952 resultados para implante de prótese vascular
Resumo:
The determination of occlusal vertical dimension (OVD) is one of the most important steps in the rehabilitation treatment. Although various techniques have been used to measure it, none has proven to be scientifically accurate. Thus, the purpose of this study was to survey the different methods of measuring the vertical dimension and describe the clinical sequence of a method that we deem reliable.
Resumo:
The anatomical and functional impressions philosophies are presented to the professionals who are active in the area, so that they can review concepts and thus obtain more precise molds, based on scientific knowledge. In parallel, impression techniques recommended by the Prosthodontics subject from Araçatuba Dental School – UNESP are also commented.
Resumo:
Alveolar bone resorption is continuous throughout the life of edentulous patients, the prosthesis mismatch can generate during speech and chewing. An alternative to this would be to destabilize the denture reline, a maneuver which aims to readjust the denture base to the rim by the addition of a plastic film to the inner surface of the prosthesis material. This procedure may be direct, when performed in the clinic, or indirect when made in prosthetic laboratory. The aim this study is to demonstrate the technical of two reline for denture.
Resumo:
Zirconia abutments are used to obtain satisfactory aesthetic results in implant fixed anterior prostheses when metal abutments promote a grayish mucosal discoloration of the peri-implant soft tissues. However, there is a lack of studies to confirm the clinical performance of the peri-implant soft tissues surrouding zirconia abutments. This study described a case report of a patient treated with implant fixed all-ceramic crown made out on zirconia abutment after 3 years of followup. A 47-year-old female patient was admitted to the dental clinic (Aracatuba Dental School) complaining about the fracture of her implant fixed single crown in the region of the left lateral incisor. The patient chose the replacement of the fractured prosthesis for an allceramic crown. After 3 years of follow-up it was observed that maintenance of the aesthetic results and the peri-implant soft tissue without any inflammation or gingival recessions. Within the limitations of a case report, it can be conclude that zirconia abutments is a effective rehabilitation treatment because it preserves the aesthetics and function through the maintenance of peri-implant tissues.
Resumo:
The immediate complete denture is a prostheses made prior to teeth extraction, that aims to re-establish the patient aesthetics and function immediately after the removal of the remaining teeth. The objective of this paper is to report the technical procedures during the manufacture of immediate prosthesis. The study reports the clinical steps prior to teeth extraction as well as the surgical and maintenance procedures. The immediate complete denture is a viable rehabilitation method, especially to restore patients’ self-esteem, aesthetics and function promptly. An accurate planning and manufactory beholds better results
Resumo:
The maxillofacial prosthetic rehabilitation aims of individuals with craniofacial deformities resulting from trauma, congenital malformations or tumors. Many researches have been done to improve the stability and retention of dentures in patients. With the advent of osseointegration, the maxillofacial prosthesis suffered a major advance making possible the realization of prosthetic works with stability, aesthetic quality and predictable results. This paper reviews the literature regarding the use of zygomatic implants in the fixation of maxillofacial prostheses.
Resumo:
The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.
Resumo:
The population’s life expectancy is growing every year. This fact highlights the importance of the elderly for the dentistry. The oral cavity quality has great influence on quality of life at both the biological and the psychological and social factors by maintaining a self-esteem, self-expression, communication and satisfactory facial aesthetics. Unfortunately, the number of edentulous elderly population is also high, which may create problems to their social life. Therefore, the objective of this study was to demonstrate and evaluate the difficulties of treating edentulous patients, comparing data prior to treatment to post data after treatment by complete dentures made to the patients undergoing oral rehabilitation in the Dental Clinic of the Faculty of Dentistry of Adamantina – FAI. For this study, questionnaires were filled in the form of answers developed alternative focused on the degree of patient satisfaction, the current situation of occlusion, and outcome of treatment. The results showed that 96% of patients were satisfied with the results obtained in the treatment, all of whom believed that the prosthesis helped them feel better aesthetically and improved self-esteem. By this methodology, it was concluded that the degree of satisfaction was high, but the services provided must be constantly reevaluated, once the elderly population presents a wide labor market for dental professionals and demand level services will certainly increase each year.
Resumo:
The maintenance of Implant-supported Prosthesis is essential to the success of dental implants. Therefore, the aim of the study was to conduct a review the literature addressing maintenance Implant-Supported Prosthesis in order to guide planning for the longevity of oral rehabilitation. We conducted a detailed search strategy for the Pubmed / Medline Dentistry and Oral Science, used as descriptors: “Oral Hygiene“ and “Dental Implant until July, 2013. The results were grouped together in topics (Clinical Exam and Oral Hygiene) and discussed. Conclusion: A regular maintenance program for oral patient implantprosthesis is essential to the longevity of the treatment. Different methods and devices are effective for cleansing. However one orientation (in writing) must be offered to patients, since inadequate cleaning can create regions of abrasion on the surfaces of abutments and dental implants.
Resumo:
The purpose of this study was to analyze the biomechanical interactions in bone tissue between short implants and implant-supported crowns with different heights. Two models were made using the programs InVesalius 3.0, Rhinoceros 4.0 and Solidworks 2010. The models were established from a bone block with the short implant (3.75 x 8.5 mm) with geometry Morse taper connection (MT). The height of the crown (cemented) was set at 10.0 mm and 15.00 mm. The models were processed by programs and 10 NEiNastran Femap 10.0. The force applied was 200N (vertical) and 100N (oblique). The results were plotted on maps Voltage Maximum Principal. Statistical analysis was performed using ANOVA. The results showed that the increase in crown height, increased stress concentration in the crown of 15 mm under oblique loading (p <0.001), the oblique loading has significantly expanded the area of stress concentration (p <0.001). Conclusion:the increase of the crown increased the stress concentration, being statistically significant for short implants Morse taper. The mesial and distal region had the highest concentration of stresses under oblique loading. The oblique loading was more harmful when compared with axial loading, being statistically significant.
Resumo:
The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.
Resumo:
O tratamento de indivíduos totalmente desdentados, desde os primórdios dos conceitos e fundamentos da reabilita-ção oral, tem sido um grande desafio para os profissionais da odontologia, especialmente em relação à retenção, suporte e estabilidade das próteses totais. Esses pré-requisitos protéticos estão geralmente deficientes em pacientes que apresentam um longo período de desdentamento, com grande atrofia e reabsor-ção dos rebordos alveolares, especialmente no arco mandibular. Com o advento da implantodontia e com a evolução sequencial dos estudos envolvendo o processo de osseointegração essa filosofia se tornou otimizada pelas próteses totais fixas implantossuportadas, denominadas próteses protocolo, repre-sentando uma modalidade clinicamente previsível no âmbito da dontologia moderna. Com base nessa premissa, o objetivo do presente trabalho é elucidar a sequência clínica de uma reabilitação total bimaxilar, conjugando-se uma prótese total convencional superior e uma prótese protocolo inferior.
Resumo:
The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
Maxillofacial deformities may cause awkward and embarrassing bearer. These patients present serious psychological, family and social issues becoming traumatized and complexed. These deformities can have congenital origin, malformations and developmental disorders, or can be caused by pathological mutilation such as necrotizing diseases and surgical oncology, or traumas such as traffic and work accidents.