984 resultados para integrated device
Resumo:
根据耦合模理论和弯曲波导耦合器的结构特点,对平面弯曲波导耦合器的特性进行了分析,结果表明弯曲波导耦合器的弯曲半径和最小间距两个可调变量,增加了波导器件设计的灵活性;同时由于等效耦合长度的调制作用使得弯曲波导耦合器在波分复用/解复用中比平行直波导耦合器具有更大的复用带宽;分析了弯曲半径和最小间距对弯曲波导耦合器复用带宽的影响,为实际波导器件的设计制作提供了一定的理论依据.
Resumo:
The sun has the potential to power the Earth's total energy needs, but electricity from solar power still constitutes an extremely small fraction of our power generation because of its high cost relative to traditional energy sources. Therefore, the cost of solar must be reduced to realize a more sustainable future. This can be achieved by significantly increasing the efficiency of modules that convert solar radiation to electricity. In this thesis, we consider several strategies to improve the device and photonic design of solar modules to achieve record, ultrahigh (> 50%) solar module efficiencies. First, we investigate the potential of a new passivation treatment, trioctylphosphine sulfide, to increase the performance of small GaAs solar cells for cheaper and more durable modules. We show that small cells (mm2), which currently have a significant efficiency decrease (~ 5%) compared to larger cells (cm2) because small cells have a higher fraction of recombination-active surface from the sidewalls, can achieve significantly higher efficiencies with effective passivation of the sidewalls. We experimentally validate the passivation qualities of treatment by trioctylphosphine sulfide (TOP:S) through four independent studies and show that this facile treatment can enable efficient small devices. Then, we discuss our efforts toward the design and prototyping of a spectrum-splitting module that employs optical elements to divide the incident spectrum into different color bands, which allows for higher efficiencies than traditional methods. We present a design, the polyhedral specular reflector, that has the potential for > 50% module efficiencies even with realistic losses from combined optics, cell, and electrical models. Prototyping efforts of one of these designs using glass concentrators yields an optical module whose combined spectrum-splitting and concentration should correspond to a record module efficiency of 42%. Finally, we consider how the manipulation of radiatively emitted photons from subcells in multijunction architectures can be used to achieve even higher efficiencies than previously thought, inspiring both optimization of incident and radiatively emitted photons for future high efficiency designs. In this thesis work, we explore novel device and photonic designs that represent a significant departure from current solar cell manufacturing techniques and ultimately show the potential for much higher solar cell efficiencies.
Resumo:
A planar waveguide ring resonator was fabricated by organic-inorganic hybrid sol-gel materials; its sensitivity to ethanol vapor was experimentally investigated. It was found that dips in the transmission spectrum of the device shifted to longer wavelengths with increasing the ethanol concentration, and its sensitivity showed a linear relation with the ethanol concentration, showing a coefficient of 1.13 pm/ppm. In addition, the transmission loss of the ring resonator decreased with increasing the ethanol concentration. The measured characteristics suggest that the device may be considered as one of the candidates of alcohol vapor sensors. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A wavelength division multiplexer (WDM) for 980/1550 nm based on planar curved waveguide coupler (CWC) is proposed. Compared with conventional parallel straight waveguide coupler (SWC), this structure has more flexibility with two variable parameters of bending radius R and minimum edge-to-edge spacing do, which are the two main parameters for the splitting ratio of coupler and decrease the complexity of device design and fabrication. Based on coupled mode theory (CMT) and waveguide theory, R and do of the WDM CWC are designed to be R = 13.28 m and d(0) = 4.39 mu m. The contrast ratio (CR) and insertion loss (IL) for 980 and 1550 nm are CR1 = 24.62 dB, CR2 = 24.56 dB and IL1 = 0.014 dB, IL2 = 0.015 dB, respectively. The 3D beam propagation method (BPM) is used to verify the validity of the design result. The influence of R and d(0) variations on the device performance is analyzed. For CR > 20 dB, the variation ranges of R and d(0) should be within -0.10 to +0.44 m and -0.05 to + 0.02 mu m, respectively. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
Part I
The physical phenomena which will ultimately limit the packing density of planar bipolar and MOS integrated circuits are examined. The maximum packing density is obtained by minimizing the supply voltage and the size of the devices. The minimum size of a bipolar transistor is determined by junction breakdown, punch-through and doping fluctuations. The minimum size of a MOS transistor is determined by gate oxide breakdown and drain-source punch-through. The packing density of fully active bipolar or static non-complementary MOS circuits becomes limited by power dissipation. The packing density of circuits which are not fully active such as read-only memories, becomes limited by the area occupied by the devices, and the frequency is limited by the circuit time constants and by metal migration. The packing density of fully active dynamic or complementary MOS circuits is limited by the area occupied by the devices, and the frequency is limited by power dissipation and metal migration. It is concluded that read-only memories will reach approximately the same performance and packing density with MOS and bipolar technologies, while fully active circuits will reach the highest levels of integration with dynamic MOS or complementary MOS technologies.
