944 resultados para intercondylar notch stenosis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of thermochemical treatment namely carburising on the fatigue behaviour of one carbon and two alloy steels has been studied in rotating and unidirectional bending. The effect of carbon profile on the unidirect¬ional bending fatigue strength of 63SA14 was assessed, and it was found that single stage carburising with a surface carbon content of 0.8% has resulted in a higher fatigue strength than other types of carbon profiles. Residual stresses and other metallurgical variables arising from different carbon profiles, were also considered. The highest compressive stresses h~e resulted from boost-diffuse-carburising. On the other hand surface decarburisation was associated with tensile residual stresses and a reduced fatigue strength. Retained austenite was found to be detrimental in unidirectional bending fatigue; however its presence in carburised 83SAIS did not seem to influence the rotating bending fatigue strength. Carbide particles in globular and/or intergranular form were detrimental to compressive residual stresses; the unidirectional bending fatigue strength is markedly lowered. The highest fatigue strength was accomplished by vacuum carburising. The absence of internal oxidation was the key factor in the increased fatigue strength; the presence of uniformly distributed fine carbide particles did not upset the superior fatigue strength of vacuum carburised pieces. The effect of mean stress on the fatigue strength of carburised 63SA14 was studied. Increasing the mean stress as would be expected resulted in a decreased fatigue strength. Carburisation showed its advantages at low mean stress, but at high mean stress it offers little advantage over the uncarburised hardened conditions. Notch effect was also studied in unidirectional bending of carburised 080MlS. The general trend showed that the fatigue strength decreases with increasing the stress concentration factor. But different carburising conditions have different effect on notch sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electroretinogram evoked by reversal pattern stimulation (rPERG) is known to contain both pattern contrast and luminance related components. The retinal mechanisms of the transient rPERGs subserving these functional characteristics are the main concern in the present studies. Considerable attention has been paid to the luminance-related characteristics of the response. The transient PERGs were found to consist of two subsequent processes using low frequency attenuation analysis. The processes overlapped and the individual difference in each process timings formed the major cause for the variations of the negative potential waveform of the transient rPERGs. Attention has been paid to those having ‘notch’ type of variation. Under different contrast levels, the amplitudes of the positive and negative potentials were linearly increased with higher contrast level and the negative potential showed a higher sensitivity to contrast changes and higher contrast gain. Under lower contrast levels, the decreased amplitudes made the difference in the timing course of the positive and negative processes evident, interpreting the appearance of the notch in some cases. Visual adaptation conditions for recording the transient rPERG were discussed. Another effort was to study the large variation of the transient rPERGs (especially the positive potential, P50) in the elderly who’s distant and near visual acuity were normal. It was found that reduction of retinal illumination contributed mostly to the P50 amplitude loss and contrast loss mostly to the negative potential (N95) amplitude loss. Senile miosis was thought to have little effect on the reduction of the retinal illumination, while the changes in the optics of the eye was probably the major cause for it, which interpreted the larger individual variation of the P50 amplitude of the elderly PERGs. Convex defocus affected the transient rPERGs more effectively than concave lenses, especially the N95 amplitude in the elderly. The disability of accommodation and the type and the degree of subjects’ ametropia should be taken into consideration when the elderly rPERGs were analysed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulsating; tension fatigue tests have been carried out on edge notched specimens of a mild steel. An electrical potential drop technique was used to determine the number of cycles taken to initiate cracks and the rate at which the cracks grew across the specimen. The results could be described by the range of stress intensity factor, which for crack initiation was modified to take account of the notch root radius. Analysis of elastic stress distributions at cracks and notches and models of plasticity at crack tips are used to discuss the results. Limited evidence in the literature indicates that the fracture mechanics approach may provide a general description of crack initiation and growth in notched specimens, and a simple graphical method of calculating fatigue lives is described. The results are used to illustrate the effects of specimen size and geometry on the fatigue life of notched specimens. The relevance of the work to the assessment of the significance of defects in welds is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tensile, crack opening displacement (COD), blunt notch, and Charpy impact tests were used to investigate cleavage initiation in the intercritically reheated coarse-grained heat-affected zone (IC CG HAZ) of three steels. The steels were chosen to provide different distributions and morphologies of MA (high-carbon martensite with some retained austenite) particles within the IC CG HAZ structure. Observation of minimum impact toughness values for the IC CG HAZ was found to be associated with a particular microstructure containing a near-connected grain boundary network of blocky MA particles, the MA particles being significantly harder than the internal grain microstructure. The initiation mechanism for this structure was determined to be from a combination of an overlap of residual transformational induced stress fields, due to the formation of the MA particles, between two closely spaced particles and stress concentration effects resulting from debonding of the particles. © 1994 The Minerals, Metals and Materials Society, and ASM International.