optimization are crucial tasks. The tubular shape of a linear generator’s magnetic circuit offers better permanent magnet flux encapsulation and reduction in radial forces on the translator due to its symmetry. A double stator topology can improve the power density of the linear tubular machine. Common designs employ a set of aligned stators on each side of a translator with radially magnetized permanent magnets. Such designs require doubling the amount of permanent magnet material and lead to an increase in the cogging force. The design presented in this thesis utilizes a translator with buried axially magnetized magnets and axially shifted positioning of the two stators such that no additional magnetic material, compared to single side machine, is required. In addition to the conservation of magnetic material, a significant improvement in the cogging force occurs in the two phase topology, while the double sided three phase system produces more power at the cost of a small increase in the cogging force. The analytical and the FEM models of the generator are described and their results compared to the experimental results. In general, the experimental results compare favourably with theoretical predictions. However, the experimentally observed permanent magnet flux leakage in the double sided machine is larger than predicted theoretically, which can be justified by the limitations in the prototype fabrication and resulting deviations from the theoretical analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis investigated the risk of accidental release of hydrocarbons during transportation and storage. Transportation of hydrocarbons from an offshore platform to processing units through subsea pipelines involves risk of release due to pipeline leakage resulting from corrosion, plastic deformation caused by seabed shakedown or damaged by contact with drifting iceberg. The environmental impacts of hydrocarbon dispersion can be severe. Overall safety and economic concerns of pipeline leakage at subsea environment are immense. A large leak can be detected by employing conventional technology such as, radar, intelligent pigging or chemical tracer but in a remote location like subsea or arctic, a small chronic leak may be undetected for a period of time. In case of storage, an accidental release of hydrocarbon from the storage tank could lead pool fire; further it could escalate to domino effects. This chain of accidents may lead to extremely severe consequences. Analyzing past accident scenarios it is observed that more than half of the industrial domino accidents involved fire as a primary event, and some other factors for instance, wind speed and direction, fuel type and engulfment of the compound. In this thesis, a computational fluid dynamics (CFD) approach is taken to model the subsea pipeline leak and the pool fire from a storage tank. A commercial software package ANSYS FLUENT Workbench 15 is used to model the subsea pipeline leakage. The CFD simulation results of four different types of fluids showed that the static pressure and pressure gradient along the axial length of the pipeline have a sharp signature variation near the leak orifice at steady state condition. Transient simulation is performed to obtain the acoustic signature of the pipe near leak orifice. The power spectral density (PSD) of acoustic signal is strong near the leak orifice and it dissipates as the distance and orientation from the leak orifice increase. The high-pressure fluid flow generates more noise than the low-pressure fluid flow. In order to model the pool fire from the storage tank, ANSYS CFX Workbench 14 is used. The CFD results show that the wind speed has significant contribution on the behavior of pool fire and its domino effects. The radiation contours are also obtained from CFD post processing, which can be applied for risk analysis. The outcome of this study will be helpful for better understanding of the domino effects of pool fire in complex geometrical settings of process industries. The attempt to reduce and prevent risks is discussed based on the results obtained from the numerical simulations of the numerical models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent evidence suggests that the Subtropical Convergence (STC) zone east of New Zealand shifted little from its modern position along Chatham Rise during the last glaciation, and that offshore surface waters north of the STC zone cooled only slightly. However, at nearshore core site P69 (2195 m depth), 115 km off the east coast of North Island and ca 300 km north of the modern STC zone, planktonic foraminiferal species, transfer function data and stable oxygen and carbon isotope records suggest that surface waters were colder by up to 6°C during the late last glacial period compared to the Holocene, and included a strong upwelling signature. Presently site P69 is bathed by south-flowing subtropical waters in the East Cape Current. The nearshore western end of Chatham Rise supports a major bathymetric depression, the Mernoo Saddle, through which some exchange between northern subtropical and southern subantarctic water presently occurs. It is proposed that as a result of much intensified current flows south of the Rise