Part II
Because the Schottky diode is a one-carrier device, it has both advantages and disadvantages with respect to the junction diode which is a two-carrier device. The advantage is that there are practically no excess minority carriers which must be swept out before the diode blocks current in the reverse direction, i.e. a much faster recovery time. The disadvantage of the Schottky diode is that for a high voltage device it is not possible to use conductivity modulation as in the p i n diode; since charge carriers are of one sign, no charge cancellation can occur and current becomes space charge limited. The Schottky diode design is developed in Section 2 and the characteristics of an optimally designed silicon Schottky diode are summarized in Fig. 9. Design criteria and quantitative comparison of junction and Schottky diodes is given in Table 1 and Fig. 10. Although somewhat approximate, the treatment allows a systematic quantitative comparison of the devices for any given application.
Part III
We interpret measurements of permittivity of perovskite strontium titanate as a function of orientation, temperature, electric field and frequency performed by Dr. Richard Neville. The free energy of the crystal is calculated as a function of polarization. The Curie-Weiss law and the LST relation are verified. A generalized LST relation is used to calculate the permittivity of strontium titanate from zero to optic frequencies. Two active optic modes are important. The lower frequency mode is attributed mainly to motion of the strontium ions with respect to the rest of the lattice, while the higher frequency active mode is attributed to motion of the titanium ions with respect to the oxygen lattice. An anomalous resonance which multi-domain strontium titanate crystals exhibit below 65°K is described and a plausible mechanism which explains the phenomenon is presented.
Resumo:
Background: The integrated treatment of first episode psychosis has been shown to improve functionality and negative symptoms in previous studies. In this paper, we describe a study of integrated treatment (individual psychoeducation complementary to pharmacotherapy) versus treatment as usual, comparing results at baseline with those at 6-month re-assessment (at the end of the study) for these patients, and online training of professionals to provide this complementary treatment, with the following objectives: 1) to compare the efficacy of individual psychoeducation as add-on treatment versus treatment as usual in improving psychotic and mood symptoms; 2) to compare adherence to medication, functioning, insight, social response, quality of life, and brain-derived neurotrophic factor, between both groups; and 3) to analyse the efficacy of online training of psychotherapists. Methods/design: This is a single-blind randomised clinical trial including patients with first episode psychosis from hospitals across Spain, randomly assigned to either a control group with pharmacotherapy and regular sessions with their psychiatrist (treatment as usual) or an intervention group with integrated care including treatment as usual plus a psychoeducational intervention (14 sessions). Training for professionals involved at each participating centre was provided by the coordinating centre (University Hospital of Alava) through video conferences. Patients are evaluated with an extensive battery of tests assessing clinical and sociodemographic characteristics (Positive and Negative Syndrome Scale, State-Trait Anxiety Inventory, Liebowitz Social Anxiety Scale, Hamilton Rating Scale for Depression, Scale to Assess Unawareness of Mental Disorders, Strauss and Carpenter Prognostic Scale, Global Assessment of Functioning Scale, Morisky Green Adherence Scale, Functioning Assessment Short Test, World Health Organization Quality of Life instrument WHOQOL-BREF (an abbreviated version of the WHOQOL-100), and EuroQoL questionnaire), and brain-derived neurotrophic factor levels are measured in peripheral blood at baseline and at 6 months. The statistical analysis, including bivariate analysis, linear and logistic regression models, will be performed using SPSS. Discussion: This is an innovative study that includes the assessment of an integrated intervention for patients with first episode psychosis provided by professionals who are trained online, potentially making it possible to offer the intervention to more patients.
Resumo:
[Es]En este proyecto se analizan el diseño y la evaluación de dos métodos para la supresión de la interferencia generada por las compresiones torácicas proporcionadas por el dispositivo mecánico LUCAS, en el electrocardiograma (ECG) durante el masaje de resucitación cardiopulmonar. El objetivo es encontrar un método que elimine el artefacto generado en el ECG de una manera efectiva, que permita el diagnóstico fiable del ritmo cardiaco. Encontrar un método eficaz sería de gran ayuda para no tener que interrumpir el masaje de resucitación para el análisis correcto del ritmo cardiaco, lo que supondría un aumento en las probabilidades de resucitación. Para llevar a cabo el proyecto se ha generado una base de datos propia partiendo de registros de paradas cardiorrespiratorias extra-hospitalarias. Esta nueva base de datos contiene 410 cortes correspondientes a 86 pacientes, siendo todos los episodios de 30 segundos de duración y durante los cuales el paciente, recibe masaje cardiaco. Por otro lado, se ha desarrollado una interfaz gráfica para caracterizar los métodos de supresión del artefacto. Esta, muestra las señales del ECG, de impedancia torácica y del ECG tras eliminar el artefacto en tiempo. Mediante esta herramienta se han procesado los registros aplicando un filtro adaptativo y un filtro de coeficientes constantes. La evaluación de los métodos se ha realizado en base a la sensibilidad y especificidad del algoritmo de clasificación de ritmos con las señales ECG filtradas. La mayor aportación del proyecto, por tanto, es el desarrollo de una potente herramienta eficaz para evaluar métodos de supresión del artefacto causado en el ECG por las compresiones torácicas al realizar el masaje de resucitación cardiopulmonar, y su posterior diagnóstico. Un instrumento que puede ser implementado para analizar episodios de resucitación de cualquier tipo de procedencia y capaz de integrar nuevos métodos de supresión del artefacto.