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In part 1 of this article, cleavage initiation in the intercritically reheated coarse-grained heat affected zone (IC CG HAZ) of high-strength low-alloy (HSLA) steels was determined to occur between two closely spaced blocky MA particles. Blunt notch, crack tip opening displacement (CTOD), and precracked Charpy testing were used in this investigation to determine the failure criteria required for cleavage initiation to occur by this mechanism in the IC CG HAZ. It was found that the attainment of a critical level of strain was required in addition to a critical level of stress. This does not occur in the case of high strain rate testing, for example, during precracked Charpy testing. A different cleavage initiation mechanism is then found to operate. The precise fracture criteria and microstructural requirements (described in part I of this article) result in competition between potential cleavage initiation mechanisms in the IC CG HAZ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aging responses of 2124 Al-SiC p metal matrix composite (MMC) and unreinforced matrix alloy are studied and related to variations in tensile properties. The MMC is aged from Wo starting conditions: (i) stretched and naturally aged and (ii) re-solution treated. Accelerated aging occurs in both MMC conditions compared with unreinforced alloy. Tensile strengths and elastic moduli are improved in the MMC compared with the alloy, but ductility is reduced. Stretched MMC exhibits higher strength but lower ductility and modulus than re-solutioned MMC. The re-solutioned MMC fails by microvoid coalescence in low aging conditions, and by void nucleation and shear in high aging conditions. Failure of the stretched MMC initiates at the surface at specimen shoulders, illustrating the increased notch sensitivity of this condition, and propagates via a zigzag shear fracture mode. Zigzag facet size increases on gross aging. Particle fracture occurs during tensile failure, but also before testing as a result of the manufacturing process. © 1995 The Institute of Materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study was made of notch effects on the cleavage fracture of polycrystalline zinc. It was seen that the nominal fracture stress of SENB specimens was independent of notch angle. The maximum tensile stress below the notch at fracture in SENB specimens was shown to be different from the tensile stress at fracture in tensile testpieces over a temperature range from −196 to −17°C. The notch root strain at fracture was found to be the same as the uniaxial tensile fracture strain over this temperature interval. These results were interpreted as showing the cleavage fracture of polycrystalline zinc to be shear-stress or initiation controlled, as predicted by Stroh's dislocation model of cleavage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endothelial tip cells guide angiogenic sprouts by exploring the local environment for guidance cues such as vascular endothelial growth factor (VegfA). Here we present Flt1 (Vegf receptor 1) loss- and gain-of-function data in zebrafish showing that Flt1 regulates tip cell formation and arterial branching morphogenesis. Zebrafish embryos expressed soluble Flt1 (sFlt1) and membrane-bound Flt1 (mFlt1). In Tg(flt1(BAC):yfp) × Tg(kdrl:ras-cherry)(s916) embryos, flt1:yfp was expressed in tip, stalk and base cells of segmental artery sprouts and overlapped with kdrl:cherry expression in these domains. flt1 morphants showed increased tip cell numbers, enhanced angiogenic behavior and hyperbranching of segmental artery sprouts. The additional arterial branches developed into functional vessels carrying blood flow. In support of a functional role for the extracellular VEGF-binding domain of Flt1, overexpression of sflt1 or mflt1 rescued aberrant branching in flt1 morphants, and overexpression of sflt1 or mflt1 in controls resulted in short arterial sprouts with reduced numbers of filopodia. flt1 morphants showed reduced expression of Notch receptors and of the Notch downstream target efnb2a, and ectopic expression of flt4 in arteries, consistent with loss of Notch signaling. Conditional overexpression of the notch1a intracellular cleaved domain in flt1 morphants restored segmental artery patterning. The developing nervous system of the trunk contributed to the distribution of Flt1, and the loss of flt1 affected neurons. Thus, Flt1 acts in a Notch-dependent manner as a negative regulator of tip cell differentiation and branching. Flt1 distribution may be fine-tuned, involving interactions with the developing nervous system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon monoxide (CO) has emerged as a vascular homeostatic molecule that prevents balloon angioplasty-induced stenosis via antiproliferative effects on vascular smooth muscle cells. The effects of CO on reendothelialization have not been evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many studies have accounted