during the last glaciation, a consequence of more compressed subantarctic water masses, lowered sea level, and an expanded and stronger Westerly Wind system, there was accelerated leakage northwards of both Australasian Subantarctic Water and upwelled Antarctic Intermediate Water over Mernoo Saddle in a modified and intensified Southland Current. The expanded cold water masses displaced the south-flowing warm East Cape Current off southeastern North Island, and offshore divergence was accompanied by wind-assisted upwelling of nutrient-rich waters in the vicinity of P69. A comparable kind of inshore cold water jetting possibly characterised most glacial periods since the latest Miocene, and may account for the occasional occurrence of subantarctic marine fossils in onland late Cenozoic deposits north of the STC zone, rather than invoking wholesale major oscillations of the oceanic STC itself.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Models indicate that a complete shutdown of deep and intermediate water production is a possible consequence of extreme climate conditions in the northern North Atlantic, and the high ratio of 231Pa to 230Th on Bermuda Rise is evidence that this might have happened ?17 ka during Heinrich event 1 (H1). However, new radiocarbon data from bivalves that lived at ?4.6 km on the Bermuda Rise during H1 lead to a different conclusion. The bivalve data do indeed indicate ventilation of the deep western North Atlantic was suppressed during H1 but not as much as it was during the last glacial maximum. We propose that high diatom flux to the Bermuda Rise during H1 is at least in part responsible for increased 231Pa/230Th at that time. Although we cannot say for sure why opal production was so high in a gyre center location at that time, increased leakage of silica rich waters from the Southern Ocean to the North Atlantic is one possibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates the determinants of international R&D outsourcing, in particular the role of trade. We construct a monopolistic competition model with heterogeneous firms where outsourcing increases a firm’s fixed transaction as well as its productivity. Financial constraints affect the decision to outsource R&D more to non-exporters than to exporters. In contrast, exporters are more sensitive to a lack of information because they have higher losses when there is technology leakage. We test these predictions using a panel database of Spanish companies. The results highlight the relevance of information in competitive markets, and the role of trade to induce companies to engage in other globalization strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermal stability of AlGaN/GaN MOS-HEMTs and -diodes using Gd_(2)O_(3) are investigated by means of different thermal cycles and storage tests up to 500ºC for one week. IV DC and pulsed characteristics of the devices before and after the processes are evaluated and compared with conventional HEMTs. Results show that the devices with Gd_(2)O_(3) dielectric layer have lower leakage current and a more stable behavior during thermal treatment processes compared with conventional devices. In fact, an excellent on/off ratio of about 108 and a stable V_(t) is observed after storage at high temperature. The beneficial effects of Gd_(2)O_(3) on trapping effects of MOS-HEMTs are also dis-cussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims The purpose of this study was to examine the effect of a pelvic floor muscle (PFM) rehabilitation program on incontinence symptoms, PFM function, and morphology in older women with SUI. Methods Women 60 years old and older with at least weekly episodes of SUI were recruited. Participants were evaluated before and after a 12-week group PFM rehabilitation intervention. The evaluations included 3-day bladder diaries, symptom, and quality of life questionnaires, PFM function testing with dynamometry (force) and electromyography (activation) during seven tasks: rest, PFM maximum voluntary contraction (MVC), straining, rapid-repeated PFM contractions, a 60 sec sustained PFM contraction, a single cough and three repeated coughs, and sagittal MRI recorded at rest, during PFM MVCs and during straining to assess PFM morphology. Results Seventeen women (68.9 ± 5.5 years) participated. Following the intervention the frequency of urine leakage decreased and disease-specific quality of life improved significantly. PFM function improved significantly: the participants were able to perform more rapid-repeated PFM contractions; they activated their PFMs sooner when coughing and they were better able to maintain a PFM contraction between repeated coughs. Pelvic organ support improved significantly: the anorectal angle was decreased and the urethrovescial junction was higher at rest, during contraction and while straining. Conclusions This study indicated that improvements in urine leakage were produced along with improvements in PFM co-ordination (demonstrated by the increased number of rapid PFM contractions and the earlier PFM activation when coughing), motor-control, pelvic organ support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Motivated patients are more likely to adhere to treatment resulting in better outcomes. Virtual reality rehabilitation (VRR) is a treatment approach that includes video gaming to enhance motivation and functional training. Aims The study objectives were (1) to evaluate the feasibility of using a combination of pelvic floor muscles (PFM) exercises and VRR (PFM/VRR) to treat mixed urinary incontinence (MUI) in older women, (2) to evaluate the effectiveness of the PFM/VRR program on MUI symptoms, quality of life (QoL), and (3) gather quantitative information regarding patient satisfaction with this new combined training program. Methods Women 65 years and older with at least 2 weekly episodes of MUI were recruited. Participants were evaluated two times before and one time after a 12-week PFM/VRR training program. Feasibility was defined as the participants' rate of participation in and completion of both the PFM/VRR training program and the home exercise. Effectiveness was evaluated through a bladder diary, pad test, symptom and QoL questionnaire, and participant's satisfaction through a questionnaire. Results Twenty-four women (70.5 ± 3.6 years) participated. The participants complied with the study demands in terms of attendance at the weekly treatment sessions (91%), adherence to home exercise (92%) and completion of the three evaluations (96%). Post-intervention, the frequency and quantity of urine leakage decreased and patientreported symptoms and QoL improved significantly. Most participants were very satisfied with treatment (91%). Conclusion A combined PFM/VRR program is an acceptable, efficient, and satisfying functional treatment for older women with MUI and should be explore through further RCTs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technological developments in biomedical microsystems are opening up new opportunities to improve healthcare procedures. Swallowable diagnostic sensing capsules are an example of these. In none of the diagnostic sensing capsules, is the sensor’s first level packaging achieved via Flip Chip Over Hole (FCOH) method using Anisotropic Conductive Adhesive (ACA). In a capsule application with direct access sensor (DAS), ACA not only provides the electrical interconnection but simultaneously seals the interconnect area and the underlying electronics. The development showed that the ACA FCOH was a viable option for the DAS interconnection. Adequate adhesive formed a strong joint that withstood a shear stress of 120N/mm2 and a compressive stress of 6N required to secure the final sensor assembly in place before encapsulation. Electrical characterization of the ACA joint in a fluid environment showed that the ACA was saturated with moisture and that the ions in the solution actively contributed to the leakage current, characterized by the varying rate of change of conductance. Long term hygrothermal aging of the ACA joint showed that a thermal strain of 0.004 and a hygroscopic strain of 0.0052 were present and resulted in a fatigue like process. In-vitro tests showed that high temperature and acidity had a deleterious effect of the ACA and its joint. It also showed that the ACA contact joints positioned at around or over 1mm would survive the gastrointestinal (GI) fluids and would be able to provide a reliable contact during the entire 72hr of the GI transit time. A final capsule demonstrator was achieved by successfully integrating the DAS, the battery and the final foldable circuitry into a glycerine capsule. Final capsule soak tests suggested that the silicone encapsulated system could survive the 72hr gut transition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis investigates the emerging InAlN high electron mobility transistor (HEMT) technology with respect to its application in the space industry. The manufacturing processes and device performance of InAlN HEMTs were compared to AlGaN HEMTs, also produced as part of this work. RF gain up to 4 GHz was demonstrated in both InAlN and AlGaN HEMTs with gate lengths of 1 μm, with InAlN HEMTs generally showing higher channel currents (~150 c.f. 60 mA/mm) but also degraded leakage properties (~ 1 x 10-4 c.f. < 1 x 10-8 A/mm) with respect to AlGaN. An analysis of device reliability was undertaken using thermal stability, radiation hardness and off-state breakdown measurements. Both InAlN and AlGaN HEMTs showed excellent stability under space-like conditions, with electrical operation maintained after exposure to 9.2 Mrad of gamma radiation at a dose rate of 6.6 krad/hour over two months and after storage at 250°C for four weeks. Furthermore a link was established between the optimisation of device performance (RF gain, power handling capabilities and leakage properties) and reliability (radiation hardness, thermal stability and breakdown properties), particularly with respect to surface passivation. Following analysis of performance and reliability data, the InAlN HEMT device fabrication process was optimised by adjusting the metal Ohmic contact formation process (specifically metal stack thicknesses and anneal conditions) and surface passivation techniques (plasma power during dielectric layer deposition), based on an existing AlGaN HEMT process. This resulted in both a reduction of the contact resistivity to around 1 x 10-4 Ω.cm2 and the suppression of