for whole body vibration effects in the fields of exercise physiology, sport and rehabilitation medicine. Generally, surface EMG is utilized to assess muscular activity during the treatment; however, large motion artifacts appear superimposed to the raw signal, making sEMG recording not suitable before any artifact filtering. Sharp notch filters, centered at vibration frequency and at its superior harmonics, have been used in previous studies, to remove the artifacts. [6, 10] However, to get rid of those artifacts some true EMG signal is lost. The purpose of this study was to reproduce the effect of motor-unit synchronization on a simulated surface EMG during vibratory stimulation. In addition, authors mean to evaluate the EMG power percentage in those bands in which are also typically located motion artifact components. Model characteristics were defined to take into account two main aspect: the muscle MUs discharge behavior and the triggering effects that appear during local vibratory stimulation. [7] Inter-pulse-interval, was characterized by a polimodal distribution related to the MU discharge frequency (IPI 55-80ms, σ=12ms) and to the correlation with the vibration period within the range of ±2 ms due to vibration stimulus. [1, 7] The signals were simulated using different stimulation frequencies from 30 to 70 Hz. The percentage of the total simulated EMG power within narrow bands centered at the stimulation frequency and its superior harmonics (± 1 Hz) resulted on average about 8% (± 2.85) of the total EMG power. However, the artifact in those bands may contain more than 40% of the total power of the total signal. [6] Our preliminary results suggest that the analysis of the muscular activity of muscle based on raw sEMG recordings and RMS evaluation, if not processed during vibratory stimulation may lead to a serious overestimation of muscular response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concatenated single-mode-multimode-single-mode (SMS) structures are demonstrated as functional sensing platforms. The devices are fabricated by periodically inserting micrometric sections of multimode optical fiber (MMF) in a single-mode fiber (SMF). The periodic change of the core diameter produces a single strong resonant transmission notch, tunable in the wavelength range from 1200 to 1600 nm. It was found that the position of the notch changed with temperature and refractive index. The devices introduced here are highly compact (length less than 5 mm), simple to fabricate and robust; hence, they are adequate for diverse sensing applications. © 2013 The Japan Society of Applied Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to highlight the relationship between muscle motion, generated by whole body vibration, and the correspondent electromyographic (EMG) activity and to suggest a new method to customize the stimulation frequency. Simultaneous recordings of EMG and tri-axial accelerations of quadriceps rectus femoris from fifteen subjects undergoing vibration treatments were collected. Vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz). Muscle motion was estimated by processing the accelerometer data. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. EMG-RMS values were computed and analyzed before and after artifact suppression to assess muscular activity. Muscles acceleration amplitude increased with frequency. Muscle displacements revealed a mechanical resonant-like behaviour of the muscle. Resonance frequencies and dumping factors depended on subject. Moreover, RMS of artifact-free EMG was found well correlated (R 2 = 0.82) to the actual muscle displacement, while the maximum of the EMG response was found related to the mechanical resonance frequency of muscle. Results showed that maximum muscular activity was found in correspondence to the mechanical resonance of the muscle itself. Assuming the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization (i.e. to choose the best stimulation frequency) could be obtained by simply monitoring local acceleration (resonance), leading to a more effective muscle stimulation. Motion artifact produced an overestimation of muscle activity, therefore its removal was essential. © 2009 IPEM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to highlight the relation between muscle motion and electromyographyc activity during whole body vibration. This treatment is accounted for eliciting a reflex muscle activity in response to vibratory stimulation. Simultaneous recordings from quadriceps Rectus Femoris EMG and 3D muscle accelerations on fifteen subjects undergoing vibration treatments were collected. In our study vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz), with a constant amplitude. Muscle motion was estimated by processing accelerometer data. Displacements revealed a mechanical resonant-like behaviour of the muscle; resonance frequencies and dumping factors depended on subject. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. RMS values of artifact-free EMG were found correlated to the actual muscle displacement. The results were in accordance to the hypothesis of a proprioceptive response during vibration treatment. Nevertheless, motion artifacts produced an overestimation of muscle activity, therefore its removal was essential. © 2009 Springer Berlin Heidelberg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we present the design and fabrication of multi-notch optical fibre Bragg gratings for suppressing OH emission lines in the near infrared spectra of the night sky for astrophysical applications. We demonstrate a novel approach of fabricating 2, 3 and 5-notch filters using the phase mask technology, which show a good match with the model.