degrading trap-related effects, bringing the measured gate-lag close to zero. These discoveries fostered a greater understanding of the physical mechanisms involved in device operation and manufacture, which is elaborated upon in the final chapter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Germanium was of great interest in the 1950’s when it was used for the first transistor device. However, due to the water soluble and unstable oxide it was surpassed by silicon. Today, as device dimensions are shrinking the silicon oxide is no longer suitable due to gate leakage and other low-κ dielectrics such as Al2O3 and HfO2 are being used. Germanium (Ge) is a promising material to replace or integrate with silicon (Si) to continue the trend of Moore’s law. Germanium has better intrinsic mobilities than silicon and is also silicon fab compatible so it would be an ideal material choice to integrate into silicon-based technologies. The progression towards nanoelectronics requires a lot of in depth studies. Dynamic TEM studies allow observations of reactions to allow a better understanding of mechanisms and how an external stimulus may affect a material/structure. This thesis details in situ TEM experiments to investigate some essential processes for germanium nanowire (NW) integration into nanoelectronic devices; i.e. doping and Ohmic contact formation. Chapter 1 reviews recent advances in dynamic TEM studies on semiconductor (namely silicon and germanium) nanostructures. The areas included are nanowire/crystal growth, germanide/silicide formation, irradiation, electrical biasing, batteries and strain. Chapter 2 details the study of ion irradiation and the damage incurred in germanium nanowires. An experimental set-up is described to allow for concurrent observation in the TEM of a nanowire following sequential ion implantation steps. Grown nanowires were deposited on a FIB labelled SiN membrane grid which facilitated HRTEM imaging and facile navigation to a specific nanowire. Cross sections of irradiated nanowires were also performed to evaluate the damage across the nanowire diameter. Experiments were conducted at 30 kV and 5 kV ion energies to study the effect of beam energy on nanowires of varied diameters. The results on nanowires were also compared to the damage profile in bulk germanium with both 30 kV and 5 kV ion beam energies. Chapter 3 extends the work from chapter 2 whereby nanowires are annealed post ion irradiation. In situ thermal annealing experiments were conducted to observe the recrystallization of the nanowires. A method to promote solid phase epitaxial growth is investigated by irradiating only small areas of a nanowire to maintain a seed from which the epitaxial growth can initiate. It was also found that strain in the nanowire greatly effects defect formation and random nucleation and growth. To obtain full recovery of the crystal structure of a nanowire, a stable support which reduces strain in the nanowire is essential as well as containing a seed from which solid phase epitaxial growth can initiate. Chapter 4 details the study of nickel germanide formation in germanium nanostructures. Rows of EBL (electron beam lithography) defined Ni-capped germanium nanopillars were extracted in FIB cross sections and annealed in situ to observe the germanide formation. Chapter 5 summarizes the key conclusions of each chapter and discusses an outlook on the future of germanium nanowire studies to facilitate their future incorporation into nanodevices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims The purpose of this study was to examine the effect of a pelvic floor muscle (PFM) rehabilitation program on incontinence symptoms, PFM function, and morphology in older women with SUI. Methods Women 60 years old and older with at least weekly episodes of SUI were recruited. Participants were evaluated before and after a 12-week group PFM rehabilitation intervention. The evaluations included 3-day bladder diaries, symptom, and quality of life questionnaires, PFM function testing with dynamometry (force) and electromyography (activation) during seven tasks: rest, PFM maximum voluntary contraction (MVC), straining, rapid-repeated PFM contractions, a 60 sec sustained PFM contraction, a single cough and three repeated coughs, and sagittal MRI recorded at rest, during PFM MVCs and during straining to assess PFM morphology. Results Seventeen women (68.9 ± 5.5 years) participated. Following the intervention the frequency of urine leakage decreased and disease-specific quality of life improved significantly. PFM function improved significantly: the participants were able to perform more rapid-repeated PFM contractions; they activated their PFMs sooner when coughing and they were better able to maintain a PFM contraction between repeated coughs. Pelvic organ support improved significantly: the anorectal angle was decreased and the urethrovescial junction was higher at rest, during contraction and while straining. Conclusions This study indicated that improvements in urine leakage were produced along with improvements in PFM co-ordination (demonstrated by the increased number of rapid PFM contractions and the earlier PFM activation when coughing), motor-control, pelvic organ support.